CS Paper Radar

Analysis of Measurements in a Microwave Oven with High Level of Non-Ionizing Radiation (NIR) Before and After Repair

Júlia da L. A. Silva, Vicente A. de Sousa, Marcio E. C. Rodrigues, Fred S. R. Pinheiro, Gutembergue S. da Silva, Halysson B. Mendonça, Fernanda E. S. Galdino, Ricardo Q. de F. H. Silva

cs.NI ·submitted 2026-09-15 23:51 UTC · v1
publishedunusual

Abstract

Non-ionizing radiation is the subject of several applications, such as the microwave oven, which is very popular. Its use is characterized by direct user operation and reduced distances between users and the NIR source. Therefore, the level of human exposure in this scenario deserves attention as it is a potential cause of biological effects. In this sense, this paper presents the measurement of a microwave oven with a high level of NIR (above the limit defined by the standard) before and after two types of suggested repairs: the use of epoxy putty (Repair 1) and the replacement of the external surface of the oven (Repair 2). The definitions of measurement methodology, based on FDA and INMETRO standards, are presented and discussed. Finally, we describe an analysis of the efficiency of these repair methods aiming at the safety operation.

Journal ref
Journal of Communication and Information Systems 2024, 39(1), 160-163
DOI
10.14209/jcis.2024.16

Closest papers

Nearest neighbours by meaning across the whole index.

Non-Ionizing Radiation Analysis in Close Proximity to Antenna Tower: A Case Study in Northeast Brazil

cs.NI ·2026-09-28 ·André B. F. Diniz, Vicente A. Souza, Marcio E. C. Rodrigues, Halysson B. Mendonça, Gutembregue S. Silva +1 more
publishedhighly cited similarity 0.42
Abstract

While the amount of telecommunications services grows rapidly in the whole world, humans get potentially more exposed to Non-Ionizing Radiation (NIR) from a number of different sources. This paper has a number of goals, including monitoring radiation levels in an everyday situation, an investigation of how national and international regulations organs address NIR levels and a demonstration of scientific production trends regarding this topic. The work also presents a bibliometric study about the main scientific productions and trends related to NIR measurements, with focus on the field of Telecommunications. Another contribution is a case study in Natal, Brazil, where NIR levels were monitored in four distinct locations over a period of 24 hours each and compared to the current regulations. The result is a quantitative analysis of the amount of radiation that some populations might be exposed to in distinct moments of the day. Measurements were carried out in the proximity of an antenna spot, since it could represent a source of high NIR levels (a worst case of human exposure). This campaign differs from older studies by including a more intense usage of microwaves frequencies due to operating 4G and pre-5G systems in Brazil. Finally, a statistical study involving the measurements is conducted, concluding the analysis of how some population groups might be affected by NIR.

0.52

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.36
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Human Exposure to Non-Ionizing Radiation from Indoor Distributed Antenna System: Shopping Mall Measurement Analysis

cs.NI ·2026-09-16 ·Júlia da L. A. Silva, Vicente A. de Sousa,, Marcio E. C. Rodrigues, Fred Sizenando Rossiter Pinheiro, Gutembergue Soares da Silva +6 more
publishedhighly cited similarity 0.35
Abstract

It is crucial to monitor the levels of Non-Ionizing Radiation (NIR) to which the general population may be exposed and compare them to the limits defined in the current standards, in view of the rapid rise of communication services and the prospects of a connected society. A high number of people visits shopping malls and since these locations usually have several indoor antennas close to the public, it is therefore a kind of place that must be evaluated. Thus, this work presents measurements of the electric field in a shopping mall located in Natal, Brazil. We proposed a set of six measurement points, following two criteria: places with great the flow of people and the presence of one or more Distributed Antenna System (DAS), co-sited or not with WiFi access points. Results are presented and discussed in terms of the distance to DAS (conditions: near and far) and flow density of people in the mall (scenarios: low and high number of people). The highest peaks of electric field measured were 1.96 and 3.26 V/m, respectively corresponding to 5% and 8% of the limits defined by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Brazilian National Telecommunication Agency (ANATEL).

0.58

Vertical Assessment of RF-EMF Exposure in a Building Adjacent to a Multi-Operator Shared Base Station

cs.NI ·2026-09-11 ·Ricardo Q. de F. H. Silva, Marcio E. C. Rodrigues, Fred S. R. Pinheiro, Gutembergue S. da Silva, Halysson B. Mendonça +1 more
published similarity 0.34
Abstract

This paper extends a previously published proposed approach for estimating worst-case exposure scenarios in buildings using publicly available Base Station (BS) parameters, applying it to a critical case involving a multi-operator shared site. Radiofrequency Electromagnetic Fields (RF-EMF) exposure was assessed on every floor of a 20-story building facing the site, revealing significantly higher levels near the center of the antennas' estimated vertical zone of interest, with a peak of 31.86 V/m, 23.95 times higher than the street-level peak value. However, due to uncertainties in the input parameters, measurements across all locations within the zone of interest are required to accurately identify the floor of maximum exposure. The results demonstrate the usefulness of the proposed estimation approach and highlight the need for improved methods that consider BS antenna configurations and current technical information to ensure accurate assessments of exposure to RF-EMF.

0.39

Non-Ionizing Radiation Measurements for Trajectography Radars

cs.NI physics.ins-det ·2026-09-28 ·J. Marcos Leal Barbosa Filho, Millena M. de M. Campos, Daniel L. Flor, William S. Alves, Adaildo G. D'Assunção +2 more
published similarity 0.34
Abstract

This work presents a Non-Ionizing Radiation (NIR) measurement campaign and proposes a specific measurement method for trajectography radars. This kind of radar has a high gain narrow beam antenna and emits a high power signal. Power density measurements from a C-band trajectography radar are carried out using bench equipment and a directional receiving antenna, instead of the commonly used isotropic probe. The measured power density levels are assessed for compliance test via comparison with the occupational and general public exposure limit levels of both the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Brazilian National Telecommunication Agency (Anatel). The limit for the occupational public is respected everywhere, evidencing the safe operation of the studied radar. However, the limit for the general public is exceeded at a point next to the radar's antenna, showing that preventive measures are needed.

0.44

RF-VoID: Towards Bandwidth-Efficient Exterior Tile Void Detection via Narrowband Radio-Frequency Representation Learning

eess.SP cs.AI ·2026-09-11 ·Xinyan Chen, Ruiqin Ma, Shunsuke Shoda, Changyu Zhou, Ryo Natsuaki +3 more
unusual similarity 0.33
Abstract

Hidden debonding behind exterior ceramic tiles is a falling-tile hazard, and millimeter-wave radar offers a non-contact way to find it. Conventional interpretation first reconstructs a range profile, so its reliability is bounded by the available bandwidth, yet bandwidth is what sets the cost, the acquisition time, and the regulatory footprint of a deployed system. This work asks whether that bandwidth can be traded for computation. A 4-40 GHz stepped-frequency system scans twelve exterior-wall specimens containing 0.5-1.0 mm air voids at different depths and interfaces, and the bandwidth dependence of A-scan, B-scan, and C-scan interpretation is analyzed to establish the resolution bound. RF-VoID is then proposed, which decides directly on the narrowband complex response: the sub-band is kept in its measured frequency order with amplitude and phase alongside the in-phase and quadrature channels, a dual-branch encoder reads it along the physical frequency axis using relative position encoding and a distance-dependent locality bias, and an inspection-oriented objective handles the class imbalance and the asymmetric error cost of facade screening. Under a mixed-sample protocol the method attains 98.61% accuracy and a 95.84% F1-score with 0.5 GHz of bandwidth, a seventy-two-fold reduction relative to the full sweep, without range-profile reconstruction, deconvolution, or depth-slice selection; on specimens held out entirely from training it remains the strongest of the compared models, with a mean macro F1-score of 62.12% at 0.5 GHz that rises to 68.57% at 1 GHz.

0.26

When Magnitude Suffices: Reconstructing Time-Domain-Gated Microwave Signals Without Phase on a Thoracic Phantom

cs.LG physics.app-ph ·2026-10-16 ·Maciej Cichoń, Patrycja Gołaś, Maksymilian Bartosik, Angelika Walczak, Agata Bielecka-Dąbrowa +1 more
unusual similarity 0.32
Abstract · 18 pages, 7 figures, 4 tables

Time-domain gating separates the arrivals that form a microwave S-parameter measurement. It requires the measurement of complex values, so this application almost always uses a vector network analyzer (VNA). We show that, on one calibrated measurement configuration, the gated magnitude the VNA would give can be reconstructed from a magnitude-only sweep of a spectrum analyzer with a tracking generator (SA). We select the gate center for separability of the measured states, correct each instrument once by a per-bin subtraction of a reference state, and train a fully connected network on sweeps from both instruments. The test object is a torso phantom with lung-shaped compartments whose filling takes eleven dielectric states, each held out in turn. On $S_{11}$ the reconstruction from SA input reaches a shape error of 0.08 dB$^2$ with a state ordering of 0.81. This matches the reconstruction from VNA input. On $S_{21}$ it reaches 0.82 dB$^2$ and keeps the ordered groups of the states. An explicit phase prediction performs much worse, because gating needs the phase to about 0.2 rad RMS. Across eleven measurement configurations the dependence of phase on magnitude is strong for reflection and weak for transmission. This explains the difference between $S_{11}$ and $S_{21}$. Where the magnitude carries enough of the phase, a scalar instrument gives the gated response without any phase measurement after installation. On the open UM-BMID breast data set, with whole phantoms held out, the shape error of the network is 30 percent lower than that of a per-bin linear map.

0.26

Sensitivity and Identifiability of Tumor-Related Changes in Longitudinal Microwave Breast Imaging

eess.SP physics.med-ph ·2026-10-19 ·Somayeh B. Shafiei, Ian Jeffrey, Vahab Khoshdel, Joe LoVetri
similarity 0.32
Abstract

Microwave imaging could monitor breast tumor response to neoadjuvant chemotherapy, but between-visit changes in breast positioning and normal tissue may confound tumor-related changes. We use eight patient-specific dielectric models from longitudinal MRI of two patients at four time points. For each model, 24-port S-parameters were simulated from 1 to 3 GHz, and Jacobians computed for tumor permittivity and loss, fibroglandular tissue (FGT) permittivity, and breast rotation and translation. 1 mm positioning changes produced changes 20 to 50 times larger than a 10% tumor permittivity change above 2 GHz. Nevertheless, tumor sensitivity patterns were weakly aligned with positioning patterns, tumor-FGT similarity exceeded 0.8 at only some visits, and the Jacobians remained well conditioned. Tumor responses are thus small but separable; monitoring will require positioning correction, frequency selection, and noise-aware detectability analysis.

0.23