Numerical Simulation of Transdermal Insulin Delivery Using a Coated Microneedle in a 2D Skin Model

Milana Tesfamarian, Michael Heisig, Gabriel Wittum, Rolf Krause

cs.CG ·submitted 2026-09-16 17:07 UTC · v1
unusual

Abstract

In this work, we present a computational model to investigate transdermal insulin delivery using coated microneedles. A detailed skin geometry incorporating a coated microneedles was developed to analyze insulin release through the different skin layers and to evaluate the influence of key transport parameters. The model represents the major skin layers: the stratum corneum, viable epidermis, and dermis. Unstructured grids were used to achieve a reliable resolution of the model. The simulations provide insights into the permeation of insulin from the coated microneedles and the transport and distribution across the different skin layers. Finally, the simulation results were compared with experimental data to evaluate the predictive capability of the model.

Closest papers

Nearest neighbours by meaning across the whole index.

A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensing

eess.SP physics.bio-ph ·2026-11-13 ·Kavya Saravanan, Rohini Ramachandran, Jean Pierre Ndabakuranye, Isabelle Shearer, Gursimran Singh +6 more
unusual similarity 0.40
Abstract

Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.

0.25

Optimized size, shape and orientation of rhombic transposition flaps and excisions by gradient-based methods

cs.CE physics.med-ph ·2026-11-03 ·Niels Aage, Brandon Marshal Parks
unusual similarity 0.39
Abstract · 21 pages, 9 figures, 4 tables. Submitted to the Journal of the Mechanical Behavior of Biomedical Materials

This work presents a new method for gradient-based optimization of the rhombic transposition flap and the excision it closes, which set the strain of the skin after closure. Previous studies swept at most three parameters. Here, using structural optimization methods, up to eight variables, two flap angles, two cut lengths and the size, shape and position of the rhombic excision, are optimized under up to 32 geometric and stress constraints. The skin is a pre-stretched, incompressible hyperelastic membrane that wrinkles instead of carrying compression. Smoothed level-sets on a fixed grid represent the cuts, and springs between interpolated points the sutures, so designs change without remeshing and the adjoint method gives the sensitivities. The energy the surgery adds to the skin is minimized, and the model reproduces the energies of a published 48-design sweep with a median deviation of 5%. The optimal flap angles, $(-23^\circ, 31^\circ)$, lie outside the swept range and add 63% less energy than the Limberg flap and 15% less than the best swept design. Under unequal in-vivo tension, the optimal flap turns with the direction of the tension. Fitting the excision to the lesion and its margin lowers the energy by a further 35%, and with all eight variables it is 78% below the Limberg flap. This optimum is the same for finer grids, narrower cuts and wider undermining, although wider undermining reduces its gain. Lowering its suture-line stress by 41% costs only 2.3% more energy.

0.32

Geometry-Dependent Properties of Physically Crosslinked PPy-PVA Hydrogels Enable Tunable Iontophoretic Drug Delivery

cs.RO physics.med-ph ·2026-10-22 ·Heather Jin Hee Kim, Mohsen Alishahi, Kyuin Park, Mikaila K. Roncevich, Larissa M. Shepherd +1 more
top venueunusual similarity 0.39
Abstract

Objective: Iontophoretic drug delivery has primarily relied on current modulation to regulate drug transport. Here, we investigate hydrogel geometry, microstructure, and local electric fields as alternative mechanisms for controlling transdermal delivery. Methods: Bovine serum albumin (BSA) was encapsulated in polypyrrole-polyvinyl alcohol (PPy-PVA) hydrogels. Five geometries, including Hilbert curve-based designs, were fabricated to vary pore architecture and local electric field distributions. We optimized PPy content, drug loading, and current density. Electric fields were evaluated using finite element analysis, and microstructures were characterized by scanning electron microscopy. Drug transport was assessed using Franz diffusion cells with artificial membranes. Results: Hydrogel geometries exhibited distinct microstructures and electric field distributions. Iontophoresis substantially enhanced permeability compared with passive diffusion, while individual geometries produced different cumulative release, flux, and permeability profiles. The average iontophoretic permeability was (3.80 +/- 1.93) x 10^-5, exceeding previously reported values using artificial membranes. Conclusion: Geometry-driven fabrication of drug-loaded hydrogels enables tunable transport characteristics under both iontophoretic and passive conditions. Significance: Geometry-mediated control offers an alternative approach to regulating iontophoretic drug delivery without requiring individual current-density modulation.

0.38

Physics-Guided Synthetic High-Frequency Ultrasound Generation for Skin Layer Segmentation

cs.LG cs.CV ·2026-09-11 ·Junkyung ju, Kyungho Yoon, Minwoo Shin
publishedcode/data similarity 0.37
Abstract · 12 pages, accepted at MICCAI DH4H Workshop 2026

High-frequency ultrasound (HFUS) enables noninvasive visualization of superficial skin structures, but automated skin-layer analysis is limited by the scarcity of densely annotated data. Existing real HFUS datasets commonly provide annotations for superficial targets such as the epidermis and subepidermal low-echogenic band (SLEB), while dense labels for deeper structures such as dermis, subcutaneous tissue, fascia, and muscle are rarely available. We propose a physics-guided synthetic HFUS generation framework for skin layer segmentation. The framework constructs multilayer acoustic skin phantoms, assigns layer dependent acoustic properties, and uses k-Wave simulation to generate paired synthetic HFUS images, dense layer masks, and simulation metadata. To evaluate whether the generated data provide transferable supervision, we use it for downstream segmentation pretraining and fine-tune the models on real Mendeley HFUS data. Synthetic pretraining followed by real fine-tuning achieved real-domain performance comparable to real-only training and improved mean Dice/IoU in three of four evaluated trainable architectures. These results suggest that physics-guided synthetic HFUS images contain transferable anatomical and textural cues for real-domain skin layer segmentation, although further reduction of the synthetic-real appearance gap is needed to enable greater gains. The code and data are available at: https://github.com/Finn-02/synthetic-hfus-skin-layer-segmentation.

0.50

A Local Stabilized Isogeometric Formulation with Discontinuous Pressure for Mesh-Conforming and Immersed Analysis of Nearly Incompressible Elasticity

cs.CE math.NA ·2026-10-26 ·Ashkan Ali Madadi, Thomas J. R. Hughes
similarity 0.36
Abstract

Nearly incompressible materials arise in soft tissues, elastomers, gels, and other soft solids. Yet, numerical modeling remains challenging because displacement-based formulations can exhibit volumetric locking near incompressibility. Mixed displacement-pressure formulations address this difficulty but require compatible approximation spaces satisfying the inf-sup condition. In mixed formulations, discontinuous pressure spaces are attractive since pressure degrees of freedom can be condensed locally. In high-order isogeometric analysis, however, their Galerkin stability requires pressure-grid coarsening that increases with polynomial degree. Here, we develop a variational multiscale (VMS) stabilized mixed isogeometric formulation that retains this locality while substantially relaxing the restriction. The key observation is that VMS stabilization controls nonconstant elementwise pressure modes and is unconditionally stable with respect to its parameter, provided the elementwise constant pressure component satisfies the inf-sup condition. Consequently, for maximally continuous displacement splines, a pressure grid coarsened by a factor of two satisfies the constant-mode inf-sup criterion independently of polynomial degree. Local condensation then yields a displacement-only system, facilitating use in existing displacement solvers. The formulation is further extended to immersed isogeometric analysis with extended B-splines, pressure-cell aggregation, subdivision-based cut-cell quadrature, and weak enforcement of essential boundary conditions. Discrete inf-sup studies and convergence analyses in the Kirsch and Cook's membrane benchmarks demonstrate stability and show that the immersed treatment preserves mixed stability properties. The proposed framework therefore provides a local, high-order, and robust approach for nearly incompressible problems in mesh-conforming and immersed settings.

0.26

AI-guided robotic in situ fabrication of curvature- and tissue-adaptive wireless bioelectronics

cs.RO ·2026-11-13 ·Hiroyuki Tetsuka, Jiaju Ma, Naomi Kumano, Minoru Hirano
similarity 0.36
Abstract

Personalized bioelectronic devices for wound therapy require not only conformal fabrication on complex body surfaces but also functional adaptation of their electrical characteristics to individual wound geometries. Here, we present an AI-guided robotic in situ printing platform for fabricating wireless wound electrotherapy devices directly on transparent wound dressings. The system integrates a 3D vision camera, a six-degree-of-freedom robotic arm, direct-ink-writing, and geometry-aware RF design optimization. AI-based wound segmentation is used to determine wound dimensions and local surface curvature, while the reconstructed three-dimensional geometry is incorporated into the electromagnetic design of the receiving coil and interdigitated electrodes. In contrast to conventional approaches that use surface geometry only for trajectory generation, the proposed method accounts for both anatomical curvature and tissue dielectric loading to compensate for geometry-induced shifts in resonant behavior. A printable silver ink was characterized in terms of rheology, dimensional reproducibility, electrical resistance, and electromechanical stability, and was used to fabricate multilayer wireless devices directly on curved polyurethane dressings. Wireless power transfer, impedance characteristics, and electric-field delivery were evaluated experimentally and numerically. Finally, robotic in situ fabrication was demonstrated on an anthropomorphic tissue-equivalent forearm phantom, where the measured dielectric properties of the phantom were incorporated into the RF optimization, enabling resonant operation near the target frequency of 25 MHz. This work establishes a perception-to-design-to-fabrication framework for geometry-adaptive wireless bioelectronics and provides a technological foundation for future physical-AI-enabled manufacturing of personalized on-body electrotherapy devices.

0.23

Mechanical behaviour of the intact brain-skull interface under tension, compression and shear

cs.CE ·2026-11-12 ·Sajjad Arzemanzadeh, Karol Miller, Ron Kikinis, Adam Wittek
similarity 0.35
Abstract

The brain-skull interface governs the boundary/contact conditions of the brain in computational head models, yet its mechanical behaviour remains poorly characterised experimentally. We characterised the brain-skull interface by testing brain-skull complex samples (skull bone, meninges and brain tissue in their native arrangement) excised from 19 sheep cadaver heads under uniaxial tension and compression at strain rates of 0.002, 0.02 and 0.2 s$^{-1}$ and simple shear at 0.02 s$^{-1}$. Histology confirmed that the meningeal layers remained intact and attached to the brain and skull after excision. We acquired magnetic resonance images of every sample, reconstructed their geometry and developed a sample-specific finite element model of each experiment. We represented the brain tissue using a second-order Ogden hyperelastic model and the brain-skull interface using a cohesive zone model. Using inverse finite element analysis, we first calibrated the brain tissue parameters for each subject. Keeping these parameters fixed, we then identified the interface parameters from the corresponding brain-skull complex specimen. The brain tissue shear modulus increased with strain rate from 0.94 $\pm$ 0.16 kPa at 0.002 s$^{-1}$ to 1.60 $\pm$ 0.30 kPa at 0.2 s$^{-1}$. In contrast, the interface properties (maximum normal traction 2.35 $\pm$ 0.81 kPa, maximum tangential traction 4.14 $\pm$ 0.97 kPa, and fracture energy 0.35 $\pm$ 0.14 N m$^{-1}$) showed no significant dependence on strain rate or loading mode. In all samples, failure occurred within the subarachnoid space. Neither a rigid brain-skull connection nor frictionless sliding contact with separation reproduced the measured mechanical response or failure mode of the brain-skull interface. Our experimentally derived cohesive zone model provides a realistic representation of the brain-skull interface for computational head models.

0.32

Data-Driven Design Optimization of Streaming-Potential-Mediated Electrokinetic Transport of Viscoelastic Fluids in Microchannels

cs.LG physics.flu-dyn ·2026-08-30 ·Ankan Basu, Sumanta Banerjee
unusual similarity 0.34
Abstract

Streaming-potential-mediated transport of viscoelastic fluids has attracted research attention owing to its applications in electrokinetic energy conversion and microfluidic transport. Existing analytical and semi-analytical models in published literature provide valuable physical insights, but require repeated numerical evaluations for exploring large design spaces and identifying the optimal operating conditions. In this work, a surrogate-assisted framework is developed for rapid design optimization of pressure-driven electrokinetic transport of simplified Phan-Thien-Tanner fluids in a slit microchannel. A high-fidelity numerical database is generated over a broad range of governing dimensionless parameters, which includes the zeta potential, the Debye parameter, the Dukhin number, and the viscoelastic parameter. A Machine Learning surrogate model is subsequently trained to accurately approximate the nonlinear relationship between the governing parameters and the streaming potential, while the volumetric flow rate and hydroelectric energy conversion efficiency were calculated from closed form equation by using the streaming potential predicted by the surrogate. This is coupled with a multi-objective optimization strategy to identify operating conditions that simultaneously maximize energy conversion efficiency and volumetric flow rate. The proposed methodology can significantly accelerate parametric exploration compared with repeated numerical simulations across different parameters and provides practical design guidelines for electrokinetic microfluidic devices. The study demonstrates the potential of combining computational fluid mechanics with data-driven surrogate modeling for efficient engineering design and optimization.

0.26