High-Voltage Optocoupler Amplifier for Electrostatic Actuators

George C. Jurgiel, Alex S. Miller, Jeffrey H. Lang

cs.RO eess.SYphysics.ins-det ·submitted 2026-09-24 14:52 UTC · v1
publishedunusual

Abstract

Many electrostatic actuators require multi-kilovolt drive voltages at sub-milliamp currents, a task poorly suited for conventional switching devices. As an alternative, we demonstrate a high-voltage amplifier using optocouplers as active elements. The amplifier produces a 20-kV peak-to-peak output with up to 500 Hz bandwidth while maintaining a minimal component count. By using optocouplers as linear devices in feedback, lower harmonic distortion and higher bandwidth are achieved than offered by equivalent PWM amplifiers. This design improves the viability of electrostatic actuators by providing a simpler method to achieve useful drive waveforms.

Comment
To be published in the proceedings of the 2026 IEEE Energy Conversion Congress & Expo (ECCE)

Closest papers

Nearest neighbours by meaning across the whole index.

Measurements and Analysis of Distortion in Inertial Force Exciters for Flat-Panel Loudspeakers

eess.SY ·2026-10-13 ·Stephen F. Roessner, Michael C. Heilemann
publishedunusual similarity 0.41
Abstract · Accepted to 161st Convention of the Audio Engineering Society, Nashville, TN, USA, Oct. 2026

Flat-panel loudspeakers are typically driven by dynamic exciters that employ a voice coil coupled to a reaction mass to exert force on the panel. Unlike conventional loudspeakers, where the cone is relatively light weight, heavy panels may require significant exertion from the driver to achieve sound pressure levels required of consumer grade loudspeakers. Overexertion can cause harmonic distortion and reduced sound quality, especially in drivers where the voice coil is not centered in the magnetic field. There are many different exciters available commercially with different power ratings and price points. The frequency response, linearity, total-harmonic distortion (THD), intermodulation distortion (IMD), and force vs. displacement were measured for three types of exciters to determine the consistency of manufacturing and use in panel loudspeakers. These exciters were found to have high variability in all metrics among units of the same type. Distortion metrics such as IMD may be reduced by running impedance sweeps to match exciters with similar response characteristics in multi-actuator panels.

0.32

A Long-Legged, Direct-Drive Monopedal Robot Achieves Exceptional Jump Height

cs.RO ·2026-09-24 ·Gihyeok Na, Justin K. Yim
similarity 0.39
Abstract · 8 pages, 12 figures, submitted to ICRA 2027

We demonstrate a jumping robot that reaches high (7.6 m) and fast (190 ms stance time) jumps from a single long leg driven by a direct-drive transmission, without elastic energy storage. At 281 g, it achieves the highest jump yet reported for an electrically actuated, spring-free system. The leg uses a new fabric-wrap transmission that provides a variable mechanical advantage, keeping a small electric motor near its peak power output through the stroke while bracing the long, lightweight leg against buckling. A balancing module at the top of the leg uses small propellers to control the leg's orientation on the ground and in the air, where the long leg provides a large moment arm for the control torques. The robot is validated outdoors with vertical jumps, attitude control on the ground and in flight, and tilted jumps.

0.24

An Open-Source da Vinci X/Xi Instrument Module for Laparoscopic Surgery Research

cs.RO ·2026-11-16 ·Douglas McDonough, Justin Liao, Jiawei Ge, Antony Goldenberg, Yvonne Zhang +4 more
code/data similarity 0.37
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution. ‡ Equal supervision

Studying electrosurgical tasks on a research robot requires control of both instrument motion and energy activation, along with a record of when each action occurs. This paper presents an open-source module for da Vinci X/Xi instruments on a UR5/UR5e robotic arm. Five motors transmit torque through timing belts to spring-loaded drive discs. An electrosurgical interposer accepts software commands, gives the surgeon's foot pedals priority, and records the source of each activation request. In bench testing, the interposer recorded all 12 activation and deactivation events from six pedal presses. Ex vivo demonstrations included monopolar and bipolar coagulation of splenic tissue and monopolar cutting during gallbladder dissection. Optical tracking of the Fenestrated Bipolar Forceps showed that calibration brought pitch and yaw gains from 0.904 and 1.14 to 1.00 and 1.02, respectively. The module enables researchers to record instrument motion, video, and the timing and source of electrosurgical commands during laparoscopic tasks.

0.32

A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation

eess.SP ·2026-09-19 ·Jiatong Jiang, Andrea Bottin, Simos Koutsoftidis, Enrico Merlo, Georgios Gryparis +4 more
unusual similarity 0.37
Abstract · 12 pages, 10 figures, to be submitted to journal

We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators.

0.28

Design and Validation of a Lightweight, Low-Profile Powered Knee Prosthesis with Quasi-Direct Drive Actuation

cs.RO ·2026-09-02 ·Ross J. Cortino, Ryan Posh, Emily G. Keller, Robert D. Gregg
similarity 0.36
Abstract · 11 pages, 8 figures, Under Review

Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.

0.32

Real-Time Reference Shaping for Servo Systems

eess.SY ·2026-08-31 ·Zehui Lu, Yebin Wang, Go Sato, Fujita Tomoya
similarity 0.35
Abstract

This paper addresses real-time motion planning for servo systems subject to nonlinear, state-dependent actuator constraints. A reference reshaping method is proposed that combines analytical optimality with high computational efficiency. Using Karush-Kuhn-Tucker conditions, the problem structure is explicitly characterized, and it is shown that the optimal solution lies within a finite set of candidate points. The complete solution set is constructed via closed-form expressions and a small-scale eigenvalue problem, yielding a deterministic algorithm that recovers the exact optimal solution without iterative optimization or root-finding. To address kinematic mismatch induced by aggressive commands, a real-time trajectory compensator is introduced to correct accumulated position error while preserving feasibility. Simulation results demonstrate significant computational speed improvements over existing methods, enabling real-time implementation at frequencies approaching 100 kHz.

0.24

Structure-Actuation Co-Design of All-Electric Heavy-Duty Robotic Manipulators

cs.RO eess.SY ·2026-10-27 ·Mohammad Bahari, Amir Hossein Barjini, Jouni Mattila
benchmark similarity 0.35
Abstract · 6 pages manuscript submitted to a conference (ICCMA 2026)

This paper presents a mixed discrete-continuous multiobjective bilevel framework for the structure-actuation co-design of all-electric heavy-duty robotic manipulators. The upper level optimizes manipulator geometry and actuation topology, while joint-specific lower-level searches construct feasible archives of discrete motor, gearbox, and screw configurations. A system-level coordinator selects actuator packages according to hardware mass, co-design cost, and loss-aware supply energy, and the resulting actuator masses are fed back to the robot model until a mass-consistent fixed point is obtained. Evaluation on a full-pose SE(3) benchmark with a 100-kg tool payload yields eight feasible nondominated designs, all satisfying the 12 prescribed poses. Actuator-mass coupling converges in three iterations for every reported design. A fixed-design ablation shows that one-pass sequential sizing changes hardware mass by up to 2.13%, co-design cost by 10.20%, and supply energy by 9.40% in magnitude. Payload screening further reveals increasing mass-cost-energy demand and changes in competitive mechanism topology with carried load.

0.45

Lithium Niobate Surface-Acoustic-Wave Resonator for Very-High-Frequency Isolated Power Conversion

eess.SY physics.app-ph ·2026-10-02 ·Liyang Jin, Zhiyang Cao, Zichen Xi, Jun Ji, Yizheng Zhu +2 more
unusual similarity 0.34
Abstract

Piezoelectric devices offer a promising magnetic-free alternative for high-frequency power electronics, enabling compact energy transfer with inherent galvanic isolation. Here we demonstrate a lithium niobate surface acoustic wave (SAW) resonator that enables isolated power transfer and addresses the challenges in existing piezoelectric devices for power applications, including operation frequencies, power delivery figure of merit (FOM), power handling, and electrical isolation. Our application-optimized 40-MHz SAW resonator, with the two electrically isolated interdigital transducers (IDTs) and acoustic Bragg mirrors, achieves a 25.7 W output power at a less than 15 °C temperature rise with only passive cooling through the back mounting side, and an isolation voltage of 2.17 kV. In DC-AC power conversion, we demonstrate a peak efficiency of 93.8 %, a power delivery FOM of 13.47 mW/V$^2$ and a peak chip power density of 81.7 W/cm$^3$. DC-DC conversion is also demonstrated by connecting a diode rectifier to the output IDT, despite efficiency degrading to 52.7 %. Our results advance SAW devices as one of the core components for next-generation very-high-frequency, miniaturized, high-density, magnetic-free, isolated power converters.

0.26