Transformer-guided Variable Projection for Phasor and Fault-Time Estimation Under DDC Offset

Marcus Chen I Wada, Sina Mohammadi, Van-Hai Bui, Wencong Su

eess.SY ·submitted 2026-11-02 16:38 UTC · v1
unusual

Abstract

Decaying DC (DDC) offsets introduce substantial phasor estimation errors during the first post-fault cycle. Recent approaches have sought interpretable waveform representations, but identifying analytical expressions can incur substantial computational costs. This paper proposes a transformer-guided variable-projection estimator that extracts the fundamental phasor, DDC parameters, and fault inception time from point-on-wave (POW) samples as an interpretable analytical expression. An offline-trained transformer provides the signal structure and decay rate, while variable projection refines the parameters and handles windows containing the fault without knowledge of time of fault. Across single- and dual-DDC scenarios with time constants of 2.5--400~ms, the mean maximum overshoot (MO) is at most 2.7% on post-fault windows and 2.2% during online operation, where the DFT reaches 10--14%. The post-fault phasor settles within 5% approximately 12.5~ms after inception. Circuit-level validation on a 230-kV two-source system yields 1.6% mean MO, compared with 9.5% for the DFT.

Comment
5 pages, 3 figures, 3 tables. Submitted to PESGM

Closest papers

Nearest neighbours by meaning across the whole index.

An Accurate Modulation-Assisted Method for Phasor Estimation Under Decaying DC Offsets

eess.SY ·2026-11-10 ·Sina Mohammadi, Apurv Shukla, Junho Hong, Wencong Su
similarity 0.67
Abstract · This work has been submitted to the IEEE TPWRD for possible publication. Copyright may be transferred without notice, after which this versi…

Decaying DC (DDC) offsets severely compromise the accurate estimation of current phasors immediately following power grid fault occurrence. Consequently, conventional full-cycle discrete Fourier transform (FCDFT) algorithms experience decaying oscillatory magnitude errors, potentially causing distance relays to malfunction. This paper introduces a modulation-assisted technique designed to precisely eliminate the DDC components from fault current signals. By multiplying the fault signal with a high-frequency carrier and applying consecutive sliding Fourier projections, the proposed method effectively isolates the DDC signal while entirely rejecting higher-order harmonic interference. It utilizes a direct algebraic solution derived from a robust forward-difference operation across just three sequential projections to estimate and extract the DDC parameters. Furthermore, the algorithm seamlessly processes both single and multiple DDC components by dynamically tracking them as one equivalent first-order mode. Extensive evaluations are conducted to validate the proposed method accuracy. The proposed algorithm limits the maximum overshoot (MO) to 0.62% (0.59% for $k \geq 8$) for the evaluated DDC cases, and to 2.47% (0.95% at 20 dB for $k = 8$) under noisy conditions.

0.19

The Price of a Cycle: A Phasor -vs- Sampled-Value Comparison for Streaming Fault Classification on the IEEE 9-Bus System

eess.SY ·2026-10-03 ·Emad Abukhousa, Khaled Muhmmed Nor Muhmmed, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmark similarity 0.52
Abstract

Transmission-line fault classification is a time-critical protection function, and recent machine-learning methods classify fault type directly from voltage and current measurements. The input to such a classifier can be supplied as sampled-value windows of raw measurements, which preserve sub-cycle structure, or as phasor-domain sequence components, which are physically interpretable but require a causal one-cycle observation window before a phasor estimate is available. This paper measures the cost of that observation window, the price of a cycle, through a controlled comparison of the two representations for streaming fault-family classification on the standard synchronous WSCC/IEEE 9-bus system. The comparison holds the simulated system, the measured channels, the eleven-class event-family taxonomy, the training procedure, and the streaming decision layer constant, and uses six configurations: 40- and 80-sample sampled-value inputs and one-cycle phasor inputs, each evaluated with a multilayer perceptron (MLP) and a one-dimensional convolutional neural network (CNN). All six configurations classify every event successfully, yet the sampled-value representation reaches the correct class earlier in every model pair. The 40-sample sampled-value MLP attains the strongest result, with 99.34% fault-window accuracy, 99.79% normal accuracy, a 0.21% false-fault rate, a 0.65% false-normal rate, and a 2.81 ms mean first-correct delay, and it Pareto-dominates the other five configurations. A matched-window comparison at eighty samples confirms that the timing advantage follows from the representation rather than from the window length. On this clean synchronous benchmark, the one-cycle phasor representation does not return an accuracy or stability benefit sufficient to offset its delay.

0.31

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.51
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

Understanding the limits of snapshot-based fault diagnosis in distribution networks

cs.AI ·2026-11-13 ·Ba Tu Phung, Huy Hoang Le, Kim-Anh Nguyen
similarity 0.51
Abstract

Inverter-based resources weaken fault currents in distribution networks, and snapshot-based diagnosis, which classifies a fault from voltage phasors at a few buses at one instant, offers a cheap first-stage screen. Its published accuracies, however, rest on different noise assumptions and do not show whether the error comes from the classifier, the features, the measurement error, or the fault resistance. This paper separates these sources on three IEEE test feeders and a public data set with distributed generation, using four feature sets, thirteen classifiers, and measurement error defined by total vector error classes. The classifier is not the limiting factor, because the full phasor snapshot classifies every fault correctly without noise, and the remaining error comes from measurement error on high-impedance faults. Three voltage sensors classify 90-96% of faults at the 1% accuracy class and 96-99% with distribution micro phasor measurement units (micro-PMUs). A discriminability-margin placement selects them from simulations alone in under one second and matches the best of twelve placement methods. The results show when snapshot-based diagnosis can be trusted.

0.25

TRACK: Tool-Augmented Reasoning over Time Series for Fault Diagnosis in Power Management System

cs.LG cs.AIcs.CLeess.SY ·2026-11-16 ·Erkan Bayram, Debanjan Ghosh, Li Zhu, Sambarta Dasgupta
benchmark similarity 0.50
Abstract

Fault diagnosis in power management systems running multiple loads relies on experts manually inspecting current and voltage waveforms, which fails to scale across deployed units. We present TRACK, which pairs a time series encoder with a Small Language Model to produce structured, physics-grounded diagnostic reports, calling tools for exact, verifiable calculations. It operates on-device, keeping proprietary sensor data local and avoiding expensive API calls. We introduce a rubric-based framework that evaluates these reports by scoring structure, signal fidelity, physics reasoning, diagnosis, and actionability through per-criterion verdicts. On a 15-class multi-load simulated benchmark, TRACK achieves over 95% fault-category accuracy and generalizes to out-of-distribution faults, whereas the best encoder-probing baseline reaches only 58% accuracy.

0.24

From Winding-Fault Geometry to Reliability: Estimation and Prognosis of Stator Inter-Turn Faults

eess.SY eess.SP ·2026-09-11 ·Bambang L. Widjiantoro, Syahrul Munir, Katherin Indriawati, Moh Kamalul Wafi
benchmark similarity 0.49
Abstract

This paper develops an integrated framework for estimation, prognosis, and reliability assessment of stator inter-turn faults in induction motors. The fault is characterized by its severity, defined as the fraction of short-circuited turns, and its spatial orientation. A geometric fault model shows that the resulting output signature is affine in the fault severity and exhibits a fundamental spatial periodicity. Exploiting this structure, an augmented-state particle filter jointly estimates the nonlinear electromechanical state and the unknown fault severity while quantifying posterior uncertainty. The estimated degradation is then propagated using four prognostic models: linear trend, Holt exponential smoothing, Bayesian degradation, and particle-based forecasting. Their predictions are connected to threshold-crossing remaining useful life (RUL), first-passage reliability, degradation-dependent hazard reliability, and a Weibull lifetime benchmark, thereby providing both deterministic and probabilistic health assessments. Numerical results demonstrate accurate online fault estimation and output reconstruction, characterize the effects of degradation pattern and prediction horizon on prognosis, and show consistent reliability and threshold-crossing predictions. Moreover, estimation accuracy remains comparable across the distinct fault orientations induced by the spatial periodicity. The resulting framework provides a unified connection from physics-based inter-turn fault modeling to online diagnosis, degradation prognosis, and reliability assessment.

0.25

Data-Driven Generator Transient Prediction for Digital Twin Decision Support

eess.SY eess.SP ·2026-09-04 ·Emad Sadeghi, Emerson Miller, Kerry Sado, Adel Nasiri
similarity 0.48
Abstract · In submission for possible publication in IEEE Transactions on Power Systems

This paper develops a calibrated transient forecasting surrogate model for generator digital twin (DT) decision support that evaluates planned active- and reactive power load commands before they are applied. The proposed event-conditioned Hankel Dynamic Mode Decomposition with Control (Hankel-DMDc) model combines delay-coordinate lifting, command-event memory features, and an event-weighted Hankel basis so that sparse load-transition dynamics influence the reduced representation and fitted dynamics. This design targets intervals where voltage/frequency deviations and recovery behavior determine whether a candidate load command keeps the system within acceptable limits. To provide operator-facing confidence information, a split-conformal calibration layer is applied to the frozen surrogate model to form event-conditioned joint prediction bands for voltage and frequency. The experimental results show event-window root-mean-square errors of 1.058 V and 0.155 Hz. For a nominal 90% target, the bands attain 90.17% pointwise joint voltage-frequency coverage, with mean band widths of 3.55 V and 0.566 Hz. A 50-s open-loop rollout is computed in 181 ms on a single CPU core, approximately 280 times faster than real time, with forecast accuracy evaluated over horizons up to 5 s. These results demonstrate a computationally efficient advisory framework for generator DTs that combines transient prediction with calibrated uncertainty.

0.25

On PMU Adequacy for Wideband Dynamics Tracking Beyond Attenuation Assumptions

eess.SP ·2026-11-06 ·Chetan Mishra, Luigi Vanfretti, Jaime Delaree Jr. and, Kevin D. Jones
similarity 0.48
Abstract

Recent work highlights the inadequacy of standard synchrophasors in capturing high-frequency grid dynamics, including data center oscillations, primarily due to filtering and windowing attenuation during phasor estimation. This letter shows how synchrophasor ambient data spectrum itself contains information on attenuation, which provides a way to identify critically impacted measurements and potentially estimate and undo the effect. Results are shown for synthetic data as well as actual synchrophasor estimates from digital fault recorders (DFRs) within the Dominion Energy system.

0.14