Purpose: To develop and evaluate a fully automated, open-source tool that measures aortic diameters at 11 standardized landmarks from the aortic annulus to the bifurcation on any CT image, following current guideline recommendations. Materials and Methods: This retrospective single-center study included 239 arterial phase CT angiography examinations of 230 patients (median age, 65 years [range, 18-99 years]; 163 men) performed between April 2025 and October 2026 (209 electrocardiographically [ECG] gated). The tool locates landmarks from TotalSegmentator segmentations of aortic branches and vertebrae and measures the maximum diameter at each. A senior radiologist reviewed and, where needed, corrected the automated measurements to create the reference standard. Agreement was assessed with mean absolute error (MAE), bias, and differences greater than 2 mm. Results: Across all landmarks, MAE was 1.06 mm (95% CI: 0.91, 1.22), and 86.6% (95% CI: 84.4, 88.5) of differences were 2 mm or less. The tool measured slightly larger diameters (bias, 0.45 mm [95% CI: 0.34, 0.57]). The sinuses of Valsalva had the largest MAE (2.17 mm [95% CI: 1.59, 2.86]). For 1.2% of landmarks, the automatic measurement failed. Examination-level MAE did not differ significantly by pathology, atherosclerosis grade (P=.95), or ECG gating (P=.14). Examinations with mural thrombus more often had an MAE greater than 2 mm (50% [95% CI: 31, 69] vs 20%; P=.03). Conclusion: The tool measured aortic diameters at 11 landmarks along the entire aorta with an MAE of about 1 mm, below published interreader variability. Agreement was lower at the aortic root and with mural thrombus. Code availability: The tool is open source and freely available at https://github.com/wasserth/TotalSegmentator.

Closest papers

Nearest neighbours by meaning across the whole index.

A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening

cs.CV cs.AI ·2026-11-10 ·Sharan Sharmeela Karuppannan, Yoga Sri Varshan, Subin Sahayam, Umarani Jayaraman
published similarity 0.53
Abstract · Accepted for presentation at the 23rd IEEE India Council International Conference (INDICON 2026)

The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.

0.32

Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates

cs.AI cs.LG ·2026-09-14 ·Ali Nourbakhsh, Mohammad Reza Niroomand, Erfan Nourbakhsh
code/data similarity 0.52
Abstract · 8 pages, 6 figures, Under review at ICBME 2026

Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion

0.43

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

eess.IV cs.CV ·2026-11-06 ·Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia +6 more
code/data similarity 0.52
Abstract · 52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

0.45

Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

cs.CV ·2026-09-03 ·Hinrich Rahlfs, Julio Garcia, Chiara Manini, Markus Hüllebrand, Sebastian Schmitter +11 more
code/data similarity 0.51
Abstract · Submitted to Journal of Cardiovascular Magnetic Resonance

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

0.45

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.51
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

eess.IV cs.CV ·2026-09-11 ·Benjamin Jin, Maria del C. Valdés Hernández, Richard Bortsov, Joanna M. Wardlaw, Daniel Bos +1 more
publishedcode/data similarity 0.49
Abstract · Accepted at the Stroke and neurovascular diseases Workshop on Imaging and Treatment CHallenges @ MICCAI 2026

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

0.45

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

cs.AI ·2026-08-29 ·Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To +5 more
code/data similarity 0.49
Abstract

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

0.43

Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI Assessment

eess.SP ·2026-11-09 ·Haowan Wang, Cheng Ding, Donglin Xie, Huizi Yu, Guangkun Nie +3 more
similarity 0.48
Abstract

Access to echocardiography is often limited, delaying recognition of progressive aortic stenosis (AS). A brief, low-cost physiological measurement obtained during routine care could help identify patients who may warrant earlier imaging. Here, we present PulseAS, integrating deep photoplethysmography (PPG) representations, waveform biomarkers and clinical information for high-grade AS screening. Three complementary analyses assessed (1) validation and transfer across cohorts differing in geography and ethnic composition, (2) score-based enrichment of AS and pre-transcatheter aortic valve implantation (TAVI) cases, and (3) preoperative and postoperative pulse changes. Using 15-s recordings, separate patient-level cross-validation in EDU (n = 1,209) and MIMIC-III (n = 2,970) yielded AUROCs of 0.818 (PulseAS-XGB) and 0.838 (PulseAS-L2), respectively. In external validation from MIMIC-III to EDU, PulseAS-XGB achieved an AUROC of 0.716, improving to 0.813 after local adaptation. The highest-scoring 10% captured 45.2% of all high-grade AS cases in EDU and 41.3% in MIMIC-III, and 56.9% of pre-TAVI cases in EDU. Notably, in the EDU TAVI subgroup, PPG waveforms showed earlier systolic peaks and narrower systolic contours following intervention. These findings support clinical-PPG risk stratification in new populations and warrant prospective evaluation of echocardiographic prioritisation.

0.29