CS Paper Radar

Optical Motion Sensing for Piezoelectric-Resonator-Based Power Converters

Liyang Jin, Zhiyang Cao, Jun Ji, Liyan Zhu, Linbo Shao

eess.SY physics.optics ·submitted 2026-11-21 20:45 UTC · v1
unusual

Abstract

Piezoelectric components present a promising alternative to conventional magnetics for miniaturized, high-frequency power converters. While high-Q piezoelectric resonators have demonstrated high efficiencies and large power densities in prototype high-frequency dc-dc converters, their optimal operating conditions are sensitive to temperature fluctuations and load variations. Therefore, robust closed-loop control is essential for practical deployment. Electrical approaches for sensing motional current may compromise the electrical isolation and electromagnetic interference (EMI) immunity inherently provided by the mechanical nature of these resonators. Here, we present an optical motion sensing approach for piezoelectric power converters. The optical sensing system comprises a laser, fiber optics, and a photodetector. The proposed approach uses optical interference to monitor the mechanical displacement in real time. The resulting optical signal carries both the amplitude and phase of the mechanical motion, which are necessary for closed-loop control. We experimentally characterize and validate this optical motion sensing approach using a 45-kHz piezoelectric resonator driven by a GaN half bridge with input voltages up to 45 V. We further experimentally demonstrate closed-loop control using the proposed optical motion sensing for a 99-kHz isolated piezoelectric converter. These initial results establish a viable pathway toward optically closed-loop control of piezoelectric power converters.

Closest papers

Nearest neighbours by meaning across the whole index.

Lithium Niobate Surface-Acoustic-Wave Resonator for Very-High-Frequency Isolated Power Conversion

eess.SY physics.app-ph ·2026-10-02 ·Liyang Jin, Zhiyang Cao, Zichen Xi, Jun Ji, Yizheng Zhu +2 more
unusual similarity 0.52
Abstract

Piezoelectric devices offer a promising magnetic-free alternative for high-frequency power electronics, enabling compact energy transfer with inherent galvanic isolation. Here we demonstrate a lithium niobate surface acoustic wave (SAW) resonator that enables isolated power transfer and addresses the challenges in existing piezoelectric devices for power applications, including operation frequencies, power delivery figure of merit (FOM), power handling, and electrical isolation. Our application-optimized 40-MHz SAW resonator, with the two electrically isolated interdigital transducers (IDTs) and acoustic Bragg mirrors, achieves a 25.7 W output power at a less than 15 °C temperature rise with only passive cooling through the back mounting side, and an isolation voltage of 2.17 kV. In DC-AC power conversion, we demonstrate a peak efficiency of 93.8 %, a power delivery FOM of 13.47 mW/V$^2$ and a peak chip power density of 81.7 W/cm$^3$. DC-DC conversion is also demonstrated by connecting a diode rectifier to the output IDT, despite efficiency degrading to 52.7 %. Our results advance SAW devices as one of the core components for next-generation very-high-frequency, miniaturized, high-density, magnetic-free, isolated power converters.

0.26

Non-Imaging Optical Tactile Sensors for Robotics: Transduction Principles, System Integration, and Robotic Applications

cs.RO ·2026-11-16 ·Hao Wu, Yu Feng, Haotian Guo, Huichan Zhao, Changsheng Wu +1 more
similarity 0.49
Abstract · 35 pages, 9 figures

Non-imaging optical tactile sensors encode contact through changes in optical intensity, wavelength, spectra, or photon counts, offering diverse architectures for robotic touch. Their usefulness depends on whether contact variables can be reliably distinguished from coupled mechanical and environmental effects, and whether the resulting information can be delivered in time to guide action. This review develops a unified framework linking mechanical load transmission, optical encoding, readout, and tactile inference to robotic task requirements. It examines reflective and waveguide-based devices, micro/nanofibers, fiber gratings, interferometric and resonant structures, and mechanoluminescent composites. Three considerations emerge across these approaches. First, high optical sensitivity supports accurate tactile estimation only when target variables remain identifiable under the relevant contact and calibration conditions. Second, spatial coverage and feedback timing must be assessed at the system level, accounting for multiplexing, acquisition, demodulation, and inference. Third, device characterization, offline recognition, and closed-loop robotic performance provide distinct levels of evidence and require different evaluation criteria. Representative studies illustrate how these considerations shape force estimation, contact localization, slip correction and distributed interaction. This review concludes with priorities for calibration transfer, reliable interfaces, scalable readout, and task-based validation, providing a basis for selecting and developing non-imaging optical tactile architectures for robotics.

0.16

13,000-Fold Frequency Down Conversion From 280 MHz to 21 kHz Using Mechanical Frequency Combs

eess.SP ·2026-11-05 ·Ian Anderson, Zihuan Liu, Vivek Tallavajhula, Yen-Chen Wang, Tzu-Hsuan Hsu +2 more
unusual similarity 0.48
Abstract · 4 pages, 6 figures

Optical frequency combs bridge the microwave and terahertz regimes by down-converting terahertz optical energy into microwave signals. A photodetector converts the comb's equally spaced lines, generated through optical nonlinearities, into a low-frequency tone at their spacing. Here, we present the first mechanical version of this process, using mechanical frequency combs to downconvert energy over 4 orders of magnitude, from the MHz to kHz regime. Thin-film lithium niobate (LN) is used to design an acoustic resonator with a wide range of mode frequencies. We achieve phononic comb excitation from 250 MHz to 900 MHz and compare the electrical and laser Doppler vibrometer (LDV) measurements at 277 MHz. We then show the low-frequency spectrum of the devices, highlighting mechanical motion at the comb's spacing and demonstrating energy transfer from 277 MHz to 21 kHz.

0.30

A Monolithic Force-Proprioception Soft Acutuator Enabled by Single-Material 3D printing

cs.RO ·2026-09-21 ·Nan Huang, Lele Liu, Junfeng Lu, Yipan Zhu, Jiansheng Dai +1 more
similarity 0.42
Abstract

Pneumatic proprioceptive actuators integrate actuation and sensing for soft robots that attract interest due to functional potential. Existing approaches often suffer from assembly errors or stress concentrations caused by heterogeneous materials. In this work, we propose the Monolithic Force-Proprioception Soft (MFPS) design and fabrication method that integrates an Asymmetric Origami Bending (AOB) chamber and a Force-Proprioception Soft (FPS) sensor with single material through one-step Fused Deposition Modeling (FDM) fabrication. Based on the resistance response to strain of conductive thermoplastic polyurethane (TPU), we design and analyze the structure of the FPS sensor, and conduct parametric analysis on the sensing characteristics. The FDM fabrication parameters of the MFPS actuator are analyzed, followed by actuator fabrication and characterization of the actuation and proprioception performance. Experimental results show that the MFPS actuator achieves a bending angle of 40°, an output force of 12.5 N, and a resistance change of 26.9% as the applied external force increased from 0 to 45 N. A two-finger force-proprioception gripper is developed based on the MFPS actuator. The grasping and force-proprioception capabilities are experimentally validated, proving that the MFPS design method provides a new approach for the development of self-sensing actuators.

0.20

Damping Oscillations in a Spherical Pendulum Inclinometer Using Vector-Based Control

eess.SY ·2026-08-31 ·Fernando Capes, Mikael Andreas Bianchi, Roberto Gardenghi, Manuel Alò
similarity 0.41
Abstract

This paper addresses disturbance-induced oscillations in high-precision pendulum-based inclinometers, which reduce measurement availability despite the long-term stability of gravity-referenced sensing. To actively suppress these oscillations, a contactless six-coil electromagnetic actuation system is developed, together with a control framework that generates, in real time, the planar damping force required by the controller despite the nonlinear, unilateral, and bounded nature of magnetic actuation. The proposed approach combines a control-oriented nonlinear model of the spherical pendulum, observer-based feedback control, and a constrained force-allocation scheme that maps the desired vector force into feasible coil currents. Experimental validation on a prototype demonstrates attenuation of the dominant oscillatory mode up to 31.11 dB and a marked reduction in transient duration, with the 50\% decay time decreasing from 11.10 s without control to 1.01 s at the most favorable operating point. The results also highlight a trade-off between transient speed and residual oscillation, demonstrating both the effectiveness of the proposed damping strategy and its value as a practical design framework for high-precision inclinometer systems.

0.25

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

eess.AS ·2026-10-13 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
benchmark similarity 0.41
Abstract · 14 pages

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

0.09

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

cs.RO ·2026-11-04 ·Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, Jianshu Zhou
similarity 0.41
Abstract

Integrating six-axis tactile feedback into robotic interfaces requires compact sensors with accurate load measurement and rapid online reconstruction. This paper presents LumiTac, a low-profile, camera-free optoelectronic tactile sensor combining spatially distributed illumination with spectral encoding. Five photoemitters and five RGBW photoreceivers are mounted on opposing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical channels. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small forces, and transient response, respectively. Robotic demonstrations further validated its applicability to tactile-guided manipulation and physical human-robot interaction. This study paves the way for compact, high-rate optical tactile sensing in robotic manipulation and human-robot interaction.

0.45

Topology optimisation and simulated state reconstruction for self-sensing piezoresistive grippers

cs.CE ·2026-09-13 ·Connor N Mallon, Zachary J Wegert, Anthony P Roberts, Joshua Pinskier, Harry Bowman +1 more
similarity 0.41
Abstract

We consider the computational design of a self-sensing robotic gripper that has the potential to reduce reliance on traditional external sensors. We computationally investigate the potential of a novel sensing method that exploits the coupled electromechanical properties of piezoresistive materials to enable mechanical perception using sparse electrical measurements. In this theoretical proof-of-concept, we show that under the idealised assumptions of linear constitutive relationships and quasi-static gripper operation, it is possible to reconstruct simple contact shapes and gripper displacement fields using a small number of simulated electrical measurements, suggesting the potential of the proposed sensing technique. We use topology optimisation to promote the quality of displacement state recovery by adding an electrical performance objective to the mechanical compliance requirement of the gripper. Using the proposed reconstruction technique, we showcase the improved reconstruction ability of an electrically optimised gripper design through an increased robustness to noisy synthetic measurements compared to a gripper designed with only a mechanical objective in the topology optimisation problem. In the future, detailed inclusion of non-linear effects and experimental realisation of this theoretical proof-of-concept may help remove the constraints of traditional sensors for robotic handling, potentially facilitating sensing in settings where current sensing systems are impractical.

0.29