CS Paper Radar

Weekly top 20 · eess.IV

2026-W33 Aug 10 – Aug 16, 2026

Ranked from 3,675 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Hybrid-LUT: Channel-Aware Hybrid Lookup Table and Filtering for Efficient Image Denoising

cs.CV eess.IV ·2026-08-12 ·Zhilin Ai, Boyu Li, Sidi Yang, Wenqing Shi, Wenyong Zhou +3 more
top venuecode/data
Abstract · Accepted by ECCV2026

Lookup table (LUT)-based image denoising methods have attracted increasing attention due to their high efficiency and hardware-friendly properties. However, existing RGB-LUT approaches require three identical LUTs to process RGB channels in parallel, resulting in large on-chip SRAM consumption. A simple alternative is to apply LUT processing only to the luminance (Y) channel in the YUV color space to reduce memory usage. However, this naive strategy leads to degraded restoration quality, since ignoring the chrominance (UV) channels introduces color distortion and residual artifacts. In this work, we propose Hybrid-LUT, a YUV-based asymmetric channel-processing framework that combines LUT and filtering in a unified design. Specifically, a multi-band LUT branch with pixel-level weight fusion is applied to the Y channel to recover fine textures, while lightweight filtering is used for the UV channels to maintain color consistency. This design reduces LUT storage by two-thirds compared with RGB-LUT methods while maintaining the same runtime throughput. Extensive experiments show that Hybrid-LUT achieves state-of-the-art (SOTA) performance across multiple benchmarks with only 421 KB of storage. In particular, our method surpasses existing LUT-based denoising approaches by at least 0.63 dB CPSNR on real-world datasets, demonstrating its effectiveness for image denoising on resource-constrained edge devices. The project is available at https://github.com/Ai-ZL/Hybrid-LUT .

0.84
2

Dual-Domain Cross-Modal Decoding for Clinical Text-Guided Medical Image Segmentation

cs.CV cs.AIeess.IV ·2026-08-11 ·Md Maklachur Rahman, Tracy Hammond
top venuecode/data
Abstract · Accepted at MICCAI 2026 (Main). Final version to appear in the MICCAI 2026 proceedings

Clinical text can narrow down what to segment, but recent text-guided designs emphasize spatial alignment while overlooking frequency content that governs texture and boundaries. We propose Dual-Domain Cross-Modal Decoding (DD-CMD) for clinical text-guided pulmonary infection segmentation, integrating two complementary forms of language guidance during decoding. In the spatial domain, Text-Guided Spatial Cross-Attention (TGSA) aligns multi-scale visual tokens with text semantics and updates features through gated residual fusion. In the frequency domain, Spectral-Text Adaptive Modulation (STAM) applies a 2D DCT to compute learnable band-energy statistics and predicts text-conditioned FiLM parameters to recalibrate decoder channels for frequency-aware decoding. DD-CMD embeds TGSA and STAM into a coarse-to-fine decoder (7x7 to 56x56) and restores full-resolution masks using a lightweight two-stage refinement module. Experiments on QaTa-COV19 and MosMedData+ show that DD-CMD achieves 91.46% Dice / 84.26% mIoU and 81.95% Dice / 69.42% mIoU, respectively, with average gains of +1.96 Dice and +2.67 mIoU over the strongest prior baselines. Code: https://github.com/maklachur/DD-CMD.

0.84
3

From crown candidates to neighborhood screening: integrating optical GeoAI and spatial modeling for urban-canopy assessment in Davis, California

eess.IV cs.CVstat.AP ·2026-08-14 ·Mohammadreza Narimani, Shreyan Mitra, Parastoo Farajpoor
code/datahighly cited
Abstract · 17 pages, 10 figures + 5 supplementary figures, 7 tables. Revised preprint (expanded canopy infill; IoU 0.719). Preprint submitted to Taylor…

Timely urban-canopy information is essential for linking remote sensing with heat, mobility, and neighborhood planning. We developed an optical GeoAI workflow for Davis, California, using 2022 National Agriculture Imagery Program imagery (0.6 m RGB+NIR). DeepForest generated crown candidates; an NDVI threshold, non-maximum suppression, and box-prompted Segment Anything Model (ViT-B) produced a crown-anchored canopy surface. Analyses used the 25.92 km2 Census TIGER municipal boundary and a 100 m grid. The workflow retained 11,741 candidate crowns and mapped 7.71 km2 of canopy (29.8% of the city). On the identical extent, pixel precision was 0.804, pixel recall was 0.873, and 97.4% of candidate centers agreed with the 2022 USDA/CAL FIRE LiDAR-assisted canopy product (IoU 0.719; Dice 0.837; area recovery 108.5%). Approximately 49% of candidates occurred within 15 m of a road. Canopy was inversely associated with Landsat land-surface temperature (Spearman rho = -0.477; partial rho = -0.551 controlling for built probability), and spatial-lag modeling confirmed clear neighborhood structure. Two transparent attention surfaces combined canopy need with thermal and contextual indicators. The framework provides a reproducible, updateable screening layer that complements structural canopy products and municipal inventories while retaining assumptions, data provenance, and spatial diagnostics for planning interpretation.

0.70
4

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation

cs.HC cs.LGcs.ROeess.IV ·2026-08-11 ·Kenta Yokoe, Takuya Hara, Tadayoshi Aoyama
published
Abstract · This is the accepted version of an article published in IEEE Access 13, 182915-182923 (2025). DOI: 10.1109/ACCESS.2025.3624246. Open Access …

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

0.62
5

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

eess.IV cs.CV ·2026-08-14 ·Yuanchao Bai, Yifan Zhao, Kai Wang, Yuanbo Du, Jie Cheng +3 more
published
Abstract

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

0.60
6

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59
7

ResPCC: A Loss-Resilient Neural Point Cloud Codec over Lossy Networks

eess.IV cs.MM ·2026-08-12 ·Xueqin Niu, Mufan Liu, Yifan Wang, Le Yang, Jun Sun +1 more
top venuecode/data
Abstract

Point cloud compression (PCC) is critical for efficient storage and transmission of 3D data. While recent learning-based PCC methods achieve good rate-distortion (R-D) performance, they generally rely on ideal transmission conditions. In practice, packet loss is a common issue and can severely distort latent features, causing coordinate drift and geometric degradation. To address this challenge, we present ResPCC, the first end-to-end neural point cloud codec designed to offer intrinsic resilience against data loss. Our framework is loss-rate-aware and adapts to diverse packet loss conditions. At the encoder, we introduce a Condition-Adaptive Latent Modulation (CALM) module to adjust latent feature distributions according to the perceived loss rate, as well as a Spatial-Channel Interleaving (SCI) mechanism that transforms channel-wise data extinction into spatially scattered element-wise missing patterns. At the decoder, we develop a Mask-Aware Graph-based Latent Restoration (MGLR) module, followed by a Dictionary-based Refinement (DBR) stage to recover corrupted features and align them with canonical priors. Evaluations on ShapeNet and SemanticKITTI under 5\% to 30\% packet loss rates show that ResPCC consistently delivers superior stability and R-D performance over baselines. Our framework maintains high reconstruction fidelity under lossy conditions, providing a reliable solution for 3D data transmission over practical networks. Code is available at https://github.com/starrynight314/ResPCC.

0.54
8

Geometry-Based Compression of Plenoptic Point Clouds

eess.IV cs.CVcs.MM ·2026-08-11 ·Davi R. Freitas, Gustavo L. Sandri, Ricardo L. de Queiroz
Abstract

Plenoptic point clouds (PPC) are novel data structures that represent the light from different viewing directions in order to provide a higher degree of realism to regular point clouds. This is achieved by associating each point to multiple colors instead of a single one. Here, we present a method to efficiently compress the attributes of a PPC, consisting of a Karhunen-Loève transform over the color attributes followed by multiple attribute coders with intra prediction capability. This compression scheme can be incorporated within the MPEG's geometry-based PCC (G-PCC) standard, using any of G-PCC's existing solutions for attribute coding. Compression performance assessment using PPCs of different spatial resolutions reveals competitive results in comparison to existing methods, such as RAHT-based or video-based PCC solutions. We believe our coder to be the new state of the art.

0.50
9

Lost in k-Space: An Open-Source MR-Physics Escape Room

eess.IV physics.med-ph ·2026-08-10 ·Sabine Melanie Räuber, Marta Brigid Maggioni, Francesco Santini
publishedcode/data
Abstract · 15 pages, 3 figures

Introduction. Operating an MR scanner for technical and clinical research requires multidisciplinary competencies beyond MR physics, including safety management and teamwork. Gamification, particularly educational escape rooms, have been associated with improved motivation, engagement and knowledge retention in health professional education. Materials and Methods. We developed an MR-physics-themed educational escape room for the 41st Annual Meeting of the ESMRMB. Designed for teams of four with a time limit of 25 minutes, the room reproduced the atmosphere of an MR control room. The five puzzles covered the Larmor equation, sequence composition, MR safety and acoustical identification of MR sequences. Custom ESP32 electronics allowed the puzzles to communicate in real time with each other and with the game master Results. The room ran without technical interruptions and was played by 39 teams (approximately 160 participants); 12 solved it (escape rate 31%), with a median solution time of 21 minutes and 53 seconds. Early-career researchers acted as game masters. Discussion. The escape rate aligns with comparable activities targeting scientific audiences. Difficulty can be tuned by adjusting puzzle obscurity, component availability, required prior knowledge and mental leaps. A modified version could usefully supplement mandatory MR safety training. Code, schematics, machining files and documentation are released as open source.

0.44
10

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42
11

TractoGraphVLM: A Unified Vision-Language Framework for White Matter Tractography

eess.IV cs.CV ·2026-08-16 ·Gurucharan Marthi Krishna Kumar, Janine Dale Mendola, Amir Shmuel
publishedcode/data
Abstract · Accepted as a Spotlight at the ECCV 2026 Workshop on Artificial Intelligence for Medical 3D Vision (AI4M3D). Our codebase, including all tra…

Vision language models have transformed 2D medical imaging, yet extending them to 3D white matter tractography remains challenging due to the complex topology of fiber bundles. We introduce TractoGraphVLM, a unified framework for four tasks, bundle classification, text-to-tract retrieval, anatomical captioning, and visual question answering, built on a shared GPS architecture, training procedure, and read-out design. Fiber bundles are represented as streamline graphs whose nodes encode 3D position and tangent orientation. A General, Powerful, Scalable (GPS) graph transformer produces bundle embeddings aligned with a frozen BiomedBERT text encoder via contrastive learning, while a BioGPT decoder with visual prefix tokens generates captions and answers. A single shared encoder and decoder is trained jointly across all four tasks and evaluated from one checkpoint. Trained on HCP Young Adult subjects, TractoGraphVLM achieves 91.8% bundle classification accuracy, 84.7% retrieval R@1, BLEU-4=20.1, ROUGE-L=66.8, and 66.4% VQA accuracy on a held-out test set. The same checkpoints transfer zero-shot to HCP Aging subjects, with a modest drop on discriminative tasks and a larger drop on generative tasks, showing robustness to age and acquisition shift. Language supervision yields richer representations than label-only training, recovering structure like hemisphere and fiber family, carried by captions but never given as a label. Swapping only the visual encoder, graphs preserving fiber orientation outperform volumetric baselines, with GPS giving the best balance. Generative metrics measure consistency with a structured knowledge base rather than independent clinical text; even so, TractoGraphVLM shows that classifying, retrieving, describing, and answering questions about a white matter bundle can be served by one jointly trained model that learns transferable neuroanatomy from language alone.

0.40
12

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays

eess.IV cs.CVcs.LG ·2026-08-11 ·Harshil Lodhiya
Abstract · 21 pages, 8 figures Included declaration for paper is under consideration at Pattern Recognition Letters

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

0.40
13

ENAF: A Multi-Exit Network with an Adaptive Patch Fusion for Large Image Super Resolution

cs.CV cs.AIeess.IV ·2026-08-15 ·Duong M. Nguyen, Tuan Nghia Nguyen, Xuan Truong Nguyen
publishedcode/data
Abstract · Accepted at WACV 2025

To accelerate single image super-resolution (SISR) networks on large images (2K-8K), many recent approaches decompose an image into small patches and dynamically determine an execution path according to its difficulty (referred to as a dynamic network). To quantify the hardness of a patch, they mainly rely on a handcrafted assessment score, e.g., edge, which weakly associates a patch's texture with the computational complexity of a SISR model. To address the problem, we introduce ENAF - a dynamic network for SISR with an adaptive patch fusion. Built on top of a backbone, ENAF incorporates multiple early exits (EEs) to tackle the over-parameterized SISR model. More importantly, ENAF plugs a tiny network that estimates PSNR to associate data texture with a computation cost at an EE. Based on the scores, ENAF effectively assigns image patches to an exit, enhancing the quality-complexity trade-off. Extensive experiments on common datasets with popular SISR backbones demonstrate the effectiveness of ENAF in various settings. The source code is provided in https://github.com/nmduonggg/ENAF

0.39
14

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

eess.IV cs.AIcs.LG ·2026-08-11 ·Christos Tsepas, Chang Yan, Maximilian Fuetterer, Sebastian Kozerke, Cian M Scannell
publishedcode/data
Abstract · Accepted at the STACOM workshop at MICCAI, Strasbourg 2026

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.

0.38
15

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38
16

Test-Time Instance Selection for Improved Whole Slide Image Analysis

eess.IV cs.CVq-bio.QM ·2026-08-14 ·Quoc Anh Nguyen, Sunhong Park, Jin Tae Kwak
publishedcode/data
Abstract · Accepted at The 2nd MICCAI Workshop on Efficient Medical AI (EMA4MICCAI 2026)

Whole Slide Image (WSI) analysis has been widely studied for cancer diagnosis. Conventionally, a gigapixel WSI is divided into small patches and processed by Multiple Instance Learning (MIL) models. However, existing MIL models typically process all patches, many of which contain redundant or non-informative tissue patterns. Although recent approaches have focused on instance selection to identify discriminative patches and reduce redundancy, these selection modules still require additional training. In this work, we propose Test-Time Instance Selection (TTIS), a training-free, plug-and-play framework that selects compact yet representative patches during inference. TTIS further incorporates a multi-view ensemble strategy to integrate distinct facets of tissue morphology, enhancing robustness. Importantly, TTIS can be seamlessly integrated into existing MIL models without retraining or architectural changes, enabling flexible deployment. Extensive evaluations across multiple benchmarks demonstrate that our approach improves or matches baseline MIL performance across a range of classification and subtyping tasks. Our implementation code is available at https://github.com/QuIIL/TTIS

0.38
17

Synthesizing Post-Acetazolamide Cerebral Blood Flow Maps from Baseline MRI in Moyamoya Using 3D Generative AI

eess.IV cs.AIcs.CV ·2026-08-14 ·Julia Huang, Camila Gonzalez, Rydham Goyal, Aja Zou, Sasha Alexander +3 more
top venue
Abstract · 25 pages. Accepted at Machine Learning for Healthcare (MLHC 2026). To appear in Proceedings of Machine Learning Research (PMLR), volume 340

For patients with Moyamoya disease, impaired cerebrovascular reserve (CVR) is an important hemodynamic criterion for recommending extracranial-to-intracranial bypass surgery. Standard CVR assessment in this cohort uses paired arterial spin labeling (ASL) perfusion MRI acquired before and after acetazolamide (ACZ). When ACZ is contraindicated or avoided, the post-ACZ cerebral blood flow (CBF) map needed for hemodynamic assessment is unavailable. We propose CAE3D, a deterministic 3D conditional autoencoder that synthesizes post-ACZ CBF maps directly from pre-ACZ ASL input. We evaluated CAE3D against ten comparators, including deterministic and diffusion-style 3D baselines, a 2D contextual baseline, and frozen-encoder foundation-model adapters. CAE3D achieved the lowest held-out MAE (0.066), with SSIM 0.80 and PSNR 24.0 dB, and near-zero full-brain mean bias. Its MAE advantage was statistically significant over seven of eight trained-from-scratch baselines, excluding the 2D CAE_2D comparator; its SSIM and PSNR advantages were significant over all eight. Regional delta-CBF predictions compressed the dynamic range in high-response territories. These results establish the retrospective feasibility of post-ACZ CBF synthesis in patients who completed the standard two-scan protocol. Extension to ACZ-contraindicated patients, who were not represented in this cohort, requires external and prospective validation.

0.37
18

ParaJSCC: A Parameterized Framework for Reusable Multimodal Joint Source-Channel Coding

eess.SP cs.MMeess.IV ·2026-08-15 ·Kemi Chen, Mingkai Chen, Youjia Chen, Qian Liu, Wei Gao +1 more
top venue
Abstract

Multimodal signals, such as visual, audio, and tactile data, are increasingly maintained as persistent digital assets in immersive communication systems and digital twins. In these settings, the same multimodal content is repeatedly accessed by heterogeneous receivers with varying modality and bandwidth requirements. Existing compression and Joint Source-Channel Coding (JSCC) methods typically follow a per-request encoding paradigm, resulting in redundant computation and low efficiency during repeated access. To address this issue, we propose ParaJSCC, a multimodal JSCC framework designed for reusable representation serving. ParaJSCC converts each multimodal sample offline at the cloud/content server into a compact, quantized parameter package, which is then stored at the edge serving node for low-latency access. During serving, only the subset required by the current request is transmitted over the wireless channel, followed by lightweight decoding at the receiver. The framework employs a progressive shared-private parameterization to support modality-selective transmission and scalable reconstruction under varying bandwidth constraints. Experiments on multimodal datasets show that ParaJSCC significantly reduces online latency (e.g., from 17.18~ms to 4.34~ms for image-only requests and from 43.96~ms to 11.21~ms for full multimodal requests) and transmission rate (by 47.8\%--51.2\% for selective requests), while maintaining strong reconstruction quality under noisy channels.

0.34
19

Hardware-Aware Deployment of Joint SAR Compression and Despeckling on FPGA

eess.IV cs.LG ·2026-08-11 ·Cédric Léonard, Francescopaolo Sica, Martin Schulz
code/data
Abstract · Submitted to IEEE Transactions on Geoscience and Remote Sensing (TGRS). 11 pages, 8 figures, 4 tables

Next-generation Synthetic Aperture Radar (SAR) missions will generate data far faster than they can downlink, making onboard data reduction essential for near-real-time Earth observation. Learned Image Compression (LIC) offers better rate-distortion performance than handcrafted codecs used operationally today, and recent work shows that simultaneously despeckling and compressing SAR imagery enables better representation capacity while unlocking higher compression rates. These methods, however, have yet to be confronted with the strict power, compute, and operational constraints of spaceborne systems. In this work, we bridge this gap by deploying a joint SAR Despeckling and Data Compression (DDC) framework on an embedded ZCU102 FPGA-based platform, introducing model adaptations that respect the accelerator's fixed-point arithmetic and limited set of supported operations. We evaluate four model topologies across precision levels and across CPU, GPU, and FPGA platforms, revealing several findings with direct design implications. We find that replacing conventional GDN activation functions with plain ReLU improves quality on SAR, suggesting that design principles established for compression of natural images do not necessarily transfer to SAR imagery. In addition, we demonstrate that residual blocks offer little representational benefit for ten times the compute, and show that the FPGA is the most energy-efficient of the platforms tested. Together, these results set a functioning edge deployment workflow and an evidence-based starting point for onboard SAR compression. The code is available at https://github.com/CedricLeon/SAR_DDC_FPGA.

0.32
20

Retrieval-Augmented Vision Foundation Models for Robust Leukemia Cell Classification across Multiple Microscopy Datasets

eess.IV cs.CVcs.LG ·2026-08-11 ·Carlos Zamora, Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
published
Abstract · Accepted at SPIE Optics + Photonics 2026 for oral presentation. 23 pages, 12 figures, 9 tables

Leukemia cell image classification is challenged by real-world domain shifts from acquisition, staining, illumination, and site protocols, causing single-dataset models to generalize poorly in real clinical scenarios. This work presents a robust framework for leukemia classification across multiple heterogeneous datasets using a two-stage pipeline with a pretrained vision foundation model. Stage 1 performs binary classification (leukemia vs. non-leukemia) and is trained using 122,167 single-cell images. Stage 2 is conditionally applied to Stage 1 positives to perform subtype classification into Acute Lymphoblastic Leukemia (ALL) and Acute Myeloid Leukemia (AML), trained using 69,400 single-cell images. Labels are harmonized across five heterogeneous datasets to enable cross-dataset training, and performance is evaluated on a held-out dataset protocol to assess domain-shift generalization. Within this pipeline, three encoders are benchmarked (DinoBloom, pretrained on single-cell images; BiomedCLIP, pretrained on biomedical data; and CLIP as a general-purpose model) under linear probing, Low-Rank Adaptation (LoRA), and a Retrieval-Augmented Classification (RAC) module that retrieves the top-k most similar cell images to provide cytomorphological grounding. The objective is to quantify how much domain-specific pretraining contributes to performance under domain shift, and whether cost-effective adaptation and retrieval can be a viable alternative to expensive domain-specialized pretraining. The held-out protocol additionally serves as a diagnostic tool, revealing when classification performance is attributable to dataset-specific artifacts rather than to cytomorphological features.

0.28