CS Paper Radar

Weekly top 100 · eess.IV

2026-W37 Sep 07 – Sep 13, 2026

Ranked from 3,846 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Exponential Pixelating Integral transform with dual fractal features for enhanced chest X-ray abnormality detection

eess.IV cs.CV ·2026-09-10 ·Naveenraj Kamalakannan, Sri Ram Macharla, M Kanimozhi, M S Sudhakar
publishedunusual
Abstract · Preprint of the article published in the ELSEVIER journal Computers in Biology and Medicine (CIBM), Vol. 182, November 2024. Final version a…

The heightened prevalence of respiratory disorders, particularly exacerbated by a significant upswing in fatalities due to the novel coronavirus, underscores the critical need for early detection and timely intervention. This imperative is paramount, possessing the potential to profoundly impact and safeguard numerous lives. Medically, chest radiography stands out as an essential and economically viable medical imaging approach for diagnosing and assessing the severity of diverse Respiratory Disorders. However, their detection in Chest X-Rays is a cumbersome task even for well-trained radiologists owing to low contrast issues, overlapping of the tissue structures, subjective variability, and the presence of noise. To address these issues, a novel analytical model termed Exponential Pixelating Integral is introduced for the automatic detection of infections in Chest X-Rays in this work. Initially, the presented Exponential Pixelating Integral enhances the pixel intensities to overcome the low-contrast issues that are then polar-transformed followed by their representation using the locally invariant Mandelbrot and Julia fractal geometries for effective distinction of structural features. The collated features labeled Exponential Pixelating Integral with dually characterized fractal features are then classified by the non-parametric multivariate adaptive regression splines to establish an ensemble model between each pair of classes for effective diagnosis of diverse diseases. Rigorous analysis of the proposed classification framework on large medical benchmarked datasets showcases its superiority over its peers by registering a higher classification accuracy and F1 scores ranging from 98.46 to 99.45% and 96.53-98.10% respectively, making it a precise and interpretable automated system for diagnosing respiratory disorders.

0.75
2

Prototyping QoE-Aware Rate Adaptation in Cellular Networks with Commercial Applications

cs.NI cs.MMeess.IV ·2026-09-08 ·Szilveszter Nádas, Lars Ernström, Dan Druta, Igor Pruzhansky, David Lindero +2 more
Abstract · Accepted author manuscript. Published in Proc. IEEE QoMEX 2026, Cardiff, UK. (c) 2026 IEEE. 7 pages, 2 figures, 3 algorithms, 2 tables

Prior work has shown that QoE-aware resource sharing for real-time interactive video can support up to three times more simultaneous sessions at acceptable quality compared to rate-fair allocation. However, the required capabilities (QoE-targeted encoding, runtime spatial complexity estimation, and rich application-network APIs) are not yet available in commercial deployments. In this paper, we take an evolutionary approach: we design a system that delivers QoE-aware resource allocation using only capabilities that can be assembled in a lab today. We extend the utility-based allocation framework to the radio resource domain by introducing composite spatial complexity, which combines a session's video spatial complexity with its time-variant spectral efficiency into a single resource demand function. To operate with commercial real-time video streaming applications that use rate-based congestion control and lack capability to measure QoE, we use external tooling for QoE measurements. We develop an incremental reallocation algorithm with per-interval limits that encode both the congestion control algorithm's speed constraint and that spatial complexity estimates are reliable only near the current rate. The resulting prototype combines external QoE measurements with congestion-signal-based rate steering and does not require modification to commercial applications. We chart an evolution path from this prototype toward full QoE-aware resource sharing, mapping emerging standards (IETF SCONE, CAMARA, Media over QUIC) to the progressive capabilities they enable.

0.64
3

LM-PCVMNet: Pediatric Cervical Vertebral Maturation Analysis with Deep Fusion of Landmarks and Metadata

eess.IV cs.CV ·2026-09-11 ·Peng Wang, Wanzhen Song, Anli Wang, Xueshuo Xie, Xiaohang Guan +1 more
publishedcode/data
Abstract · 12 pages accepted by Information Fusion

Cervical vertebral maturation (CVM) assessment plays a pivotal role in orthodontic diagnosis and determining the optimal timing of treatment, especially for pediatric patients. In this paper, we propose LM-PCVMNet, a novel deep learning framework for automatic pediatric CVM staging. Specifically, our method integrates vertebral anatomical landmark information, heatmap-guided feature modulation, and metadata-informed similarity modeling into a unified learning framework. We introduce a heatmap-guided feature modulation module that enhances feature extraction by leveraging landmark-centered heatmaps to highlight morphologically relevant vertebral regions. A vertebral landmark-prompting block is designed to incorporate anatomical geometry into the representation learning process. Furthermore, we develop a learnable metadata supervised contrastive loss that adaptively modulates positive-pair similarity based on metadata similarity, enabling the model to learn more biologically consistent and discriminative features. To facilitate further research in pediatric orthodontic treatment, we additionally release PCVM+. It contains 1800 lateral cephalometric radiographs from real-world patients aged 3-15 years, with expert-annotated CVM stages, 13 vertebral anatomical landmarks, and corresponding metadata. We perform comprehensive experiments on two datasets, and the results show that our method achieves state-of-the-art performance, effectively improving landmark localization and classification accuracy over existing models. Code and dataset will be available at github.com/ybupengwang/LM-PCVMNet.

0.63
4

Tile-Based Phase Unwrapping with Reliability-Ordered Joining and Residual-Weighted Multipath Averaging

eess.IV cs.CV ·2026-09-11 ·Antoine Moevus, Max Mignotte
unusual
Abstract · 15 pages, 10 figures, 2 tables. Preprint

Phase unwrapping recovers a continuous phase map from measurements known only modulo 2π, in the presence of noise and discontinuities. We propose a tile-based method that combines local spectral reconstruction, reliability-ordered tile joining, and residual-weighted multipath averaging. Each tile is reconstructed by a discrete cosine transform (DCT) least-squares solve, and robust measurements along tile borders guide their joining along a spanning tree. We repeat this reconstruction on shifted tile grids and on rotated and reflected copies of the image, which changes tile borders and joining paths. A residual-weighted average combines the resulting reconstructions, which are computed in parallel and averaged on the fly without being stored. We also introduce the corrected circular rewrapping error, a congruence measure: after removing a global phase offset, it measures how far the rewrapped reconstruction is from the observed phase. It applies to least-squares and path-based methods, even without an unwrapped reference. Used with reference-based errors, it separates agreement with the measurement from recovery of the correct number of cycles. Experiments on radar-interferometric, magnetic-resonance, holographic, and constructed phase images compare our method with seven reference algorithms. Among the methods that complete every test image, ours has the lowest mean fraction of pixels with an error above π. On the images all methods complete, it lies on several speed-accuracy Pareto fronts. Error maps also reveal isolated cycle errors that average scores or congruence alone can hide.

0.58
5

Complementary rPPG-Derived and Lip-Region Frequency Cues for Talking-Face Deepfake Detection

cs.CV cs.AIcs.CReess.IV ·2026-09-13 ·Othmane Harraq, Tamer Aldwairi
hot direction
Abstract

Talking-face (TF) deepfakes are detected unevenly by rPPG-based methods across generators. We study two lightweight visual-only cues, rPPG-derived waveforms extracted by RhythmFormer and lip-region discrete cosine transform (DCT) coefficients, on the seven TF methods of Celeb-DF++ under a subject-independent protocol. In-domain, lip-region DCT matches or exceeds the rPPG-derived 1D ResNet on every method except SadTalker, and Concat fusion reaches AUC 0.891 against 0.824 and 0.827 for the unimodal baselines. Under leave-one-generator-out evaluation the cues split: each transfers clearly better to three held-out methods, and IP-LAP is near chance for both. Concat averages 0.798 but falls below rPPG alone where DCT transfers poorly, so static fusion only partly exploits this complementarity. Lip-region DCT outperforms full-face DCT on six of seven methods. We treat the rPPG-derived signal as an empirical cue and do not claim it is cardiac in origin.

0.55
6

Automated Mobile Video Objective Testing System

cs.NI cs.MMeess.IV ·2026-09-09 ·Eric Petajan, Jonathan Lynam, Morey Antebi, Hessam Moeini, David Lindero +3 more
highly cited
Abstract · 4 pages, 3 figures. Accepted author manuscript of a paper published in the 2025 17th International Conference on Quality of Multimedia Exper…

Applying QoE analysis to optimize usage of cellular spectrum is of high interest to mobile network operators. A key challenge is to be able to perform QoE measurement across very different types of apps, from DASH VoD to interactive applications such as Video Conferencing and Cloud Gaming. This paper presents AMVOTS, a QoE measurement system developed by AT&T, which is flexible enough to support a large range of application types and network conditions. We also discuss using AMVOTS as part of a closed loop to prototype QoE-aware radio resource allocation.

0.54
7

Cost-Aware Vision--Language Model Arbitration for Fabric Structure Recognition A Deployable Multi-Agent System

eess.IV ·2026-09-09 ·Chenwei Wang, Haochen Li, Shuk Ching Tang, Misbah Iqbal, Carman Lee +1 more
benchmark
Abstract

Recognizing a fabric's structure is a prerequisite for translating textile-specific material information into structured digital form for downstream supply-chain systems. Pure CNN classifiers are cost-efficient but fail on visually ambiguous categories; vision--language models (VLMs) generalize more broadly but cost much more per image and are unstable on specialist domains. We present a multi-agent system in which a CNN cascade handles the easy majority and a VLM is invoked only as a selective arbiter, constrained to a top-3 taxonomy-consistent choice. The fabric taxonomy performs as a constraint for the whole recognition process to increase the accuracy and reduce the VLM calls. Meanwhile, the CNN cascade is distilled to a small parameter size to reduce the inference time and meet the needs of practical deployment. On a newly curated 14-class benchmark, a flat ConvNeXt-Tiny baseline reaches $90.45\,\%$ top-1 and $76.9\,\%$ on the four hardest classes; \method's hierarchical cascade reaches $93.94\,\%$ top-1 and $94.50\,\%$ hard ($+17.6$\,pp). Tightening the VLM trigger from $60\,\%$ to $<\!10\,\%$ cuts API cost by ${\sim}90\,\%$ with no measurable accuracy loss. CPU inference is $\le\!93$\,ms without a VLM call ($9.3$\,ms distilled). Each prediction carries a machine-readable reasoning record, offered as an entry point for future supply-chain documentation.

0.52
8

GC360IQ: Generic-to-Individualized Quality Assessment for Stitched 360-Degree Panoramas

eess.IV ·2026-09-08 ·Jinghan Zhou, Zhou Wang
Abstract · 12 pages, 11 figures. Submitted to IEEE Transactions on Image Processing

Existing image quality assessment (IQA) methods typically predict mean opinion scores (MOSs) but struggle to capture variations in individual subject behaviors. This limitation is highly pronounced in immersive visual applications such as stitched 360-degree panoramas, where user opinions diverge drastically based on personal sensitivity to blending-induced luminance inconsistency, detail loss, and geometric misalignment. Here we propose GC360IQ, a novel Generic-to-Individualized IQA framework that establishes a learned explicit feature space to characterize individual subject behaviors. First, we construct a specialized 360-degree panorama database focusing on blending-induced luminance and detail degradation while minimizing geometric misalignment, providing multidimensional quality ratings alongside complete individual scores. Second, we develop a generic quality model that utilizes unblended views as a perceptual reference. Dual feature extraction branches capture gradient and structural information specifically around stitching regions to predict baseline quality. Third, we construct a compact preference embedding space that acts as an explicit feature domain to model each subject's deviation from generic quality perceptions. We also introduce a maximum a posteriori (MAP) adaptation mechanism. By leveraging a preference prior learned within our explicit feature space, a new subject's unique behavioral embedding is mapped progressively with an increasing number of anchor ratings. Experiments demonstrate that the generic model provides accurate stitching quality predictions and that subject adaptation further improves individual score predictions. Deeper analysis of the collected ratings and learned embeddings reveals that observer differences contain structured variation related to scoring tendencies and sensitivity to stitching artifacts, rather than merely random rating noise.

0.51
9

Conditioning noise is a free regularizer for LoRA fine-tuning: no pathology encoder required for diffusion-based artifact detection in histopathology

eess.IV cs.CV ·2026-09-11 ·Konstantinos Moutselos, Ilias Maglogiannis
code/data
Abstract · 23 pages, 3 figures. Code and laboratory record: https://github.com/kmouts/condnoise-histoqc (doi:10.5281/zenodo.22702198). Data: doi:10.528…

Diffusion-based artifact detectors score whole-slide image patches by reconstruction error under a model fine-tuned on clean tissue. We show that conditioning this fine-tuning on random Gaussian embeddings -- resampled at every step from approx. 200 KB of precomputed embedding statistics, with no encoder, no cache, and no change to inference -- consistently widens the clean/artifact separation. A four-step ablation chain shows the benefit requires neither content (shuffled real embeddings), provenance (synthetic Gaussians), a tuned intensity (flat across an 8x variance range), nor per-patch identity (fresh per-step noise); a LoRA-dropout control shows the conditioning pathway specifically, not generic weight perturbation, carries the effect. Patch-level gains of +0.25-0.48 Cohen's d replicate across nine trainings; honest leave-one-slide-out evaluation clears a pre-registered bar in 2/2 seeds; and two pre-registered external endpoints on a 281-case set confirm pooled Delta F1 = +0.0073 (95% CI) and +0.0129 (97.5% CI, two-look corrected). We release the full evaluation protocol, including measured seed noise and selection-optimism pricing.

0.50
10

Foundation Models for Generalizable Semantic and Goal-Oriented Communication

cs.LG cs.AIcs.ROeess.IV ·2026-09-07 ·Boliang Liu, Wint Yi Poe, Riccardo Trivisonno, Giuseppe Caire
published
Abstract · 6 pages, IEEE ICC 2026

Semantic and goal-oriented communication is increasingly studied for 6G, but generalization beyond seen data remains a key weakness under tight rate budgets. Many existing systems overfit their training data and degrade sharply at very low bit rates because they attempt to compress the entire signal. We introduce Foundation Model-Guided Semantic and Goal-Oriented Communication (FMSGOC), a framework that uses broad visual-linguistic Foundation Model priors to mitigate overfitting. It further improves rate efficiency by concentrating bits on sparse, goal-aligned anchors and relying on generative foundation-model priors to reconstruct the masked regions. By decoupling what to send from how to reconstruct, a vision-language foundation model selects and transmits a sparse set of semantic anchors, while a pretrained diffusion model, fine-tuned for masked completion, reconstructs the image at the receiver. In our experiments, FMSGOC reaches 0.039 bits per pixel (BPP), maintains high semantic fidelity (cosine similarity 0.87-0.90 on CIFAR-10), remains robust on previously unseen inputs (0.83-0.86 on ImageNet), and shows good perceptual similarity (0.1278/0.1558, CIFAR-10/ImageNet), outperforming strong end-to-end baselines at lower bit rates.

0.49
11

Spheriverse: 3D Scene Understanding from Spherical Observations in the Wild

cs.CV cs.ROeess.IV ·2026-09-08 ·Fei Teng, Sheng Wu, Mengfei Duan, Guoqiang Zhao, Junhui Ma +5 more
benchmark
Abstract · The established benchmark and source code will be available at https://feit-feiteng.github.io/Spheriverse

Spherical observations provide global visual context for 3D scene understanding. However, visual information is encoded in an angular domain, whereas the physical world is represented in Cartesian coordinates. This cross-space representation gap complicates geometric correspondence and semantic evidence aggregation. To delve into this challenge, we introduce Spheriverse, comprising 64,400 temporally aligned spherical image-LiDAR pairs organized into 644 sequences. The dataset spans diverse scenes, illumination, and weather conditions, with fine-grained semantic classes. We further establish benchmarks for semantic occupancy prediction, semantic mapping, and 3D object detection, evaluating 30+ methods through overall and scene-wise comparisons. For dense prediction, we propose SphereOcc, an occupancy framework that couples spherical geometry modeling with semantic evidence retrieval. Cartesian-Spherical Representation Remodeling (CSRR) incorporates spherical range-azimuth geometry into Cartesian voxel features through region-wise modulation. Spherical Evidence Re-querying (SER) then conditions queries on voxel content and range-height-azimuth geometry to adaptively retrieve relevant semantic evidence from source spherical image features. SphereOcc achieves 13.91% mIoU and 24.65% GeoIoU, yielding relative improvements of 13.9% and 9.3% over the respective best-performing methods, TPVFormer and SurroundOcc. It also ranks first in both metrics across all five scene categories, with consistent advantages across the evaluated spatial partitions and reduced fields of view. The established benchmark and source code will be available at https://feit-feiteng.github.io/Spheriverse.

0.48
12

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47
13

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

eess.IV cs.CV ·2026-09-11 ·Benjamin Jin, Maria del C. Valdés Hernández, Richard Bortsov, Joanna M. Wardlaw, Daniel Bos +1 more
publishedcode/data
Abstract · Accepted at the Stroke and neurovascular diseases Workshop on Imaging and Treatment CHallenges @ MICCAI 2026

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

0.45
14

What Input Resolution Is Required for Bird Species Identification, and What Is Its Latency Cost on an Edge Device? A Study of 14 Input Resolutions and Six Architectures with On-Device Measurements

cs.CV cs.LGeess.IV ·2026-09-13 ·Takeshi Nishikawa
unusual
Abstract · 25 pages, 7 figures, 7 tables. On-device measurements on NVIDIA Jetson Orin Nano (JetPack 6.2, TensorRT 10.3). Data and code: https://doi.or…

Bird-strike mitigation at wind farms requires identifying distant birds that span only tens of pixels, so the classifier's input resolution N is a design variable, not a fixed specification. We study it with a factorial design over 14 side lengths N (16 to 224), six architectures, two training and evaluation regimes and 30 random seeds -- 2,520 checkpoints and 5,040 evaluations -- plus latency measured on an NVIDIA Jetson Orin Nano. Four results. (1) The selected N depends on the target: 0.90 is met on validation by ResNet50 at N=112 in an estimated 1.85 ms (0.8980 on test) and 0.95 by DINOv2-L at N=144 in 12.70 ms; changing the model buys more accuracy than raising N (+5.93 versus +2.33 points at N=112). (2) The benefit of lowering N depends on the assumed preprocessing path: N=224 -> 80 saves 13.5% when each individual is decoded from its own file but 46.2% when the detector decodes the 4K frame once; the Pareto set grows from 20 to 23 configurations. (3) Accuracy must be measured on the deployed engine: half precision costs ViT-S/16 alone 4 to 7 points at N>=96 while the CNNs stay within 0.1 points, and with selection held at validation the choice differs at 26 of 176 targets. A broken FP16 engine can run faster than a correct one, undetectable from latency; admitting 14 ViT-S/16 FP32 configurations moves the recommendation over the 0.931-0.938 band and under the 10 ms budget. (4) ViT-L-scale models fit this device, but activations exceed the FP16 range; splitting the graph at transformer-block boundaries confines FP32 to the affected segments, making the deployed DINOv2-L chain 1.85x faster than the single-engine build. We also quantify how the regime-difference sign stabilises with seed count; a sensitivity split removing some forms of group sharing preserves all 14 non-trivial signs at the selection boundary.

0.41
15

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40
16

Recurrent Dynamic Range Extension

eess.IV cs.CVcs.GR ·2026-09-11 ·Sebastian Dille, Keru Fu, S. Mahdi H. Miangoleh, Yağız Aksoy
top venue
Abstract · 10 pages, 8 figures. Accepted to ACM SIGGRAPH Asia 2026

We present an approach to progressively extend the highlights of an image. Instead of reconstructing the full dynamic range of a complex scene directly, we learn a simpler task first: We extend the dynamic range of an input image by a single exposure value. Once this is mastered, we retrieve the full HDR image for the scene by executing our network recurrently, progressively increasing the dynamic range of the input. Our formulation is agnostic to the input dynamic range and targets a bounded output domain. This enables us to use widely available RAW images for the reconstruction task and adapt adversarial losses to construct realistic images. By incorporating Memory Replay for backpropagation, we can train our network recurrently over multiple inference stages and reduce reconstruction errors. As a consequence, our system reconstructs challenging long-tailed HDR scenes robustly and shows powerful recovery of bright light sources and highlights.

0.40
17

Your Model Already Knows Don't Teach It, Learn to Ask It: Soft Prompting for Few-Shot Adaptation of Vision-Language Models

cs.CV cs.AIcs.LGeess.IV+1 ·2026-09-10 ·Gautam Rajendrakumar Gare, Siyi Li, Hewei Wang, Cesar Daniel Hernandez, Wei Zhao +3 more
Abstract

We address few-shot object detection with vision-language models (VLMs) in out-of-domain settings such as aerial, industrial, and medical imagery, using only ten annotated images for supervision. Existing adaptation methods are discrete prompt optimization and LoRA fine-tuning. We revisit a third option: soft prompting, where a small number of continuous prompt tokens are optimized while the pretrained backbone remains frozen. We identify two key design choices. First, placing prompt tokens at the cross-modal boundary between visual and text tokens outperforms other placements (10.0 vs. 8.4 mAP). Second, initializing prompts from the empty space token outperforms semantic and random initialization. With these choices, one to three learned tokens (7,168 parameters on average) match the best LoRA configuration on Roboflow20-VL (14.2 mAP, 10-shot) while training over 20,000x fewer parameters. Soft prompting remains harder to optimize, exhibiting higher variance across random seeds. Unlike LoRA, however, it causes no forgetting: the LoRA rank matching our accuracy reduces NaturalBench VQA accuracy by 35% relative, rising to 56% at the largest rank, whereas soft prompting leaves pretrained performance unchanged. The learned tokens behave like prompts rather than weights. They transfer to a newer model without retraining (+0.8 mAP on Qwen3.5-9B) and can be verbalized into readable prompts competitive with prompt-search methods (matching DetPO and outperforming GEPA). The approach also extends beyond detection. On RoboCasa manipulation tasks, the frozen $π_{0.5}$ vision-language-action policy benefits from soft prompting, matching the LoRA baseline on two of three tasks when tokens are placed at the gradient bottleneck. These results suggest modern VLMs already encode much of what is needed for specialized domains; the challenge is learning how to ask.

0.39
18

Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification

eess.IV q-bio.QM ·2026-09-08 ·Binbin Yang, Yongmei Jian, Chenglei Liu, Rui Huang, Hongda Shao +8 more
Abstract · 57 pages, including supporting information and a graphical abstract; 5 main figures, 7 supplementary figures, 3 main tables, and 6 supplemen…

Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, three-dimensional ray-tracing thickness (3D-RT), and ray-based defect area (3D-RBA), defined by a 1.5-mm thickness threshold, were calculated. Agreement was assessed using segmentation metrics, intraclass correlation coefficients (ICCs), repeated-measures Bland-Altman analysis, and minimal detectable change at 95% confidence (MDC95). The 3D-RBA framework was evaluated in 120 digital-phantom experiments from 40 participants. Longitudinal analyses included 374 participants, alternative-method comparisons included 65, and retrospective phase II analysis included 24 participants with four visits. Results: Overall AI-to-adjudicated-mask Dice was 0.964 +/- 0.029. Interreader ICCs for volume, thickness, and defect area were 0.956, 0.904, and 0.932; corresponding MDC95 values were 1,596.9 mm^3, 0.227 mm, and 147.4 mm^2. Geometric mean absolute percentage error for defect area was 5.62%, with spatial Dice of 0.961. In 374 participants, volume changes correlated positively with thickness changes (rho=0.431) and negatively with defect-area changes (rho=-0.221). Within-participant phase II correlations followed the same directions in both groups. Conclusions: The workflow demonstrated good interreader agreement. Controlled geometric results and longitudinal associations supported the feasibility of threshold-based defect-area estimation. Volume, thickness, and defect area provide complementary measures of cartilage structure.

0.37
19

PiMiX 2.02: Toward AI-Driven Data Fusion in Radiographic Imaging and Tomography

eess.IV physics.data-an ·2026-09-11 ·Zhehui Wang, Shanny Lin, Nicholas Amano, Ramya Gurunathan, Katie Liu +5 more
Abstract · 12 pages, 5 figures

PiMiX (Physics-informed Meta-instrument for eXperiments) was introduced for multi-instrument, multi-experiment, and simulation-experiment data fusion in radiographic imaging and tomography (RadIT). Here we present PiMiX 2.02 as an evolving AI-enhanced cyber-physical meta-instrument integrating imaging sensors, near-sensor computing, data fusion, physics-informed inference, and human-supervised AI workflows across X-ray, neutron, and other modalities. Demonstrated capabilities include multimodal CMOS radiation imaging, simulation-assisted sub-pixel neutron localization, and edge-deployed optical-neural-network (ONN) inference; GPU and ONN implementations achieved greater than 96% precision for neutron-event detection with sub-micron localization. A further advance is human-in-the-loop agentic-AI co-analysis of X-ray and neutron images from inertial-confinement-fusion experiments. Beyond conventional preprocessing, the workflow generates competing feature hypotheses, ranks contours using physics-informed evidence, estimates confidence, and presents alternatives for human review. The same architecture adapts to different physics: X-ray analysis emphasizes dark, nonuniform ring structures using deformable closed paths and multi-scale evidence, whereas neutron analysis targets bright emission envelopes using fractional-emission levels, intensity gradients, and cross-filter persistence. We also highlight automated comparison of an as-designed stereolithography model with an X-ray CT reconstruction of an additively manufactured metal lattice. Together, these examples show progression from AI assistance in specific processing tasks to multi-task, multi-domain scientific co-analysis. PiMiX 2.0 further provides a pathway toward PRISM, a RadIT scientific foundation model, and tighter integration of diagnostics, digital representations, inference, and experimental control.

0.37
20

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

eess.IV cs.AIcs.CV ·2026-09-09 ·Thierry Judge, Nicolas Duchateau, Andreas Østvik, Havard Dalen, Bjørnar Grenne +4 more
Abstract · STACOM 2026, 10 pages

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

0.37
21

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

eess.IV cs.CV ·2026-09-09 ·Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang +2 more
published
Abstract · Accepted by Biocybernetics and Biomedical Engineering

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

0.36
22

Benchmarking Regularization Methods For 3D Radio Tomographic Imaging

eess.IV eess.SP ·2026-09-08 ·Wanqin Ma, Yijun Chen, Alikhan Umirbayev, Jichen Zhang, Ross Murch
Abstract · 5 pages, 2 figures, in the process of ICASSP 2027

Integrated Sensing and Communication (ISAC) is an important technology for 6G, enabling wireless systems to perceive their physical environment. Radio Tomographic Imaging (RTI) is a potential technique for device-free sensing in ISAC, reconstructing object locations and shapes from Received Signal Strength (RSS) measurements. It can complement other techniques, such as radar and LiDAR, by providing a narrowband modality with wavelength resolution. Recently, an extended version of RTI, known as the extended phaseless Rytov approximation (x3DPRA), has been developed to enhance RTI reconstruction quality, estimate material parameters, and extend RTI from two to three dimensions (3D). However, the 3D formulation is even more ill-posed than the 2D form, as the number of measurements is far fewer than the number of unknown voxels. In this work, we systematically evaluate and compare three distinct regularization approaches (Ridge, Total Variation, and Tensor Nuclear) within the x3DPRA framework. We provide a detailed performance analysis by evaluating both reconstruction quality and computational runtime across the three methods. Our findings show that Total Variation regularization provides the best reconstruction quality but not the fastest runtime, providing guidance for developing high-resolution 3D RTI systems for future ISAC applications.

0.35
23

Scale-Aware 3D Deep Learning for Robust Brain Metastasis Detection in Multimodal MRI

eess.IV cs.CVcs.LG ·2026-09-09 ·Sylvain Jaume, Hongming Wang, Simon K. Warfield
top venue
Abstract · 12 pages, 3 figures, 3 tables

Detecting brain metastases in magnetic resonance imaging (MRI) remains challenging because lesions vary widely in size and appearance, with very small metastases occupying only a minute fraction of a three-dimensional input. We investigate whether combining different spatial fields of view (FOVs) improves lesion detection in multimodal MRI and present a scale-aware 3D deep-learning framework. The method uses independently trained $96^3$ and $64^3$ 3D U-Nets whose whole-volume probability maps are combined by weighted late fusion. This design allows us to study the effect of spatial context separately from image resolution and modality choice. On a 97-patient development cohort, cross-FOV fusion improved lesion-level precision and F1 while substantially reducing false positives relative to the individual models. A same-FOV ensemble control showed that these gains were not explained solely by averaging independently trained networks, supporting a contribution from complementary spatial context. An exploratory cross-FOV agreement filter reduced false positives but did not improve overall F1. These results support cross-FOV probability fusion as a simple and computationally practical strategy for improving the precision-false-positive trade-off in 3D brain-metastasis detection.

0.35
24

Spatial Feature-wise Linear Modulation (SpFiLM) for Contrast Agent-Aware Brain Parcellation

eess.IV cs.CVcs.LG ·2026-09-07 ·Pushpendra Singh, Joshua R. Astley, Roman Rodionov, John Duncan, Tom Vercauteren +1 more
published
Abstract · 10 pages, 2 figures. Accepted at MLCN 2026 (MICCAI workshop)

Most automated brain parcellation tools are developed and validated on T1-weighted (T1w) MRI. Yet, some clinical workflows for which parcellation is relevant only use contrast-enhanced T1w (T1ce) MRI, on which T1w-trained models are less accurate. We present a unified network that parcellates both pre- and post-contrast agent T1w MRI reliably, trained on a combination of the two with conditioning that spatially modulates its response differently for each. Feature-wise Linear Modulation (FiLM) is a known approach for input-based modulation in networks. It applies a per-channel scale and shift uniformly across the input. However, the appearance change between pre- and post-contrast varies locally across the brain, making FiLM suboptimal for our use case. In this work, we introduce Spatial FiLM (SpFiLM), a conditioning layer whose modulation varies spatially, assembling a voxel-wise scale and shift from image-derived spatial patterns. Using a cohort of 134 patients with paired T1w and T1ce MRI parcellated into 106 classes, the addition of SpFiLM layers in a UNet increased the mean Dice on the test set of 25 patients from 80.2% to 84.1%, a 4.9% relative improvement. Adding SpFiLM layers led to the best performance on both pre- and post-contrast MRI, even when controlling for network parameter counts.

0.34
25

Cross-modal learning for SAR target recognition using optical vision foundation models

cs.CV cs.LGeess.IV ·2026-09-07 ·Lucas Hirsch, James R. Hopgood, Javid Khan, Yoann Altmann, Mike E. Davies
top venue
Abstract · Accepted for presentation at SPIE Sensors + Imaging 2026

Synthetic Aperture Radar (SAR) is an important modality in a wide range of imaging applications due to its versatile, long range and near all weather operating capabilities. However, Automatic Target Recognition (ATR) remains a challenging problem due to limited labelled data, the strong speckle in SAR images and the significant domain gap between SAR and more abundant optical imagery. In contrast, electro-optical (EO) imagery benefits from massive datasets, clearer visual structure and powerful foundation models. In this work, we investigate how vision foundation models trained on optical data can provide class level supervision for SAR classification. We propose a cross-modal EO to SAR prototype alignment framework in which a frozen EO encoder, based on a DINOv3 vision foundation model, is used to construct class level optical prototypes without requiring strict EO/SAR pairs. A SAR model is then trained to classify SAR images while aligning its embeddings to the corresponding EO class prototype. At inference time, the SAR model operates independently, without access to optical imagery. We evaluate our approach on the UNICORNv2 dataset, an EO and SAR dataset of civilian vehicles with heavily speckled images and severe class imbalance. EO prototype alignment improves SAR classification accuracy over frozen DINOv3, SAR only finetuning and unpaired distribution alignment baselines, and t-SNE visualizations provide qualitative evidence of clearer separation among classes in the trained SAR embedding space. These results suggest that optical vision foundation models, despite being trained on visible spectrum imagery, provide transferable information for SAR image classification, offering a practical method for using large scale pretrained vision foundation models across challenging sensing modalities.

0.34
26

Recovering Biomechanical Signals from Missing Keypoints Using Temporal Interpolation in Monocular Gait Analysis

cs.CV eess.IV ·2026-09-09 ·Shubham Jariwala
Abstract · 5 pages, 1 figure

Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-driven model reduction. While prior work on recovering missing joints focuses on complex learned models, the effectiveness of simple temporal methods remains underexplored. We evaluate knee-angle estimation under a missing-ankle-keypoint condition and test a first-order temporal interpolation scheme as a recovery mechanism. Across 527 frames of monocular walking video (428 with valid baseline detections), removing the ankle keypoint increased mean angular error to 23.4° +/- 46.7° and collapsed signal variance to near zero. Temporal interpolation reduced error to 1.1° +/- 6.7° and restored variance and smoothness to within a few percent of baseline. These results indicate that gait signals possess sufficient temporal redundancy for a simple, computationally trivial interpolation scheme to recover a critical missing joint, without resorting to learned reconstruction models. The findings support low-complexity, real-time-compatible designs for gait analysis in resource-constrained or occlusion-prone monocular settings.

0.30
27

Computer vision enabled oxygen sensing

eess.IV ·2026-09-07 ·Nikolaos Salaris, Evangelos Mazomenos, Adrien Desjardins, Manish K. Tiwari
unusual
Abstract

Luminescence-based chemical sensors are almost universally read as point detectors with the signal inverted through a single calibration model. Here we reframe optical oxygen sensing as a computer vision problem, in which the sensing film acts as a spatially heterogeneous encoder and a pretrained Temporal Vision Transformer (TViT) as its decoder. The heterogeneity in film thickness, diffusion path length and illumination translate to pixels that provide complementary information on the underlying diffusion dynamics. We achieved up to 54% lower mean absolute error (MAE) by increasing the internal diversity in performance of a pixel group; a gain that linear models cannot reproduce. Using a low-cost platform comprising a Raspberry Pi camera, a UV LED and a porous PtOEP/polystyrene film in tandem with a TViT architecture yielded an MAE of ~6.7 μmol/L, a 96% reduction from the two-site Stern-Volmer (SV) model. We showed that this framework can computationally mitigate the fundamental trade-off between mechanical robustness and temporal response in diffusion limited oxygen sensing by reducing T90 response times by 91%, while exhibiting physically plausible dynamics under a Rauch-Tung-Striebel smoother (2.3% flag rate). The framework was applied across setups, environments and biofilm states, establishing an IoT-compatible paradigm for computationally compensated diffusion-limited chemical sensing.

0.30
28

Physics-Informed Sequential Reconstruction of Scanning Probe Microscopy Images with Calibrated Uncertainty

eess.IV ·2026-09-09 ·Surya Prakash Reddy, Sergei V. Kalinin
Abstract

Scanning probe microscopy (SPM) has become a mainstay of materials science, condensed matter physics, nanotechnology, biology, and semiconductor metrology. An SPM image, however, is acquired sequentially as the probe traverses the surface under closed-loop feedback while thermal drift, feedback dynamics, tip state, mechanical disturbances, and electronic noise evolve during the experiment. Image correction has therefore become an intrinsic part of SPM data analysis. Classical approaches rely on line leveling, filtering, registration, interpolation, and explicit models of tip or scanner distortions, whereas recent work increasingly uses neural networks trained to map corrupted images to corrected ones. Here, we explore a different formulation in which SPM reconstruction is treated as a Bayesian sequential state-estimation problem. The hidden state represents surface height and its low-order evolution along the slow-scan direction; an artifact-dependent quality score continuously modifies the observation likelihood; a forward Kalman pass provides the causal estimate and innovation diagnostics; and a Rauch-Tung-Striebel (RTS) backward pass incorporates information from the complete acquisition. The result is a reconstructed surface, a relative posterior uncertainty map, and line-resolved diagnostic signals. The recursion is computationally lightweight and scales linearly with the number of image pixels, while the physical parameters can in principle be initialized from instrument characterization or from priors learned during previous operation, an extension not exercised here. We organize the method as a multi-axis family of models so that the contributions of state representation, artifact recognition, lateral coupling, and acquisition redundancy can be evaluated independently.

0.29
29

A Generative AI Integrated Multimodal Framework for Low-Latency Multi-Camera Person Re-Identification

cs.CV cs.AIeess.IV ·2026-09-13 ·Leon Fernando, C Dombawala, P. Hettigoda, Vanodhya G. Warnasooriya, Ishara Neranjana +1 more
top venue
Abstract · Presented at 2026 IEEE International Conference on Responsible Artificial Intelligence (IRAI)

Person re-identification (ReID) is essential for multi-camera surveillance and tracking, yet remains difficult due to viewpoint and illumination changes, occlusion, background clutter, and low resolution imagery. We propose a generative AI integrated multimodal ReID framework designed explicitly for robustness under missing cues and low latency deployment. The key idea is a cost aware early-exit cascade that prioritizes inexpensive, high confidence evidence and only triggers expensive modalities for ambiguous cases. Our system integrates (i) global visual embeddings from segmented person regions, (ii) automatically generated fine grained semantic attribute descriptions generated by vision-language models (VLMs), and (iii) optional facial embeddings when face observations are reliable. To optimize the balance between accuracy and latency, we use a cost aware early-exit cascade instead of fusing all modalities. Specifically, we first inspect the top-k retrieval results to determine whether the query is unambiguous. If the best match is clearly separated from the remaining candidates, we stop early and return the result to minimize latency; in ambiguous cases, we keep multiple hypotheses and invoke additional modalities (face/semantic) with adaptive reliability weighting to refine the decision. We report person re-identification performance using mAP and Rank-1 accuracy on the Market-1501 and DukeMTMC-reID benchmarks. The proposed adaptive early-exit cascade resolves 60.7% of DukeMTMC-reID queries and 68.4% of Market-1501 queries without invoking semantic reasoning, reducing computational overhead while maintaining competitive retrieval performance.

0.29
30

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

eess.IV cs.CVcs.LG ·2026-09-11 ·Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu +1 more
Abstract

Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul

0.28
31

SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT Reconstruction

eess.IV cs.CV ·2026-09-12 ·Song Ni, Haijun Yu, Haodong Li, Changsheng Fang, Shuyi Fan +2 more
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but remains severely ill-posed because incomplete projections poorly constrain null-space information. Existing learning-based methods often estimate this information in high-dimensional image space, conflate physical measurement errors with prediction errors, and depend on fixed discretizations. We propose SONAR, a Structure-Consistent Neural Operator for Null-Space-Aware Reconstruction. Instead of recovering the full null-space component, SONAR predicts a low-dimensional null-space-aware representation from the acquired projections as pseudo-measurements. It separates measurement and pseudo-measurement residuals, lifts them into the image domain through physics operators, and applies independent neural operators to constrain their structural effects, thereby accommodating admissible errors while suppressing unsupported structures. To support cross-discretization reconstruction, an anisotropic U-shaped neural operator models the periodic angular and nonperiodic detector dimensions using direction-dependent continuous supports, while image-domain neural operators re-discretize continuous kernels on target grids. These components form an optimization-inspired unrolled network. Experiments on simulated AAPM and clinical MARS photon-counting CT data demonstrate consistent improvements across seen and unseen view settings and unseen image resolutions. On AAPM dataset, SONAR improves PSNR by 1.87~dB at 62 views and by 7.63~dB under zero-shot transfer to a $512\times512$ grid over the strongest competing methods. SONAR also achieves the best overall performance in all clinical settings evaluated, demonstrating accurate, structurally reliable, and discretization-robust sparse-view CT reconstruction.

0.26
32

The MODA General Attribute Suite: A Four-Track Evaluation Benchmark for Fashion Attribute Extraction

cs.CV eess.IV ·2026-09-08 ·Arkid Mitra
benchmark
Abstract · v2: adds Section 6 (crop-track design measurements); corrects one figure in Section 8 affected by an inference preprocessing defect; see Cha…

Fashion attribute extraction is evaluated inconsistently: results are reported as single aggregate numbers across image types that pose different problems, fields that are not visible in an image are scored as ordinary negatives, and the effect of vocabulary mismatch between datasets is acknowledged but not measured. We release the MODA General Attribute Suite, a four-track benchmark that keeps these problems separate by construction. Each track (localized garment crops, catalogue product images, applicability-aware full-body photographs, and product text) carries its own frozen test set, input contract, metric, and leakage unit, and the tracks are never averaged. The protocol requires label-blind prediction, SHA-256 commitment of prediction files before any label is opened, a fail-closed scorer, and a 10,000-sample paired cluster bootstrap at each track's natural leakage unit; promotion requires a positive interval on every track rather than a favourable mean. We release the scorers, the split builders, our own prediction files with their hashes for every image-track system in the main results and for runs we lose, and the MODA_NER(V) model checkpoints for three of the four tracks. The text model is not distributed; its benchmark is. We report baseline results, six interventions that did not improve them, and the limitations of the evidence. On the garment-crop track we also measure how far the headline depends on the benchmark's own design: the order of the two strongest systems depends on whether fields are micro- or macro-averaged, two thirds of the cells the protocol judges carry no annotation, and disabling the applicability decision cuts attribute micro-F1 from 0.63 to 0.27, so most of that score rests on absence decisions the source labels cannot adjudicate. This version also corrects one figure in an external comparison that an inference preprocessing defect had affected.

0.26
33

AstraMoE-SR: Trajectory-Guided Diffusion for Blind Satellite Jitter Deblurring and Super-Resolution

eess.IV cs.CVcs.LG ·2026-09-07 ·Yi-Chung Lai, Chin-Tien Wu, Yu-Chih Chen
Abstract · 12 pages, 4 figures

Pushbroom satellite imaging couples limited spatial resolution with platform attitude instability. Platform jitter produces spatially varying motion blur because each scan line is acquired under a different instantaneous attitude, while perspective geometry causes the same perturbation to induce different pixel displacements across the field of view. Existing blind restoration methods that assume a spatially invariant kernel and satellite jitter correction methods that rely on auxiliary observations are therefore not directly applicable. We present AstraMoE-SR, a single-image framework that jointly restores motion blur and spatial resolution without auxiliary measurements. Rather than estimating a blur kernel, we infer how the camera moved by reparameterizing degradation as a local exposure trajectory under pushbroom geometry. A conditional diffusion model estimates the trajectory distribution, mitigating the over-smoothing of high-frequency jitter by deterministic point estimation. The predicted trajectory conditions a pretrained latent diffusion backbone through trajectory-guided geometric alignment and spatially adaptive reconstruction. We further show that the remaining point-wise trajectory error is consistent with intrinsic jitter-phase ambiguity that is not resolved by increasing estimator capacity. On all 1,411 DOTA-v1.0 images degraded using our physically motivated forward model, AstraMoE-SR is the only evaluated method to outperform the no-restoration baseline across every fidelity metric, improving on StableSR by 0.64 dB PSNR, 15.2% LPIPS, and 0.091 DINO feature similarity. Reconstructions conditioned on predicted trajectories differ negligibly from those using ground-truth trajectories, indicating that the estimates retain the degradation information required for effective restoration.

0.25
34

Aligned Radiometric RGB-Thermal Fusion for UAV Facade Anomaly Screening

cs.CV eess.IV ·2026-09-11 ·Yuan Yang, Shulei Li, Haobo Liang
dataset
Abstract · 9 pages, 3 figures. Preprint. Submitted to IEEE Sensors Journal

Unmanned aerial vehicle facade inspection can combine red, green, and blue (RGB) imagery with thermal measurements to screen surface and subsurface anomalies. However, geometric discrepancies between the sensors and thermal image rendering can obscure spatial correspondence and weak temperature contrasts. This article presents a sensor-level pipeline comprising per-sensor correction, RGB-to-thermal registration, common-support cropping, and signed local contrast encoding of 16-bit radiometric measurements. The encoding preserves the distinction between locally hotter and colder regions and supplies the fourth input channel of a compact single-stream detector. We introduce M3T, a dataset of 674 paired RGB and radiometric thermal samples from five facade-inspection projects covering eight component and anomaly categories. The median residual registration error is 3.384 pixels, and a controlled-displacement analysis characterizes how the local contrast response changes under controlled displacement. Project-grouped four-fold evaluation yields mean average precision of 0.168 over intersection-over-union thresholds from 0.5 to 0.95, using 28.50 billion floating-point operations per image. A separate single-split ablation shows improved delamination detection over RGB-only and alternative thermal inputs, although aggregate accuracy does not improve over RGB alone. Evaluation on RGBT-Tiny shows mixed performance with rendered thermal imagery. These results characterize the category-specific benefits and limitations of aligned radiometric contrast for compact facade screening.

0.22
35

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20
36

Storage-Scalable Progressive Semantic Communication via Knowledge-Base Reuse

cs.LG cs.NIeess.IV ·2026-09-09 ·Heng Zhu, Ye Liu, Kun Zhu, Feifei Song
Abstract · Submitted manuscript

Existing knowledge-base-assisted semantic communication schemes commonly adopt either single knowledge-base quantization (SKBQ) or multi-knowledge-base residual quantization (MKBQ). SKBQ incurs limited storage overhead but has restricted quantization capacity, whereas MKBQ supports progressive refinement by assigning an independent knowledge base (KB) to each stage, causing the KB storage to grow linearly with the transmission depth. To address this problem, we propose storage-scalable knowledge-base reuse quantization (SSKBQ), which reuses a compact set of KBs across multiple residual refinement stages and thereby decouples the number of transmission stages from the number of maintained KBs. A stage-aware residual supervision mechanism is further introduced to regularize intermediate quantized representations and encourage progressive refinement. Experimental results demonstrate that KB reuse provides an effective solution to the storage scalability problem while maintaining competitive progressive reconstruction performance.

0.18
37

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18
38

CHIMERA Challenge Task 2 and 3: Response Subtypes Classification and Progression Survival Prediction in Bladder Cancer Patients using Multimodal Datasets

eess.IV ·2026-09-08 ·Catherine Chia
benchmark
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

High-risk non-muscle-invasive bladder cancer (HR-NMIBC) carries substantial risks of recurrence and progression, while current clinical risk stratification remains limited. CHIMERA was established as a multimodal AI challenge to benchmark prediction in HR-NMIBC under standardized evaluation. Task BRS predicts RNA-seq-defined BCG Response Subtypes from histopathology and structured clinicopathological data, whereas Task Progression models time-to-progression using histopathology, structured data, and RNA sequencing. A multimodal dataset of 368 patients was divided into public training and hidden validation and test sets. In total, 159 submissions were made, and 13 top-performing models were selected for benchmarking. The best models achieved a weighted F1 score of 0.73 for Task BRS and a C-index of 0.68 for Task Progression. Post-challenge analyses revealed task-dependent modality contributions, cohort-dependent performance degradation, and sensitivity to missing structured data. In Task BRS, histopathology partly compensated for pathology-derived structured variables, whereas progression models showed greater dependence on complementary inputs. Cross-model error analysis further identified patients that were consistently difficult across different architectures, with T1 substage associated with prediction difficulty. These findings highlight barriers to transportability and the importance of missingness-aware modeling and independent multi-institutional validation. CHIMERA provides a standardized multimodal benchmark for bladder cancer and a framework for studying not only model performance, but also robustness, information sufficiency, and patient-level prediction failure.

0.13
39

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13
40

Leveraging Cardiac Imaging to Improve ECG-Based Detection of Chagas Disease in Resource-Constrained Settings

cs.LG cs.AIeess.IV ·2026-09-08 ·Laura Alvarez-Florez, Daniel Uyterlinde, Samuel Ruipérez-Campillo, Lukas P. A. Arts, Folkert W. Asselbergs +1 more
Abstract

Chagas disease is a major cause of cardiomyopathy in Latin America. Cardiac magnetic resonance (CMR) imaging can characterize its structural abnormalities, but scanners and expert readers remain scarce in endemic regions. Electrocardiography (ECG) is inexpensive and widely available, yet structural disease must be inferred indirectly from electrical signals. We propose to transfer CMR-derived structural knowledge to ECG through contrastive pre-training. Using 63,193 paired ECG-CMR examinations from the UK Biobank, we align an ECG encoder with a clinically grounded CMR embedding space using an asymmetric InfoNCE objective. Despite seeing no Chagas cases during pre-training, the resulting representation improves ECG-based Chagas detection. Across CODE-15% and SaMi-Trop, a frozen linear probe achieves an AUROC of 0.851 and sensitivity at the top 5% of predicted risk (Top5%-TPR) of 0.427 in five-fold cross-validation, compared with 0.827 and 0.377 for an unaligned ECG-FM baseline. On the PhysioNet/CinC 2025 Challenge test set, our model obtains the highest AUROC on SaMi-Trop-3 and the best ELSA-Brasil challenge score among the three top-performing methods, indicating that imaging-supervised ECG representations can generalize to populations and settings beyond the pre-training distribution.

0.12
41

Deformable 2D Gaussian Splatting for Efficient 4K Video Compression

eess.IV cs.CV ·2026-09-12 ·Chenhao Zhang, Fengqing Zhu
Abstract

Ultra-High-Definition (UHD) video presents significant challenges for efficient storage and real-time decoding. Learning-based methods, such as Neural Video Compression (NVC) and Implicit Neural Representations (INR), achieve competitive rate-distortion performance but suffer from high decoding latency and excessive memory usage. Meanwhile, Gaussian Splatting has recently attracted attention in the computer graphics community due to its ultra-fast rendering and high-fidelity visual quality. Despite these advantages, its application in video compression remains largely unexplored. To bridge this gap, we propose a real-time video compression framework that represents and compresses a Group of Pictures (GOP) using a coarse-to-fine multi-scale 2D Gaussian Splatting (2DGS) structure coupled with a lightweight deformation network. Experiments demonstrate that our method delivers rate-distortion performance in LPIPS that surpasses H.265 and other state-of-the-art learning-based video compression methods. Our work demonstrates the potential of Gaussian Splatting as a practical solution for efficient high-resolution video compression.

0.09