CS Paper Radar

Weekly top 100 · eess.IV

2026-W34 Aug 17 – Aug 23, 2026

Ranked from 3,407 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

MDFI: A Multi-Domain Features Integration for Compressed Video Quality Enhancement

eess.IV cs.CV ·2026-08-21 ·Sang NguyenQuang, Hieu Bui Minh, Dang BuiDinh, Xiem HoangVan
top venuedatasetcode/data
Abstract

The latest video coding standard, H.266/VVC, has demonstrated significant improvements in compression efficiency compared to H.265/HEVC. Despite its advanced coding techniques, H.266/VVC still faces challenges in meeting the increasing demand for higher perceptual quality and enhanced compression performance. To address these limitations, we propose MDFI (Multi-Domain Features Integration), a compressed video quality enhancement approach that features a novel Frame-Prediction Feature Transform (FPFT) module to process prediction information. Moreover, MDFI integrates a multi-domain feature fusion strategy that effectively combines spatiotemporal characteristics, cross-frequency representations, and compressed-domain prediction information to enhance decoded video quality. Additionally, we introduce a comprehensive dataset that encompasses uncompressed video sequences, corresponding reconstructed versions at multiple QP levels, and predicted frames generated from H.266/VVC compressed bitstreams, providing essential resources for developing and benchmarking video enhancement approaches. Extensive experiments demonstrate that our MDFI approach achieves superior performance to state-of-the-art methods in both objective metrics and visual quality, effectively mitigating video compression artifacts. The code is available at: https://github.com/dangdinh17/MDFI.git.

0.75
2

Flow Matching-Based PET Image Reconstruction

eess.IV cs.CVphysics.med-ph ·2026-08-20 ·Fumio Hashimoto, Ziqian Huang, Tatsuya Yokota, Kuang Gong
Abstract · 10 pages, 8 figures

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

0.57
3

Multispectral Household Plastic Classification for Recycling Using a Camera Array

eess.IV ·2026-08-23 ·Katja Kossira, Jürgen Seiler, André Kaup
publishedcode/data
Abstract

Plastic pollution has become a persistent problem in natural ecosystems. Driven by insufficient waste management, limited recycling efficiency, and high costs for recycling, plastic waste in the environment poses significant ecological and health risks. Recycling requires accurate identification of polymer types, but existing optical sorting systems often struggle to distinguish common household plastics. In this work, we present a novel classification approach based on a multispectral imaging system consisting of nine cameras equipped with near-infrared bandpass filters. The system is designed to discriminate the seven most common household plastics. From the resulting multispectral images, we extract the spectral fingerprints and derive features such as intensity differences between specific wavelength pairs and their slopes, as well as false-color image representations. A dedicated preprocessing pipeline aligns and normalizes the data before classification. We recorded a multispectral household plastic database (https://github.com/FAU-LMS/MHPM) and trained four different classifiers Gradient Boosting, Extreme Gradient Boosting, Light Gradient Boosting Machine, and CatBoost. The best-performing model achieves a classification accuracy of 86.7%. The computational runtime is 2.603 μs per pixel, enabling efficient processing of high-resolution images. The entire setup is built from off-the-shelf hardware components, which makes replication straightforward and allows direct integration into industrial sorting pipelines.

0.56
4

Frozen CLIP Priors for Robust Self-Supervised Poisson Inverse Problems

eess.IV cs.CV ·2026-08-20 ·Laura C. Diaz-Delgado, Emmanuel Martinez, Henry Arguello
top venue
Abstract

Self-supervised learning for imaging inverse problems is increasingly important in photon-limited settings, where acquiring clean ground truth is impractical and reconstruction must remain stable under dataset and acquisition shifts. This challenge is amplified under Poisson noise, whose signal-dependent statistics interact with sampling operators (e.g., CFA mosaicing). Meanwhile, foundation vision encoders trained at web scale offer distortion-invariant, content-related representations that generalize well across domains, suggesting a promising route to build priors that transfer beyond the training distribution without expensive fine-tuning. This paper proposes an ADMM-inspired unrolled plug-and-play solver for Poisson inverse problems that decouples a closed-form data-consistency update from a parameter-efficient prior. The prior is implemented as a lightweight decoder operating on frozen CLIP RN50 dense multi-scale features, adapting foundation representations with less trainable parameters. For self-supervision, the method integrates GR2R measurement-domain re-corruption with an Equivariant Imaging regularizer via virtual acquisitions. Experiments on Poisson CFA demosaicing and deblurring show competitive quality, improved robustness under shifts, and self-supervised performance approaching supervised training.

0.54
5

Primitive Representation Learning for Unsupervised Dynamic Contrast Enhanced MRI Reconstruction

eess.IV cs.CVcs.LGeess.SP+1 ·2026-08-18 ·Veronika Spieker, Wenqi Huang, Cemre Ariyurek, Liam Timms, Daniel Rueckert +3 more
publishedcode/data
Abstract · Accepted at MICCAI Off-Grid Workshop 2026

Reliable quantitative analysis of dynamic contrast-enhanced MRI requires high-quality spatiotemporal reconstructions at high undersampling rates. Scan-specific reconstructions using Gaussian and Gabor primitives have shown promising results without the need for large training datasets, but have not addressed the additional dimension of dynamic contrast. We propose a multi-dimensional, primitive based framework for dynamic contrast-enhanced MRI reconstruction that disentangles the underlying anatomy, the dynamic contrast enhancement, and residual motion into separate temporal basis functions, thereby enabling a geometrical interpretation of the representation. We show that this architecture achieves performance competitive with conventional reconstruction methods, both in reconstruction quality and in the accuracy of extracted aorta and kidney enhancement curves. The modular tier design extends naturally to additional dynamic factors and higher acceleration rates. Code available at https://github.com/compai-lab/2026-GaborDCE-spieker.

0.51
6

BiCRVC: An Efficient Bidirectional Neural Video Compression Framework via Coupled Representation Coding

eess.IV ·2026-08-17 ·Wei Jiang, Junru Li, Kai Zhang, Li Zhang
Abstract · Fix some typos

Neural video compression (NVC) has achieved strong compression performance, but practical random-access coding still faces two technical challenges: existing bidirectional NVCs (BVCs) usually require costly motion-first decoding, and reliable motion estimation is difficult under long-range bidirectional prediction. To address these issues, we present BiCRVC, an efficient bidirectional neural video compression framework based on coupled representation coding. Instead of coding motion and frame information with two separate codecs, BiCRVC transforms the motion representation and the current-frame latent into a unified latent representation for entropy coding. This design enables motion and frame information to be decoded from the same bitstream with one unified codec, while still reconstructing motion-aligned contexts for frame decoding. To improve motion accuracy, we introduce multi-candidate motion estimation (MCME), which combines multi-scale motion estimation and parallel accumulated motion estimation to better handle diverse and long-range motions. To reduce motion coding overhead, we further propose bidirectional motion feature propagation (BMFP), which reuses previously decoded motion features at both the encoder and decoder as temporal priors for conditional motion coding. In addition, coupled distortion training and random GOP structure training are used to encourage joint motion-frame coding and improve adaptation to hierarchical random-access structures. Experiments show that BiCRVC achieves better compression performance than state-of-the-art BVCs while providing about 30 times faster 1080p decoding than recent BVCs.

0.49
7

Clinical Pathways Matter for Multimodal Deep Learning in Early Alzheimers Disease Detection

eess.IV ·2026-08-17 ·Yao Lu, Solveig Kristina Hammonds, Alvaro Fernandez-Quilez
published
Abstract · Published

Identifying individuals at risk of Alzheimer's disease (AD), particularly in the preclinical and early stages, remains challenging. Although deep learning approaches based on structural MRI show promise as a non-invasive biomarker, existing multimodal models require task-specific training and depend on biomarkers that are not routinely available in clinical practice. Here, we propose a zero-shot multimodal framework based on SigLIP that combines structural MRI embeddings with text embeddings of routinely collected clinical variables for early AD risk stratification in individuals at preclinical or mild cognitive impairment (MCI) stages. We evaluated the approach in 416 individuals from the ADNI cohort (age: 72.73 +- 6.7). SigLIP was used without fine-tuning to extract MRI and clinical text embeddings, which were combined into multimodal representations for individual-level AD risk prediction within 4 years. We further compared the model performance in a single-visit and two-visit settings to assess the value of longitudinal information and framework scalability. In the single-visit setting, combining MRI embeddings with MMSE, age, and sex achieved an AUC of 0.91 +- 0.02, outperforming both a CSF A\b{eta}42-based model (AUC 0.73 +- 0.08) and an MMSE-based model (AUC 0.85 +- 0.22). In the two-visit setting, performance was maintained or improved, supporting the scalability of the approach to longitudinal data. These findings suggest that zero-shot multimodal fusion of structural MRI and routinely collected clinical variables may provide a practical and scalable strategy for early AD risk stratification without task-specific retraining.

0.48
8

CHIMERA Challenge: Biochemical Recurrence Prediction in Prostate Cancer Patients using multimodal datasets

eess.IV cs.CV ·2026-08-21 ·Robert N. Spaans, Catherine Chia, Tongjie Wang, Adam Kowalewski, Parandzem Khachatryan +5 more
benchmark
Abstract · 38 pages, 3 figures, 3 supplementary figures. Preprint submitted to Medical Image Analysis. Challenge results presented at the CHIMERA works…

Biochemical recurrence (BCR), defined as any detectable prostate-specific antigen level after prostatectomy with confirmatory elevation, is widely used as a surrogate endpoint and typically assessed using clinical and pathological variables. Currently, no standardized benchmark exists for multimodal prognostic modeling in urological cancers, partly because curating heterogeneous multimodal data remains challenging. We developed the CHIMERA Challenge, a multimodal benchmark integrating preoperative mpMRI, post-prostatectomy histopathology, patient characteristics, and clinician-derived variables from 267 patients across two institutions. The dataset comprises 801 MRI sequences, 13 clinical variables per case, and 942 WSIs. Training (n=95), validation (n=23), and test (n=149) splits were established and hosted on the Grand Challenge platform. Baseline clinical and pathological characteristics did not differ significantly across splits. Models were evaluated on predicting time to BCR using the C-index. Post-challenge analyses tested how each model type performed when clinician-derived variables were withheld or randomized. Unimodal clinical models achieved the highest test C-index of 0.7402 but proved sensitive to the integrity of these variables, with performance collapsing toward chance (C approximately 0.50) when they were randomized. Multimodal models retained near-baseline performance when these variables were withheld (delta C at most 0.04), indicating their ability to recover prognostic signal directly from imaging data. CHIMERA is the first public, standardized multimodal benchmark for prostate cancer prognosis. Although models using only patient characteristics and clinician-derived variables yielded the highest leaderboard performance, multimodal models demonstrated greater robustness in clinically realistic scenarios where complete expert annotation is not guaranteed.

0.47
9

A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation

eess.IV cs.AIcs.CV ·2026-08-17 ·Siyuan Ma, Liang He, Mengying Zhu, Yi Chai, Mengyao Lyu +12 more
published
Abstract

Missing or degraded sequences can limit prostate multiparametric MRI. We developed MSCNet, a sequence-conditioned cross-modal generative framework for reconstructing unavailable contrasts and restoring degraded acquisitions. Across ten completion tasks, task-specific MSCNet achieved mean structural similarity of 0.818 versus 0.798 for the strongest task-matched comparators; matched-capacity analyses showed larger differences in lesion fidelity and boundary preservation. In a blinded 1,000-case reader study, overall image quality met the prespecified non-inferiority criterion for DWI, ADC and T2W completion, but not T1W. In a separate 200-case diagnostic assessment, AUCs for clinically significant cancer were 0.860 with acquired images, 0.841 with MSCNet and 0.797 with baseline-generated images. A locked 186-case three-hospital cohort supported multicentre transportability. These retrospective results support quality-controlled cross-modal reconstruction as an adjunct to acquired prostate MRI.

0.47
10

SweepLSD: A One-Pass, O(width)-Memory Line Segment Detector with an Integer-Only Streaming Core and a Real-Time FPGA Realization

eess.IV cs.ARcs.CV ·2026-08-22 ·Yoshiyasu Shimizu
code/data
Abstract · 40 pages, 12 figures, 18 tables. Code, benchmarks, and evaluation harnesses (MIT): https://github.com/yosh-shimizu/sweeplsd

We present SweepLSD, a line segment detector that reads the image exactly once and emits each segment within a few rows of its last pixel passing the scan line. Every stage, including connected-component labeling and the final line test, processes the image as a row stream: intermediate memory is O(width) rather than O(pixels), and the per-pixel core is integer-only. We give the first complete description of the algorithm, designed in the author's 2014 master's thesis but never published, together with an open-source C++17 implementation and an FPGA realization -- held bit-exact against the software in its hardware configuration -- detecting segments in live 1080p30 video on 2009-era silicon without frame buffer or external memory. On structure-rich public 4K photographs downscaled to Full-HD, one CPU thread detects segments in ~11 ms -- 4.6x/5.2x/25x faster than the original authors' implementations of ELSED, EDLines, and LSD -- with the tightest frame-time distribution and the best per-segment direction accuracy of the four detectors, and curve rejection by design, while trailing ELSED in F-score on synthetic ground truth. A Manhattan-frame vanishing-point study on York Urban and NYU-VP scores every detector under a selection/evaluation-separated best-estimator-per-detector protocol, under which SweepLSD leads on NYU-VP by ~0.3 degrees and trails by 0.1 degrees on York Urban, with the fastest end-to-end pipeline of the four detectors on both. A single-frame camera-attitude application, evaluated on synthetic scenes with exact ground truth and on EuRoC and TUM-VI, matches the baselines' accuracy at a fraction of their memory, and drives a 4K horizon lock to 0.06 degrees median attitude error at 32 ms median per frame.

0.44
11

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-18 ·Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle, Chetan Shenoy, Mehmet Akçakaya
top venue
Abstract · To appear in IEEE TBME

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

0.43
12

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.42
13

GET: Generative Embedding Translation for Medical Image Segmentation

eess.IV cs.CVcs.LG ·2026-08-23 ·Md Maklachur Rahman, Md Hasan Al Banna, Saraf Anjum, Mahmudul Hasan, Tracy Hammond
publishedcode/data
Abstract · Accepted at ECCV 2026 - BioImage Computing Workshop

Generative segmentation provides an alternative to direct pixel-wise prediction by operating on learned latent representations, but effective image-to-mask translation must preserve target structure while remaining computationally efficient. We propose Generative Embedding Translation (GET), a structured embedding-translation framework that progressively transforms image embeddings into mask embeddings within the frozen latent space of a Stable Diffusion VAE. GET uses a U-Net-style Embedding Translation Network with 1.07M trainable parameters, combining Mobile Bottleneck Convolutions, Subsampled Self-Attention, and Multi-scale Feature Enrichment for local modeling, global context, and multi-scale refinement. Across five medical segmentation datasets, GET outperforms generative, CNN, and Transformer baselines. Compared with the strongest generative baseline, GMS, GET improves average Dice and IoU by 0.93% and 1.26%, reduces HD95 by 0.81 pixels, and uses 31.41% fewer trainable parameters. Under bidirectional BUS-BUSI domain shift, GET further improves Dice and IoU by 3.51% and 3.39%, while reducing HD95 by 27.37 pixels. Our code is available at: https://github.com/maklachur/GET.

0.41
14

Simple, Safe, and Overlooked: Reclaiming Sustainable Domain Generalization with Statistical Color Matching

cs.CV cs.LGeess.IV ·2026-08-19 ·Sebastian Doerrich, Francesco Di Salvo, Shyam Nandan Rai, Marco Lents, Christian Ledig
publishedcode/data
Abstract · Accepted to DEMI @ MICCAI 2026 (4th Workshop in Data Engineering in Medical Imaging)

Hardware shifts, color variations, and changing patient characteristics between development and deployment routinely break trained medical image classifiers. Existing remedies fall short: standard color jittering provides insufficient diversity, while deep generative style transfer algorithms hallucinate features, destroy clinically relevant structures, and waste massive compute resources. To address this, we revisit classical statistical color matching and repurpose it as Colorist, a highly efficient data augmentation strategy that applies global mean-standard deviation matching directly in the RGB color space. We demonstrate that this training-free, fully interpretable approach safely generates structurally intact domain variations, outperforming deep generative models in structural fidelity and color alignment. Across out-of-distribution histopathology, peripheral blood, dermatology, and retinal datasets, it improves balanced accuracy by up to +9% over state-of-the-art domain generalization regularizers and by +13% over an unaugmented baseline. Moreover, by avoiding neural networks in the augmentation loop, Colorist preserves anatomical structure, minimizes carbon footprint, and integrates seamlessly into standard dataloaders. Together, these findings establish statistical matching as a safe, interpretable, yet overlooked alternative to deep architectures for clinical robustness. Source code is available at https://github.com/sdoerrich97/colorist.

0.37
15

Sparse Light Field Sampling Improves Casual 3D and 4D Reconstruction

eess.IV cs.CV ·2026-08-20 ·Shamus Li, Ruiming Cao, Laura Waller, Kristina Monakhova, Sara Fridovich-Keil
datasetcode/datahot direction
Abstract · Project page: https://shamus.li/lightfield-gaussian-splatting

Many consumer smartphones, stereo cameras, and light field cameras record multiple synchronized viewpoints in a single exposure event. However, novel view synthesis pipelines commonly use only a monocular stream and rely on camera motion or learned priors to obtain angular coverage. In this paper, we ask: why do we use only one viewpoint? We analyze sensor-limited multi-view, where one sensor trades off spatial and angular resolution, and exposure-limited multi-view, where multiple sensors on one commodity device observe each event simultaneously. We introduce a new dataset incorporating three types of commodity multi-view cameras, and evaluate sparse-view 3DGS and 4DGS baselines measuring reconstruction quality as a function of number of exposures and angle between extreme views. Our results demonstrate that using multiple cameras, even with a low baseline, significantly improves reconstruction quality in single-shot, few-shot, and casual video settings. In addition, under a fixed sensor budget, angular sampling improves reconstruction when exposures are scarce despite lower spatial resolution. The gains are most pronounced for single-shot and dynamic scenes, where a stationary monocular camera lacks the angular diversity to recover scene geometry and motion.

0.36
16

FlowSem: Flow Matching for Adaptive Wireless Image Transmission in Semantic Communication

eess.IV ·2026-08-21 ·Arnab Emon, Eslam Eldeeb
Abstract

Wireless image transmission becomes challenging under poor channel conditions and stringent bandwidth constraints, as the receiver needs to preserve both pixel-level fidelity and meaningful visual structure. Classical separation-based systems, such as better portable graphics with low-density parity-check coding (BPG+LDPC), may suffer from cliff-effect behavior. While deep joint source-channel coding (DeepJSCC) provides graceful degradation as channel conditions worsen, its reconstructions may lose fine details under strong compression and severe channel distortion. To address this limitation, this paper proposes a two-stage flow matching-based semantic communication framework, termed FlowSem. In the first stage, a signal-to-noise ratio (SNR)-adaptive DeepJSCC model maps the source image into channel symbols and produces a coarse reconstruction at the receiver. In the second stage, a conditional flow matching model generates the final image from Gaussian noise conditioned on the DeepJSCC reconstruction and channel SNR. The proposed framework is evaluated on the Cityscapes dataset under additive white Gaussian noise (AWGN) and Rayleigh fading channels using a fixed channel-symbol budget. The baselines include a rate-matched BPG+LDPC system, DeepJSCC, a denoising diffusion probabilistic model (DDPM), and a denoising diffusion implicit model (DDIM). Results show that FlowSem achieves competitive pixel-level fidelity and improved structural and perceptual reconstruction quality over the considered generative baselines across different channel conditions. FlowSem provides up to 60% lower Fréchet Inception Distance (FID) than the diffusion baselines at low SNRs. Moreover, FlowSem reaches high reconstruction quality using only a few ODE integration steps, providing a favorable quality-latency tradeoff compared with standard DDPM and accelerated DDIM sampling.

0.36
17

MOSAIC: A Self-supervised Dynamic Multi-encoding Reconstruction Framework for 3D Late Gadolinium Enhancement MRI

eess.IV ·2026-08-19 ·Muhammad A. Sultan, Yingmin Liu, Katherine Binzel, Katarzyna E. Gil, Karolina M. Zareba +1 more
Abstract

Purpose: To develop and evaluate a self-supervised dynamic reconstruction framework for highly undersampled dual-echo three-dimensional late gadolinium enhancement (3D LGE) MRI. Methods: MOSAIC jointly models multi-echo image content, coil sensitivity maps, and beat-specific nonrigid motion directly from acquired undersampled data, without requiring fully sampled training datasets or accurate precomputed sensitivity maps. Unlike existing methods that bin the acquired data into different motion states, with or without motion compensation, MOSAIC reconstructs a motion-resolved 3D LGE image from each heartbeat. The method was evaluated using digital phantoms with simulated myocardial scars and in vivo animal and human studies. Results: In phantom experiments, MOSAIC achieved higher peak signal-to-noise ratio and structural similarity index measure than low-rank deep image prior reconstruction and ablation variants of MOSAIC. In animal and human studies, MOSAIC achieved higher blinded expert image-quality scores than inline image-navigated compressed-sensing and low-rank deep image prior reconstructions. Conclusion: MOSAIC demonstrated the feasibility of motion-resolved free-breathing dual-echo 3D LGE MRI at acceleration factors exceeding 1,000, with improved detail preservation and artifact suppression relative to the state-of-the-art comparison methods.

0.36
18

Rapid Debris-Volume Estimation from Post-Hurricane Aerial Imagery

cs.CV eess.IV ·2026-08-17 ·Kooshan Amini, Jamie Ellen Padgett, Guha Balakrishnan
survey
Abstract

Hurricane debris removal is planned, contracted, and federally reimbursed on the basis of volume estimates, yet operational practice still relies on parametric forecasts with 41-90% documented over-estimation or on truck-load tallies that arrive only after hauling begins. We present DebrisHeightNet, a segmentation-conditioned monocular debris-height network that estimates spatially explicit debris volume from a single pass of post-event aerial RGB imagery, the kind of survey routinely flown within days of a hurricane landfall. We train only a lightweight 1.08 M-parameter head on top of two frozen vision foundation models. This head regresses height from a Depth Anything V2 backbone, conditioned on the debris segmentation of CLIPSeg-debris from our prior work. Because no post-hurricane debris-height ground truth exists, we synthesize the training target by confidence-weighted LiDAR-monocular fusion (CW-LMF), designed to suppress non-debris LiDAR returns. This fused target is a constructed supervision signal rather than ground truth, so we corroborate it against external references rather than claiming it as truth. A region-level power-law calibration, driven by each region's low-density debris fraction, converts model volume into an estimate of the reported hauled debris with quantified uncertainty. Across ten regions spanning five hurricanes and three states, the uncalibrated model agrees with an independent uncrewed-aerial-vehicle (UAV) survey of the training region at Spearman $ρ= 0.87$ and lands within 30% of the reported record where the Hazus and FEMA-hybrid parametric forecasts over-predict it by 2.7-4.8$\times$. Deployment requires no LiDAR, no ground access, and no second flight, so the method can produce spatially explicit volume estimates wherever single-pass post-event imagery is flown.

0.35
19

Reliability- and Anatomy-Consistency-Aware Multimodal Learning for Robust Fracture Classification from Bangladeshi Radiographs

eess.IV cs.AIcs.CV ·2026-08-21 ·Musa Tur Farazi, K G Subarno Bithi
hot direction
Abstract

Background: Multimodal fracture classifiers may benefit from patient and anatomical metadata, but they can also become brittle when contextual information is missing or mismatched. Methods: We studied 1493 radiographs from the Bangladeshi OrthoFrac-XR dataset using leakage-safe age, sex, bone type, and laterality. A ConvNeXt image encoder was combined with a clinical multilayer perceptron through concatenation, late fusion, reliability-gated residual fusion, and a hierarchical state-location formulation. We additionally introduced an anatomy-consistency gate that attenuates metadata corrections when an image-side anatomical prediction disagrees with the reported bone type. Results: Across five folds and three seeds, hierarchical residual fusion achieved a macro-F1 of 0.6046 +/- 0.0279, compared with 0.5727 +/- 0.0270 for image-only learning, while improving the Brier score from 0.5239 to 0.4948. In a five-fold robustness experiment, anatomy-consistency fusion reduced the macro-F1 loss under shuffled metadata from 0.0567 to 0.0203 relative to ordinary residual fusion, although its clean-data macro-F1 was lower. Without bone type at inference, auxiliary anatomy supervision improved macro-F1 from 0.5620 +/- 0.0330 to 0.5899 +/- 0.0289. Conclusions: Structured context improves fracture classification, and consistency-aware gating limits harm from mismatched metadata. The observed clean-performance-robustness trade-off and the absence of patient-level identifiers motivate external and prospective validation.

0.34
20

Decoupling Parcellation from Classification: Systematic Benchmark of Fast Brain Segmentation Methods for Alzheimer's Disease Detection

eess.IV cs.AIcs.CV ·2026-08-17 ·Jiadao Zou, Hongyu Guo, Wei Xi
benchmark
Abstract

Brain parcellation and classification are typically evaluated in isolation, yet downstream AD detection performance depends on their interaction. We decouple these components and systematically benchmark fast deep learning parcellation methods (SynthSeg+, OpenMAP-T1) against the FreeSurfer (FS-HV) clinical baseline through down- stream AD classification on OASIS-1. Our factorial design evaluates three parcellation methods, two volumetry strategies (hard vs. soft), and four classifier paradigms (clinical thresholds, supervised feedforward networks, ensemble methods, and foundation models with zero/few-shot prompting), with all results quantified using BCa Bootstrap 95% confidence intervals.

0.33
21

Technically Plausible but Clinically Misleading? Expert Evaluation of Patient-Personalized Synthetic Prostate MRI

eess.IV ·2026-08-17 ·Gabriel Paulo Maglalang Israel, Sol Gedde, Alvaro Fernandez-Quilez
published
Abstract · To appear in SCAI 2026 proceedings

Magnetic resonance imaging (MRI) is central to prostate cancer assessment, yet its acquisition is costly and time-consuming, making it a major bottleneck in the patient care pathway. Personalized MRI synthesis is a promising direction because it may allow the generation of clinically realistic images tailored to individual patients while reducing the dependence on scanner-acquired imaging. In this work, we in-vestigate whether patient-personalized MRI synthesis produces images that experts perceive as clinically plausible and how such personaliza-tion influences expert interpretation. We synthesize patient-personalized prostate MRI using a 3D diffusion model conditioned on routine pre-imaging clinical variables age and PSA. Using a large publicly available dataset, we first verify that synthesized images are technically compara-ble to scanner-acquired MRIs using standard image similarity metrics. We then conduct a pilot, single-blinded, randomized expert study on a subset of cases sampled to reflect variation in patient clinical pro-files. A radiologist compared personalized and unconditioned synthetic MRIs using paired assessments and Likert-scale ratings of clinical plausibility, confidence, and risk of misleading interpretation, supplemented by qualitative feedback. Although personalized synthetic MRIs appeared technically plausible, expert interpretation highlighted variability in con-fidence and potential risks of misleading cues when routine clinical data was embedded into image generation. These findings suggest that while personalized synthesis may be technically feasible, careful assessment is needed to understand how generated cues influence clinician interpreta-tion before such systems can be safely integrated into clinical workflows.

0.33
22

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33
23

Modality Contribution Score - A Per-Patient Framework for Quantifying the Relative Diagnostic Contribution of Structural MRI and Amyloid PET in Alzheimer's Disease

eess.IV cs.AIcs.CVcs.LG ·2026-08-23 ·Dawa Chyophel Lepcha, Aaliya Ali, Sophie A. Martin, Deepika Koundal, Pierrick Coupe +1 more
Abstract · 15 pages, 7 figures, Under review

Multimodal neuroimaging combining structural MRI and positron emission tomography (PET) captures complementary structure-function relationships across the Alzheimer's disease (AD) continuum, yet existing artificial intelligence systems produce a single diagnostic label without quantifying which imaging modality drove that decision for a specific patient. We introduce the Modality Contribution Network (MCNet) and the Modality Contribution Score (MCS), the first per-patient attribution framework quantifying the shift in modality dominance from structural atrophy to amyloid and metabolic dysfunction across the cognitively normal to MCI to AD continuum. MCS is normalised to unity per subject via modality ablation (MCS_MRI_i + MCS_PET_i = 1.0 for every subject i), providing an interpretable, clinically actionable score that fluid biomarkers cannot supply. Applied to 327 ADNI-3 participants balanced across cognitively normal, mild cognitive impairment, and AD groups, MCNet achieved competitive three-class staging performance (AUC=0.881). The MCS revealed a statistically significant monotonic gradient (Kruskal-Wallis p<0.0001), with increasing PET dominance from cognitively normal (MCS_PET 0.412+/-0.229) through MCI (0.489+/-0.289) to AD (0.671+/-0.426), validated against amyloid SUVR (r=0.172, p=0.006) and FDG metabolic biomarkers (r=-0.287, p=0.0005) from separate imaging pipelines. External replication in 1,073 independent OASIS-3 subjects confirmed cross-cohort generalisability (H=166.99, p<0.0001, eta^2=0.156). A mechanistic comparison with SHAP demonstrated that ablation-based MCS captures clinically meaningful modality dependence that deviation-based methods cannot. These findings position MCNet as a foundation for personalised imaging decisions, clinical trial stratification, and trustworthy AI in dementia care.

0.32
24

CiUNet: A Hybrid Swin-CNN UNet for Medical Image Segmentation

eess.IV cs.CV ·2026-08-23 ·Bin Dong, Jinghong Chen
code/data
Abstract · 14 pages, 3 figures. The demo predictor and trained weights are available at:https://github.com/ciphoBD/CiUNet

Medical image segmentation requires high accuracy and robustness, yet practical commercial deployment also demands privacy preservation and computational efficiency. In this context, the U-Net architecture, which can be inherently decoupled into independent encoder and decoder components, serves as a natural commercial choice. However, pure Transformer-based variants like Swin-UNet often suffer from insufficient local detail capture and limited interpretability. In this paper, we propose a lightweight hybrid architecture built upon the Swin-UNet framework. Our model integrates a parallel CNN encoder to complement the shallow layer reasoning of Swin Transformers with local texture features. To bridge the semantic gap and enhance fine-grained spatial detail recovery, we design an asymmetric feature fusion strategy and introduce cross-layer skip (XSkip) connections that explicitly propagate shallow CNN features into the decoder. We further incorporate novel loss functions and an auxiliary supervision head (Aux-Head) to strengthen training stability, boundary delineation, and intermediate feature interpretability. Extensive experiments on the Synapse multi-organ segmentation dataset demonstrate that our approach achieves state-of-the-art competitive Dice scores and Hausdorff distances, offering an accurate, efficient, and interpretable solution for clinical deployment.

0.32
25

Local SVD-Entropy Maps as a Complementary Structural Representation for Full-Reference and No-Reference Image Quality Assessment

eess.IV cs.CVcs.MM ·2026-08-23 ·Andrei Velichko, Petr Boriskov
Abstract · 24 pages, 8 figures, 7 tables, 48 references

We investigate a local spectral-complexity representation for perceptual image quality assessment (IQA) based on Shannon entropy of singular values computed directly from two-dimensional image patches. For each $3\times3$-pixel grayscale patch, SVD is applied directly and the normalized singular-value entropy defines one HSVD-map value. The construction requires neither flattening nor delay embedding, uses no boundary padding, and is invariant to $90^{\circ}$ rotations and mirror reflections at the local-descriptor level. A nested salt-and-pepper experiment on Lena separates absolute similarity to a clean reference from sensitivity to an additional degradation step. HSVD-SSIM responds more strongly to local corruption and retains a larger neighboring-state response at severe noise levels. Validation on all 10,125 distorted KADID-10k images shows that HSVD-SSIM is weaker than conventional SSIM as a standalone full-reference metric (SRCC $0.450$ vs. $0.619$), but complementary when combined with it: grouped cross-validation increases SRCC from $0.618$ to $0.659$, with a bootstrap 95\% confidence interval of $[0.036,0.046]$ for the gain. In a no-reference experiment, adding HSVD-derived single-image descriptors improves the best nonlinear model from SRCC $0.528$ to $0.575$ (95\% CI $[0.033,0.061]$) and also improves prediction of quality changes between neighboring distortion states. These results support direct local SVD entropy as an interpretable structural channel that complements conventional image-domain similarity and remains informative without a pristine reference.

0.32
26

HiFiC-G: Adapting HiFiC for Hi-C Contact Matrices

eess.IV cs.CVq-bio.GN ·2026-08-19 ·Andre Antonio Straton
Abstract · 13 pages, 3 figures, 2 tables. Bachelor's thesis project, Transilvania University of Brasov (UNITBV). Language editing and translation assis…

We study whether the loss design of High-Fidelity Generative Image Compression (HiFiC), a GAN-based neural codec originally built for natural photographs, can be adapted to preserve biologically meaningful structure in Hi-C chromatin contact maps under lossy compression. Standard image compression, including HiFiC in its original form, optimizes for human visual perception; but a Hi-C contact map is normally distributed together with its numeric matrix file (.cool/.mcool), which downstream genomic analysis tools consume directly. Aggressive compression that looks acceptable to the eye can nonetheless blur or delete loops and topologically associating domain (TAD) boundaries that these tools depend on. We modify HiFiC's distortion term with a spatially-weighted MSE that up-weights biologically salient regions (loops, TAD boundaries, stripes, compartment structure) and add an insulation-score loss term that directly penalizes loss of TAD boundary sharpness. We describe a three-phase fine-tuning strategy that adapts a pretrained HiFiC checkpoint to the Hi-C domain without catastrophic forgetting. We evaluate the resulting system, HiFiC-G, using both conventional image-quality metrics (PSNR, SSIM) and genomics-domain preservation metrics (loop/TAD/compartment/stripe preservation percentage) across two cell lines. HiFiC-G preserves local structure, meaning stripes and TAD boundaries, substantially better than the metrics alone would suggest, while long-range A/B compartment structure remains poorly preserved; we show this gap tracks genomic scale and is consistent with a specific architectural cause, the fixed-size tiling that both HiFiC-G and the original HiFiC rely on for memory efficiency.

0.31
27

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31
28

Loss-Resilient Semantic Communication over Packet-Loss Networks at Extreme-Low Bandwidth

eess.IV ·2026-08-20 ·Shengshi Yao, Jincheng Dai, Sixian Wang, Guo Lu, Kai Niu +3 more
top venue
Abstract · Accepted to appear in IEEE TMC. 14 pages, 15 figures, and 5 tables

In extreme-low bandwidth network scenarios, generative semantic codecs have emerged as promising solutions to reduce bandwidth cost for visual communications. However, these learned codecs are usually optimized solely for compression efficiency and thus not robust against transmission errors. Corruptions due to packet-loss among these highly compact generative latent representations often cause more critical degradation in fidelity and realism, intensified by the severe error propagation across the latent contexts and multi-step decoding process. In this paper, we propose ResiGLC, a novel loss-resilient generative latent coding framework designed for robust semantic communication over extreme-low bandwidth packet-loss networks. Motivated by the inherent goal-consistency between generation and compression, we sufficiently exploit the impressive in-context predictive capabilities of language models. Integrated with the masked learning strategy, our model supports arbitrary context modeling of latent codes, which could mitigate the error propagation and handle unpredictable packet loss patterns. At the receiver, a progressive resilient decoding pipeline is presented, which leverages both the contextual relationship of the latent codes and the multi-modal semantic prior in the generative latent space, separately. By jointly optimizing toward both compression efficiency and packet-loss resilience, our proposed progressive decoding mechanism offers graceful performance when dealing with dynamic packet losses. Through extensive experimental evaluations, we establish that under packet-loss network conditions, ResiGLC can effectively improve the loss-resilience in terms of perceptual fidelity and realism qualities with extreme-low bandwidth cost.

0.31
29

Emotion Across Speech and Faces: Shared Affective Mechanisms in Multimodal Foundation Models

cs.CL eess.ASeess.IV ·2026-08-17 ·Xiutian Zhao, Luqi Sun, Björn Schuller, Berrak Sisman
Abstract · 9 pages, 4 figures

Modern multimodal foundation models (MFMs) have made rapid progress on tasks requiring integrated perception across speech, vision, and language, including emotion recognition. However, it remains unclear whether they recognize speech and facial emotion through shared affective functional units or modality-specific pathways. We explore emotion-sensitive neurons (ESNs), sparse decoder neurons selectively associated with emotion categories, in three MFMs: Gemma-4-12B-it, MiniCPM-o-4.5, and Qwen2.5-Omni-7B. Using speech emotion recognition and facial expression recognition as complementary probes, we identify acoustic and visual ESNs. Visual ESNs are causally meaningful: deactivating them selectively impairs recognition of the associated facial emotion, whereas steering their activations selectively enhances recognition of that emotion relative to other emotion categories. Acoustic and visual ESNs further show emotion-matched overlap and similar layer-wise distributions, indicating partial structural alignment between affective representations across speech and faces. Finally, cross-modal interventions reveal bidirectional causal transfer: ESNs identified from one modality produce emotion-specific effects when applied to the other. Our findings provide one of the first cross-modality activation-level analyses of affective functional units in MFMs, suggesting that speech and facial emotion recognition partially converge onto sparse decoder-level components that can be localized and manipulated without training.

0.30
30

QuARC-GS: Quantized Anchored Residual Coding for Compact Dynamic Scene Streaming with Gaussian Splatting

eess.IV cs.CV ·2026-08-18 ·Vu Trung Nghia Nguyen, Yuchen Wang, Kyung Chul Lee, Kevin C. Zhou
Abstract · 9 pages, 5 figures, 3 tables

3D scene representation techniques such as neural radiance fields (NeRFs) and Gaussian splatting have made substantial progress in novel view synthesis, achieving high-quality renderings from arbitrary view angles. More recently, such techniques have been extended to dynamic 3D scenes; however, achieving sustainable online free-viewpoint video (FVV) streaming remains challenging, especially for longer videos, due to significant storage demands of detailed scene representations and high reconstruction/rendering speed needs. To address these challenges, we propose Quantized Anchored Residual Coding Gaussian Streaming (QuARC-GS), a quantization-aware 4D scene optimization framework for online dynamic scene reconstruction that achieves ultra-high compression while maintaining reconstruction speed and quality. QuARC-GS represents a scene using a single canonical frame and highly compressed per-frame residuals. Specifically, we compress each residual through two complementary strategies targeting motion, appearance, and densification. We introduce quantization-aware anchor deformation, which suppresses insignificant motion updates while preserving meaningful deformations, maintaining reconstruction quality under low-storage streaming. Furthermore, we design a change-gated densification strategy that allocates new Gaussians only in regions exhibiting genuine temporal changes, effectively eliminating redundant appearance updates and reducing storage overhead. Extensive experiments on widely used datasets demonstrate that QuARC-GS enables competitive reconstruction quality and training speed while cutting per-frame storage by up to 11$\times$ compared to the state-of-the-art.

0.30
31

Noise Stability and Rotational Equivariance of Image-Induced Hamiltonian Spectra for Robust Unsupervised Segmentation

eess.IV ·2026-08-20 ·Soumic Sarkar
unusual
Abstract

Unsupervised segmentation methods that embed an image as the potential of a Schrödinger-type Hamiltonian and read out object structure from its low-lying eigenstates have demonstrated strong empirical performance across natural and volumetric imagery, yet the robustness of this spectral representation to sensor noise and geometric transformation has never been established theoretically. This paper closes that gap. A discrete graph-Hamiltonian formulation is adopted, consistent with existing quantum-inspired segmentation frameworks, and an explicit finite-sample perturbation bound is derived that links the drift of its eigenvalues and ground-state eigenvector under additive noise of known variance to the operator's spectral gap, extending a one-dimensional noise-error analysis originally developed for semiclassical signal analysis to the two-dimensional graph setting used in image segmentation. The eigenvector-level bound is further propagated to the induced binary segmentation mask, giving, for the first time, a quantitative guarantee on segmentation stability under noise rather than an empirical observation of it. A complementary equivariance analysis characterizes the conditions under which the operator's spectrum transforms exactly under the planar rigid-motion group, and quantifies the equivariance gap introduced by anisotropic potential terms commonly used in practice. Theoretical predictions are validated numerically on natural-image and noise-perturbed benchmarks, showing close agreement between the derived bounds and observed spectral and segmentation-mask deviation, and offering practitioners a principled criterion for selecting operator parameters under known noise conditions.

0.29
32

AerialYield-B2D: A Greenhouse Blueberry Dataset with Five-Stage Ripeness Masks and Fruit Counts

cs.CV eess.IV ·2026-08-17 ·Iyyakutti Iyappan Ganapathi, Afeefa Azam, Muhammad Owais, Irfan Hussain, Yusra Abdulrahman
unusual
Abstract

Blueberry ripeness is judged by berry colour, cluster composition, and the distribution of maturity stages within a plant, however, public green house image resources with dense ripeness-stage masks remain limited. We present AerialYield-B2D, where B2D denotes BlueBerry Dataset, acurated real-image resource containing 514 RGB images and 30,195 annotated blueberry instances across five ripeness stages: green immature, pale pink, pink-turns-purple, fully ripe and over-ripe. The release provides class-specific binary masks, overall berry masks, semantic label maps, image-level count tables, SHA-256 hashes, source metadata, recommended train/validation/test splits and technical validations. AerialYield is the broader project name; this release does not provide harvest weight, fruit mass or per-area yield measurements, and the count labels should therefore be interpreted as image-level berry counts rather than yield estimates. The images include 424 smartphone greenhouse images, 67 video-derived frames, and 23 DJI Fly video-frame samples, providing a reproducible dataset for ripeness segmentation, berry counting, and class-imbalance analysis in controlled-environment blueberry production.

0.28
33

Simulation-to-Real First-Break Segmentation for Efficient Inversion in Musculoskeletal Ultrasound Tomography

eess.IV eess.SP ·2026-08-20 ·Yifei Sun, Yubing Li, Yannick Benezeth, Stéphanie Bricq, Yunrong Zhang +4 more
unusual
Abstract

Full-waveform inversion (FWI) is a promising strategy for quantitative musculoskeletal ultrasound computed tomography (USCT), but bone-related scattering, attenuation, and signal degradation make it highly sensitive to the accuracy of the initial acoustic-property distributions and prone to cycle skipping. First-arrival traveltimes provide important kinematic information for initial-model construction, yet conventional trace-wise picking is unreliable when arrivals are weak, spatially heterogeneous, or buried in system noise. We propose a learning-assisted reconstruction pipeline that combines segmentation-based first-arrival extraction with hybrid full-waveform inversion (HFWI), which incorporates Rytov-approximation-based traveltime information together with waveform fitting during the early inversion stage. A lightweight 2D U-Net treats the first-arrival trajectory across receiver channels as a first-break segmentation target and exploits its spatial continuity rather than processing each trace independently. To address both limited manual annotations and the simulation-to-real gap, the network is pretrained on task-specific simulations augmented with real system-noise recordings, followed by stage-wise training with progressively increased signal degradation and decoder-only fine-tuning using limited weakly labeled experimental data. The method is evaluated on in vitro phantom, ex vivo bovine-limb, and in vivo human-thigh datasets. Compared with conventional STA/LTA picking, the proposed network yields more spatially coherent first-arrival trajectories, lower mean extraction errors, and processes a full-matrix-capture dataset within seconds. When integrated into HFWI, the extracted arrivals improve initial-model construction and lead to stable subsequent FWI reconstructions, including challenging cases with estimated local first-arrival SNRs below 3 dB.

0.28
34

Pretreatment DCE-MRI Resolves Response Quality Within Pathologic Endpoints in Neoadjuvant Breast Cancer

eess.IV cs.CVcs.LGq-bio.QM ·2026-08-22 ·Dattatreya Kantha, Murray H. Loew
Abstract

Pathologic complete response (pCR) is a strong neoadjuvant endpoint, yet 5-15% of complete responders recur and clinical/genomic variables do not reliably identify them. We tested whether pretreatment dynamic contrast-enhanced MRI entropy - intratumoral enhancement heterogeneity - resolves response quality hidden within pCR and residual cancer burden (RCB). Across four cohorts (1,200 patients), a prespecified entropy threshold defined favorable and adverse structural states. Crossing structure with pathology yielded a four-tier framework spanning 4.1-fold recurrence in I-SPY1 and 7.7-fold at response extremes. In I-SPY2, 55 of 219 complete responders (25.1%) were structurally adverse, pretreatment. In an external HER2-positive responder synthesis (I-SPY1 pathology-confirmed pCR plus UCSF best-response proxy; n = 33, 10 events), adverse structure was associated with higher recurrence risk (HR = 2.87, 95% CI 1.38-5.96) capturing 7 of 10 recurrences, enriching rather than determining risk. In a HER2-positive RCB-0 subset, recurrence was 12.5% with favorable and 80.0% with adverse structure; Firth Cox regression preserved the association (HR = 8.13, 95% CI 1.71-49.21; n = 21, 6 events). In Duke (n = 908; 76 events), favorable structure remained independently associated with lower distant-recurrence risk (adjusted HR = 0.61, 95% CI 0.41-0.91). RNA linked favorable structure to a directionally reproduced immune-architecture program among non-overlapping patients within ISPY2; EMT-pathway enrichment was favorable-side, while the adverse tier contained a broadly immune-depleted substate. Yet full-cohort RNA models weakly discriminated structural state and did not recover continuous entropy. Pretreatment MRI therefore does not replace pCR or RCB; it reveals response-quality differences that these endpoints compress and identifies a recurrence-enriched group for prospective validation.

0.28
35

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

eess.IV cs.CV ·2026-08-21 ·Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte
benchmark
Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

0.27
36

Image Denoising Using Lower Semi-Frames

eess.IV cs.CV ·2026-08-21 ·Hemalatha M, P. Sam Johnson
Abstract

A blind image denoising framework based on an infinite directional lower semi-frame (DLSF) is proposed for additive white Gaussian noise. The model employs scale-dependent directional analysis with resolvent regularization of the unbounded semi-frame operator. Noise variance is estimated directly in the DLSF domain by modeling the joint covariance of four directional difference channels and applying covariance whitening to obtain a chi-square statistic. A lower-tail moment estimator provides blind noise estimation without median absolute deviation. The estimated noise level is incorporated into channel-wise Wiener-type shrinkage and canonical-dual synthesis, followed by a data-consistent iterative reconstruction with automatic stopping. Experiments on three standard grayscale images at noise levels 15--30 yield a mean relative noise-estimation error of 3.28\%, with average improvements of 7.45 dB in PSNR and 0.367 in SSIM. At 30/255 noise, the estimation error decreases to 1.73\%, with a mean PSNR gain of 8.31 dB. Results demonstrate effective noise suppression and structural preservation, with the strongest performance on smooth and edge-dominated images.

0.27
37

Precision-Aware Variable Bit Processing Elements for Hardware-Efficient Systolic Array Designs

cs.AR cs.ETcs.LGeess.IV ·2026-08-23 ·Dantu Nandini Devi, Madhav Rao
published
Abstract

Systolic arrays (SAs) have emerged as prominent hardware accelerators for matrix operations in deep learning, while floating point number formats enable precision control across computational domains. This research investigates approximate computing techniques for floating point (FP) multipliers in Weight Stationary Systolic Arrays, focusing on IEEE 754 (FP32), TensorFloat-32 (TF32), and Brain Floating point (BF16) formats. By integrating partial product matrix (PPM) column truncation with positive and negative compressors in the FP multiplier architecture, we optimize the trade-off between computational efficiency and accuracy. NSGA-II optimization algorithm was employed to explore the vast design space for evolving FP multiplier designs, towards achieving substantial hardware improvements while maintaining acceptable output quality. Substantial hardware benefits were observed in the FP multiplier designs across various applications, while preserving output quality. The FP approximated Processing Elements designed in the SA was found to offer comparable CNN accuracy for models trained on MNIST, F-MNIST, and CIFAR-10 dataset. The FP approximated SA designs that fall in the top 10 CNN performance offered substantial hardware gains in the range of 66% to 92% footprint savings, 60% to 93% of power benefits with 21% to 54% improvement in the delay when compared with the corresponding exact implementations mentioned in the literature for running the model trained on CIFAR-10 dataset. The TF32 and BF16 approximated SA designs also achieved substantial gains while maintaining comparable CNN accuracy. Our findings confirm that targeted approximation in FP multiplier design significantly improves the efficiency of hardware accelerators for error-tolerant applications, establishing an effective approach to hardware resource optimization in contemporary computing architectures.

0.27
38

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

eess.IV cs.CV ·2026-08-18 ·Buket D. Barkana
Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

0.27
39

What Matters is the Prompt: Prompt Sensitivity and Prompt Generation in Foundation Models for Lung Nodule Segmentation

eess.IV ·2026-08-17 ·Jorge F. Lazo, Xixi Liu, Andreas Hallqvist, Mikael Johansson, Åse Johnsson +3 more
Abstract

Lung nodule segmentation in computed tomography is essential for extracting clinically relevant information for lung cancer assessment and treatment planning. Foundation models have shown notable segmentation capabilities, but state-of-the-art approaches often depend on input prompts, such as points or boxes, making their performance sensitive to prompt quality and placement. Understanding the limitations and constraints of prompt-based foundation models is therefore essential for designing reliable medical image segmentation solutions. In this work, we investigate how prompt quality affects foundation models performance for lung nodule segmentation. We further propose a synthetic prompt-generation model to test if the dependence on manually provided prompts can be mitigated by generating synthetic prompts that can also improve segmentation performance. Perturbation experiments show that bounding box prompts generally outperform point prompts, while latest specialized medical imaging models achieve better performance than general purpose ones. The proposed approach obtains a Dice coefficient of 0.85, suggesting that synthetic prompt generation as a promising strategy for lung nodule segmentation with foundation models.

0.26
40

MOSAIC: Modality-agnostic Spectral Alignment for Federated Image-level Weakly Supervised Tumor Segmentation under Client-specific Missing Modalities

eess.IV cs.CV ·2026-08-20 ·Tarun Kumar Garg, Vaanathi Sundaresan
code/data
Abstract

Trustworthy multimodal fusion in clinical settings requires handling incomplete and heterogeneous modality subsets across institutions, where privacy constraints prohibit centralized data sharing. Federated learning (FL) mitigates data-sharing constraints but suffers from client-specific missing modalities, where institutions possess incomplete multimodal subsets, degrading fusion quality and segmentation performance. While FL and weak supervision have been studied separately, their joint use with image-level labels under heterogeneous missing modalities remains unaddressed. We propose \textbf{MOSAIC}, the first modality-agnostic federated framework for weakly supervised binary tumor segmentation under client-specific missing modalities. We introduce a client-specific modality-alignment module that fuses available channels into a shared latent space without prior knowledge of modality identity, a spectral prototype alignment loss that reconciles cross-client distribution shift using compact non-invertible frequency-domain statistics, and a dedicated federated refinement network that denoises the resulting CAM pseudo-labels into accurate masks, breaking the accuracy ceiling of weak supervision. Experiments on three multi-institutional brain tumor benchmarks (FeTS2022, BraTS-MEN, and BraTS-SSA) demonstrate significant improvements over all image, box, and point-supervised baselines, approaching fully supervised accuracy using only image-level labels and reaching 0.84 Dice on FeTS2022. Dynamic new client addition enables previously unseen institutions to join an already-trained federation within 0.01-0.04 Dice without retraining. Code is available at https://github.com/Tarun2201/MOSAIC.

0.24
41

SatoyamaCT: A Multi-Axis Night-IR Camera-Trap Benchmark for Monitoring Crop-Damaging Wildlife in Japanese Agroforestry

eess.IV q-bio.QM ·2026-08-19 ·Keito Inoshita, Kohei Hisayama, Haruto Sugeno, Kota Nojiri
benchmarkdataset
Abstract

Crop and forest damage from sika deer, wild boar, and Japanese macaque is a serious economic problem in Japanese satoyama, where farmland and forest intermingle. Camera traps enable scalable monitoring, yet existing benchmarks evaluate recognition in-distribution, rarely prioritize night infrared imagery, and do not jointly address regional domain shift, novel-species detection, and uncertainty-based triage on a single dataset. We introduce the Satoyama Camera Trap Dataset (SatoyamaCT), 12,642 expert-verified crops from night-IR-dominant camera traps across three satoyama regions. An iterative annotation protocol combining BioCLIP embeddings with confidence-ordered confirmation reduced expert effort while all labels were verified by domain ecologists; species-level inter-annotator agreement reached Cohen's kappa = 0.900. A multi-axis protocol jointly evaluates domain generalization across region, camera placement, and illumination; open-set novel-species detection; and selective prediction, all under capture-event-based leakage control. Difficulty separates into distinct failure modes: a data-inherent regional gap of 16 to 27 percentage points persists in Wakayama across four backbones and domain-generalization methods including CORAL, DANN, and GroupDRO, and open-set detection reaches AUROC 0.93 to 0.96 overall yet degrades jointly with classification in Wakayama. Selective prediction recovers Wakayama accuracy from 0.593 to 0.815 at 50% coverage, supporting an uncertainty-aware triage workflow for practical pest monitoring in agroforestry.

0.24
42

Energy-Mamba: A Physics-Constrained State-Space Model for Medical Image Classification

eess.IV ·2026-08-20 ·Mohamed Mabrok, Yalda Zafari, Essam A. Rashed
published
Abstract · This paper was accepted to the MICCAI 2026 workshop MLMI

State-Space Models (SSMs), particularly Mamba, offer linear-time complexity for long-range dependencies, making them attractive for medical imaging with limited annotated data. However, adapting these sequential models to 2D images through unconstrained state evolution causes representational drift, the dynamic hidden state progressively loses fidelity to local image features. We introduce Energy-Mamba, integrating SSM dynamics with physics-informed constraints via a learnable potential energy function that quantifies compatibility between evolving states and static local features. Our Energy-Mamba Block introduces a gradient-based forcing term, computed dynamically via automatic differentiation, that pulls states toward low-energy configurations maintaining local visual fidelity. This formulation mirrors Hamiltonian dynamics: kinetic energy (SSM scan) plus potential energy (our constraint function) govern state trajectories. This architectural prior enables learning implicit constraints for robust, faithful representations, crucial in medical imaging where fine-grained local detail drives accurate diagnosis. Evaluated on four datasets (retinal OCT, chest X-ray, microscopy, abdominal CT), Energy-Mamba achieves state-of-the-art classification performance with significantly fewer parameters, demonstrating that physics-informed grounding can enhance both efficiency and representational quality in medical vision tasks.

0.24
43

LiteEvent-AE: Lightweight Autoencoder for Event-Based Vision on Low-Latency Energy-Constrained Edge Devices

cs.CV cs.AIeess.IV ·2026-08-22 ·Riadul Islam, Joey Mule, Dhandeep Challagundla, Shahmir Rizvi, Sean Carson +1 more
Abstract

Event-based vision has emerged as a promising paradigm for energy-aware artificial intelligence (AI), offering sparse, low-latency visual signals that reduce redundant data processing and support sustainable edge computing. However, the asynchronous and noise-prone nature of event streams creates challenges for conventional deep learning models, which are often too computationally intensive for low-power embedded platforms. This work presents a compact and configurable event-driven autoencoder that efficiently compresses neuromorphic data while preserving essential spatiotemporal structure for downstream inference. The architecture integrates lightweight convolutional encoding with robust performance under adaptive event thresholding and a minimal classifier head, enabling substantial reductions in computational cost without degrading recognition fidelity. Extensive evaluations on the Smart Event Face Dataset (SEFD) and Event-Based Crossing Dataset (EBCD) show that the proposed framework achieves competitive or superior accuracy compared to YOLOv9 while requiring up to 35.6$\times$ fewer parameters. To assess real-world sustainability, the model is deployed on resource-constrained hardware: a Raspberry Pi 4B and a NVIDIA Jetson Nano. On NVIDIA Jetson Nano, it delivers real-time throughput of 44.8 FPS. On a Raspberry Pi 4B CPU, the 50\% autoencoder classifier consumes 16.19 J for the evaluated inference workload, corresponding to approximately 726.3$\times$ lower energy consumption than YOLOv9 under the same evaluation protocol. These results demonstrate the potential of compact event-driven models to advance environmentally conscious, low-power AI systems for high-speed perception in autonomous, mobile, and embedded computing environments.

0.24
44

Deep Learning for Automated Quantification of Tumor-Associated Macrophages from H&E-Stained Slides in Diffuse Large B-Cell Lymphoma

eess.IV ·2026-08-19 ·Anastasiia Studenikina, Svetlana Illarionova, Joaquim Carreras, Daniil Sulimov, Olga Filimonova +5 more
Abstract · 17 pages, 5 figures, 7 tables

While M2-polarized tumor-associated macrophages (TAMs) have been established as indicators of disease aggressiveness in diffuse large B-cell lymphoma (DLBCL), traditional CD163 immunohistochemistry (IHC) remains resource-intensive. This study aims to investigate the feasibility of using deep learning to quantify TAMs directly from standard hematoxylin and eosin-stained (HE) tissue sections. Using a curated dataset of 52 patients with DLBCL, with high-resolution HE images and IHC-validated annotations (1,713 TAM instances), five architectures were evaluated: U-Net, Swin-U-Net, Cerberus-U-Net3+, YOLOv11, and HoVer-Net. High CD163 TAM density (>20.04%) was associated with significantly reduced overall survival (HR 2.73; 95% CI:1.21-6.16; p=0.012) and progression-free survival (HR 2.88; 95% CI: 1.23-6.76; p=0.011). In multivariate Cox proportional hazards analysis adjusting for IPI, molecular subtype (GCB/non-GCB per Hans algorithm), EBV status, and age, CD163 TAM density showed a prognostic trend for overall survival (HR 3.24; 95% CI: 0.94-11.15; p=0.062) and progression-free survival (HR 2.41; 95% CI: 0.80-7.32; p=0.120). Among the evaluated models, the domain-specific Cerberus-U-Net3+ achieved the highest sensitivity (Recall 0.656), while the Transformer-based Swin-U-Net demonstrated superior segmentation fidelity (Precision 0.694, F1-score 0.633). Additionally, the survival analysis based on the predicted Swin-U-Net CD163 level revealed a 20.8% cutoff point for patients with high and low CD163 levels near IHC, as well as a downward trend in overall survival among patients with higher predicted CD163 values of 2.63 (95% CI: 0.85-8.33; p=0.083). These findings suggest that deep learning architectures using shifted-window self-attention show potential as a candidate surrogate for IHC that is scalable and cost-effective for prognostic assessment of TAMs in DLBCL.

0.22
45

Iterative Grasp Pose Refinement: A Deep Reinforcement Learning Approach for 2D Vision

cs.RO cs.AIcs.LGeess.IV ·2026-08-18 ·Amir Arsalan Nematollahi, Shayan Ahmadi, Mehdi Tale Masouleh, Ahmad Kalhor
Abstract

Developing robots capable of understanding and manipulating objects requires compact, interpretable, and generalizable representations. This work proposes a reinforcement learning-based framework for robotic grasp refinement, integrating keypoint-based object representations with a Deep Q-Network (DQN). Using 2D overhead images captured in a simulated environment, a geometric-based algorithm generates initial grasp candidates, which are iteratively refined by the proposed framework, transforming failed grasps into successful ones. Experiments conducted on 300 objects from the Dex-Net dataset using a UR5 manipulator demonstrate the framework's effectiveness, achieving a 100% success rate on objects previously deemed ungraspable by geometrical methods. The framework's sim-to-real transferability is further validated through physical experiments on a Delta parallel robot, where a refined grasp successfully manipulates an object that was previously ungraspable. The findings underscore the effectiveness of reinforcement learning in addressing challenges in robotic grasping, offering a scalable and adaptable solution for contact-rich manipulation tasks.

0.22
46

Single-Model Adaptive Wireless Image Transmission via Feature Sparsity Regularization

eess.IV cs.IT ·2026-08-22 ·Xianghao Cui, Li Lan, Qi He, Bo Che, Chenyuan Feng +2 more
Abstract · 16 pages, 13 figures, including supplementary material. v2: Incorporated the supplementary material into the PDF and refined cross-reference…

Learned joint source-channel coding (JSCC) enables robust wireless image transmission by jointly optimizing the transmitter and receiver over differentiable channel models. For bandwidth-limited and time-varying visual links, a single model should support user-adjustable transmission rate and adapt to changing wireless channel conditions, while also dynamically allocating resources according to spatial content. Existing content-adaptive or dynamic allocation schemes often rely on entropy coding, context/probability prediction, explicit rate maps or masks, or auxiliary allocation networks, complicating the encoder-decoder pipeline and increasing side-information overhead. We propose TS-JSCC, a single-model adaptive JSCC framework with tail-structured sparsification. First, an L1-based tail-structured sparsification objective encourages each token to retain an active feature-channel prefix while suppressing trailing ones. This enables content-adaptive feature-channel allocation with compact side information through active-prefix transmission. Second, lightweight stage-wise neural regulating modules use a normalized sparsity-control coefficient and the channel signal-to-noise ratio (SNR) to rescale intermediate features for single-model transmission rate and SNR adaptation. Experiments on CIFAR-10, Kodak, and CLIC2021 under additive white Gaussian noise (AWGN) and Rayleigh fading show that TS-JSCC achieves strong rate-distortion performance against the latest learned-JSCC baselines and remains competitive with the considered idealized separation baselines, while retaining a simple one-shot encoder-decoder without extra structures or computations.

0.21
47

Multimodal pseudo-CT synthesis for PET attenuation correction using separate modality encoding and topogram conditioning

eess.IV cs.CVphysics.med-ph ·2026-08-21 ·Rory Bell, Artemis Bouzaki, Jiaming Cao, Jasmine Morrison, Chelsea Sargeant
code/data
Abstract · Technical report for the BIC-MAC 2026 Challenge

We participated in the BIC-MAC Challenge with a multimodal 3D patch-based U-Net for pseudo-CT generation from NAC-PET, MRI, and 2D topograms. By using separate PET and MR encoders, multi-scale feature fusion, and FiLM-based topogram conditioning at the bottleneck, we obtain a model that integrates complementary cross-modal information while reducing reliance on precise voxel-wise correspondence between modalities. Our final submission can be found: https://github.com/rrr-uom-projects/BIC-MAC-MICCAI2026

0.17