CS Paper Radar

Weekly top 50 · eess.IV

2026-W46 Nov 09 – Nov 15, 2026

Ranked from 3,982 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Do Underwater Image Quality Metrics Agree with Human Perception? A Benchmark with Human Choices, Simple Edits and Generative Drift

cs.CV eess.IV ·2026-11-13 ·Rishii Kumar Singh, Abhinav Rajput, Dinesh Kumar Vishwakarma
publishedbenchmarkcode/data
Abstract · Accepted at the 6th WVAQ Workshop, WACV 2027. 18 pages including appendix

Underwater image enhancement is challenging to evaluate due to the lack of clean reference images, so researchers rely on no-reference image quality assessment (NR-IQA) metrics. However, it remains unclear whether these metrics agree with human judgments. We evaluate 73 handcrafted underwater, learned underwater, vision-language and general-purpose metrics against human preferences on five references: four published opinion-score sets and a new paired-comparison study. For each metric, we measure how often it selects the same image as people when comparing versions of the same scene. We further test whether simple image edits and small adversarial perturbations raise metric scores above the enhancement people preferred, and whether scores decrease as repeated generative edits add noise. Our results show that no metric consistently matches human preferences. The best worst-case Cohen's kappa over the five references is only 0.23 (Q-Align), while two raters in our study agree with a median kappa of 0.41. The widely used UCIQE often favors edits that people reject. On a Nano Banana Pro replica chain that should leave the image unchanged, only 22 of 73 scores decrease at every checkpoint, while noise grows by 2.5 times. We also introduce TrustUIQA, a benchmark that combines the human references, our study choices, the edited, attacked and generated images, and the scores of every metric on every image. The code is available at https://github.com/TrustUIQA/TrustUIQA and TrustUIQA at https://huggingface.co/datasets/TrustUIQA/TrustUIQA.

0.54
2

Distribution Shift Detection in Remote Sensing Imagery using Machine Learning Models

cs.CV cs.LGeess.IVeess.SP ·2026-11-10 ·Abdullah Almansour, Ozan K. Tonguz
publishedcode/datahot direction
Abstract · Accepted as a short paper at the 4th Workshop on Computer Vision for Earth Observation (CV4EO), held in conjunction with WACV 2027

Remote sensing imagery acquired by Unmanned Aerial Vehicles (UAVs) supports wide range of applications; however, deploying machine learning (ML) models on resource-constrained aerial platforms introduces challenges beyond predictive accuracy, particularly when deployment data differ from the distributions observed during training. Such shifts are common in remote sensing due to geographic, sensor, seasonal, and other visual variations. A practical solution is to equip deployed models with mechanisms that detect emerging distribution shifts and support subsequent responsive actions. This paper presents an empirical case study of three open-source detection tools: (i) Alibi-Detect; (ii) NannyML; and (iii) PyTorch-OOD. Using cross-dataset remote-sensing shifts, we evaluate both detection effectiveness and computational latency of these tools. Our results reveal differences in detection behavior and processing cost across methods and implementations, highlighting trade-offs between detection capability and response-time. These findings motivate further work toward lightweight, and latency-aware monitoring mechanisms for resource-constrained systems.

0.46
3

Learned Regularization for Sparse-View CT: Accuracy, Lesion Detectability and Distribution Shift of a Plug-and-Play Prior against Tuned Total Variation

eess.IV cs.CVeess.SP ·2026-11-13 ·Mohammed Abo Oraig
code/data
Abstract · 62 pages, 22 figures, and 30 tables. Preprint (not peer-reviewed); also available on Zenodo: https://doi.org/10.5281/zenodo.24107061. Code a…

Learned image priors are often proposed to replace hand-crafted regularizers in sparse-view computed tomography (CT), yet they are usually judged by PSNR on data resembling their training set. We evaluate one noise-conditioned DnCNN denoiser used as a Plug-and-Play prior against filtered back-projection (FBP), Tikhonov and total-variation (TV) regularization, with every method tuned on validation data and all differences paired. On synthetic 28x28 digit images, the prior beats box-constrained TV by about 3.4 dB at moderate noise (sigma = 0.05, 20 angles), but the advantage shrinks at low noise and reverses under distribution shift: an MNIST-trained prior is 3.1 dB (Fashion-MNIST) and 4.3-4.6 dB (Shepp-Logan phantom) below TV, whereas a Fashion-MNIST-trained prior beats TV by 2.2 dB on Fashion-MNIST, consistent with prior mismatch rather than a failure of PnP itself. In a lesion-insertion test the prior detects lesions worse than TV in distribution despite its higher PSNR, and under mismatch it produces more lesion-like false blobs than box-constrained TV for seven of eight lesion types. On real LoDoPaB-CT slices (patient-disjoint split; 30, 60 and 120 angles; three dose levels; 40 test patients), the prior does not consistently outperform a well-tuned TV in PSNR (-0.93 to +0.33 dB) and has lower SSIM in eight of nine conditions. Its lesion-detection AUC is higher than this TV's in all nine conditions (significant in six) but never significantly higher than that of Hann-filtered FBP, which the PSNR-tuned TV falls below in detection in all nine conditions (seven significant). On non-anatomical phantoms its PSNR falls below TV in all six conditions. PSNR and lesion detectability thus rank the methods differently. Our conclusions concern one small denoiser, and the CT analysis was developed after seeing results, without pre-specified primary comparisons.

0.42
4

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

eess.IV cs.AI ·2026-11-09 ·Ke Wang, Atakan Topcu, Hossein Momeni, Molin Zhang
code/data
Abstract · 18 pages, including 6 pages of Supporting Information. Code: https://github.com/KeWang0622/MRFoundry

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.

0.41
5

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/datahot direction
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38
6

Physics-Informed Generative Augmentation for Open-Set UAV Classification

eess.SP eess.IV ·2026-11-11 ·Michel Kulhandjian, Levon Aslanyan
published
Abstract · Accepted by ICT Express

Open-set recognition of unmanned aerial vehicles (UAVs) from passive 5G radar micro-Doppler signatures is challenging because unknown drone types cannot be anticipated at training time. We propose a physics-informed generative adversarial network (PI-GAN) that conditions spectrogram synthesis on rotor kinematics, forcing the classifier's feature space to encode physically meaningful structure. We compare PI-GAN augmentation against a vanilla conditional GAN (CGAN) and basic data augmentation across three held-out configurations with 1, 2, and 3 unknown classes. Vanilla CGAN augmentation collapses open-set clustering, reducing the adjusted Rand index (ARI) from 0.97 to 0.01, whereas PI-GAN preserves it at 0.97. In a controlled held-out sweep with two unknown classes, PI-GAN achieves an ARI of 0.92 compared to 0.07 for vanilla CGAN. The physics-informed features enable unsupervised separation of mechanically distinct unknown drones without retraining, demonstrating that physics-conditioned generation is the key enabler of open-set capability.

0.38
7

Mutual Colormap Dependence: How Recoloring Biomedical Images Changes Vision-Language Model Answers

eess.IV ·2026-11-11 ·Siddharth Vohra, Runmin Jiang, Min Xu
publishedcode/data
Abstract · Accepted to the FABRIC workshop at WACV 2027. 10 pages, 1 figure, 5 tables. Project page: https://siddvoh.com/mutual-colormap-dependence/

Vision-language models (VLMs) are being built to answer questions about biomedical images, yet they never see the measured intensities, only the colors that a colormap has assigned to them. For questions about image content, the colormap should not change the answer. We call the extent to which it does Mutual Colormap Dependence (MCD), the mutual information between the colormap and a model's answer, which is zero exactly when every colormap yields the same answer distribution. Because VLMs sample their answers, we compare recoloring with a control that uses the same number of calls to ask again about the unchanged gray image, so that ordinary resampling is not mistaken for an effect of the colormap. We test GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6, and Qwen3-VL-235B under six luminance-monotonic colormaps (gray, viridis, plasma, inferno, magma, and cividis) on 50 medical visual-question-answering items from 16 SLAKE images, 64 ChestX-ray14 chest radiographs, and 200 BBBC039 fluorescence-microscopy images for exact nucleus counting. Every prompt tells the model to ignore the colormap. Even so, with three answers per colormap on the chest radiographs, the answers of all four models depend on the colormap (all Holm-adjusted $p \leq 0.002$). For Claude, some colored map overturns the majority answer on 29 of the 64 radiographs, where resampling gray alone overturns about 4, and Qwen's accuracy falls from 0.54 under gray to between 0.32 and 0.41 under the colored maps, mostly because it abstains. With one answer per colormap, recoloring adds disagreement beyond repeated sampling in 5 of 12 model-panel cells under per-cell 95% intervals, and repeating the instruction to ignore color does not reliably reduce it. The colormap is therefore part of what a VLM sees, and it can change the answer.

0.37
8

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37
9

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36
10

Image Quality and the Reliability of Fabric-Density Measurement: Counting Threads from Smartphone Photos Through a Pick Glass

cs.CV eess.IV ·2026-11-09 ·Anoubhav Agarwaal
publishedbenchmark
Abstract · Accepted at the WVAQ workshop at WACV 2027

Thread density, the threads per inch along and across a woven fabric, is a basic specification that buyers check whenever fabric is sold. Without laboratory instruments, inspectors count it slowly, by eye, through a pick glass, a folding 10$\times$ magnifier with a one-inch window. A smartphone photo through that glass could make the check faster and leave a record. We judge such a photo by what it is used for, as in task-based image quality: it is good if the thread count from it is within $\pm$5% of the true count, a common tolerance in fabric specifications. We introduce PickGlass-TPI: 76 factory scenes of 44 fabric patches, each counted in an open annotation tool by a textile-trained annotator, whose counts are the reference. On it we benchmark frontier and open vision-language models, CNNs, counting specialists and a training-free spectral counter (PG-Lattice). No method agrees with the reference within the tolerance. The best methods are off by about a quarter: a small open model that we tuned only on synthetic images (Molmo2-4B, 25%) is level with the best frontier model, GPT-6.1-sol (27% when asked directly, 25% given four magnified close-ups of the window). Both err less than a non-expert annotator (37%), but only the tuned model also beats, on both error measures, a baseline that guesses each scene's density as the average of the others. PG-Lattice most often repeats its count within 5% across two photos of the same patch, but its misses, like GPT-6.1-sol's errors, are often a factor of two. Even the reference repeats a count across such re-shoots only to a median 9%, so one photo cannot yet be shown to meet $\pm$5%; the image quality that matters is reliability across re-shoots. Generic no-reference quality scores chosen before labeling do not rank PG-Lattice's error, and generative enhancement raises perceptual scores but does not reliably improve the count.

0.35
11

Data Archive for 2D and 3D Electrical Impedance Tomography with moderate conductivity contrast phantoms

eess.IV cs.LG ·2026-11-12 ·S. J. Hamilton, A. Hauptmann, A. Hänninen, V. Kolehmainen, J. Niskanen +2 more
code/data
Abstract · 11 pages, 6 figures. Data available at https://doi.org/10.5281/zenodo.24120439

This document describes open Electrical Impedance Tomography (EIT) measurement data that were collected from biomedical imaging inspired phantoms with moderate conductivity contrasts. The data were collected with the KIT4 and KIT5 EIT measurement devices at the University of Eastern Finland, and are intended for EIT image reconstruction algorithm development and testing. The data from thoracic imaging inspired cylindrical and chest-shaped phantoms are suitable for 2D algorithms, and the data from an intracerebral hemorrhage imaging inspired head-shaped phantom with resistive skull are suitable for 3D algorithms. In addition to the measurement data, computational meshes and example reconstruction codes are provided and sample reconstructions included.

0.34
12

Artifact Filtering versus Artifact-Compensated Training in JPEG to JPEG AI Recompression

eess.IV cs.MM ·2026-11-09 ·Igor Podtsepko, Yuriy Kim, Karam Mahfod, Evgeny Belyaev, Kristian Kirs +2 more
Abstract · Preprint. Submitted to IEEE Multimedia on 21 February 2026. This is the author's draft version; it has not undergone peer review. 15 pages, …

In this paper, we consider the problem of recompression of images from JPEG to JPEG AI format. We show that direct recompression from JPEG to JPEG~AI trained on uncompressed images is accompanied by the preservation of the JPEG image artifacts in the resulting JPEG~AI image. In order to avoid it, we evaluate an approach where an artifacts removal neural network is first applied to the input JPEG image as an external pre-filter. However, in this case, the processing time is increased by 29 times. Therefore, we propose an artifact-compensated training for JPEG AI and show that it is able to combine pre-filtering against target distortions with efficient compression without increase in the processing time.

0.33
13

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33
14

Automated PD-L1 Tumor Proportion Scoring with Uncertainty-Guided Triage in Non-Small Cell Lung Cancer

cs.CV eess.IV ·2026-11-12 ·Kesi Xu, Ayesha Azam, Tanvier Kaur, Monika Kondratowicz, Kinza Asim +5 more
hot direction
Abstract · 55 pages (29-page main text with 5 figures and 3 tables, followed by 26 pages of supplementary material)

Programmed death-ligand 1 (PD-L1) tumor proportion score (TPS) informs immunotherapy selection in non-small cell lung cancer. Near the 1% and 50% cutoffs, the score should also indicate when closer review is warranted. We designed a three-stage framework to follow the sequence of TPS assessment. Stage 1 identifies tumor regions and excludes macrophage-rich patches. Stage 2, a dual-branch cell counting network (D2Count-Net), counts PD-L1-positive and PD-L1-negative tumor cells in these regions to calculate TPS. Stage 3, TPS-Guard, an uncertainty-guided triage mechanism, reports model uncertainty as the disagreement among independently trained models, refers the most uncertain slides, and flags scores near the 1% or 50% cutoff when model estimates disagree across that cutoff. Flags state the reason for referral or alert the pathologist to possible scoring errors on auto-reported slides. In a retrospective, single-center study, 154 whole-slide images were scored by three pathologists, and the model and each pathologist were compared in turn with the mean of the other two. On the 114 slides unseen in training, model mean absolute error (MAE) was 6.96 percentage points, within the range of the three pathologists (4.24 to 8.29), and model uncertainty correlated with absolute TPS error (Spearman rho = 0.77) and inter-pathologist disagreement (rho = 0.71). After referral of the 15% most uncertain slides, model and pathologist MAE both decreased. Applied without retraining to an external, publicly available dataset, TPS-Guard still directed review to higher-error cases, and referring more uncertain cases raised sensitivity at the 50% cutoff. TPS-Guard provides reasons for reviewing individual automated scores and identifies slides that also produce greater disagreement among pathologists. Prospective reader studies should assess TPS-Guard's effect on TPS reporting.

0.31
15

Few-Shot Open-Set Hyperspectral Pixel-Wise Classification with Spatial Aware Label Propagation

eess.IV cs.NE ·2026-11-13 ·Matheus Pereira, Jefersson Santos, Laurent Najman
publishedbenchmarkhot direction
Abstract

Pixelwise classification of hyperspectral images (HSI) is a fundamental task in remote sensing, but its deployment in real-world applications is often limited by the scarcity of labeled data and the presence of unknown classes at inference time. In this work, we propose Few-shot Open-set hyperspectral recognition from Self-Supervised Learning training (FOSSeL), a unified framework for few-shot, open-set hyperspectral pixelwise classification that does not require supervised training. The proposed approach first leverages self-supervised learning to construct a discriminative feature space from unlabeled data. Then, given a small set of labeled seed pixels, class predictions are obtained through spatially-aware graph-based label propagation over superpixel representations, enabling the joint exploitation of spectral similarity and spatial consistency. To address the open-set scenario, we introduce simple yet effective strategies to identify pixels that do not belong to the known classes. We evaluate FOSSeL on three benchmark hyperspectral datasets under multiple few-shot settings. The results show that the proposed framework achieves competitive or superior performance compared to fully supervised methods while maintaining robustness in the presence of unknown classes. These findings highlight the potential of combining self-supervised feature learning with graph-based inference for practical HSI analysis in low-annotation and open-world scenarios.

0.31
16

Streaming across viewing conditions - The effect of viewing distance and display luminance on video quality

eess.IV cs.CVcs.MM ·2026-11-15 ·Dounia Hammou, Lukáš Krasula, Christos G. Bampis, Zhi Li, Rafał K. Mantiuk
unusual
Abstract

The visibility of streamed video distortions is affected by the user's display and viewing conditions, such as their display's luminance or the viewing distance. Distortions become less visible at lower luminance levels or farther viewing distances. However, most image and video quality metrics assume fixed optimal display and viewing conditions, making them insensitive to the viewing conditions. In this work, we demonstrate how existing metrics can be adapted to account for both factors and compare such an adaptation with the metrics that natively model viewing conditions. First, we collected a new video quality dataset, HDR-VDC, which contains streaming distortions in 4K HDR videos. The dataset consists of 12 4K and 4 FHD HDR source video content, each distorted with AV1 encoding and Lanczos upscaling from a lower resolution. The quality loss due to the distortions was measured at two viewing distances, corresponding to 60 and 120 pixels per visual degree, and two display mean luminance levels, varying by a factor of 8 in terms of luminance. Next, we developed a pre-processing framework that lets us adapt many quality metrics so that they can evaluate content across the viewing distances and luminance levels. The framework employs a display model and perceptually uniform encoding, PU21, to account for the effect of display luminance, and perspective projection scaling (PPS) to account for the effect of viewing distance. We used the framework to compare the performance of 35 state-of-the-art metrics. This allowed us to identify a selection of existing quality metrics that can be effectively adapted to account for the viewing conditions.

0.31
17

A four-step validation protocol for radiomic survival analysis in small cohorts: a body composition case study

eess.IV cs.CVcs.LG ·2026-11-09 ·Mariela Talavera-Muñoz, Cecilia Diana-Albelda, Miguel Antonio Sampedro-Nuñez, Victor Rodriguez-Laval, Jesus Bescos +1 more
code/data
Abstract

Gastroenteropancreatic neuroendocrine tumors (GEP-NET) lack prognostic biomarkers, and computed tomography (CT)-based body composition radiomics at the third lumbar vertebra (L3) is a promising candidate. Small cohorts make high-dimensional radiomic models prone to overfitting and single-split evaluations variable and optimistic. This methodological study proposes a four-step validation protocol for radiomic survival analysis in small cohorts: (1) false discovery rate (FDR)-corrected feature selection, (2) a dual-path comparison of prior feature selection versus embedded regularization, (3) repeated nested cross-validation (CV) and (4) a negative control with Gaussian noise features. In 78 GEP-NET patients, 535 radiomic features from five L3 compartments were used to evaluate five survival models with Harrell's concordance index (C-index), time-dependent area under the curve (AUC) and integrated Brier score (IBS). Step 1 selected at least one feature in 18% of outer folds under noise (nominal level 20%) versus 84% with radiomic features. The dual-path comparison showed no consistent difference between strategies. Repeated nested CV reduced variability across seeds (41% median reduction in C-index standard deviation), but not enough to distinguish models. The nested CV C-index exceeded chance by 0.07-0.15 with radiomic features but not clearly under noise (0.40-0.42 with prior feature selection, 0.47-0.55 with embedded regularization). Frequently selected features tentatively linked greater subcutaneous fat, skeletal muscle compactness and texture to better prognosis. These findings suggest a modest prognostic signal in L3 radiomics, with considerable uncertainty that the protocol quantifies. The protocol may transfer to other small-cohort radiomic survival studies. Code: https://github.com/marielatalaveram/radiomics-survival-validation-protocol.

0.30
18

Equal Dose, Different Coverage:Tracing Rate and Duration in Image Editing

eess.IV cs.AIcs.MM ·2026-11-15 ·Yi Liu
Abstract

Benchmarks for scientific image editing test whether a model draws the outcome of a described process, leaving open which representations carry its errors and whether correcting them yields the right quantity. We study this question with an airbrush of fixed deposition profile, under which exchanging rate and duration preserves the dose and should preserve the endpoint, yet changes the edited coverage. Matched-norm activation patches across text positions and denoising stages show that, in distilled FLUX with Chinese prompts, representations at unchanged text positions (context) carry this discrepancy: early context transfers 3.51 of the 3.98 percentage-point (pp) signed route difference, against 0.09 pp for equal-norm updates at the two changed digits. Early image latents transmit native (unpatched) route differences across two FLUX configurations and OmniGen, while text-position effects depend on configuration. The trace predicts an intervention: share early context between routes while each retains its own digits. On independent English layouts, this reduces the distilled-FLUX absolute route gap from 1.13 to 0.60 pp, outperforms early digit sharing, and improves agreement more than in base FLUX under directly paired tests. Calibrated evaluation, which prescribes an area for each dose, separates this gain from accuracy: sharing the full prompt encoding produces identical route images with target errors of 8-16 pp, and stating the target percentage directly retains a compressed area response. Localization predicts a consistency gain on new layouts, and calibration measures the quantity error that agreement leaves unresolved.

0.29
19

Probing Where Surprise Happens: Localized Violation-of-Expectation Evaluation of Video World Models

cs.CV cs.AIeess.IV ·2026-11-13 ·Yanbin Xu, Ming bo Cai
published
Abstract · 8 pages, 4 figures

Violation-of-expectation (VOE) benchmarks evaluate intuitive physics in video world models by testing whether physically impossible events produce greater prediction errors than matched possible events. However, conventional VOE evaluations aggregate prediction errors across space and time, making it unclear whether successful discrimination reflects model's understanding of physical violations at the locations and time where they occur. To address this limitation, we introduce localized VOE evaluation, a framework that measures prediction error differences between possible and impossible events within spatial regions and temporal intervals associated with physical violations. We compare global, temporally localized, and spatiotemporally localized evaluations of V-JEPA models pretrained on developmental egocentric videos or large-scale natural video datasets. Our results reveal that global and localized judgments can diverge in both directions: global aggregation can either obscure correct localized discrimination or produce apparent discrimination without corresponding localized evidence. During continued pretraining on developmental egocentric videos, agreement between global and localized judgments changes non-monotonically, while confidence in localized judgments increases despite modest improvements in accuracy. Together, these findings establish localized VOE evaluation as a complementary diagnostic for assessing intuitive physics in video world models and demonstrate that global prediction errors do not necessarily reflect the spatiotemporal evidence of physical violations.

0.27
20

Sequential Semantic-Non-Semantic Watermarking: Robustness Against UnMarker Attacks

cs.CR cs.CVcs.MMeess.IV ·2026-11-15 ·Md Ifraham Iqbal
Abstract · 13 pages, 16 figures. Preprint based on M.Sc. thesis research

Advancements in artificial intelligence (AI) have accelerated digital content generation and intensified concerns around fraud, misuse, counterfeiting, and content provenance. Defensive image watermarking provides a practical mechanism for identifying and tracing digital content, but recent watermark-removal attacks challenge its robustness. This study investigates Sequential Semantic Non-Semantic Watermarking (SSNSW), which combines HiDDeN and StegaStamp as complementary non-semantic and semantic watermarking schemes. Using 50 images from MS-COCO and CelebA-HQ, both embedding orders are evaluated, followed by UnMarker's non-semantic and semantic attacks applied individually and sequentially. Results show that both watermarks remain highly decodable after dual embedding, with only limited embedding-order effects. Under individual attacks, one watermark generally remains strongly decodable: StegaStamp under the non-semantic attack and HiDDeN under the semantic attack. Sequential attacks are therefore required to substantially reduce both watermark signals, while attack order has a limited and configuration-dependent effect. The semantic attack also shows a broader effect across the two watermark types than the non-semantic attack. LPIPS remains relatively low in several settings, although qualitative inspection reveals noticeable distortions, particularly in selected facial images, indicating that LPIPS should not be used alone to assess visual quality. Overall, the findings show that combining complementary watermark types can increase robustness against single-stage removal attacks and motivate broader multi-layer watermarking, stronger perceptual evaluation, and further study of sequential watermark-removal strategies.

0.27
21

Counterfactual Analysis of Extent Leakage from Annotation-Derived Prompts in Vision-Language Medical Image Segmentation

eess.IV cs.CVcs.LG ·2026-11-10 ·Niran Nataraj, Ankita Das, C. Krishna Mohan, Kenji Kawashima
benchmark
Abstract · 23 pages, 10 figures, 13 tables

Text-guided segmentation models receive an image and a short caption about the lesion, and on public benchmarks the caption improves accuracy considerably. On colonoscopy and breast ultrasound, however, the size, count and location words of each caption were computed from the mask that later scores the prediction, and the chest X-ray captions were written by benchmark annotators. We tested what two published models take from them. On colonoscopy and chest X-ray, it is mostly the lesion's extent. Keeping only the size word or the lung-zone phrase recovers 84 to 98 percent of the improvement over an empty caption, and removing it loses 52 to 77 percent. The rest matters little, and a polyp called a rock is segmented just as well. We call this extent leakage. On breast ultrasound, nearly half the captions also name the diagnosis, which carries part of the benefit. Retraining on three datasets shows that models pick up this habit from their training captions, though only partly on breast ultrasound, and that it weakens their segmentation from the image alone. The leak can be measured without training a model, since caption words alone predict lesion area (coefficient of determination 0.54 to 0.77 on six of seven test sets). Without the test mask, the best method we tested, which estimates extent from the image, reaches 74.59 Dice on colonoscopy against the published 77.23. We propose an evaluation protocol that keeps what a caption says about the image apart from what it copies from the label.

0.27
22

Transmission-Mode Multispectral Imaging for Estimation of Microcystis spp. Cell Concentration and ELISA-Equivalent Microcystin Concentration in Water

eess.IV eess.SP ·2026-11-12 ·J. A. S. T. Jayakody, G. Thilakarathne, G. A. S. L. Ranasinghe, M. C. L. De Silva, K. A. D. S. A. Perera +5 more
unusual
Abstract · 30 pages, 9 figures, 2 tables. Includes Supplementary Information

Harmful algal blooms dominated by Microcystis spp. threaten freshwater systems through proliferation and microcystin (MC) production. Conventional measurements of cyanobacterial abundance and MC concentration commonly require laboratory processing, specialized instrumentation, or assay reagents. Because MC concentration cannot always be reliably inferred from cell abundance, complementary optical approaches for estimating both quantities are of interest. This study proposes and evaluates a transmission mode multispectral imaging (MSI) framework for estimating Microcystis spp. cell concentration and ELISA-equivalent MC concentration from culture derived dilution samples. A custom built MSI system acquiring twelve spectral bands from near-ultraviolet to near-infrared wavelengths measured transmitted light spectral responses. Following principal component analysis based dimensionality reduction, spectral variation was quantified using an aggregated Wasserstein distance descriptor for regression based prediction. Cell concentration estimation yielded $R^2=0.9819$ for calibration and $R^2=0.9754$ on held-out intermediate dilution levels, while ELISA-equivalent MC estimation yielded $R^2=0.9788$ for calibration and $R^2=0.9786$ on held-out intermediate dilution levels. These results demonstrate the feasibility of transmission-mode MSI as a dual output optical calibration framework for estimation of Microcystis spp. cell concentration and ELISA-equivalent MC concentration in water.

0.27
23

SNIF: a Self-Navigator Intelligent Filter correcting off-center and spin-history artifacts in quasi-random radial MRI

eess.IV ·2026-11-09 ·Tanguy Boucneau, Brice Fernandez, Peder Larson, Luc Darrasse, Xavier Ma{î}tre
unusual
Abstract · 10 pages, 6 figures; supplementary material (93 pages): DC-signal spectra for every reception channel

For self-navigation and self-gating in MRI, self-navigators are extracted from the complex values of the k-space center, called DC-signal, through a temporal frequency analysis. However, this signal often carries artifacts. This paper introduces a Self-Navigator Intelligent Filter (SNIF) that models the physical origin of the k-space center artifacts to properly estimate them and thus more accurately remove them. The artifact affecting the DC-signal $S_{DC}$ generally has two main origins: the jitter of the k-space center (''off-center artifact'') and the cumulative history of the spins (''spin-history artifact''). Both add noise-like artifacts to the signal. The off-center effect can be modeled as a perturbative signal $S_0$ and the spin-history effect as a convolution kernel $h$ so that the measured DC-signal is $S_{DC} = S_m + S_0 \star h$, where $S_m$ is the motion-related component which effectively contains the expected self-navigators. Methods to compute $h$ and $S_0$ were developed, which gives the possibility to extract $S_m$ from $S_{DC}$. They were implemented and evaluated on thoracic UTE datasets acquired on a healthy volunteer. Qualitative visual comparison and quantitative spectral analysis of the DC-signal before and after SNIF demonstrate that the method improves both the accuracy and the precision of the extracted respiratory and cardiac self-navigators. By considering the physical origin of the DC-signal artifacts, SNIF makes both respiratory and cardiac self-navigators more sensitive to motion, which supports finer MRI motion tracking.

0.27
24

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27
25

Hybrid quantum learning for imbalanced blood-cell classification: domain adaptation and classifier design

eess.IV cs.LG ·2026-11-11 ·Gabriele D'Angeli, Cyrill Aebischer, Eryk Schiller, Gianluca Nicchiotti, Su Fong Chien +2 more
benchmark
Abstract · Submitted to Quantum Machine Intelligence

Limited annotated data, class imbalance, and morphological similarity make white blood cell classification challenging. We benchmark hybrid variational quantum classifier heads against an affine baseline on 821 microscopy images across seven morphological classes. Using ImageNet-initialised ResNet34 backbones and repeated stratified five-fold cross-validation, we first compare direct transfer with intermediate adaptation on MLL23, a larger peripheral blood cell microscopy dataset. To guide the head comparison, we explore different encoding strategies, variational depth, and the number of independent circuit blocks. We then compare the classifier performance using the affine head and two hybrid heads across multiple random seeds, under a shared training and evaluation protocol. For this comparison, all backbones share the same MLL23-adapted initialisation. Intermediate adaptation increases mean macro-F1 across all four affine-head fine-tuning configurations. The largest gain occurs with a frozen backbone, where macro-F1 rises from $0.685$ to $0.786$, a relative improvement of approximately $14.7\%$. The shallow two-block hybrid head achieves a mean pooled out-of-fold macro-F1 of $0.865 \pm 0.010$, compared with $0.879 \pm 0.008$ for the affine head. The corresponding balanced accuracies are $0.886 \pm 0.008$ and $0.889 \pm 0.010$, respectively. In the architectural exploration, the two-block hybrid head achieves the highest macro-F1 and balanced accuracy among the evaluated hybrid configurations, while the effect of encoding varies across the considered metrics. Our results help guide the design and evaluation of hybrid classifier heads for imbalanced microscopy by linking architectural choices to overall performance and class-specific precision-recall trade-offs.

0.26
26

Information about Optic Nerve Head Biomechanics is Already Coded in Your Clinical Charts and Can be Used to Predict Glaucoma Progression

eess.IV ·2026-11-11 ·Yibo Chen, Patipol Tiyajamorn, Charis Y. N. Chiang, Deepta Ghate, Thanadet Chuangsuwanich +1 more
unusual
Abstract · 43 pages, 6 figures, 1 table

Glaucoma patients routinely undergo optical coherence tomography (OCT) imaging and intraocular pressure (IOP) assessment as part of standard care. Because IOP typically differs across visits, it is possible to map visit-to-visit ONH strains by registering OCT volumes acquired under different IOPs. These strains reflect ONH elasticity and, over longer intervals, also capture growth and remodeling of the ONH. In this study, we evaluated whether such visit-to-visit ONH strain signatures could serve as predictors of glaucoma progression. We retrospectively analyzed 525 eyes from 430 glaucoma patients (238 fast and 287 slow progressors), defining fast progression by a visual field index slope of -1.5% per year or worse. 3D strain maps were derived from baseline and follow-up OCT scans using AI. Predictions using T=1 to T=4 follow-up visits were evaluated by five-fold cross-validation in a long-term cohort (T=1: 1.30 years; T=4: 5.26 years) and short-term testing (T=1: 0.46 years; T=4: 1.25 years). Overall, IOP differed between paired visits in 92% of cases. Long-term T=1 prediction achieved an area under the receiver operating characteristic curve (AUC) of 0.74 and accuracy of 0.72. A single short-term follow-up (T=1) yielded an AUC of 0.75 and accuracy of 0.71; four follow-ups yielded an AUC of 0.87 and accuracy of 0.82. SHapley Additive exPlanations (SHAP) identified neuroretinal rim compression and prelaminar elongation associated with fast progression, with substantial inter-eye variability. Overall, visit-to-visit ONH strains derived from routine OCT predicted glaucoma progression after a single follow-up visit at a mean interval of 0.46 years. These findings suggest that short-term OCT/IOP assessments could provide valuable insights into ONH biomechanics, identify eyes at risk of rapid progression, and reveal distinct strain signatures associated with disease progression.

0.26
27

Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid Cancer

eess.IV cs.CVphysics.med-ph ·2026-11-09 ·Boyang Pan, Hang Yang, Jianchen Pan, Cui Gan, Lanxi Zhang +2 more
Abstract · 12 pages, 2 figures, 3 tables

Background: Diagnostic I-131 whole-body planar imaging in differentiated thyroid cancer (DTC) is count-limited by low administered activity, and quality worsens under rapid acquisition. Models trained on such data struggle because their targets lack photon statistics. Purpose: To test whether high-quality post-therapeutic (PT) I-131 scans can serve as superior training references for enhancing sparse diagnostic planar images, using transfer learning and input-image addition. Methods: In this single-center prospective study, 111 patients were enrolled in PT training (n = 19), diagnostic follow-up (FU) training (n = 58), and FU paired test (n = 34) cohorts. Five Restormer-based models were trained: FU_DLx2 on FU labels; PT_DLx2 transfer-learned on PT data; PT_DLx1+ and PT_DLx2+ with input-image addition; PT_DLx6 as a PT-only reference. Test-time processing used two-step denormalization and Poisson re-scaling to preserve noise statistics. Quality was assessed by PSNR, SSIM, and a blinded dual-reader evaluation of all 34 test-cohort patients. Results: PT_DLx2 achieved the highest PSNR (34.4 +/- 3.6 dB) and SSIM (0.81 +/- 0.07). PT_DLx1+ and PT_DLx2+ were comparable (33.8 and 33.3 dB; SSIM 0.80). FU_DLx2 ranked below the unprocessed fast scan (30.3 vs. 32.0 dB; 0.76 vs. 0.79). Subjectively, PT_DLx2+ scored highest in image quality (4.54 +/- 0.60) and diagnostic confidence (4.54 +/- 0.60), surpassing the reference standard (4.19 +/- 0.83 and 4.31 +/- 0.81; P = 0.005 and P = 0.008). FU_DLx2 and PT_DLx6 scored lowest. Conclusion: Count-rich PT scans provide effective training priors for reconstructing extremely sparse images. Input-image addition and cross-domain transfer learning from PT data outperformed direct training on count-limited diagnostic data, supporting 2x scan acceleration with quality matching or exceeding the unaccelerated standard scan for selected PT-derived configurations.

0.26
28

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

eess.IV cs.AIcs.CVcs.RO ·2026-11-10 ·Niran Nataraj, Maina Sogabe, Masamichi Yamashita, Norihiko Ito, Kenji Kawashima
Abstract · 20 pages, 10 figures, 11 tables

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

0.26
29

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26
30

Real Pairs Are Not Enough: Physically Anchored Supervision for Volumetric CT Super-Resolution

cs.CV eess.IV ·2026-11-11 ·Haoran Liu, Zipei Yan, Mingzhe Liu, Jizhou Li, Guibin Zan
Abstract · 47 pages, 5 figures, including supplementary material

Volumetric CT super-resolution (SR) models are commonly trained on synthetic or physically acquired pairs of low-resolution (LR) and high-resolution (HR) volumes. However, synthetic pairs miss real acquisition effects, whereas registered physical pairs retain inter-scan noise, artifact, and microstructure differences---causing direct voxelwise regression, and even naive synthetic-real mixing, to oversmooth fine porous structures. We introduce the Physically-anchored Implicit Network (PIN) with Real-Pair Dual-Anchor learning, which decouples physical-pair supervision into two complementary roles. The HR anchor teaches fine structure from registered HR through pair-conditioned spectral replay, while the LR anchor constrains the prediction from acquired LR via affine-calibrated low-pass projection. Together with exact synthetic supervision in one shared volumetric implicit model, PIN learns from both physical scans without forcing the acquired-LR reconstruction to match registered HR voxel by voxel. Inference requires only acquired LR. Across 30 external baseline configurations on real CT, PIN achieves the lowest full-volume LPIPS, reduces average symmetric surface distance by 42.3-49.5% and bone-volume-fraction error by 52.2-53.4% relative to the three strongest baselines for each metric, and lowers the erased reference-pore volume fraction from 37.3-72.9% to 10.4%. Code, pretrained models, and evaluation scripts will be publicly available.

0.26
31

TuMAP: A Dual-View, Morphotype-Aware Pathomics Pipeline for Quantifying Renal Tubular Remodeling

cs.CV eess.IV ·2026-11-12 ·Ruijie Wu, Yuechen Yang, Yanfan Zhu, Yu Wang, Shilin Zhao +6 more
Abstract · 5 pages, 3 figures, 1 table. Submitted to IEEE ISBI 2027

Quantifying disease-associated renal tubular remodeling is challenging because tubular appearances are heterogeneous. We introduce TuMAP (Tubular Morphotype-Aware Pathomics), a pipeline combining (1) dual-view foundation-model representations and provisional morphotype annotation, (2) compositional and within-morphotype pathomics, and (3) patient-level statistical inference. From 456,158 tubules in 358 PAS-stained kidney biopsy slides, TuMAP identified eight image-based morphotypes, seven of which showed stable subsampling assignments. Across 219 patients in six diagnostic groups, diabetic nephropathy (DN) and tubulointerstitial nephritis/acute tubular injury (TIN/ATI) each differed from minimal change disease in seven morphotype proportions, while IgA nephropathy differed in six. DN showed reduced nuclear solidity and increased eccentricity across all eight morphotypes. Area-normalized nuclear density exposed additional within-morphotype differences. TuMAP provides a framework for separating changes in tubular morphotype composition from phenotypic differences within morphotypes.

0.26
32

Interpreting Selective-Review Coverage for Head-and-Neck Auto-Contours

eess.IV ·2026-11-11 ·Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu
unusual
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

Selective-review systems aim to reduce human review by passing candidates predicted to be low risk. However, coverage (the fraction passed) can be misleading when measurements needed to interpret risk are unavailable. We separate structural evaluability (a nonempty mask with all required measurements available), computational-endpoint status, and pass-or-review decisions using archived Mayo records and controlled OpenKBP analyses. In 3,968 Mayo records, all 1,167 recorded empty predictions (predicted target-organ masks containing zero voxels despite nonempty reference masks) were endpoint-negative and passed both modules, accounting for approximately 76% of each pass set. In a held-out OpenKBP test, a logistic-regression router achieved an area under the receiver operating characteristic curve of 0.833 and average precision of 0.449 but passed all 544 non-evaluable candidates, including 542 prespecified empty-mask controls and 2 erosions that became empty. A structural gate removed those passes without changing scores or the threshold, preserved all evaluable passes, and assigned 98.71% of endpoint-positive candidates to review. Under the original preprocessing and in patient-disjoint development evaluation, a router trained only on evaluable candidates and a router modeling an unavailable state likewise passed no non-evaluable candidates, with similar evaluable discrimination and at least 99.0% of endpoint-positive candidates assigned to review in pooled outer-fold predictions. These results show that coverage should be interpreted jointly with candidate eligibility, endpoint scope, missingness handling, and routing rules; they do not establish clinical validity, deployment safety, or natural-failure prevalence.

0.25
33

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.24
34

X-Strata: Separating Aneurysms and Overlapping Vessels into Layers from 2D X-ray Angiography

eess.IV cs.CV ·2026-11-13 ·Zhihong Wen, Congzhou Chen, Hucheng Li, Xun Han, Jianning Zhang +7 more
Abstract · 22 pages, including 10 pages of supplementary material

An X-ray angiogram sums every structure along a ray into one pixel. When vessels cross an aneurysm, they obscure part of it and mix their contrast into its filling curve. We present X-Strata, a network that separates a cine angiogram into three layers: the complete aneurysm sac, the vessels in front of it, and the vessels behind it. Contrast timing indicates how much each layer contributes to a pixel, and parallax between two views indicates their order, which a single view cannot determine. X-Strata first estimates the layers and their contrast curves, then uses the second view to assign vessels to the front or back layer, and lifts all layers into 3D. It learns from layer labels projected from same-session 3D rotational angiography, but needs only 2D cine runs and their acquisition geometry at inference. On 220 held-out patients from three centers (122 external), two-view X-Strata ranks first among 14 baselines, including VGGT and C$^2$RV, in recovering the sac where vessels overlap it (Dice 0.693 internal, 0.641 external) and in ordering the layers (balanced accuracy 0.703, 0.659). Its order accuracy exceeds that of all 11 end-to-end baselines by at least 4.1 points internally and 3.3 externally (Holm-adjusted $p < 0.001$) and grows with view separation. Recovered 3D sac surfaces have a median Chamfer distance of 0.34 mm on the internal cohort. X-Strata may therefore provide layered aneurysm and vessel information, including 3D sac shape, for patients who undergo only 2D angiography.

0.24
35

Ref-MIL: Plug-and-Play Posterior Refinement for Multiple Instance Learning in QSM-Based Brain Disease Classification

cs.CV eess.IV ·2026-11-14 ·Ang Gaoa, Rui Jina, Yin Liu, Pengfei Rong, Feng Liu +3 more
Abstract · 5figure, 6tables;

Quantitative susceptibility mapping (QSM) is a novel quantitative MRI contrast for studying tissue susceptibility changes in brain disorders, including Parkinson's disease (PD) and multiple sclerosis (MS). However, small cohorts and the lack of local annotations make developing deep learning models for QSM-based diagnosis challenging. In this work, we propose PoRef-MIL, a weakly supervised multiple instance learning (MIL) framework combining iterative slice relabeling and network retraining with a plug-and-play posterior refinement module (PRM). During training, a 2D dual-branch diagnosis network and a subject-level classifier were alternately trained for five rounds. The classifier was used to update slice pseudo-labels for retraining the diagnosis network. The PRM was applied during inference to refine slice probabilities through bidirectional posterior inference and calculate entropy-derived confidence from the refined probabilities, which was then used in sliding-window scoring to obtain subject-level predictions. PoRef-MIL was evaluated on an in-house PD cohort of 287 participants and a public MS cohort of 150 participants. Compared with eight classification methods, PoRef-MIL achieved the highest mean areas under the receiver operating characteristic curve of 0.942 and 0.872, and accuracies of 0.926 and 0.833, for PD and MS classification, respectively. Ablation experiments were conducted to validate the effectiveness of iterative relabeling and PRM, and the plug-and-play feature of the proposed PRM was also evaluated using four state-of-the-art MIL models. Overall, PoRef-MIL offers a promising approach to QSM-based disease classification in small cohorts without manual slice annotations.

0.23
36

Joint Activation and Weight Quantization for Learned Image Compression

eess.IV cs.MM ·2026-11-10 ·Yile Tu, Heming Sun
published
Abstract · Accepted at IEEE VCIP 2026. 5 pages, 3 figures

Learned image compression (LIC) models achieve competitive rate-distortion performance with increasingly large networks, making network quantization important for efficient deployment. Directly quantizing LIC models remains difficult in post-training quantization (PTQ) because compression performance is highly sensitive to quantization noise. Existing methods typically focus on optimizing either the weights or the activations, resulting in substantial rate-distortion degradation. To address this limitation, we introduce a two-stage pipeline that uses SmoothQuant to balance activation and weight ranges, followed by GPTQ to adapt the transformed weights. The proposed joint search framework optimizes the balancing transformation and adapted weights under the rate-distortion objective, accounting for the coupling between the two stages. Experiments across multiple LIC architectures and activation quantization configurations show that the joint search strategy consistently reduces rate-distortion degradation after quantization.

0.23
37

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22
38

Supervision-Aware Evaluation of MedGemma for Reference-Assisted Radiotherapy Contour Ranking

eess.IV cs.CVcs.LG ·2026-11-11 ·Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu
Abstract · 5 pages, 1 figure, 3 tables. Submitted to IEEE ISBI 2027

Radiotherapy contour ranking can support quality assurance, but vision-language model (VLM) gains may reflect supervision, score construction, available inputs, or representation access. We evaluated frozen MedGemma 1.5 in a single-institution study, a 12-patient held-out HaN-Seg test, five-fold cross-fitting on 30 non-test HaN-Seg patients, and transfer without refitting to 120 SegRap2023 patients. On held-out HaN-Seg, a supervised readout of the final prompt state exceeded a supervised readout of the model's yes/no output probabilities by +0.3047 pooled average precision (AP; 95% patient-bootstrap interval [+0.2822, +0.3269]); the advantage persisted against a parameter-count-matched nonlinear control. A readout of projected visual tokens exceeded the final-state readout in cross-fitting and transfer (+0.0706 AP averaged equally across patients on SegRap; 95% interval [+0.0607, +0.0804]), while a structured panel-feature readout remained competitive with visual tokens. The anatomy-conditioned readout did not demonstrate an advantage over the native-feature comparator. These results motivate visual-token and structured-feature controls in medical-imaging VLM evaluations; outcomes were computational or synthetic, not clinical acceptability.

0.22
39

PiLLVD: A Real-World Low-Light Video Dataset for Dynamic Scenes Captured with Off-the-Shelf Cameras

cs.CV eess.IV ·2026-11-12 ·Yaser Abu Awwad, Paul L. Rosin, Oktay Karakuş
benchmarkdataset
Abstract · 14 pages, 7 figures, 5 tables. Dataset available on Zenodo: https://doi.org/10.5281/zenodo.23015904

Low-light image and video enhancement has received increasing attention in recent years. However, most existing enhancement methods are developed and evaluated on still images, while progress in low-light video enhancement remains limited by the lack of real-world paired video datasets. Acquiring paired low-light and normal-light video sequences is challenging because it requires spatially and temporally aligned captures while avoiding motion blur, exposure mismatch, and correspondence errors in dynamic scenes. To address this gap, we introduce PiLLVD, the Pi-based Low-Light Video Dataset, a paired low-light video dataset captured using an accessible Raspberry Pi-based multi-camera system with off-the-shelf cameras. PiLLVD provides paired low-light and aligned normal-light reference sequences for dynamic indoor and outdoor scenes, including diverse human and object motion under varying illumination conditions. Unlike existing datasets that are often image-based, static, synthetic, or limited to simple motion patterns, PiLLVD focuses on motion-rich scenes where frame-to-frame stability and motion-related artefacts are important for evaluation. In addition to presenting the dataset and acquisition pipeline, we benchmark representative pre-trained low-light video enhancement methods on PiLLVD under a zero-shot setting. The results show that existing methods do not generalise uniformly across the proposed sequences, highlighting the challenges posed by the proposed dataset and its value for both benchmarking existing methods and supporting the development of future low-light video enhancement algorithms.

0.22
40

Accelerating Variational Cone-Beam CT Reconstruction with Learned Warm Starts

eess.IV cs.AIcs.CV ·2026-11-13 ·Héloïse Dudoignon, Clément Delmas, Laurent Facq, Clair Poignard, Baudouin Denis de Senneville
Abstract · Submitted to IEEE ISBI 2027

Variational reconstruction provides a rigorous framework for cone-beam computed tomography (CBCT) by combining an explicit acquisition model with image priors. However, iterative optimization remains computationally demanding, particularly under severe noise and sparse-view conditions. Although learning-based methods achieve high reconstruction quality, they often replace the original variational formulation with learned optimization schemes or nonlinear equilibrium models. We propose a neural network-guided warm-start framework that accelerates variational reconstruction while preserving its original formulation. Projection data are first reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm, and the resulting image is refined by an image-domain neural network. The network output is used solely to initialize the subsequent model-based optimization, leaving the forward model, data-fidelity term, regularization, and optimization scheme unchanged. A pre-regularization step further improves compatibility with the variational priors. Experiments on pelvic CT images from the SynthRAD2025 challenge show a more than threefold reduction in reconstruction time while maintaining comparable image quality.

0.21
41

BeST: Beta splatted tomography for direct reconstruction from coherent imaging measurements

eess.IV math-phphysics.data-an ·2026-11-13 ·Johannes Gruen, Philipp Paetzold, Andreas Schropp, Aknur Karabay, Shahin Sepanlou +10 more
Abstract

Conventional coherent X-ray tomography requires the phase of each projection to be reconstructed with high fidelity. However, individual reconstructed projections might be flawed, e.g. due to positioning errors, yielding inconsistent tomographic reconstructions. By directly coupling phase retrieval and tomography, consistency is enforced through a common object volume. But reconstructing a full volume demands substantial computational resources. To reduce this demand, we introduce Beta Splatted Tomography (BeST), which represents the common object volume using compactly supported beta primitives with closed-form analytical projections, enabling efficient reconstruction directly from coherent scattering images. This representation substantially reduces the number of optimizable parameters compared to a voxel grid. We demonstrate BeST on experimental datasets from hard X-ray near-field holography and far-field ptychography measurements. In both cases, the joint technique improves reconstruction quality compared to two-step methods.

0.21
42

Context-Predictive Low-Rank Adaptation for Face Presentation Attack Detection

cs.CV eess.IVeess.SPstat.ML ·2026-11-12 ·Aminu Yusuf, Shakeel Muhammad Ibrahim, Sulaimon Oyeniyi Adebayo, Muhammad Sohail Ibrahim, Muhammad Shahid Jabbar +1 more
benchmark
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Face presentation attack detection requires representations that distinguish physical spoofing cues across changes in acquisition devices, subjects, and attack media. Large visual encoders offer transferable representations, but conventional binary fine-tuning supervises their final decisions without explicitly constraining how local facial evidence is represented under partial observation. We present CP-JEPA, a context-predictive adaptation framework that combines low-rank tuning of a pretrained CLIP image encoder with a joint-embedding predictive objective. A student predicts complete-image teacher features at masked spatial locations, while unmasked classification, masked classification, and prediction consistency retain the connection to the live/spoof task. An exponential-moving-average teacher supplies evolving latent targets. The auxiliary components are used only during training; inference requires only the LoRA-adapted CLIP visual encoder and binary classifier. {We evaluate CP-JEPA under single-source and multi-source OCIM transfer, additional CelebA-Spoof training, transfer to CelebA-Spoof, two-source training, and unseen-attack evaluation on SiW-Mv2.} On the standard OCIM benchmark, CP-JEPA achieves 3.74\% mean HTER and 98.73\% mean AUC. {Single-source evaluation achieves 11.36\% mean HTER across twelve source--target combinations.} With CelebA-Spoof added to the three OCIM training sources, CP-JEPA reduces mean HTER from 3.45\% to 2.35\% and increases mean AUC from 98.68\% to 99.32\%. On SiW-Mv2, it achieves 3.36\% mean HTER across the held-out attack categories. Controlled loss ablations examine the contributions of latent prediction, masked classification, and prediction consistency. The results show that context-predictive adaptation can improve cross-dataset PAD performance, although the gains vary with the training sources and evaluation setting.

0.20
43

DiffusionSSD: Achieving Extreme Visual Compression with Dual-stage Diffusion and Cross-level Near-Data Processing

cs.AR cs.CVeess.IV ·2026-11-13 ·Kuai Yu, Wen Li, Shengwen Liang, Jie Zhang, Ying Wang +4 more
Abstract · 15 pages, 19 figures

Growing visual data overwhelms storage on resource-constrained edge devices, making compression essential. Traditional codecs offer inadequate rate-distortion performance, motivating the exploration of diffusion codecs. Diffusion codecs face two limitations: (1) At the algorithm level, diffusion decoders preserve perceptual quality under extreme compression, but require substantial computation. (2) At the architecture level, in NPU-centered devices, neural codecs occupy the NPU, interfering with other AI applications. Meanwhile, the complex codec pipeline incurs long I/O paths, leading to additional overhead and energy cost. To address these issues, we propose DiffusionSSD, a cross-level near-data processing framework for extreme visual data compression on edge devices, using an algorithm-architecture co-design method. Specifically, (1) at algorithm level, we present Dual-stage Diffusion, a lightweight solution tailored for diffusion codecs that employs patchification and single-step diffusion, reducing computation cost while preserving perceptual quality; (2) at architecture level, we introduce a Cross-level Near Data Processing architecture that integrates the proposed computational universal flash storage (cUFS) and LPDDR-PIM, enabling codecs to be entirely offloaded to data side while reducing visual-data movement and avoiding SoC redesign; (3) at system level, combining both the algorithm and the underlying architecture, we propose a Patch-Workload co-aware scheduling scheme to enable more efficient system-level execution. Experiments show that Dual-stage Diffusion maintains comparable perceptual quality while reducing computation cost by up to 92.7%. Compared with NPU+DRAM and near-data-processing design such as SmartSSD, cUFS+PIM improves coding throughput by 2.32 times and 2.91 times on average, respectively.

0.20
44

Learning Motion-Appearance Coupling Priors for Solving Video Inverse Problems

cs.CV cs.LGeess.IV ·2026-11-11 ·Anselm Krainovic, Reinhard Heckel
published
Abstract · NeurIPS 2026

Reconstructing video from degraded measurements requires priors that capture both frame appearance and temporal dynamics. Many recent approaches combine pretrained image diffusion priors with motion guidance, sidestepping the costs of training large video models. Temporal consistency is often enforced via photometric losses or warping-based constraints, which implicitly assume that motion explains frame-to-frame or latent-to-latent changes up to small deviations, an assumption that fails under occlusions, lighting changes, and non-rigid deformation. In this paper, we propose to learn the coupling between motion and frame appearance as a generative prior. We learn the distribution of motion-induced appearance residuals with a conditional diffusion model and use it to regularize reconstruction in video inverse problems. Our motion-appearance prior acts as a plug-in regularizer for diffusion-based video reconstruction, preserving the benefits of image diffusion models while remaining compatible with existing appearance regularization techniques. Experiments on dynamic video inverse problems show that reconstruction with a learnt motion-appearance coupling prior outperforms photometric-consistency and noise-warping baselines, and that the approach also transfers to cardiac MRI reconstruction.

0.20
45

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

eess.IV cs.CVcs.LGphysics.med-ph ·2026-11-12 ·Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers +4 more
Abstract · 51 pages, 4 tables, 8 figures

2D-to-3D image registration is a key component for several medical imaging purposes such as intraoperative guidance, enabling the alignment between preoperative 3D volumes and real-time 2D images. While conventional optimisation-based methods often struggle with non-convex objectives, sensitivity to initialisation, and high computational demands, deep learning (DL) has emerged as a promising alternative, offering improved alignment robustness and the potential for real-time performance. This review provides a comprehensive analysis of DL frameworks developed to address the challenges inherent in 2D-to-3D registration. We first outline how core concepts of DL are adapted to the registration problem. We then examine recent methodological advancements from multiple perspectives, including pipeline design, architectural innovations, and domain adaptation strategies. Particular attention is given to quantitative metrics, highlighting how performance is defined and measured across studies. Across the 41 included studies, we find that direct regression is the most common pipeline (23 studies, against 18 iterative ones), that hybrid CNN-attention architectures are gaining ground, and that research remains heavily concentrated on X-ray-to-CT registration. We conclude by identifying the absence of per-case uncertainty estimation and the strong neglect of temporal or sequential modelling as the two methodological gaps most consequential for clinical readiness, and discuss state-space models as a way to add temporal memory within intraoperative latency budgets. Further opportunities lie in more principled domain adaptation and in the integration of foundation models for representation learning.

0.19
46

D2ToF: One-Step Diffusion for Depth Super-Resolution from Lightweight Single-Photon LiDAR Waveforms

eess.IV cs.CV ·2026-11-13 ·Pallabjyoti Deka, Lewis Wilson, Stephen McLaughlin, Jonathan Leach, Abderrahim Halimi
Abstract

Single-photon LiDAR (SPL) sensors offer exceptional temporal resolution and single-photon sensitivity for depth imaging. However, cost-effective SPL arrays typically suffer from extremely low spatial resolutions (e.g. $8\times 8$ pixels), limiting their real-world utility. In this paper, we propose a novel, one-step super-resolution framework, D2ToF, Distilled Diffusion for Time-of-Flight, that bridges the gap between high-fidelity generative modeling and real-time execution. Our approach uses an amortized variational distillation strategy that allows for a measurement-based data consistency term to be incorporated directly into the one-step training objective. This encourages that the synthesized high-resolution depth maps are consistent with the captured low-resolution Time-of-Flight (ToF) histograms. To overcome the severe ill-posedness of upsampling extremely degraded inputs, we introduce a multimodal guidance strategy. By leveraging a foundational monocular depth model to extract structural priors from a high-resolution reflectivity image, our network is guided by a rich triad of the ToF histogram, reflectivity map, and relative depth estimate. Experimental results outperform evaluated baselines, achieving $16\times$ spatial super-resolution (from $8\times 8 \times 100$ histograms to $128\times 128$ depth maps) at an accelerated inference speed of approximately $83$ milliseconds.

0.19
47

XLSAR-Bench: Towards Extremely Large SAR Imagery Understanding of MLLMs

eess.IV cs.CV ·2026-11-14 ·La Jiang, Lingfeng Chen, Jiaqi Zhu, Fengrong Guo, Jiehua Zhang +3 more
benchmark
Abstract

The rapid development of multimodal large language models (MLLMs) has highlighted the need for comprehensive benchmarks to assess their capabilities and limitations in remote sensing (RS). However, evaluating MLLMs in large-size synthetic aperture radar (SAR) scenarios remains challenging, as understanding complete scenes requires both global semantic interpretation and fine-grained target perception. Existing SAR benchmarks predominantly rely on small image patches, limiting their ability to assess these capabilities jointly. To address these limitations, we present XLSAR-Bench, a comprehensive benchmark for evaluating the perception and reasoning capabilities of MLLMs in large-scene SAR imagery. XLSAR-Bench comprises 405 images with an average size of 7153$\times$7153 pixels, ten tasks spanning visual question answering, visual grounding, and detailed image captioning, with all evaluation samples meticulously annotated manually, assisted by a semi-automatic captioner. Experimental results from general-purpose and domain-specific MLLMs reveal persistent challenges in understanding large SAR scenes and accurately perceiving small targets. We have open-sourced XLSAR-Bench to support further research in developing more powerful MLLMs for complete large SAR scenes.

0.19
48

Midsagittal Corpus Callosum Parameterization: A Framework for Spatially Detailed Diffusion MR Imaging Analysis

eess.IV q-bio.NCq-bio.QM ·2026-11-14 ·Caio Santana, Catherine Lebel, Richard Frayne, Letícia Rittner
Abstract · 47 pages, 10 figures, 6 tables, plus 11 pages of supplementary material (12 figures, 6 tables). Under review at Imaging Neuroscience

The corpus callosum (CC) is the largest white matter structure in the human brain and plays a central role in interhemispheric communication. Diffusion MR imaging is widely used to investigate microstructural organization, but commonly used analysis approaches have important limitations. Voxel-based methods rely heavily on accurate inter-subject registration and smoothing choices, tract-based spatial statistics (TBSS) restricts the analysis to a narrow white matter skeleton, and parcellation approaches reduce spatial detail by averaging diffusion measures over relatively large regions. In this work, we introduce a parameterization framework for the analysis of the midsagittal CC that resamples the structure using a standardized grid of points, establishing a geometric correspondence across individuals without explicit inter-subject registration. In a test-retest dataset, the method provided stable measurements while covering most of the midsagittal CC, and sensitivity analyses showed that results in the central CC changed little under perturbations of the input CC mask, whereas peripheral regions were more sensitive. The framework was further evaluated in group analyses of aging and Alzheimer's disease in datasets that differ in acquisition protocol and spatial resolution. Effect-size maps and quantitative comparisons showed that its results were largely consistent with TBSS and parcellation-based analyses in the overall spatial pattern of effects, while also revealing additional spatially localized differences. These findings suggest that the parameterization provides a simple, computationally efficient, and spatially detailed approach for investigating midsagittal CC microstructure, offering a structure-specific complement to whole-brain and region-based methods.

0.18
49

Zero-shot diffusion image compression with sectioned codebooks and one channel code

eess.IV cs.ITeess.SP ·2026-11-14 ·Dinanath Padhya
Abstract · 14 pages, 6 figures, 7 tables

Zero-shot diffusion codecs such as Turbo-DDCM compress images without any training. In each coded step, the encoder selects noise vectors from one codebook and transmits a single index for the selected set. We propose sectioned codebooks. A coded step is divided into sections, and each section has its own large codebook and transmits its best vector as a short field of bits. A model based on order statistics quantifies how well the bits of a step are used and predicts the gain of sectioned codebooks from measurements of Turbo-DDCM alone. Fast Walsh-Hadamard transforms make sections of $2^{20}$ vectors practical. At equal bits, sectioned codebooks improve the PSNR of Turbo-DDCM by 0.18 to 0.51 dB on three datasets, improve LPIPS and DISTS, and save 16 to 21% of the bits at equal PSNR. Codecs that are robust to channel errors by design are usually compared only with unprotected codecs. We compare them, at equal total bits, with a codec protected by one channel code. With one BCH code, the sectioned codec outperforms all reported results of Robust Turbo-DDCM and BitFlat on two datasets, by up to 7.74 dB at the highest bit error rate. At the lowest bit error rate its margin over BitFlat is only 0.08 to 0.16 dB. When the code fails, the receiver can still decode the fields as received. Additional experiments cover burst errors and packet loss, and all observed gains of robust codecs stay within a limit derived from the channel capacity.

0.17
50

Machine Learning for Near Real-Time Identification of Wildfire Burned Areas

cs.LG cs.CVeess.IV ·2026-11-15 ·Khoi Nguyen, Adam W. Bargteil, Milton Halem
Abstract

In this article, we present a near real-time method that estimates burned probability anywhere in the world using satellite images. Our approach takes advantage of the state-of-the-art pix2pix model to translate a preprocessed index calculated from Landsat 8/9 images into an approximate of USGS Burn Probability indicating per pixel burn probability. Since this is a machine learning-based approach, it can be automated with a minimum amount of human intervention with significantly less time delays and geographic restrictions compared to other contemporary methods. We include results from our experiments and compare our approximation with the USGS Burn Probability using RMSE score.

0.17