CS Paper Radar

Weekly top 50 · eess.IV

2026-W47 Nov 16 – Nov 22, 2026

Ranked from 3,882 papers submitted on 5 days — week in progress, ranks can still change.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Passing NPCR Without Diffusion: Exact Signatures, a Detection Benchmark and an Audit of Published Image Ciphers

cs.CR cs.MMeess.IV ·2026-11-19 ·Mua'ad Alfarajat
publishedbenchmarkunusual
Abstract · Accepted for publication in the Journal of Information Security and Applications. This is the submitted version; the accepted manuscript wil…

NPCR, the share of ciphertext bytes changed by a one-pixel plaintext change, is reported for nearly every image cipher as evidence of diffusion, with 99.61% the target. Several mechanisms produce values near it, and the mean does not say which. We separate three regimes: no propagation, one round of forward and backward chaining linear over addition or XOR, and independent ciphertexts. For the second an exact count applies. After a least-significant-bit change its mean asymptotically matches the independent-ciphertext reference, while its spread without cancellation is about five to twenty times larger. In simulation, the one-sided NPCR test of Wu, Noonan and Agaian flags one-round additive, mixed and S-box chaining in 2-4% of papers; read in both directions, the same five values flag at least 99.9%. Two-sided testing does the detecting; the spread and the other signatures help diagnose the structure. We then audit twenty-one published schemes. The count matches a reimplementation of one published diffusion layer on every trial and accounts for its reported table, the signatures show two schemes whose printed specifications cannot produce their reported values, and find that three of our own report plain-versus-cipher values and fall to two chosen images; ten more change their encryption material with the plaintext or per encryption, so their NPCR mostly reflects that change. A released checker applies the signatures to published tables, showing what a table measures within stated assumptions; it does not certify security.

0.64
2

Breaking Noise Shortcuts in Self-Supervised Learning Via Noise-Aligned View Generation

eess.IV cs.AIcs.CV ·2026-11-19 ·Oankar R. Patil, May D. Wang
publishedcode/data
Abstract · 40th Conference on Neural Information Processing Systems (NeurIPS 2026)

Self-supervised learning (SSL) is increasingly applied to scientific imaging domains, such as microscopy, where labels are scarce but noisy data is abundant. These domains exhibit significant signal-dependent noise, which can create a representational shortcut: since both augmented views derive from the same noisy image, the encoder can boost view agreement by also encoding noise patterns rather than semantic content. To enable noise-robust representation learning without knowledge of underlying noise models, we introduce Self-Aligned Noise Augmentation (SEANA), a drop-in module that generates noise-aware SSL views. SEANA learns an invertible variance-stabilizing transform (VST) from noisy data, then estimates the clean signal and resamples independent noise in learned VST space, requiring no clean targets, no dataset-specific denoiser training or use at inference, and no changes to the SSL objective or encoder. On CIFAR-10 and ImageNet-100 under synthetic Gaussian, Poisson-Gaussian, and multiplicative noise, SEANA improves clean-test linear-probe accuracy across contrastive/non-contrastive SSL methods, indicating higher-quality representations. On real fluorescence imaging, SEANA improves Jurkat cell-cycle stage classification by up to 28.6pp over standard SSL and 27.5pp over denoiser-preprocessed baselines. In all settings, SEANA outperforms the denoiser-preprocessed SSL pipelines, demonstrating that learned VST-space noise-aligned resampling yields more robust representations than denoising alone. Code is available at: https://github.com/opatil31/SEANA

0.55
3

Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

eess.IV cs.LGphysics.med-ph ·2026-11-19 ·Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack +2 more
top venuecode/data
Abstract · 13 pages (incl. cover page), 6 figures, 2 tables. Accepted version of the article published in IEEE Transactions on Biomedical Engineering. …

Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.

0.51
4

Pathology Randomization for Synthetic Priors and Zero-Shot Detection

cs.CV cs.AIeess.IV ·2026-11-16 ·Alexandra G. Roberts, Tonmoy Hossain, Mark Olchanyi, Stefan Brandstätter, Jonathan Williams Ramirez +5 more
benchmarkcode/data
Abstract · 25 pages, 9 figures, 13 tables (8-page main text with appendices). Code: https://github.com/agr78/Pathology-Randomizer

Hospital brain imaging archives hold a diverse array of pathology at sample sizes beyond prospective studies, particularly for underrepresented populations and diseases. To unlock uncurated clinical data and scale analysis, methods are needed to detect abnormalities across contrasts and resolutions. Synthetic data has provided robust, contrast-agnostic models for a variety of human neuroimaging tasks in healthy anatomy, but pathology detection and other tasks in clinical settings still require real patient data, contrast-specific models, or disease-specific generators. We propose PathoDraw, a generative model of brain MRI with pathology. A conditional distribution of lesions given the healthy anatomy is drawn into the label map before contrast-agnostic rendering, and a single network estimates healthy anatomy with exact signed intensity deviation of any input scan. The contrast-agnostic 3D UNet learns the healthy labels under the lesion and the signed deviation directly and identifies pathology via robust tissue statistics and learned features, despite no training on real pathology. We show zero-shot detection on public stroke, tumor, and white matter hyperintensity datasets as well as archived clinical data, spanning $T_1$w, FLAIR and $T_2$w at various resolutions under a recent unsupervised anomaly detection benchmark protocol. Our single model exceeds or performs comparably to contrast-specific anomaly detectors trained on real scans and keeps healthy anatomy intact. The same generator trains networks for super-resolution and for registration in the presence of pathology. Our model, robust across acquisition and disease, enables the use of uncurated, archived data for clinical analysis. Our code is available at https://github.com/agr78/Pathology-Randomizer.

0.48
5

LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising

eess.IV ·2026-11-19 ·Fatma Elif Yalçındağ, Mehmet Ozan Ünal, Metin Ertaş, İsa Yıldırım
code/data
Abstract · 5 pages, 3 figures, 2 tables. Submitted to IEEE ISBI 2027. Code: https://github.com/itu-biai/lbw-nps

Low-dose CT denoising should suppress noise while retaining the local texture of the reference image. Matching a pooled spectrum can overlook regional discrepancies, whereas pixel losses alone can favor overly smooth outputs. We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning. Each valid patch contributes a weighted squared log-energy difference across three frequency bands, alongside an $L_1$ reconstruction term. We compare LBW-NPS against $L_1$-only training and five auxiliary-loss baselines using the same U-Net and three seeds on DeepLesion slices with simulated low-dose acquisitions, including patch-scale ablations and lung, soft-tissue, and bone evaluations. On 220 test slices from 31 patients, LBW-NPS reduces a local spectral gap related to the loss, on $64\times64$-pixel evaluation windows, by 31.9% relative to pooled band-weighted NPS, without a statistically significant PSNR change. This improvement is supported by lower errors relative to the reference in average NPS frequency and gray-level co-occurrence matrix (GLCM) measures not used in the loss, evaluated in homogeneous soft tissue. Local band-power matching therefore improves regional texture agreement without changing the denoising architecture.

0.48
6

OffBeat: Multicoset Sampling for 4D Capture Beyond the Camera Frame Rate

cs.CV eess.IV ·2026-11-19 ·Chi-Wei Lee, An-Kai Chen, Cheng-Han Chiang, Yi-Chun Chang, Po-Chih Kuo
code/data
Abstract · Project page: https://arthur031221.github.io/offbeat/

For 4D reconstruction, a synchronized multi-camera rig records all views at the same timestamps and misses the motion between them. Staggered triggers spread the same frames over more timestamps. However, when the cameras along each row fire one after another, as in 4DSloMo's schedule on the N3DV rig, the row acts as one moving camera that confounds depth with motion. We introduce OffBeat, which models a staggered rig as a spatially distributed multicoset sampler: shifted copies of one sampling grid. From the calibration alone, OffBeat derives camera groups that fire together and their firing order. Since one group records each timestamp, a short-lived primitive can fit an error its cameras share, such as a color offset, and flicker in novel views. We show that a primitive's opacity over time weights all groups equally, for every number of groups, only if it lasts at least one camera frame interval. On Spacetime Gaussians, a minimum lifetime approximates this bound, and a closed-form smoothed box of that length satisfies it exactly, with less flicker than a Gaussian in its place at nearly equal PSNR. In simulated staggered capture on N3DV, OffBeat outperforms the full 4DSloMo pipeline with video diffusion on every test frame, by 3.04 dB in mean dynamic-region PSNR. Between the first and last synchronized frame, it outperforms the best synchronized method of each scene, with or without frame interpolation, by 1.98 dB in mean dynamic-region PSNR, while synchronized capture is better at its own frames. On PanopticSports, in this frame range, OffBeat is comparable in PSNR to synchronized capture with interpolation. On every N3DV scene, replacing 4DSloMo's schedule with ours raises the dynamic-region PSNR of Spacetime Gaussians, 4DSloMo without diffusion, and our reconstruction. Multi-camera rigs could follow faster motion at the same frame count by changing only when each camera fires.

0.41
7

AIstatLab at BraTS-GoAT 2026 Task 3: Quality-Controlled Consensus Pseudo-Labeling and Dense Expert Adaptation

eess.IV cs.AI ·2026-11-19 ·Heeseung Shin, Changwon Lim
publishedcode/data
Abstract · 12 pages; BraTS 2026 Challenge, MICCAI 2026

BraTS-GoAT Task 3 evaluates brain-tumor segmentation across heterogeneous entities using shared ET, TC, and WT regions. We present a 3D ResidualEncoderUNet trained with quality-controlled consensus pseudo-labels, a training-only nested-region objective, and a four-expert bottleneck adapter. Five-fold ResEnc-M/L teachers gener ated predictions for 1,138 unlabeled cases; fusion, hierarchy enforcement, and confidence-and-agreement screening retained 983 for training with 1,351 annotated cases. The final five-fold ResEnc-M entry achieved mean DSC 0.834, mean NSD 0.510, and Acalc = 0.6720 on the validation server. Component effects were modest and region-dependent, with the clearest gains on ET. Source code is available at https://github.com/HeeSeung-Shin/Brats2026-Goat-HS.

0.40
8

Life-IQA+: Boosting Blind Image Quality Assessment via GCN-enhanced Layer Interaction and Flexible Hierarchical Expert Specialization

eess.IV cs.CV ·2026-11-19 ·Long Tang, Guoquan Zheng, Huiyu Duan, Jie Hao, Yucheng Zhu +3 more
code/data
Abstract

Blind image quality assessment (BIQA) is essential for evaluating and optimizing visual experience. Existing BIQA methods typically aggregate features from multiple backbone stages without accounting for their unequal contributions to quality prediction. Furthermore, uniformly supervising all experts may constrain their flexibility and limit the diversity of the learned quality representations. To address these issues, we present Life-IQA+, a quality representation decoding framework that combines graph convolutional network (GCN) enhanced layer interaction and flexible hierarchical expert specialization. Specifically, the layer interaction module constructs quality queries from GCN-refined deepest-stage features and uses penultimate-stage features as keys and values, thereby enabling cross-layer representation interaction via the cross-attention mechanism. Building on these representations, we further introduce a flexible hierarchical mixture-of-experts (MoE) architecture comprising a densely activated shared expert layer and a sparsely activated routed expert layer. To enhance the representation diversity and ability of experts, we apply auxiliary classification supervision to a subset of shared experts using distortion-type labels for synthetic datasets and discretized quality-level labels for authentic datasets. Experiments on synthetic and authentic distortion benchmarks, together with controlled ablations of expert configurations and supervision strategies, show that Life-IQA+ achieves competitive prediction accuracy with a favorable balance between accuracy and computational cost. The code is available at: https://github.com/TANGLONG2/Life-IQA-PlusPlus.

0.38
9

VoxSAOR: Semantic-Aware Occupancy Robustification via Aleatoric Uncertainty Modeling

cs.CV cs.ROeess.IV ·2026-11-16 ·Mengfei Duan, Yuheng Zhang, Guoqiang Zhao, Yuanfan Zheng, Kailun Yang +1 more
code/data
Abstract · The source code will be made publicly available at https://github.com/MengfeiD/VoxSAOR

Vision-based 3D occupancy prediction provides a dense semantic representation of scenes for autonomous driving and embodied perception, yet remains vulnerable to occlusion, depth ambiguity, and projection errors that induce spatially varying reliability in voxel features. Existing methods typically map voxel representations to semantic predictions without explicitly modeling such observation-induced feature variations. To address this limitation, we propose VoxSAOR, a semantic-aware occupancy robustification framework that models aleatoric uncertainty through feature-space proxies. It first quantifies Local Semantic Consistency (LSC) to derive a voxel-wise structural stability prior and uses cross-view semantic consensus to filter unreliable semantic correspondences. Within each semantic category, spatially matched stable and ambiguous voxels form stable-to-ambiguous feature transitions, which are modeled by a class-conditional diagonal Gaussian distribution, capturing both feature displacement and dispersion. Guided by these proxy distributions, Aleatoric Regime Ensemble Learning (AREL) trains independently parameterized prediction heads using feature perturbations at progressively increasing scales, with perturbation strength modulated by structural reliability. At inference, proxy modeling and sampling are disabled, and all heads process the same observed features; their output probabilities are then averaged to produce a deterministic consensus prediction without requiring sampling. Experiments across multiple datasets and occupancy backbones demonstrate the effectiveness of VoxSAOR in improving semantic occupancy prediction, long-tail recognition, and predictive calibration. The source code will be made publicly available at https://github.com/MengfeiD/VoxSAOR.

0.38
10

MADJEPA: Enhanced Multi-Stage Joint-Embedding Predictive Architecture for Medical Anomaly Detection

eess.IV cs.AIcs.LG ·2026-11-18 ·Ioana-Sabina Stoian, Florinel-Alin Croitoru, Vlad Hondru, Andreea Iuliana Ionescu, Andrei Paun +1 more
publishedcode/data
Abstract · Accepted at WACV 2027

Anomaly detection in medical images is a complex task, requiring the development of a robust model using only healthy patient data. Without access to labeled data, modern approaches typically employ self-supervised learning to obtain a model of normality. Since world models promise to build strong internal representations of their environment, we consider them as suitable candidates for the medical anomaly detection environment, namely medical investigations of healthy patients. To this end, we propose MADJEPA, a medical anomaly detector based on an enhanced multi-stage joint-embedding predictive architecture (JEPA). We design a multi-stage training pipeline to produce a robust detector: (1) image-based JEPA (I-JEPA) training aims to learn a strong representation of normal training data; (2) target encoder distillation aims to modulate over-generalization of I-JEPA representations to abnormal data; (3) pseudo-anomaly classification aims to calibrate anomaly predictions by learning a tight boundary around the normal data manifold. To demonstrate our design, we carry out comprehensive experiments on six datasets covering various medical image domains (e.g.~MRI, OCT, X-ray, histopathology), comparing our MADJEPA with numerous state-of-the-art methods. The results show that our carefully designed world model, MADJEPA, attains competitive results, ranking first on three datasets. Our ablation studies further confirm the utility of each training stage, indicating that I-JEPA alone is not sufficient to obtain competitive results in medical anomaly detection. We publicly release our code at https://github.com/Sabina085/madjepa.

0.37
11

MambaLIFT: Reference-Based Mechanism-Aware Attribution for VMamba

cs.AI cs.CVeess.IV ·2026-11-19 ·Jintu Kakati, Niladri B. Puhan
hot direction
Abstract

Attributing predictions of visual state-space models remains challenging because input-dependent selective dynamics couple feature selection, recurrent state propagation, and shared computational pathways. We introduce MambaLIFT, a reference-based, multiplier-first attribution framework for VMamba that propagates contributions through its computational graph using interaction-aware rules for selective-scan injection, recurrent memory, LayerNorm, and shared pathways. MambaLIFT decomposes the reference-relative class-logit difference, \(f_c(x)-f_c(x^0)\), by spatial position, VSS block, scan direction, and computational mechanism. Experiments on ImageNet-1K evaluate VMamba-T and VMamba-B, with hyperparameters selected on a calibration set and faithfulness assessed on a disjoint held-out evaluation set. MambaLIFT achieves numerical conservation to floating-point precision across audited attribution interfaces in both configurations. Under mean-colour pixel flipping, it achieves significantly higher mean faithfulness scores than MambaLRP on both configurations and the highest scores among the evaluated methods, including Integrated Gradients with matched references. Under blurred replacement, MambaLIFT is non-inferior to MambaLRP on VMamba-T and equivalent on VMamba-B, indicating that its advantage depends on the replacement protocol. Ablations on VMamba-T show that interaction allocation, temporal propagation, and pathway composition affect attribution maps. Mechanism-level analyses further show that exact relevance conservation does not imply additive effects under finite interventions: the mechanism decomposition accounts for the reference-relative logit difference but does not estimate intervention effects or establish causal validity.

0.37
12

Underwater Spectral Recovery via Multi-View Hyperspectral Imaging

eess.IV cs.CV ·2026-11-20 ·Jonathan Sterckx, Alice James, Avishkar Seth, Laurens Diels, Michiel Vlaminck +3 more
Abstract · Preprint. Code and data can be shared upon publication. 27 pages (15 main, 12 appendix), 12 figures

Underwater imaging suffers from wavelength-dependent absorption and scattering that distort scenes and obscure spectral signatures. While RGB restoration improves visual clarity, the outputs remain broadband and tied to the sensor's color space. We introduce a physically grounded framework that lifts underwater restoration to continuous spectral radiance using multi-view hyperspectral imaging. By representing continuous spectra via low-rank basis functions and leveraging multi-distance observations, our framework jointly constrains scene radiance and water parameters. We employ a robust sparse-to-dense pipeline: water parameters are estimated from consistent multi-view matches and then applied globally to invert the light transport model across the full images. Validated on physics-based synthetic data rendered via the Mitsuba 3 spectral path tracer, our method recovers physically meaningful radiance spectra and, as a downstream application, outperforms standard image restoration baselines.

0.36
13

From Tokens to Pixels: Training-Free Guided Upsampling of Frozen CARL Features for Hyperspectral Imaging

eess.IV cs.CV ·2026-11-20 ·Dominik Fromme, Ellen Markowski, Tim Streckert, Jörg Thiem
benchmark
Abstract · 17 pages, 16 figures, 5 tables. Code and result tables: https://gitlab.fb10.fh-dortmund.de/fb10-opensource/CARL-tokens-to-pixels

Camera-agnostic foundation models such as CARL map spectral images from arbitrary sensors into a shared feature space, but deliver their features only on a token grid at one eighth of the input resolution. The usual bilinear interpolation blurs material boundaries over about one token and rounds off corners. We investigate how much spatial accuracy image-guided upsampling recovers for frozen CARL features without training the encoder or the upsampler. We compare joint bilateral upsampling (JBU), a guided filter and the pretrained AnyUp, each with the hyperspectral image or an RGB rendering as the guide. A hyperspectral ColorChecker dataset acquired specifically for this study, with model-independent reference geometry measured to sub-pixel precision, serves as the evaluation benchmark. JBU with the hyperspectral guide raises the Boundary IoU from 13 to 67 % and reduces the effective edge width of the features from 38 to 4 px, close to the resolution of the raw spectra. The effect occurs in all 24 patches of the ColorChecker and replicates on an additional recording. On placenta and oral cavity images, the feature edges also become markedly qualitatively sharper. For sharp, high-contrast boundaries, JBU is the most accurate and most economical method. On tissue with softer transitions, the pretrained AnyUp yields qualitatively sharper contours. An analysis of 78 simulated band configurations shows that the gain persists in every configuration as long as the head matches the configuration. Image-guided upsampling is thus a simple, training-free step for applications that use CARL frozen with linear heads.

0.35
14

Gaussian Splatoms: Direct Atomic Structure Identification in Electron Tomography

eess.IV cs.CV ·2026-11-17 ·Nalini Singh, Tiffany Chien, Cedric Lim, Arthur R. C. McCray, Colin Ophus +1 more
Abstract · 26 pages, 14 figures

Atomic electron tomography (AET) computationally reconstructs the 3D atomic structure of materials from a series of 2D projection measurements acquired at different tilt angles. Inspired by Gaussian splatting techniques from computer vision, we introduce an atom-centric parameterization for modeling AET samples. Instead of a conventional volumetric representation with a grid of voxels, we model the sample as a list of atoms, where each atom is a 3D Gaussian characterized by learned location, scale, and amplitude. The Gaussian model is a natural fit for atoms that allows us to easily incorporate prior information grounded in physics; we impose isotropy of atoms, a minimum interatomic distance, and realistic atomic radii. We show in simulation that our method is more robust than volumetric baselines to real-world imaging challenges, including a limited number of measurements and low electron dose. We further show that our method yields a more physically plausible reconstruction of an experimental 23,000 atom iron-platinum nanoparticle than a previously published volumetric reconstruction. Beyond tomography, our representation is a promising tool for any atomic resolution imaging modality (e.g. multislice electron ptychography).

0.35
15

How Much Does Saliency Accuracy Matter for Saliency-Guided 360-degree Image Compression?

eess.IV cs.CV ·2026-11-16 ·Sakib Ahmed, Sidi-Mohammed Senouci, Philippe Brunet, Guillaume Caron, Nevrez Imamoglu
published
Abstract · 8 pages, 7 figures, 1 table. Accepted at the 2027 IEEE/SICE International Symposium on System Integration (SII 2027)

Saliency-guided coding allocates bits to the regions viewers are most likely to attend, but accurate 360-degree saliency prediction is computationally expensive, an obstacle for low-latency immersive streaming applications such as robot teleoperation. We quantify how much saliency-prediction accuracy actually translates into compression gain. Building on a saliency-guided rate-distortion-optimized (RDO) learned codec, modified so that the training-time latent mask is driven by ground-truth saliency, which yields a single, predictor-agnostic codec, we evaluate saliency predictors spanning two orders of magnitude in compute on both the learned codec and H.265/HEVC. The results show that higher saliency-prediction accuracy yields diminishing compression gains: a lightweight predictor fast enough for live use (52 frames per second) captures 65% of the ground-truth oracle's bit-rate saving, a 3.3x heavier one reaches 74%, and a further 38x increase in compute adds no measurable benefit, on either codec. Therefore, lightweight predictors might also be a practical choice for latency-constrained 360-degree streaming.

0.31
16

Dem2TA: Beyond Pixels, Towards Perception

eess.IV cs.CV ·2026-11-20 ·Ping Chen, Zhongwei Lin, Xiang He, Xiangming Wang, Kai Zhang +5 more
Abstract · 16 pages

Task-oriented image signal processors (ISPs) adapt RAW-to-RGB processing for downstream perception. However, explicit demosaicing is often simplified, kept fixed, or optimized primarily for reconstruction quality, leaving this stage insufficiently integrated into task adaptation. We propose \textbf{Dem2TA}, a framework that incorporates fidelity-supervised demosaicing into the adaptation of the perception pipeline. Starting from a pretrained demosaicing model, we jointly adapt the reconstruction frontend and downstream network using reconstruction and task supervision, together with complementary semantic and task representation alignment. We then freeze the adapted frontend and jointly optimize a lightweight local ISP with the downstream model to refine task-specific rendering without changing the reconstructed linear RGB. Experiments on synthetic RAW detection and box-prompted segmentation demonstrate the effectiveness of representation-guided joint adaptation and subsequent local rendering. Evaluation on a manually verified real-capture dataset further supports transfer beyond synthetic inputs. Compared with TA-ISP on the same adapted foundation, Dem2TA improves detection AP by 0.46 points and segmentation IoU by 1.06 points on synthetic COCO RAW, and segmentation IoU by 0.63 points on real captures.

0.30
17

Micrograph B-factor estimation via Wilson statistics

eess.IV q-bio.BM ·2026-11-18 ·Ayelet Heimowitz, Amit Singer
Abstract

The single-particle cryo-electron microscopy imaging process is known to cause exponential decay in the amplitude and power spectra of proteins. This decay is modeled by the B factor and is currently corrected as a post-processing stage of the 3D reconstruction. As a consequence, all experimental images in the dataset are assumed to share the same B factor. In this paper, we suggest a novel approach wherein the B factor is determined and corrected as a preprocessing step to the reconstruction. We show such an approach can improve reconstruction resolution.

0.30
18

MedImgAnnotator: batch wise medical image annotation and preprocessing tool

cs.CV eess.IV ·2026-11-17 ·Ewunate Assaye Kassaw, Amit Mehndiratta, Peush Sahni, Anup Singh
code/data
Abstract

The curation of large cohort datasets for developing deep learning models demands annotating or editing over the AI-predicted labels. However, openly available annotation tools are time-consuming, as they involve complex navigational steps and do not support batch processing. This study aimed to develop a simple, fast, semiautomated batch-annotation tool named MedImgAnnotator. The tool was created by integrating editing tools, image mask pair matching logic, preprocessing functions, object detection tool, and a plugin management system. Its performance was evaluated in terms of active annotation time and ease of use by the developer and 12 users using open-source MR and CT scans. Additionally, the tool had been used by the MICCAI 2026 CARE Challenge liver segmentation best performance winner to annotate liver masks from 6412 MRI volumes. The evaluation results showed that MedImgAnnotator reduced active annotation time from 206.5+/-32.87 (average active annotation time of openly available tools) seconds to 59 seconds. The Wilcoxon signed-rank test of 12 users evaluation results recorded P values of 0.032 and 0.008 for the active annotation time and higher ease of use rating metrics, respectively, indicating that the current tool significantly reduces annotation time and enhances ease of use. Moreover, the tool utilization for annotating different regions of interest from different modality scans and body regions shows its usability across modalities and areas of interest. MedImgAnnotator, which significantly reduces active annotation time for large imaging cohorts, is available as an executable file and as a Python script. Access link: https://ewunateassaye.github.io/developed-tools/medimgannotator.html

0.30
19

Streaming Generative Video Compression with Embedding Alignment and In-Context Propagation

eess.IV cs.CVcs.MM ·2026-11-17 ·Zhitao Wang, Hengyu Man, Han Liu, Wenrui Li, Debin Zhao +1 more
code/data
Abstract · 15 pages, 18 figures, 5 tables, including supplementary material

Video compression at ultra-low bitrates presents substantial challenges in preserving perceptual quality. Although pretrained video diffusion transformers (DiTs) provide powerful generative priors, existing generative video compression (GVC) methods built on them typically rely on computationally expensive VAE decoders to reconstruct video frames. Moreover, jointly refining multiple frames to exploit the inherent spatiotemporal modeling capabilities of video DiTs introduces additional buffering delay. To address these challenges, we propose SGVC, a streaming generative video compression framework that adapts a pretrained latent video DiT into a causal pixel-space refiner. Specifically, SGVC projects decoded features from a contextual pixel codec directly into the DiT input embedding space. To bridge the representation gap between codec-derived embeddings and pretrained DiT embeddings, we introduce Embedding Alignment, which aligns the projected embeddings with input embeddings extracted from the original frames during training. The refined DiT hidden states are then mapped directly to the pixel domain through a lightweight reconstruction path, bypassing the pretrained VAE decoder. To further exploit the spatiotemporal priors of the video DiT while maintaining causal decoding, we introduce In-Context Propagation, which reuses layer-wise K/V states across frames to exploit historical generative context, improving temporal consistency without requiring clip-wise buffering. Extensive experiments demonstrate that SGVC achieves competitive rate-perception performance, with average BD-rate savings of 71.97% over S$^2$VC in terms of DISTS. Project Page: https://chigland.github.io/SGVC/

0.29
20

Investigating the Benefit of Transfer Learning from the Locus Coeruleus for Substantia Nigra Pars Compacta Segmentation

eess.IV cs.CV ·2026-11-16 ·Tayebeh Bahador, Max Dünnwald, Matthew J. Betts, Emrah Düzel, Steffen Oeltze-Jafra
Abstract · 5 pages, 3 figures, 1 table. Submitted to IEEE ISBI 2027

The substantia nigra pars compacta (SNpc) is a small midbrain nucleus that degenerates early in Parkinson's disease (PD). T1-weighted FLASH MRI enables its visualization and may support early detection of neurodegeneration. However, manual segmentation is difficult and time-consuming, and deep learning models often suffer from the limited availability of labeled data. Transfer learning (TL) may help by adapting pre-trained models to small datasets. We investigate whether TL from a model trained on the locus coeruleus (LC), a nucleus with a similar appearance in this sequence, improves SNpc segmentation. Several TL strategies were evaluated using a 3D U-Net. With as few as 5-14 labeled subjects, TL and training from scratch achieved similar performance, reaching a Dice similarity coefficient of up to 0.77, close to reported inter-rater agreement. No TL strategy differed significantly from training from scratch, suggesting that initialization from the LC offers no significant benefit for SNpc segmentation.

0.28
21

Deterministic Temporal Embedding for Calcium Imaging Trace Extraction

cs.CV cs.LGeess.IV ·2026-11-19 ·Qi Gao, Julius Beichert, Miriam Ratliff, Karl Rohr
Abstract · 5 pages. Submitted to IEEE ISBI 2027

Reliable extraction of calcium-dependent fluorescence traces in calcium imaging sequences requires identifying pixels whose fluorescence intensity reflects the same underlying cellular activity. We present a deterministic temporal embedding framework that maps pixel-wise fluorescence traces to a low-dimensional representation in which temporally coherent sources form spatially coherent regions. Starting from a fuzzy-neighborhood graph and spectral initialization, we optimize a class-balanced cross-entropy objective using exact sparse attraction and a deterministic particle-mesh decomposition of the dense repulsive interaction with sparse edge compensation, avoiding stochastic negative sampling. The resulting latent representation is spatially decoded into reliable source supports for trace extraction without imposing an explicit cellular shape prior. Experiments on synthetic and in vivo two-photon calcium imaging data demonstrate robust recovery of irregular and spatially touching sources together with efficient deterministic embedding optimization.

0.27
22

LIC-Audit: How Comparable Are Reported Gains in Learned Image Compression?

eess.IV cs.CVstat.AP ·2026-11-17 ·Haisheng Fu, Jie Liang, Runyu Yang, Feng Ding, Xin Dong +2 more
benchmark
Abstract · 31 Pages, 4 figures

Learned image compression (LIC) papers often report BD-rate improvements of only a few percent. They are measured against VTM reference software whose version keeps changing: the claims we audit name 7 versions, 5 in 2025 papers alone. But how comparable are these numbers across papers, and what evidence should future papers give for such small gains? We introduce LIC-Audit, an analysis of 353 released rate-distortion curves from 36 repositories, and a controlled re-evaluation of eight public codec releases with 28,193 encode-decode records. We identify three problems. First, different VTM reference runs change BD-rates by up to 3.56 percentage points, and on CLIC Pro published numbers order 10 of 55 method pairs differently from a common computation; comparing codecs directly over a fixed quality range removes this dependence. Second, releases use different and mostly undocumented conventions for counting bits, computing PSNR, and padding images. Under consistent measurement, the GLIC method's 1.00% lead over the HPCM method on Tecnick becomes a 1.43% deficit, changing only the padding reverses the comparison of HPCM and CMIC, and most gaps narrow when MS-SSIM replaces PSNR. Third, average curves hide how much results vary from image to image, so whether a small gain is statistically significant depends on the assumed variation. An optimistic assumption calls 12.0% of comparisons between equally good codecs significant on test sets as small as Kodak, instead of 5%; a cautious one leaves 18 of 45 differences between recent codecs undecided, yet per-image results show 12 of them to be significant. Beyond auditing past results, LIC-Audit provides a versioned evaluation protocol, a public leaderboard website with a scoring tool, source-linked benchmark data, per-image measurements, and reporting guidelines, to help future LIC papers make comparable and verifiable claims of progress.

0.27
23

Correspondence-Free Camera Pose Estimation by Matching Moments

cs.CV cs.LGcs.ROeess.IV+1 ·2026-11-16 ·Subhransu S. Bhattacharjee, Dylan Campbell, Rahul Shome
Abstract · 65 pages, including references and appendices; under review

The blind perspective-$n$-point (PnP) problem is to estimate the pose of a calibrated camera from 2D and 3D point sets with unknown correspondences. We show that, for complete, noiseless observations, fourteen permutation-invariant image moments up to order four identify a fixed camera pose for almost every 3D point set containing at least twenty points. Our learning-free method, MomentPnP, matches these moments between the observed 2D points and the projected 3D points to initialize a camera pose without correspondences and refines the pose and correspondence weights using expectation--maximization. Across the test sets of three benchmarks, our method reduces median rotation error by $5$--$170\times$ relative to the best learned baseline, both with and without outliers. We recover accurate poses even with as many outliers as inliers. On dense ETH3D scans, pose accuracy improves as the point sets grow, even as individual correspondences become harder to resolve.

0.27
24

MambaSplit: Severity-Robust and Inference-Efficient Semantic Unmixing of Fluorescence Microscopy Image Data

eess.IV cs.CVq-bio.QM ·2026-11-19 ·Aman Kukde, Ruggiero Santeramo, Federico Carrara, Ashesh Ashesh, Igor Zubarev +1 more
Abstract · 28 pages, 15 figures, 23 tables; main paper (8 pages) followed by supplementary material

The number of structures fluorescence microscopy can image in one sample is limited by how few fluorophores can be separated without significant spectral overlap. Semantic unmixing circumvents this limit by imaging two structures in one fluorescent channel and computationally separating the superimposed image into one image per structure. Because pixels rarely identify their structure, unmixing requires both local and long-range spatial context. The relative brightness of the two structures is unknown and can be very uneven, so predictions must remain accurate across mixing severities, from balanced mixtures to ones where a structure is barely visible. Existing methods either process small image patches or add context through auxiliary pathways that slow inference on large images. We present MambaSplit, a hierarchical state-space encoder with a convolutional decoder that captures context across large tiles in linear time and predicts both channels in one deterministic pass. MambaSplit trains either on computationally summed channel images with random mixing ratios, where a lightweight head estimates the unknown ratio and conditions the decoder on it, or on experimentally acquired superpositions. Across five datasets and nine mixing ratios, MambaSplit achieves the highest RI-PSNR, by up to 3.0 dB, in 11 of 15 dataset-severity combinations and ties in one more, while running 5.9x faster than the strongest baseline. On acquired superpositions, fine-tuning a model pretrained on summed inputs matches or exceeds all baselines. Ablations show that accuracy and robustness come mainly from the training recipe: large tiles, mixing ratios sampled across their full range (up to 11 dB over fixed-ratio training), and independently drawn channel crops (3.9 dB on BioSR). The state-space backbone makes large tiles affordable, enabling high-content screening and event-driven smart microscopy.

0.26
25

Virtual EMI Receiver Generation (VERGE) for Improved EMI Removal in MRI

eess.IV ·2026-11-17 ·Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris +1 more
unusual
Abstract

MRI is not designed to operate in the presence of EMI emitting electronic devices. To accomodate this, we propose VERGE which improves on previous EMI removal methods and can operate without external EMI sensors. VERGE estimates a reference coil non-linearly from all imaging and non-imaging coils by training a small per-scan convolutional neural net to generate a virtual coil. The virtual coil is then used with STRIDE, a reference-based EMI removal method. For single-source EMI contamination, VERGE performed similarly to the reference method. For multi-source dynamic EMI contamination, VERGE outperformed the comparison methods. Notably, VERGE with zero physical EMI sensors outperformed the comparison methods even with two physical EMI sensors. A non-linearly estimated virtual EMI coil improves reference-coil-based EMI removal under dynamic multi-source EMI, and enables effective EMI removal without physical EMI sensors or training data.

0.26
26

Learned Score-Based Turbo Message Passing for Compressive Image Recovery

eess.IV ·2026-11-20 ·Peihang Li, Hao Jiang, Xiaojun Yuan
Abstract

Score-based generative models have been incorpo-rated into message passing algorithms for compressive image recovery, providing a prior for the denoising module in message passing. Score-based generative models assume the input signal to be a clean signal perturbed by independent and identically distributed (i.i.d.) Gaussian noise. Yet, this assumption often fails during message passing, leading to slow convergence and limited reconstruction quality. In this letter, we propose the learned score-based turbo message passing (LSTMP) algorithm to overcome this limitation. By employing a deep unfolding framework, LSTMP unrolls the iterative process into a neural network, enabling the denoiser to adapt to complicated noise distributions inherent in the iterative updates. Furthermore, by treating the denoiser as an iterative solver, we incorporate the likelihood information of compressed measurements into the neural network of the denoiser, resembling the message passing between linear and nonlinear modules in STMP. Experiments on the FFHQ dataset show that LSTMP achieves convergence in no more than three iterations while delivering high-ffdelity re-constructions, signiffcantly outperforming the existing baselines.

0.26
27

Signs of Wear: Evaluating Intelligent Speed Assistance Under Synthetic Adverse Conditions

cs.CV eess.IV ·2026-11-16 ·Johannes Fabian Hahn, Mao Shan, Julie Stephany Berrio Perez
unusual
Abstract

Intelligent Speed Assistance (ISA) systems rely on cameras to recognize speed-limit signs, yet existing benchmarks underrepresent the weathered, dirty, and overgrown signs commonly encountered on rural roads. We use generative image editing to introduce different forms of wear into real street-level images of speed-limit signs. The resulting ISA-Wear dataset contains paired original and edited images. Guided by text instructions, a multimodal image-editing model adds snow, rust, vegetation, faded paint, or mud to the speed-limit sign in a street-level frame at three severity levels. Where appropriate, the surrounding scene is adapted as well, and the viewpoint is kept. Every edited frame has an unedited counterpart, and we only evaluate frames whose original is recognized correctly, so any failure can be attributed to the wear. Since the model alters the sign's geometry in 21\% of the edits, all edits are filtered by a geometric check and a manual review. Severity is measured as the LPIPS distance between the original and the edited sign plate. On 716 worn frames, we find that in detect-then-read pipelines, wear breaks detection before it breaks reading. The detector finds only 62\% of the worn signs, even though it finds every one of them in the original frames. Missed detections account for 78--87\% of failed reads, a pattern that a zero-shot detector shares. Given the annotated sign box, as in the crop-based benchmarks, a classifier still reads 78\% of the worn signs, but only 56\% when it has to rely on the detector

0.26
28

Susceptibility source separation via Closed-form Alternating Newton-type Optimization

eess.IV ·2026-11-19 ·Ignacio Contreras-Zúñiga, Cristian Tejos, Carlos Milovic
Abstract

Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.

0.25
29

SCAN: Site-Aware Collaborative Privacy-Preserving Adaptation of Vision-Language Models for Neurological Disease Classification

cs.CV eess.IV ·2026-11-16 ·Nikhil J. Dhinagar, Rishab Pendam, Harmony S. Cen, Sophia I. Thomopoulos, John P. John +5 more
Abstract

Worldwide neuroimaging data could strengthen diagnostic foundation models, but privacy rules often prevent centralizing brain MRI scans. We present SCAN, a site-aware collaborative adaptation framework for Neurological Disease Classification that lets new sites adapt a 3D medical vision-language model (VLM) without retraining or sharing patient scans. Each site keeps exact class prototypes for local prediction and can share privacy-protected class summaries: norm-bounded sums and counts perturbed once with calibrated noise. Using 7,641 scans from 67 sites across 12 countries, covering Alzheimer's disease (AD), stroke, epilepsy and controls, we assess local adaptation, cross-site benefits, and effects on existing sites. At seven unseen sites, the frozen VLM's zero-shot AUCs were 0.833-0.945 for AD and stroke. Training-free local prototypes improved epilepsy AUC at three sites from 0.598/0.625/0.508 to 0.684/0.729/0.762 and AD AUC at one site from 0.833 to 0.863, nearly matching a classifier trained at each site (mean AUC 0.757 vs. 0.759). With differential privacy ($ε$ = 4), new sites contributed without materially reducing accuracy at existing sites (AUC change $\leq$0.2%), although gains from sharing were limited, and membership attacks performed near chance. SCAN offers hospitals a worldwide framework to adapt and share brain MRI VLMs without exchanging scans or retraining.

0.24
30

Particle picking with an earth mover's seminorm

eess.IV ·2026-11-20 ·Dvir Moshe, Amit Moscovich, Amit Singer, Ayelet Heimowitz
Abstract

Particle picking is a key step in single-particle cryo-electron microscopy. It is a challenging task where tomographic projections of proteins and other macromolecules are identified in extremely noisy images. In this work, we introduce a particle picker based on a seminorm defined in terms of a fast wavelet approximation to the earth mover's distance. Our picker is template-free, self-supervised and does not require any prior knowledge of the molecules of interest other than their approximate size. We test it on three public datasets and show that it achieves state-of-the-art reconstructions.

0.24
31

FirstCross: Convex Single-Photon 3D Reconstruction from Sparse Views

cs.CV eess.IV ·2026-11-19 ·Chi-Wei Lee, Cheng-Han Chiang, Yi-Chun Chang, An-Kai Chen, Po-Chih Kuo
theorycode/data
Abstract · Project page: https://arthur031221.github.io/firstcross/

Single-photon lidar records the arrival time of each returning photon, enabling 3D reconstruction from few views and scarce photons. However, leading neural methods such as Transientangelo require over an hour of non-convex per-scene optimization, and their accuracy degrades as photon flux decreases. We propose FirstCross, a network-free approach that instead solves a short sequence of convex problems on a voxel grid. For a solid object, the Poisson likelihood of a ray with given signal and background rates depends on the scene solely through its first crossing, the point where the ray first enters the object. Decomposing this likelihood yields two tractable terms. The first penalizes surfaces in front of detected photons and admits a tight convex closure, namely volume rendering with a running-maximum transmittance in place of NeRF's product transmittance. The second accounts for photons that no surface explains and admits a convex upper bound once the object is assumed to be thick behind each detected surface point. Compared with Transientangelo under its own real-data protocol, FirstCross achieves lower depth error across every test scene, view count, and flux level. With three views and 100 times fewer photons than at the protocol's lowest flux, our mean object depth error stays under half of Transientangelo's with all photons. Given our detected surface points, the best classical fusion has 1.3 to 1.8 times our three-view error across flux levels. On real room-scale captures with 1% of their photons, TransientNeRF has 2.8 to 7.7 times our error. FirstCross lets few-view single-photon scanners cut exposure to 1% and reconstruct an object in about a minute on one GPU.

0.24
32

Joint Image Denoising and Interpolation via Mixed Graph Filtering

eess.IV cs.CVeess.SP ·2026-11-18 ·Gene Cheung, Niruhan Viswarupan, Romisaa Elsaidy
Abstract

Images often require both denoising and interpolation, yet treating the two tasks separately is suboptimal: interpolation introduces correlated noise that complicates subsequent denoising, while denoising may remove image details useful for interpolation. In this paper, we study joint image denoising and interpolation from a mixed graph filtering perspective, where denoising is modeled using undirected graph filters and interpolation using directed graph filters. We first establish that, under mild conditions, any (pseudo-)linear denoiser and interpolator can be interpreted as solution filters of maximum a posteriori (MAP) estimation problems regularized by undirected and directed graph smoothness priors, respectively. Guided by these results, we formulate graph-based joint denoising and interpolation problems using both directed and undirected graph structures. We characterize when joint denoising/interpolation reduces to a separable pipeline and when a genuinely coupled optimization is required. For the non-separable case, we recover sparse graph operators from given denoisers and interpolators, yielding an efficient linear-system formulation solvable via conjugate gradient. Experimental results demonstrate that our proposed joint framework consistently outperforms separate denoising and interpolation pipelines across multiple denoiser-interpolator combinations.

0.24
33

Transferable Named Sparse Features for Morphology-based Gleason Grading

eess.IV cs.CV ·2026-11-18 ·Argyrios Zafeiriou, Athanasios Kallipolitis, Ilias Maglogiannis
Abstract

Deep learning systems grade prostate biopsies at the level of pathologists, but most report a grade without the glandular architecture that justifies it. This work presents a grading system built on a sparse code over the tokens of a pathology foundation model. A sparse autoencoder pretrained on biopsies is aligned with multi-reader annotations, so that 69 of its 2048 features are named after Gleason morphologies such as cribriform glands, cords, and comedonecrosis. The same code feeds a grading network, which reads all features to predict Gleason patterns and the Grade Group, while morphology maps read directly from the named features. We evaluate the system on five public datasets that include needle biopsies, tissue-microarray cores, multi-reader annotations, and three scanners. The morphology maps remain stable across alignment runs and, without retraining, detect cribriform glands in external biopsies (area under the receiver operating characteristic curve, AUROC, 0.849) and pattern 5 in unseen cores when evaluated by up to six pathologists (AUROC 0.846 to 0.919). In an independent biopsy cohort, Grade Group agreement with three pathologists on Leica scans is close to their agreement with each other. Removing the named features reduces the corresponding Gleason pattern predictions by 49% to 98%, with effects larger than those from 20 activity-matched random feature removals. These results show that a shared sparse representation can support competitive Gleason grading while providing named morphological evidence that transfers across datasets and whose contribution to grading can be measured directly.

0.24
34

SWIMSS: An Open Multi-Center SwinUNETR Model for Multiple Sclerosis White Matter Lesion Segmentation

eess.IV ·2026-11-17 ·Federico Spagnolo, Po-Jui Lu, Mario Ocampo-Pineda, Lester Melie-Garcia, Esther Ruberte +23 more
code/data
Abstract

Purpose: To develop and validate SWIMSS (SWInUNETR for Multiple Sclerosis white matter lesion Segmentation), a SwinUNETR-based deep learning (DL) model for reliable automated white matter (WM) lesion segmentation, in a large multicentric cohort of people with multiple sclerosis (pwMS). Methods: A real-world longitudinal dataset of 1,385 pwMS from seven Swiss clinical centers was used to train, validate, and test SWIMSS and two state-of-the-art DL architectures: UNETR and MSSegDiff. Inference results obtained with LST-AI were also compared. Preprocessed magnetization-prepared rapid acquisition gradient echo and fluid-attenuated inversion recovery MRI sequences, acquired with various MR systems and field strengths, served as model inputs. Model performance was evaluated using the Dice similarity coefficient (DSC) with 95% confidence intervals (CI). Results: SWIMSS achieved the highest performance, with a DSC of 81.37 (95% CI: 80.63-82.11), outperforming UNETR (79.06; 95% CI: 78.33-79.79), MSSegDiff (75.70; 95% CI: 74.97-76.43), and LST-AI (63.19; 95% CI: 62.08-64.30). Normalized DSC followed a similar trend, with SWIMSS reaching 84.88. Lesion detection F1 achieved 81.14. Statistical analyses confirmed its superior performance (p < 0.001). Conclusion: SWIMSS achieved state-of-the-art performance for WM lesion segmentation. By making this model publicly available, we enable broader access to high-quality segmentation tools, allowing smaller centers, often lacking large annotated datasets or computational resources, to benefit from a model trained on a diverse, large-scale cohort. This promotes more equitable access to advanced imaging analysis and supports reproducibility and standardization in MS research.

0.23
35

AnyVIO: Feed-Forward Streaming Visual-Inertial Odometry Across Platforms

eess.IV ·2026-11-19 ·Omoruyi Atekha, Marcus Greiff, Ray Zhang, Luca Carlone
Abstract · 11 pages

Geometric foundation models (GFMs) estimate camera mo- tion and scene structure from images without requiring ex- pert parameter tuning, but either lack metric scale or rely on learned priors to infer scale, which is unobservable from monocular images alone. Inertial sensing offers a way to observe metric scale, but existing methods add inertial in- formation through a filter or factor graph, which reintro- duces bespoke parameter tuning and optimization costs that can grow with the trajectory. To bridge this gap, we present AnyVIO, a real-time, feed-forward streaming model for monocular visual-inertial odometry (VIO), which combines a streaming GFM with an inertial foundation model (IFM). Both the GFM and IFM predict the metric motion between consecutive frames, and a lightweight learned fusion head quantifies the reliability of each estimate and blends them in a single forward pass. Across nine datasets recorded from cars, legged and ground robots, and handheld and head- mounted devices, AnyVIO reduces the metric position error of its visual model by 36% while publishing each pose esti- mate 70 ms after an image is received. We further deploy AnyVIO onboard two real vehicles at up to 140 km/h, where it remains accurate in poor lighting and heavy dust.

0.22
36

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.21
37

Feasibility of Multifrequency Neural Network-Based Wave Inversion in Ultrasound Time-Harmonic Elastography

eess.IV cs.CV ·2026-11-20 ·Héloïse Bustin, Tom Meyer, Paul Spiesecke, Jakob Jordan, Anja Hennemuth +1 more
Abstract

Ultrasound time-harmonic elastography (THE) is a non-invasive imaging technique that measures soft-tissue stiffness. Relying on the same principle of time-harmonic shear wave excitation as established magnetic resonance elastography (MRE), THE offers full field-of-view stiffness mapping at short acquisition times and sub-second temporal resolution across organs. However, reconstruction of shear wave speed maps from acquired tissue wavefields remains challenging due to speckle noise and sparse spatial coverage of the lateral component. Deep learning methods have shown promising results for image reconstruction in transient-based ultrasound elastography modalities but remain unexplored in THE. In MRE, MF-ElastoNet, a 2D multifrequency neural network-based wave reconstruction method trained on synthetic physics-based wave data, has shown high generalizability across dynamic ranges and resolutions. We investigated the potential of a multifrequency neural network-based wave inversion for THE, by performing a first feasibility analysis. To this end, we adapted the processing pipeline of MF-ElastoNet from MRE to THE. We tested our approach on THE acquired phantom data from the algorithms for mapping elastic modulus Challenge, as well as on in vivo liver THE in 4 healthy volunteers and 14 patients with focal liver lesions, including benign focal nodular hyperplasia, and malignant hepatocellular carcinoma and adenocarcinoma. MF-ElastoNet was successfully adapted to THE with in vivo liver testing. Compared with k-MDEV, the state-of-the-art wave inversion method for THE, Bland-Altman analysis showed a mean bias of -0.02 m/s (95% limits of agreement: -0.36 to 0.33 m/s).

0.20
38

InterBand-EMG: A Cross-Band Foundation Model for Generalizable Hand-Pose Estimation

cs.CV cs.ROeess.IV ·2026-11-20 ·Zongheng Guo, Tao Chen, Dalong Du, Yijian Yang, Heng Liu +11 more
Abstract · 25 pages, 8 figures

Surface electromyography (sEMG) enables continuous hand-pose estimation, but learning representations that generalize across users and movements remains challenging. We introduce InterBand-EMG, which combines band-specific quantization with cross-band reconstruction and structured masked code prediction to learn transferable EMG representations for hand-pose tracking. We also introduce SynapMyo, an eight-channel EMG-to-pose dataset comprising 1,227.74 hand-hours from 499 users across 68 movement categories. Experiments on emg2pose and SynapMyo show that InterBand-EMG outperforms state-of-the-art baselines in joint-angle accuracy across all three generalization settings on both datasets. The source code and the SynapMyo dataset will be publicly released upon acceptance of this paper.

0.20
39

A High-Compression Transformer VAE for Efficient and Controllable 3D Medical Image Generation with Diffusion Transformers

eess.IV cs.CV ·2026-11-19 ·Bo Liu, Bingliang Zhang, Yubo Wang, Yunxiang Li, Yang Yang +2 more
code/data
Abstract

Many medical image processing tasks, such as completing missing regions or correcting acquisition artifacts, can be cast as volumetric generation conditioned on observations of the same patient. Diffusion Transformers offer scalable capacity and flexible conditioning for this setting, but they operate on a learned image representation that must preserve fine anatomical and pathological detail while keeping complete three-dimensional volumes tractable. We bring Transformer variational autoencoding and multimodal diffusion together to address this challenge. Trained on BrainTumor-256K, a 249M Transformer VAE encodes and decodes $256^3$ volumes 7.6x faster than a comparably sized CNN trained on the same collection. Their PSNR difference is near zero with training-sized crop inputs, but the Transformer leads by 0.749 dB with full-volume inputs and an unchanged scoring region. Increasing Transformer capacity to 499M improves PSNR across all four brain MRI evaluation sets while retaining 3.8x lower encoding-decoding latency than the CNN. Fast encoding also allows conditions to be constructed dynamically in image space during latent diffusion training. Within the compressed representation, a shared Diffusion Transformer integrates text and spatial references for volumetric synthesis, completion and restoration. The brain-trained autoencoder further transfers to non-brain MRI and CT without target-domain fine-tuning, extending its use beyond the anatomy and modality on which it was learned. The framework provides a reusable representation and conditioning interface for efficient, controllable medical image generation. Code is available at https://github.com/OncoMMAI/brainmri-vit-vae3d.

0.20
40

Stochastic Optimisation for Scalable Ptychographic Image Reconstruction

eess.IV physics.comp-phphysics.optics ·2026-11-18 ·Alan W. Muriithi, Jared Tanner, Jaroslav M. Fowkes, Benedikt J. Daurer
Abstract · 38 pages, 12 figures

X-ray ptychography is a lensless coherent diffraction imaging technique capable of high spatial resolution, in which an image is reconstructed by solving a large-scale inverse problem from highly redundant far-field diffraction measurements acquired under overlapping illumination. Whilst the measurement redundancy created by overlapping illumination is essential for reconstruction fidelity, it leads to computational and memory demands that scale poorly with object size and target resolution when using conventional reconstruction algorithms. This work proposes a ptychographic reconstruction framework that reduces peak memory usage and time to convergence by leveraging stochastic optimisation techniques developed for large-scale machine learning. Specifically, the framework employs stochastic gradient descent with a decaying step size that progressively reduces the effect of gradient noise, referred to here as variance reduction (VR), with gradients that agree with automatic differentiation, to optimise the ptychographic forward model using randomly sampled subsets of diffraction measurements. For an experimental dataset of 200,000 diffraction patterns of $128\times128$ pixels, VR is demonstrated to require $65\%$ of the peak GPU memory and $22\%$ of the reconstruction time of the established maximum-likelihood (ML) algorithm. The VR framework incorporates the Poisson maximum-likelihood formulation and partial coherence within a unified and extensible optimisation setting. Numerical experiments demonstrate that the framework achieves reconstruction quality visually comparable to established methods, with lower peak GPU memory and a shorter time

0.20
41

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.19
42

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.18
43

Uncertainty-Aware Multimodal Deep Learning for Prediction of Radiation-Induced Xerostomia in Head and Neck Cancer

eess.IV ·2026-11-19 ·Jin Yang, Tian Liu, Jose Penagaricano, Jing Wang, Erin L. Moshier +3 more
Abstract · 24 pages, 4 figures

To develop and evaluate an uncertainty-aware multimodal learning framework for predicting radiation-induced xerostomia in patients receiving head-and-neck cancer radiotherapy. We developed a Bidirectional Attention-enhanced Diffusion Transformer (BA-DiT) that combines self-supervised multimodal representation learning with supervised Bayesian fine-tuning. The model integrates pretreatment CT images and three-dimensional dose distributions, focusing on bilateral parotid glands while incorporating surrounding anatomical and dosimetric information. During pretraining, bidirectional cross-attention integrates anatomical and dosimetric features, while a latent Diffusion Transformer learns joint representations through diffusion-based learning, feature reconstruction, and contrastive alignment. Supervised fine-tuning employs a Bayesian classifier to predict individualized xerostomia risk and quantify predictive uncertainty, with a learnable label-transition model accounting for potential toxicity label uncertainty. BA-DiT was developed using four independent cohorts (Moffitt, Emory, MSHS, and TCIA) and evaluated against baseline and ablation models. Evaluation included predictive performance, calibration, uncertainty quantification, decision curve analysis, and patient-level case studies. In independent MSHS and Emory cohorts, BA-DiT achieved AUCs of 0.83 and 0.80, respectively, outperforming baseline models. Predictive uncertainty peaked near the decision boundary, with aleatoric uncertainty being the predominant component. Uncertainty-based selective prediction generally improved net benefit among retained patients, with greater gains at lower prediction coverage. BA-DiT enables individualized xerostomia risk prediction while providing complementary uncertainty estimates, potentially supporting informed clinical decision-making and personalized toxicity management.

0.14
44

FM4SAR-Bench 1.0: Towards A Fair Benchmark for Evaluating Foundation Models for SAR Image Interpretation

eess.IV cs.CVcs.LG ·2026-11-20 ·Mingyao Chen, Yongxiang Liu, Tianpeng Liu, Yuchen Yong, Jie Zhou +8 more
benchmark
Abstract

Foundation models have advanced SAR image interpretation but created a heterogeneous, fragmented model ecosystem. Existing models differ substantially in their input, training data, objectives, architectures, and release policy, yet the field lacks a unified taxonomy and comparative framework. Current evaluations rely primarily on task-specific benchmarks, which are ill-suited to fair comparison among models with fundamentally different input-output formats and task paradigms, and often overlook data transparency, reproducibility, interpretability, and deployment readiness. Limited SAR data accessibility also means high reported performance does not guarantee access to training data, code, or weights, limiting reproduction, benchmarking, and deployment. To address these issues, we propose a systematic taxonomy and hierarchical evaluation framework for SAR-related foundation models: five rating levels, six dimensions, and fine-grained criteria, with separate protocols for VFMs and VLMs. Beyond overall ratings, it yields interpretable multidimensional capability profiles and supports user-defined weighting, so rankings follow user priorities. Utilizing a fixed auxiliary multimodal large language model in combination with human review, we conduct a systematic meta-analysis and multidimensional assessment of 76 VFMs and 40 VLMs. In terms of SAR benchmark task performance under our framework, SAR-native VLMs do not significantly outperform remote sensing VLMs pretrained on mixed multimodal corpora in which SAR is one of several modalities. This lack of clear advantage is largely due to data availability: large-scale, high-quality, public annotated SAR data remain scarce, restricting both model and training-data scale for SAR-native models. The framework provides a structured basis for requirement-aware model selection and remains extensible as new models emerge.

0.14
45

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06