CS Paper Radar

Weekly top 100 · eess.IV

2026-W35 Aug 24 – Aug 30, 2026

Ranked from 3,938 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

CheXtriev: Anatomy-Centered Representation for Case-Based Retrieval of Chest Radiographs

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Arihanth Tadanki, Jayanthi Sivaswamy
top venuecode/data
Abstract · Accepted at the 27th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2024)

We present CheXtriev, a graph-based, anatomy-aware framework for chest radiograph retrieval. Unlike prior methods focussed on global features, our method leverages graph transformers to extract informative features from specific anatomical regions. Furthermore, it captures spatial context and the interplay between anatomical location and findings. This contextualization, grounded in evidence-based anatomy, results in a richer anatomy-aware representation and leads to more accurate, effective and efficient retrieval, particularly for less prevalent findings. CheXtriv outperforms state-of-the-art global and local approaches by 18% to 26% in retrieval accuracy and 11% to 23% in ranking quality. The code is available at https://github.com/cvit-mip/chextriev.

0.77
2

Interpretable Landsat-to-Hyperspectral Dual Super-Resolution Without Large Matrix Inversion

eess.IV eess.SP ·2026-08-24 ·Chia-Hsiang Lin, Jian-Kai Huang, Si-Sheng Young, Wei-Cheng Zheng
publishedcode/data
Abstract · 17 pages; accepted for publication in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing (JSTARS). Source code…

Direct acquisition of global hyperspectral images (HSIs) is infeasible given contemporary hardware facilities and limited resources, while global hyperspectral monitoring is critical for remote sensing applications. A more economical approach is to interpretably convert global Landsat-8/9 multispectral images into NASA's AVIRIS-level HSIs. This conversion involves both spatial super-resolution (SpaSR, 30-m to 15-m) and the highly ill-posed spectral super-resolution (SpeSR, 7-band to 172-band), collectively referred to as dual super-resolution (DualSR), whose duality between SpaSR and SpeSR has recently been established. Existing SpeSR methods, mostly designed to reconstruct CAVE-level HSIs with only 31 visible bands, are not applicable to the AVIRIS-level task involving 172 visible, near-infrared, and shortwave-infrared bands. This motivates us to customize an interpretable alternating direction method of multipliers network (ADMM-Net) using the Woodbury W-Lemma and a spectral continuity prior. Unlike conventional generative SpaSR, we employ a panchromatic sharpening strategy to recover physically grounded spatial details. However, this strategy induces very large matrix inversions (LMIs), with dimensionality proportional to the number of pixels, even after applying the W-Lemma. We resolve this issue by designing an LMI-free proximal gradient descent network (PGD-Net). Consequently, the proposed PGD-ADMM interpretable network (PAINT) achieves substantial improvements in both computational complexity and reconstruction performance. Beyond state-of-the-art reconstruction performance, PAINT improves Landsat classification from 78.98% accuracy and 76.06% kappa to 92.16% accuracy and 90.98% kappa.

0.72
3

Evidence-Driven Differential Diagnosis of Malignant Melanoma

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Anirudh Kaushik, Jayanthi Sivaswamy
top venuecode/data
Abstract

We present a modular and multi-level framework for the differential diagnosis of malignant melanoma. Our framework integrates contextual information and evidence at the lesion, patient, and population levels, enabling decision-making at each level. We introduce an anatomic-site aware masked transformer, which effectively models the patient context by considering all lesions in a patient, which can be variable in count, and their site of incidence. Additionally, we incorporate patient metadata via learnable demographics embeddings to capture population statistics. Through extensive experiments, we explore the influence of specific information on the decision-making process and examine the tradeoff in metrics when considering different types of information. Validation results using the SIIM-ISIC 2020 dataset indicate including the lesion context with location and metadata improves specificity by 17.15% and 7.14%, respectively, while enhancing balanced accuracy. The code is available at https://github.com/narenakash/meldd.

0.69
4

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

eess.IV cs.CV ·2026-08-29 ·Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling +22 more
top venue
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:032

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

0.55
5

UltraPIPS: Improving model perception in B-mode ultrasound with foundation models

cs.CV eess.IV ·2026-08-26 ·Tal Grutman, Tali Ilovitsh
publishedcode/datahot direction
Abstract · MICCAI ASMUS 2026

In medical imaging, it is common to use learned perceptual image patch similarity (LPIPS) to compare images semantically in feature space. Although backbones pretrained on natural images are widely used for LPIPS computation, B-mode ultrasound images possess distinct speckle patterns and acoustic-specific image statistics that are fundamentally different from natural images and even from other images in radiology. Consequently, we propose that domain-specific models are needed to measure perceptual similarity in ultrasound data, a finding which is not necessarily the case for other imaging modalities. We compare LPIPS metrics across downstream tasks like classification, segmentation and reconstruction using natural image, medical generalist and ultrasound backbone models and show that selection of LPIPS backbone is a non-trivial design choice. In particular, the ultrasound backbone models were more correlated with downstream performance of supervised models than classical and natural image models, and optimization of the LPIPS loss with an ultrasound backbone achieved a strong balance between reconstruction quality and realism. Our code is available at https://github.com/talg2324/UltraPIPS and introduces the UltraPIPS library, a set of LPIPS metrics based on the open-source foundation models analyzed in this paper.

0.51
6

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51
7

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50
8

Learning spatially varying regularisation parameters of low regularity for image reconstruction

eess.IV cs.CVmath.OC ·2026-08-25 ·Kostas Papafitsoros, Luca Calatroni, Andreas Kofler
Abstract

In this chapter, we review and discuss the regularity properties of spatially adaptive regularisation weight functions used in variational image reconstruction. Incorporating such weights into classical model-based regularisers, such as Total Variation (TV) and Total Generalised Variation (TGV), allows the regularisation strength to vary across the image and adapt to local image content. When appropriately estimated, these weights can thus significantly improve edge and detail preservation in the reconstructions. We review the existing theoretical literature on this topic for different regularity classes, including constant, continuous, and piecewise constant functions. Our discussion is motivated by recent work on hybrid image reconstruction methods that combine model-based regularisation with deep neural networks to learn highly adaptive regularisation weights. In particular, we discuss how the structural properties of these weights influence the reconstruction from both theoretical and practical perspectives. Through representative examples in image denoising and magnetic resonance imaging (MRI) reconstruction, we demonstrate that the learned weights are often of low regularity and can adapt not only to the image structure but also to the specific noise realisation. We conclude by highlighting several directions for future research on this topic.

0.45
9

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-27 ·Roy Gabriel, Nattakorn Kittisut, Jamshid Hassanpour, Michael Galarnyk, Abanoub Abdelmalak +4 more
Abstract

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

0.45
10

Lowering the Barrier to AI-Driven Inspection: A No-Code Workflow for Automated Structural Defect Detection

cs.CV cs.LGeess.IV ·2026-08-25 ·Michael Holm, Tanner McElroy, Xinghang Zhang, Guang Lin
publishedcode/data
Abstract · 11 pages, 7 figures. Accepted to ASME SMASIS 2026 (paper SMASIS2026-190654). Software available at https://github.com/michaelholm6/YOLOEZ

Structural health monitoring (SHM) is essential in modern engineering, providing data for condition-based maintenance, lifecycle assessment, and predictive decision-making. Traditionally, SHM relied on visual inspection to detect defects such as cracks and deformations. Early computer vision (CV) methods, including thresholding, edge detection, and handcrafted features, aimed to automate this process but were highly sensitive to noise, imaging variations, and multiscale defects, limiting their reliability. Recent advances in machine learning, particularly convolutional neural networks (CNNs) and You Only Look Once (YOLO), have improved defect detection accuracy and enabled real-time analysis. However, adoption in SHM remains limited due to technical barriers such as data labeling, model training, and deployment, which typically require programming expertise. To address this gap, we introduce YOLOEZ, an open-source, GUI-based tool for end-to-end YOLO model application. YOLOEZ integrates data labeling, training, and inference into a single interface, enabling high-performance model development without code while supporting reproducible workflows. Evaluation against existing software and classical image processing demonstrates that YOLOEZ not only outperforms traditional methods across most detection metrics, but also lowers adoption barriers present in other modern CV tools. By combining accuracy with accessibility, YOLOEZ facilitates wider use of AI-driven monitoring for predictive maintenance, digital twins, and intelligent structural systems.

0.42
11

Ada-TokenCom: Rate-Adaptive Token Communications via Large-Model-Driven Token Compression and Generation

cs.IT cs.CVeess.IV ·2026-08-28 ·Zijun Zhang, Li Qiao, Mahdi Boloursaz Mashhadi, Zhen Gao, Mehdi Bennis +1 more
Abstract

Token Communications (TokenCom) has recently emerged as a new paradigm in which tokens serve as unified units for communication and computation, enabling efficient multimodal semantic and goal-oriented transmission. In this paper, we develop Ada-TokenCom, a rate-adaptive TokenCom framework based on large autoregressive models, which integrates next-token prediction with arithmetic coding to achieve ultra-low bitrate semantic communication at the token level. We propose a mixed reconstruction/generation scheme, where the transmitter encodes and transmits the highly informative tokens at the beginning of the token sequence leveraging a pre-trained autoregressive large model, while the receiver uses an identical model to predict the rest. Moreover, we design a Lyapunov-based algorithm to dynamically optimize both the source compression rate and the modulation and coding scheme, adapting to time-varying network conditions. Simulation results demonstrate that our proposed Ada-TokenCom framework outperforms both digital and deep joint source-channel coding-based semantic communication baselines.

0.42
12

Knowledge Distillation Driven Semantic NOMA with GAN Refinement for 6G Robotic Vehicle Networks

cs.IT cs.CVeess.IV ·2026-08-27 ·Qifei Wang, Zhen Gao, Li Qiao, Ziwei Wan, De Mi +2 more
published
Abstract · Presented at IEEE VTC-Spring 2026

To achieve sustainable intelligent mobility, 6G-empowered robotic vehicles (RVs) require high-fidelity visual perception under stringent bandwidth and energy constraints. Semantic communication offers a spectral-efficient solution but suffers from severe interference in uplink non-orthogonal multiple access (NOMA) RV networks. To address this, we propose a knowledge distillation-driven and generative models-enhanced NOMA framework for robust and green RV communications, named KDG-SemNOMA. First, we develop a ConvNeXt-based deep joint source-channel coding (DeepJSCC) architecture with an enhanced attention feature (AF) module for dynamic channel adaptation. Second, to mitigate interference without inference overhead, an orthogonal transmission teacher model guides the NOMA student model via a two-stage knowledge distillation strategy. Finally, to address the over-smoothing artifacts of pixel-wise optimization, we introduce a channel-conditional GAN (cGAN). By explicitly taking the Stage-I initial reconstruction and channel states as conditional inputs, this module refines coarse outputs into high-fidelity images with realistic textures. Experiments on FFHQ-256 demonstrate that KDG-SemNOMA significantly outperforms state-of-the-art methods in both pixel-level accuracy and perceptual fidelity.

0.41
13

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40
14

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38
15

Unified-protocol voxel-level pulmonary embolism annotations for three public CT angiography datasets

eess.IV cs.CV ·2026-08-25 ·Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang +4 more
Abstract · 18 pages, 5 figures, 1 table

Reliable clot-volume quantification and subsequent risk assessment in pulmonary embolism depend on precise segmentation of emboli on computed tomography pulmonary angiography. Deep learning models for this task must be trained on accurate voxel-level labels. The three public datasets that provide such labels were annotated under different protocols, and some of their studies contain unlabeled emboli or labels that are discontinuous across slices. This Data Descriptor presents voxel-level pulmonary embolism annotations for 149 of the 166 studies in these datasets. A primary rater drew all annotations under a single protocol. A thoracic radiologist with more than 20 years of experience reviewed and revised them. Three raters at three different centers independently annotated a subset of 15 studies. The subset was selected by source dataset and embolus location. Technical validation quantifies volumetric agreement with the source annotations, changes in within-mask attenuation, and inter-rater agreement on the subset. The dataset is intended to allow segmentation models to be developed and compared under a common reference standard.

0.37
16

Lossy Event Compression: From Event Stream Distortion to Task Performance

cs.CV eess.IV ·2026-08-28 ·Zahra Rezaee, Catarina Brites, João Ascenso
published
Abstract

Event cameras generate asynchronous, sparse data streams with microsecond temporal resolution, but in moderate-to-high motion scenes they can produce as many as hundreds of millions of events per second, creating significant bandwidth and storage challenges. Lossy compression is therefore essential for practical deployment, yet existing event stream distortion metrics fail to reliably predict compression-induced degradation at the task level, forcing codec optimization to rely on expensive task-specific evaluations. To address this gap, this paper introduces two fundamentally different event compression pipelines: i) an aggregation-based pipeline that converts the event stream into polarity-based histogram frames for compression with the conventional image codec JPEG 2000, and ii) a frame-free point cloud-based pipeline that codes events natively as 3D points using the octree-based codec G-PCC. Both pipelines are then assessed within a unified task-driven evaluation framework that relates event stream distortion to downstream application performance across four representative tasks: i) video reconstruction, ii) object detection, iii) optical flow estimation, and a delay-sensitive task iv) asynchronous feature tracking under a reference-relative protocol. Building on this framework, five classification-based distortion metrics are applied to event compression for the first time, to the best of the authors' knowledge, and benchmarked against existing event stream metrics. Experimental results demonstrate that the proposed metrics reliably predict compression-induced task degradation across different coding frameworks. This demonstrates that event stream distortion assessment can be an efficient alternative to repeated task-specific evaluation, providing direct guidance for the development and optimization of future event data coding solutions.

0.35
17

Spatiotemporal Distillation via Recurrent Bottlenecks for Aortic Tracking

eess.IV cs.CVcs.LG ·2026-08-24 ·Dexter Wen Jie Teo, Nairouz Shehata, Herve Lombaert
published
Abstract · Accepted at the 17th Statistical Atlases and Computational Models of the Heart (STACOM) Workshop, MICCAI 2026. Springer LNCS

Cardiac cine-MRI serves as a direct visual indicator of cardiovascular hemodynamics by capturing the continuous wall motion of the aorta. Quantifying these dynamic structural changes across the cardiac cycle is essential for measuring aortic distensibility, a primary marker of arterial stiffness. However, standard 2D segmentation networks focus on each frame independently. Consequently, when rapid systolic flow temporarily obscures the aorta's boundaries, this lack of continuous context results in frame-to-frame tracking dropouts and boundary inconsistencies. Spatiotemporal ($2\text{D}+t$) networks can enforce temporal consistency across the sequence but suffer from a scarcity of expert annotations. To address this, we present a semi-supervised spatiotemporal ($2\text{D}$ to $2\text{D}+t$) knowledge distillation framework exploiting the cardiac cycle. The framework distills a spatial teacher's expertise into a spatiotemporal student network by executing a dynamic latent interception, pairing a recurrent spatiotemporal bottleneck with a residual spatial bypass. Our model selection strategy applies a baseline validation threshold ($\text{DSC} \ge 0.50$) prior to selecting the epoch that maximizes anatomical consistency. This strategy enables the spatiotemporal student model to achieve superior surface tracking accuracy ($\text{NSD@1mm} = 92.3\% \pm 0.2\%$) and high structural reliability ($\text{Frac}_{2\text{CC}} = 99.2\% \pm 0.6\%$), reducing population-wide structural anomalies by over 56\% compared to a 2D nnU-Net baseline.

0.34
18

Enhancing MRI Brain Tumor Edge Detection: A Hybrid Preprocessing Approach Utilizing CLAHE

eess.IV cs.CV ·2026-08-27 ·Shahid-E-Kaiser Md. Tashrif, Munshi Md Arafat Hussain, Sheikh Nahian, Sumaiya Islam
benchmarkhot direction
Abstract · 14 pages, 3 figures. In review at IntSym 2026, South Eastern University of Sri Lanka

Accurate boundary delineation of brain tumors in Magnetic Resonance Imaging (MRI) is a critical yet formidable challenge in neuro-oncology due to inherent scanner noise, complex anatomical structures, and uneven illumination. Traditional edge detection algorithms, while computationally lightweight and mathematically interpretable, frequently fail to capture the diffuse, localized boundaries of edema when relying solely on global preprocessing and manual parameter tuning. To overcome these limitations, we propose a hybrid automated edge detection pipeline. Our approach integrates an optimally configured Contrast-Limited Adaptive Histogram Equalization (CLAHE) layer into a comprehensive morphological preprocessing framework, followed by a deterministic sequential parameter sweep to fully automate threshold selection. The proposed hybrid model demonstrated enhancement in detecting critical anatomical structures in a publicly available benchmark database from Kaggle. By intelligently amplifying localized gradients without overwhelming the image with background noise, our method achieved higher Recall (Sensitivity). Consequently, the overall F1-Score elevated, and the Structural Similarity Index (SSIM) improved, all while maintaining a highly efficient execution. This establishes our optimized pipeline as a highly practical and near real-time operational model for clinical diagnostics, offering a compelling alternative to computationally heavy deep learning approaches.

0.34
19

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

eess.IV eess.SP ·2026-08-28 ·Xuan Lei, Philip Schniter, Juliet Varghese, Rizwan Ahmad
Abstract

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusion posterior sampling for data consistency. CineDiff was evaluated in four settings: (i) 30 retrospectively undersampled breath-held cine at 1.5T and 3T from healthy participants across multiple acceleration rates, (ii) 15 prospectively undersampled free-breathing RT cine at 1.5T and 3T from patients indicated for clinical CMR, and (iii) 10 prospectively undersampled mid-field (0.55T) free-breathing scans, including five from healthy subjects and five from porcine models. For retrospective undersampling, reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). For prospective undersampling, image quality was evaluated by blinded expert scoring on a 5-point Likert scale. Results: In retrospectively undersampled breath-held cine data, CineDiff achieved higher PSNR and SSIM and lower LPIPS and DISTS than the comparison methods across all evaluated acceleration rates. In prospectively undersampled free-breathing RT cine data, CineDiff received higher expert image-quality scores. Qualitatively, CineDiff reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN. Conclusion: CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR. The method also demonstrated robustness to out-of-distribution data, including mid-field and porcine acquisitions.

0.33
20

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

eess.IV cs.CV ·2026-08-28 ·Yuang Wang, Shuo Wang, Changyu Chen, Dufan Wu, Pengfei Jin +10 more
hot direction
Abstract · 12 pages, 7 figures. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after w…

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

0.33
21

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

eess.IV cs.CV ·2026-08-24 ·Dexter Wen Jie Teo, Kumaradevan Punithakumar
published
Abstract · Accepted at the SWITCH+ Workshop (ISLES 2026 Challenge), MICCAI 2026. Springer LNCS

Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ($\le 7$ days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L ($k=5$) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630)

0.31
22

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

cs.CV eess.IV ·2026-08-27 ·Yuzhe Zhao
benchmark
Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

0.31
23

DP-JMRNet: A Deep Unfolding Network for Differential Phase Preservation in Sparse Bitemporal SAR Reconstruction

eess.SP eess.IV ·2026-08-27 ·Juncheng Bao, Zhen Zhang, George P. Petropoulos
code/data
Abstract

Complex SAR imagery is usually visualized and evaluated mainly through its magnitude. Phase is retained in the complex data but is rarely treated as a direct image-quality objective. Existing sparse reconstruction methods typically focus on magnitude fidelity and single-epoch complex reconstruction accuracy. However, the phase difference between two acquisitions is what drives line-of-sight deformation retrieval in InSAR, from ground subsidence monitoring to earthquake deformation mapping. This paper proposes the Differential-Phase-Oriented Joint Masked Reconstruction Network (DP-JMRNet), which uses deep unfolding to reconstruct the two epochs jointly from masked observations under a differential-phase objective. An exchange-equivariant interaction module makes the reconstruction independent of epoch ordering. A coherence-aware gate opens cross-epoch sharing in coherent regions and closes it where the two epochs disagree. On simulated bitemporal SAR data, DP-JMRNet attains the lowest differential-phase RMSE at 30\%, 40\%, and 50\% sampling rate, while maintaining competitive amplitude and complex-image fidelity. This corresponds to a 47.5\%--51.3\% reduction over the best baseline, achieved with one third of its parameters. The same trend is validated on three Sentinel-1 scenes. A systematic study of acquisition design further shows that sharing the same aperture support across epochs is necessary for phase fidelity, whereas optimizing the sampling mask does not improve the differential phase. The code and data are available at https://github.com/JasonBao05/coherent-sar-unfolding.

0.28
24

DairySocialTwin: Auditing the video-to-graph evidence chain in cattle social networks

cs.SI cs.AIeess.IVq-bio.QM ·2026-08-24 ·Yiwen Huang, Suresh Raja Neethirajan
Abstract · 28 pages, 6 figures, 4 tables

Video-derived social graphs can appear precise while inheriting uncertainty from detection, tracking, classification, and aggregation. We present DairySocialTwin, a graph-centered audit framework applied to 203 videos (122 h 23 min) from 15 views at three commercial dairy farms. Curation retained 447 of 839 candidate clips; 400 entered a frozen source-clip index, including 71 legacy clips with unavailable farm and time metadata. Five models were compared on a development split, with an NRI-style model retained as an exploratory trade-off between class balance and dyadic output. In a 90-min manual audit, reconciliation improved switches, fragmentation, and continuous-track duration across three gap definitions, but constrained identity capacity and inherited detector errors limited claims of identity accuracy. Matched manual and reconciled summaries showed coarse agreement and assignment sensitivity. Camera-specific semantics, observation opportunity, and identity-summary-to-video trace-back made these dependencies inspectable. DairySocialTwin supports auditable relational inference without claiming permanent identity, calibrated behavior, or biological diagnosis.

0.28
25

An Energy-Proportional Multimodal and Context-Aware Vision IoT Node

eess.IV ·2026-08-24 ·Julian Moosmann, Philipp Mayer, Luca Benini, Michele Magno
published
Abstract

While recent advancements in TinyML have significantly reduced the computational complexity of on-device vision pipelines, image acquisition remains a dominant contributor to system-level energy consumption and memory footprint. In vision-enabled IoT platforms, the image sensor consumes energy comparable to the inference engine, thereby offsetting algorithmic efficiency gains. Consequently, current designs face a fundamental trade-off: continuous and always-on sensing incurs prohibitive energy consumption, whereas aggressive duty cycling increases latency and risks missing transient events. This work presents an energy-proportional, context-aware vision IoT node that addresses this challenge through a heterogeneous multimodal dual-camera architecture. Detection and recognition are decoupled by combining an event-based imager operating asynchronously in an energy-efficient always-on wake-on-motion mode together with an RGB imager. Deployed on a low-power microcontroller, a novel TinyissimoYOLOv12 is introduced for efficient and accurate object detection. By activating the high-power image acquisition and processing stages only upon sparse visual triggers, the proposed architecture improves efficiency and latency, eliminating redundant sensing while maintaining continuous monitoring coverage. Experimental results demonstrate an energy consumption of only 222$μ$Wh. Upon a motion trigger, the system completes a full sense-to-report cycle-RGB acquisition, object detection across 80 classes, and LoRa telemetry-with a total energy consumption of 28.7mJ. The network achieves up to 32.3% mAP with a model size of 1 million parameters. At a 1% daily activity ratio, the platform achieves a three-month operational lifetime with a 1.85Wh battery, enabling always-on visual monitoring in a place-and-forget scenario through autonomous edge intelligence.

0.28
26

Score-Based Ideal Observer Approximation via Denoising Score Matching for Signal-Known-Exactly Detection Tasks

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-25 ·Weimin Zhou
theoryunusual
Abstract · Submitted to SPIE Medical Imaging 2027

The Bayesian Ideal Observer (IO) establishes the theoretical upper bound on task performance for binary detection tasks. However, analytical computation of the IO test statistic is generally intractable. Numerical approaches based on Markov-chain Monte Carlo (MCMC) methods, including their recent deep generative model-based extensions, typically require extensive posterior sampling for each test image. Supervised learning has also been investigated to approximate the IO performance. However, such methods are typically trained for a specific detection task and signal and may require retraining when the task or signal changes. The score function, defined as the gradient of the log probability density, encodes the local geometry of the data distribution and is a fundamental quantity in modern score-based generative modeling. This work reformulates the IO test statistic in terms of the score function and introduces a score-based ideal observer (SIO). The proposed SIO uses a denoising convolutional neural network trained exclusively on signal-absent images to estimate the signal-absent score function. Once trained, the resulting score model can be used to approximate the IO test statistic for detection tasks involving arbitrary additive signals, without per-image posterior sampling or signal-specific retraining. Numerical studies consider a signal-known-exactly (SKE) detection task with a stochastic lumpy-background model. The results demonstrate that the proposed SIO can closely approximate the IO performance.

0.25
27

Efficient JPEG Restoration in the Wavelet Domain via Mean Flows

eess.IV cs.CV ·2026-08-28 ·Stefan-Alexandru Asandei, Mihai-Alexandru Radu
Abstract · 9 pages, 2 figures, 6 tables. Code will be released soon

Latest JPEG restoration systems achieve strong quality with large models, yet often remain too slow and expensive for efficient on-device deployment. We present a 65M-parameter generative restorer that attains the lowest LPIPS at QF 10 and 20 on LIVE-1, Urban100, and DIV2K-val while sustaining 8.05 images/s at $1024\times1024$ on a single RTX 3090, roughly $4.9\times$ the reported throughput of one-step SODiff at one-twentieth of its parameters. Trained from scratch, the model replaces the learned VAE encoder-decoder with an exactly invertible two-level Haar transform, predicts a clean wavelet-domain residual through a rank-enhanced linear-attention DiT that estimates compression severity internally, and is optimized with an improved MeanFlow objective that enables inference in one or two network evaluations without distillation. Large pretrained priors remain stronger under severe compression (QF 5), whereas our model prioritizes throughput for deployment-constrained restoration.

0.25
28

Feature-Spectral Fragility in Segmentation: Dataset Dependence, Architecture-Specific Localization, and Spectral Correlates

cs.CV eess.IV ·2026-08-29 ·Subhash Kashyap
Abstract · 4 pages, 3 figures

Robustness of segmentation models is commonly assessed through input-domain perturbations, while dependence on frequency content within learned feature representations remains less understood. We probe this dependence using targeted post-training low-pass interventions on internal representations of three segmentation architectures, ResNet50-UNet (CNN), VM-UNet (SSM), and Swin-UNETR (Transformer), across CVC-ClinicDB and ISIC2018, with headline evaluations performed on untouched held-out test sets. At cutoff $ρ=0.25$, feature-domain low-pass filtering causes severe degradation on CVC: Dice drops by 100%, 73.2%, and 30.9% for CNN, SSM, and Transformer, respectively, compared with 9.4%, 10.3%, and 0.6% on ISIC. The cross-dataset difference is statistically significant for every architecture. Single-stage interventions further show that the most sensitive stage depends on architecture and dataset: the CNN peaks at the 2nd to 3rd encoder block, whereas the SSM peaks at the 1st to 2nd encoder stage. Native feature-domain spectral measurements show an inverse association between high-frequency energy and fragility on CVC; the relationship is only partial on ISIC and is therefore treated as a candidate correlate rather than a proven mechanism. Finally, Fourier augmentation improves robustness to input-space low-pass filtering but leaves feature-domain degradation essentially unchanged. These results show that feature-spectral robustness is strongly dataset-dependent, architecture-specific, and distinct from input-domain spectral robustness.

0.25
29

Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation

cs.CV eess.IV ·2026-08-29 ·Shraddha Changune, Vivek Noel Soren, Gautam Das, Tapan Kumar Gandhi
published
Abstract · Accepted at 15th International Conference on Image Processing Theory, Tools and Applications 2026

Optic disc (OD) segmentation is essential for diagnosing ophthalmic pathologies from retinal fundus images. However, prevailing deep learning approaches operate as opaque black boxes, lacking the inference-stage mathematical traceability--a critical requirement for algorithmic auditing and failure analysis in clinical workflows. This paper presents a fully algorithmically traceable and trainable segmentation pipeline that jointly combines superpixel decomposition, hybrid brightness-proximity superpixel scoring, morphological regularization, iterative GrabCut refinement, and elliptical shape fitting. The hyperparameter optimization is formulated as an objective function and solved via Bayesian optimization to eliminate manual parameter tuning. A quantitative evaluation on the Drishti-GS dataset demonstrates that our method achieves a Dice coefficient of 0.9536, matching state-of-the-art performance. By maintaining explicit mathematical transparency across all processing stages, our framework offers a deterministic, traceable alternative to black-box architectures for medical review and debugging.

0.23
30

Destroy Me: Automatic Artifact Generation for Histopathology Images

eess.IV cs.AIcs.CVcs.LG ·2026-08-27 ·Zuzanna Krawczyk-Borysiak, Adam Krawczyk, Mateusz Miller, Gabriela Kaczmarek, Sławomir Pakuło +2 more
Abstract

Deep learning's diagnostic utility in pathology is constrained by model vulnerability to real-world data imperfections. While current strategies favor "perfect data" by filtering low-quality regions, which can lead to the loss of valuable diagnostic context, we propose a paradigm shift: engineering models to thrive in imperfect environments using "Destroy Me", a hybrid framework for realistic artifact synthesis and robust data augmentation. Our approach combines Stable Diffusion, fine-tuned to preserve morphological continuity by realistically integrating artifacts with the underlying tissue architecture, with physics-based procedural modeling to synthesize six common artifact types: tissue folds, precipitates, blur, stitching errors, dust, and pen markers. Artifact fidelity is assessed using Kernel Inception Distance (KID) and color Wasserstein distance metrics. Validating this strategy on lung adenocarcinoma pattern classification with an nnU-Net, we confirm that models trained on "destroyed" patches consistently outperform baselines on independent real-world datasets. Specifically, we observed a 10.5% relative improvement in macro F1-score and a 15% relative increase in the Cohen's Kappa ($κ$) coefficient. Crucially, our results demonstrate that selective, impact-weighted augmentation is vital for balancing practical robustness with the preservation of subtle diagnostic features.

0.23
31

Multi-Stage Prompt-Guided Feature Modulation for Generalizable Brain Tumor Segmentation

eess.IV cs.CV ·2026-08-24 ·Mohammad Mahdi Danesh Pajouh, Sara Saeedi
published
Abstract · Accepted to BraTS MICCAI 2026 Task 3 (Generalizability Across Tumors)

Accurate brain tumor segmentation from magnetic resonance imaging (MRI) is essential for diagnosis, treatment planning, surgical guidance, and disease monitoring. However, developing automated segmentation models that generalize across diverse tumor characteristics, imaging protocols, acquisition sites, and patient populations remains challenging. Variations in tumor morphology and imaging distributions can substantially degrade performance outside the training domain. Consequently, improving the robustness and generalization of deep learning-based segmentation models has become a key objective in medical image analysis. To improve segmentation robustness, we propose Multi-Stage Dynamic Prompt nnU-Net, a prompt-conditioned extension of nnU-Net. Three independent dynamic prompt modules are inserted into the deepest encoder stages. Each module contains a learnable bank of ten 256-dimensional prompt vectors and uses globally pooled encoder features to generate image-specific prompt representations. These representations are projected into feature-wise scaling $(γ)$ and shifting $(β)$ parameters that modulate encoder feature maps through Feature-wise Linear Modulation (FiLM), enabling adaptive feature conditioning at multiple semantic levels. Evaluation on the BraTS GOAT validation dataset demonstrated that the proposed Multi-Stage Dynamic Prompt nnU-Net outperformed the baseline nnU Net across the majority of evaluated metrics and tumor subregions. The proposed model achieved average lesion-wise Dice scores of 76.16% (ET), 80.04% (TC), and 86.42% (WT), compared with 74.38%, 78.14% and 84.01% for the baseline model. The results demonstrate that multi-stage dynamic prompt conditioning improves segmentation accuracy and boundary delineation for brain tumor segmentation.

0.21
32

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

eess.IV cs.CV ·2026-08-28 ·Dat Tat Mai, Thai Viet Pham, Thu Nguyen Thi Dang, James Jin Kang
Abstract

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

0.21
33

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

eess.IV cs.CV ·2026-08-27 ·Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
benchmark
Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

0.21
34

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

eess.IV ·2026-08-28 ·Jin Yang, Tian Liu, Jing Wang, Sooyun Caroline Tavolacci, Benjamin Tran +5 more
Abstract · 28 pages, 9 figures, 5 tables

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

0.19
35

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Neeraja Ramanan
Abstract

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

0.13
36

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors

eess.IV ·2026-08-29 ·Hengjia Ran, Jie Luo, Yutao Zhu, Rui Hu, Fenglin Zhan +3 more
Abstract

Image reconstruction for positron emission tomography (PET) is an ill-posed Poisson inverse problem. In this work, we introduce an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior. We train the generative model on high-quality PET images to learn a differentiable ordinary differential equation (ODE)-based transport from a Gaussian latent distribution to the PET image distribution. We incorporate this generator as an explicit manifold constraint into a regularized Poisson likelihood formulation. To solve the resulting problem, we develop an alternating direction method of multipliers (ADMM) algorithm that integrates an expectation-maximization (EM)-type surrogate update for Poisson data fidelity with gradient-based latent-space optimization. Numerical simulations and in vivo PET experiments demonstrate improved reconstruction accuracy compared with conventional reconstruction methods and recent deep learning-based approaches, particularly in low-count settings, with competitive computational efficiency.

0.07