CS Paper Radar

Weekly top 100 · eess.IV

2026-W42 Oct 12 – Oct 18, 2026

Ranked from 5,357 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Codec-Compatible Learned Compression for 3D Gaussian Splatting

eess.IV cs.CV ·2026-10-17 ·Feiyang Yu, Qi Yang, Wenjie Huang, Yunfeng Guan, Yiling Xu +1 more
published
Abstract · Accepted at the IEEE International Conference on Visual Communications and Image Processing (VCIP 2026). 5 pages, 3 figures, and 1 table

Video-based 3D Gaussian Splatting (3DGS) compression methods provide a practical route by representing Gaussian attributes as 2D maps and coding them with standard video codecs. Among these maps, high-dimensional non-DC spherical harmonics (SH-AC) maps contain the largest number of channels and account for a dominant portion of the bitstream. However, their statistics differ substantially from those of natural images, and the nonlinear dependencies among SH-AC coefficients remain insufficiently exploited. To address these issues, we propose CCT-GS, a Codec-Compatible learned Transform framework for 3DGS compression. CCT-GS first learns a generalized SH-AC transform that captures cross-scene regularities and converts SH-AC maps into compact codec-friendly bottleneck maps. It further introduces LoRA-based scene adaptation to recover scene-specific appearance details with lightweight side information. Experiments on MPEG GSC sequences demonstrate that CCT-GS consistently outperforms representative video-based baselines, achieving an average BD-rate reduction of 51.30% over the video-based anchor.

0.54
2

LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

eess.IV cs.CV ·2026-10-16 ·Damian Rynczak, Marek Wodzinski
hot direction
Abstract · 13 pages, 7 figures, 3 tables

Implicit neural representations (INRs) have been applied to deformable image registration, where a lightweight network maps a spatial coordinate to a deformation vector. Because an INR encodes one specific signal in its parameters, a fresh network must be optimized for every image pair at test time, which is slow. Existing methods reduce this cost by meta-learning an initialization across a population of image pairs, and condition the weights of the INR globally, so the same conditioning applies at every coordinate while the deformation field it initializes varies across the domain. We propose LUMINR, a meta-learning framework that accelerates this per-pair fitting and in which the conditioning is local instead. LUMINR uses an INR that maps a coordinate, together with local intensity and gradient features, to a deformation vector, so the conditioning varies over the domain at the resolution of the field being modelled. Its objective is to find an initialization of the INR parameters from which the network can be fine-tuned to register any unseen pair in only a few optimization iterations. We evaluate LUMINR on 3D deformable registration of brain MRI from the OASIS dataset, where local conditioning and the meta-learned initialization prove complementary: early in fitting they reach a markedly higher accuracy than either does alone. Fine-tuned from that initialization, LUMINR matches the accuracy of the same conditioned INR fit from scratch in roughly a tenth of the gradient steps and a tenth of the wall-clock time, while the deformation fields stay smooth with negligible folding.

0.50
3

Simplifying and Improving On-Policy Distillation for Few-Step Diffusion

cs.CV cs.LGeess.IV ·2026-10-13 ·Jiawei Zhang, Ziyu Wan, Nanye Ma, Long Zhao, Dong Chen +3 more
code/datacommunity pick
Abstract · Project Page: https://zjwfufu.github.io/SMD-Page/

Few-step distillation reduces the sampling cost of diffusion and flow models, but existing approaches often require auxiliary score models or specialized architectures. We show that simple on-policy velocity regression already provides a strong foundation for 4-NFE generation. To represent teacher velocity variation within each coarse transition, we introduce Pivot, a training-only residual proxy that separates local corrections from the student's interval-mean prediction. We further repel the student from weaker teacher predictions, providing a lightweight mechanism for avoiding undesirable modes. The resulting framework, Simplified Matching Distillation (SMD), remains entirely regression-based, requires neither online score estimation nor adversarial training, and leaves the deployed generator unchanged. We evaluate SMD on image generation and editing, 3D generation, video synthesis, and joint audio--video generation, scaling to 33 billion parameters. At 4-NFE, SMD outperforms strong few-step baselines and surpasses multi-step teachers on several benchmarks. It also supports cross-model, multi-teacher, and causal-video distillation.

0.49
4

Monotone Piecewise-Linear Harmonization of Multitemporal Multispectral Surface Reflectance With Unsupervised Deep Multiview Pseudoinvariant Features Learning

eess.IV cs.CV ·2026-10-15 ·Lino Garda Denaro, Chia-Hsiang Lin
Abstract · 15 pages, 5 figures

Surface reflectance products derived from optical satellite may exhibit systematic inconsistencies across acquisition dates, because atmospheric correction is generally performed independently for each image. Such residual biases distort the temporal behavior of invariant ground targets and reduce the reliability of multitemporal surface reflectance analysis. This study proposes Deep Multitemporal Generalized Canonical Correlation Analysis (DeepMGCCA), an unsupervised deep multiview pseudoinvariant feature learning framework that integrates Deep Generalized Canonical Correlation Analysis (GCCA) with Multivariate Alteration Detection (MAD) to identify deep-pseudoinvariant features (DIFs) for the removal of surface reflectance biases across multitemporal satellite observations. Unlike conventional MAD-based approaches that rely on linear GCCA, the proposed framework replaces date-specific linear projections with a shared convolutional encoder. The framework learns deep invariant features (DIFs) directly from pixel-weighted canonical variates via iterative reweighting strategy, while a reconstruction regularizer preserves surface reflectance information and prevents degenerate collapse from suppressing genuine temporal variability. Experiments were conducted on four annual Landsat-8/9 and Sentinel-2 acquisitions across four regions of interest (ROIs) to evaluate four DIF-based harmonization transforms. A monotone piecewise-linear transform derived from DIFs quantiles consistently achieved the largest bias reduction, lowering the between-date spectral angle by up to 2.54 and RMSE by 0.015, and raising PSNR by up to 4.04~dB. These findings demonstrate the potential of deep invariant feature learning for multitemporal surface reflectance bias removal while highlighting the importance of preserving physically meaningful temporal and spectral information during nonlinear representation learning.

0.47
5

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions

eess.IV ·2026-10-15 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
Abstract · 8 pages, 4 figures

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

0.47
6

Case-Specific Priors-Guided Multimodal Fusion for Prognosis Prediction in Head and Neck Cancer

eess.IV ·2026-10-15 ·Yue Lin, Shuchang Ye, Shenghai Wu, Dashun Zheng, Mingyuan Meng
top venuecode/data
Abstract · Accepted at MICCAI 2026

Accurate prognosis prediction for head and neck cancer typically necessitates integrating highly heterogeneous clinical and pathological evidence by sophisticated multimodal fusion. However, existing fusion techniques are usually grounded in case-generic clinical rationales about complementary synergies across modalities, underestimating case-specific variance. In this study, we propose a prognosis prediction framework that explicitly incorporates Case-specific Priors to guide Multimodal fusion (named CPM). It leverages broad medical knowledge of LLMs to characterize each case's (case-specific) intra-modal contexts and inter-modal relations, as well as case-generic multimodal rationale, as priors, enabling three-stage priors-guided multimodal fusion: (i) Intra-modal Context-guided Calibration (IntraCC) that leverages case-specific intra-modal priors to guide feature calibration within each modality; (ii) Inter-modal Relation-guided Interaction (InterRI) that leverages case-specific inter-modal priors to guide pair-wise feature interaction in modality pairs; and (iii) Multimodal Rationale-guided Aggregation (MultiRA) that leverages case-generic multimodal priors to guide final feature aggregation over all modalities. On the well-established HANCOCK challenge dataset involving four distinct medical modalities, our CPM achieved a mean AUC of 83.98% for predicting 5-year overall survival and 2-year recurrence-free survival, improving upon the baseline by 7.58%, pioneeringly demonstrating the effectiveness of LLM-derived medical priors in guiding multimodal fusion for prognosis prediction. The code is available at https://github.com/yuelin421/CPM.

0.46
7

Deficit-Driven Stratified Acquisition for Building STRATA-S12: An Open SAR-Optical Corpus for Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-10-13 ·Christian Sanchez-Leon, Dongming Chen, Dongqi Wang
Abstract · v3: substantially revised. The ordering analysis is now a replay over all 2,928,370 real acquisition attempts (deficit-driven vs. round-robi…

Building a co-registered SAR-optical corpus for self-supervised Earth Observation is above all an acquisition problem, yet the main multi-modal datasets are collected opportunistically, with no per-stratum quota control, so the regions and seasons that cloud cover hits hardest end up under-sampled. We present Deficit-Driven Stratified Acquisition (DDSA), an algorithm that casts the construction of a Sentinel-1/Sentinel-2 corpus as a constrained maximum-coverage problem over a land-cover-driven, hemisphere-corrected (class x season x region) stratification of target countries on all six inhabited continents, and solves it online: acquisition is ordered by marginal gain against a per-stratum deficit that the quality gates and a visual review of every accepted pair keep updating during the run. Three results follow from measuring the algorithm on its own product. First, stratum balance is a property of the deficit-driven ordering rather than of run length: replayed over all 2,928,370 real acquisition attempts, failures included, it populates all 192 strata within 0.05% of the attempts, against 4.03% for uniform round-robin effort and 20.5% for a random order. Second, whether a rejected attempt can be recovered is better predicted by how long its cause persists than by the type of defect: cloud rejections are recovered at eta = 18.8% against 41.4% for nodata, consistent with clouds persisting through a season. Third, the repair loop supplies 39.5% of the released pairs at no measurable quality cost, with 89.8% surviving manual review, but it adds yield rather than balance. The quality guarantee has a price: 2,928,370 acquisition attempts produced 740,746 released pairs. We release the corpus, STRATA-S12, with per-pair metadata sidecars aligned with the STAC and PDS4 standards and the FAIR principles, and a pre-registered linear probe confirms it is fit for self-supervised pre-training.

0.45
8

Deep Learning for Atmospheric Turbulence Mitigation: A Comparison Between GANs and Transformers

eess.IV cs.CV ·2026-10-13 ·Juan S. Carrillo, Jérôme Gilles
publishedhot direction
Abstract · Published in the Journal of Electronic Imaging

Atmospheric turbulence creates complex spatial and temporal distortions that significantly reduce image quality. This work compares two deep learning methods for turbulence reduction: Generative Adversarial Networks (GANs) and Transformer-based models. Both methods are trained and tested on the SOTIS dataset, which includes multi-frame sequences under different turbulence conditions with ground truth references. Our results show an important finding: GAN-based models perform better in severely degraded, low-quality situations, while Transformer-based models achieve better results in moderate to high-quality settings, especially in correcting geometric distortions. We also enhance the Turbulence Mitigation Transformer (TMT) by introducing a refined training strategy, an augmented input design that includes a temporally averaged frame as prior structural information, and a modified loss function that incorporates the Structural Similarity Index (SSIM). These improvements lead to consistent performance gains across various turbulence conditions. Overall, this study provides an in-depth evaluation of deep learning methods for turbulence reduction and offers practical guidance for selecting models in different imaging environments.

0.44
9

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

eess.IV cs.CVq-bio.TO ·2026-10-12 ·Quan Wang
benchmarkcode/data
Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

0.37
10

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37
11

Severity-Channel Conditioning: An Injection-Level Study for Consumer-Device Deblurring

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-17 ·Abdullah Al Shafi, Kazi Saeed Alam, Sumaiya Rahim Suma, Sk. Imran Hossain
benchmarkcode/data
Abstract · 17 pages (12 main + 5 supplementary), 7 figures, 14 tables. Code: https://github.com/C-loud-Nine/Severity-Channel-Conditioning

Motion-deblurring models lose substantial accuracy when transferred from professional cameras to smartphone-derived imagery. This paper studies whether a severity descriptor, partly derived from the paired sharp target, helps adaptation on the iPhoneBlur consumer-device benchmark. Under a shared update budget, input concatenation of a severity map is compared with global feature modulation by capture metadata, spatial feature modulation by the severity map, and a tier-contrastive output objective, together with an unconditioned spectral-loss control, all fine-tuned from the same domain-adapted latent-diffusion baseline. The primary experiment is an oracle diagnostic: target-derived information is supplied at inference. For the evaluated model pair, input concatenation improves overall peak signal-to-noise ratio from 31.23 to 31.30 dB, whereas feature modulation, the contrastive objective, and the spectral-loss control do not exceed the baseline. The gain is positive on 87.2% of test images and on 14 of 15 held-out source videos; this video-level analysis describes the evaluated checkpoint pair and does not establish robustness to retraining, and three training seeds are reported separately. The input-level gain recurs on a transformer backbone. In one exploratory run, zeroing the channel at inference retains most of the gain in peak signal-to-noise ratio but lowers structural similarity below the baseline. A normalized-step diagnostic does not support the expected larger-gradient explanation. The results characterize the evaluated configurations and do not establish injection location as the sole cause, a spatial-locality mechanism, or a reliable deployment advantage.

0.36
12

Evidence Field: Adaptive Covering Programs for Medical Imaging

eess.IV cs.AIcs.CVcs.LG ·2026-10-17 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
Abstract · 9 pages, 5 figures

Medical image classifiers typically return predictions without a native contract for independently reconstructing their spatial decision computation. Evidence Field is a trainable spatial-program architecture that jointly produces class scores, selected covering programs and signed evidence. Its encoder combines absolute and image-relative response fields with associative spatial moments and learned characteristic sums. A typed classifier scores individual regions and parent-conditioned multiplicative groups; a covering recursion selects scale, partition and composition. We establish exact one-fold coverage, optimality within the registered grammar, a bound relating smooth training to hard inference, signed-score conservation and class-centred offset invariance. Direct contractions and their adjoint specify arithmetic and storage scaling on two- and three-dimensional grids. Native output records bind inputs, parameters, supports, types and contextual dependencies to individual and ensemble predictions. In a separately reported histopathology application, patient-separated training and evaluation across held-out centres provide empirical evidence for the architecture. Trained mechanism and corrected-loss comparisons distinguish predictive effects from implementation correctness; independent readers reconstruct descriptors, routes, scores and probability mixtures. The principal contribution is a coupled representation, decision and evidence architecture whose selected computation can be reproduced independently.

0.36
13

napari-TurboBox: Interactive Multi-Viewer Bounding Box Annotation for AI-Guided Volumetric Bioimaging

eess.IV q-bio.QM ·2026-10-14 ·Nils Friederich, Philip Kohle, Maximilian Beichter, Mona Wellhäusser, Marcel Stahl +9 more
code/dataunusual
Abstract · 6 pages, 3 figures

Promptable segmentation models turn one 3D bounding box into an instance mask. Box placement therefore limits how fast microscopy volumes with thousands of objects are annotated. Each box must be checked in several synchronized viewers, but napari-bbox shares no state between viewers. An edit must update every viewer and slows down with more boxes. napari-TurboBox instead holds one shared copy of the boxes for all viewers. In a four-viewer layout, napari-TurboBox needs a few milliseconds per mouse move to update the three slice viewers up to $10^4$ boxes. The same update in napari-bbox leaves the 33 ms budget beyond about $10^3$ boxes and takes 159 ms at $10^4$. Boxes stay axis-aligned and export to COCO and YOLO as per-slice 2D boxes. napari-TurboBox is a pure-Python plugin for napari 0.6.6 to 0.9. The code is available at https://github.com/N-Friederich/napari-turbobox under the Apache 2.0 licence, and version 0.1.0 is archived at https://doi.org/10.5281/zenodo.23090828 on Zenodo.

0.35
14

Measurement-Adaptive Light-Cone Transform for Robust Non-Line-of-Sight Imaging

eess.IV cs.CV ·2026-10-16 ·Lianfang Wang, Xueying Liu, Junnan Dong, Qinghua Zhang, Jun Liu +2 more
published
Abstract

Practical non-line-of-sight (NLOS) measurements are affected by noise and deviations from idealized light transport, which can degrade reconstruction with conventional light-cone transform (LCT) methods. We propose the Measurement-Adaptive Light-Cone Transform (MALCT), a physics-guided framework that retains the efficient Fourier-domain inversion structure of LCT. {Within a unified variational formulation, MALCT combines the analytical response with a shared learned response through measurement-conditioned weighting and predicts a measurement-conditioned, frequency-dependent regularization map.} An attention-enhanced spatio-temporal feature extraction module captures long-range temporal dependencies and local spatial correlations to support reconstruction under low-signal conditions. Experiments on synthetic data and real measurements from different NLOS systems demonstrate improved reconstruction quality. Controlled evaluations further assess robustness to temporal-response broadening and reduced acquisition time. MALCT also preserves scene structures with spatial sampling grids down to $32\times32$, supporting its potential for NLOS imaging under limited acquisition budgets.

0.35
15

Image Moment Estimation for Crowded Datasets

eess.IV q-bio.QM ·2026-10-16 ·Andy Zhang, Oscar Mickelin, Amit Singer
Abstract · 29 pages, 11 figures

Single-particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of reconstructing high-resolution three-dimensional (3D) structure of biological macromolecules from a set of noisy projection images taken at random viewing directions. The mathematical model for cryo-EM images typically assumes that each image contains exactly one particle, which is centered at the origin. However, many experimental datasets contain particle images which include multiple particles: one central particle and a few crowding particles. This deviation from the model leads to inaccurate estimation of image statistics, such as the low-order image moments. To account for this, we propose a method to estimate image moments while correcting for the effect of crowding particles. This method can be run directly from a set of cryo-EM micrographs with picked particles, and we demonstrate its efficacy on a wide array of synthetic data.

0.35
16

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

eess.IV cs.CV ·2026-10-13 ·Junkai Liu, Haofan Wu, Nay Aung, Joao A. C. Lima, Steffen E. Petersen +1 more
publishedcode/data
Abstract · NeurIPS 2026. Project page: https://cardiofad.github.io/

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

0.33
17

Calibrating Generative Flows through Regional Probability Matching

eess.IV ·2026-10-12 ·Yubo Huang, Xiongyu Hu, Xin Lai, Zixi Wang, Liao Jian +2 more
benchmarkhot direction
Abstract

Generative models offer a powerful route to scientific simulation and discovery by enabling the study of complex populations and rare phenomena. Flow matching can generate realistic samples, yet inaccurate occurrence frequencies can distort population statistics and compromise inferences about rare events. Here we developed generalized mass-preserving coupled flow matching (G-MPCF), which matches the probability masses of Gaussian source regions to those of weighted data regions. This construction encodes the desired regional frequencies in the correspondence between noise and observations, shaping the learned dynamics while preserving the prescribed target distribution. On a rare-mode benchmark, G-MPCF reduces relative score error by 95.0% and numerical integration error by 89.9% compared with independent flow matching. On CIFAR-10 with a 100:1 class-probability ratio, it reduces corrected class-mass error by 44.6% compared with minibatch optimal transport, while improving mean image fidelity with matched computational budgets. We envision that incorporating regional probability calibration into generative modelling will support more reliable scientific simulation and inference, enabling the study of systems in which rare events and their occurrence frequencies are central to understanding the underlying mechanisms.

0.32
18

Really Need Recursion? Revisiting One-pass Registration with Multi-level Multi-space Contextual Guidance

eess.IV cs.AI ·2026-10-15 ·Yue Lin, Shenghai Wu, Mingyuan Meng
top venue
Abstract · Accepted at MICCAI 2026

Deformable image registration is a fundamental challenge in medical image analysis. Recent deep learning-based methods typically adopt either one-pass architectures that complete registration in a single network iteration, or recursive architectures that refine registration through multiple passes. While recursive methods often improve accuracy, they incur substantial computational overhead and slower inference speed. In this paper, we challenge the necessity of recursion for high-performance deformable registration and propose M2CG, a one-pass registration network with Multi-level Multi-space Contextual Guidance. It performs multi-step progressive pyramid registration within a single iteration, guided at each step by contextual cues from three levels (previous, current, and subsequent steps) and four spaces (image space, image feature space, segmentation space, and segmentation feature space). Our M2CG supports both unsupervised (without any labels) and semi-supervised (with segmentation labels for partial training data) registration, and has achieved state-of-the-art performance across two well-benchmarked inter-/intra-patient medical registration tasks with eight public datasets. Our findings suggest that the current reliance on recursion may stem from the absence of sufficient contextual cues that comprehensively characterize the remaining distance to the target alignment.

0.31
19

Implicit Neural Models for Direct Multi-Shell Diffusion MRI Signal Estimation

eess.IV cs.CV ·2026-10-16 ·Sanna Persson, Fabian Leander Sinzinger, Christoffer Olsson, Rodrigo Moreno
Abstract · 23 pages (9 pages main text + supplementary material), 9 figures, 18 tables

Diffusion magnetic resonance imaging is a noninvasive technique that is sensitive to the motion of water molecules in human tissue. The image signal is commonly described in q-space; however, a complete coverage of this space is often infeasible due to hardware and acquisition time limitations. In this work, we propose to represent the entire diffusion signal using an implicit neural representation network with wavelet activation functions. The signal space is encoded using Fourier features and spherical harmonics basis functions for a continuous output distribution of the raw diffusion data, enabling both super-resolution and q-space interpolation. Additionally, we introduce a pretraining strategy using a group template, enabling faster per-subject optimisation when combined with nonlinear registrations of subjects into template space. We tested the method with 10 subjects from the Human Connectome Project and 26 subjects from in-house data (multidimensional diffusion MRI from a Parkinson's disease cohort). The results show that the proposed method yields high-fidelity reconstructions with significantly reduced memory requirements compared to raw diffusion-weighted images. The pretraining scheme showed good generalisability properties on data acquired with very different protocols. We further assess the method on downstream metrics relevant to diffusion MRI data from the learned representations.

0.31
20

Augmenting Real-time Visualization in Minimally Invasive Surgery with Particle Filtering and Depth-Aware Occlusion Handling

eess.IV cs.RO ·2026-10-13 ·Anuska Sarkar, Partha Acharya, Vishnu Nandury, Kaustav Basu, Subhamoy Mandal
top venue
Abstract · Accept

We present a real-time, hybrid framework for occlusion handling and depth-aware tracking in minimally invasive surgeries (MIS). Occlusions caused by surgical instruments often obscure the region of interest (ROI), affecting surgical precision. To address this, our approach integrates enhanced You Only Look Once (YOLO) based detection, Particle Filtering (PF), and monocular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation against stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.

0.31
21

Beyond Geometric Closure: Measuring and Diagnosing Mechanical Consistency in Visual Dynamics

cs.CV eess.IV ·2026-10-17 ·Qibin Gu, Yunfeng Yan
code/data
Abstract · 34 pages, including supplementary material; 16 figures and 38 tables. Code: https://github.com/BIGPAO123321/mechanical-consistency-visual-dy…

Visual accuracy, geometric validity, and agreement with applied forces are distinct requirements for visual dynamics. We introduce a diagnostic framework that connects reaction-free SI measurements to controlled interventions on coordinate readout, training integration, and actuator response. Reference replay calibrates the measurement path, while continuous scoring exposes progress against fixed engineering targets. With three seeds per setting, we evaluate KeyCLD and CON across 343 planar assemblies at 64/256 pixels and V-JEPA + AC and LingBot-VA on 100 shared spatial test assemblies. CON reduces image MSE by 37.6%/37.2% relative to persistence, yet neither planar model attains valid native geometry. At 256 pixels, calibrated RGB replay places forecast errors far above the reference measurement floor. Exact-state KeyCLD has identical geometric pass rates under Euler and RK4 training, yet its score rises from 52.65 to 64.30 as force and energy errors decrease. In both spatial pathways, CAD/IK reconstruction restores geometry while mean actuator residuals exceed five times the engineering targets. These diagnoses distinguish coordinate correction, numerical improvement, and persistent force-response errors, guiding targeted improvements to visual dynamics.

0.30
22

FlashReFocus: Interactive Image Refocusing in Seconds

cs.CV cs.AIeess.IV ·2026-10-16 ·Ching-Heng Cheng, Chia-Ming Lee, Ming-Ching Chang, Xin Li, Yu-Lun Liu +1 more
benchmarkcode/data
Abstract · 38 pages (8 main + appendix), 47 figures, 16 tables. Project page: https://ming053l.github.io/FlashReFocus/ Code: https://github.com/ming053…

Single-image refocusing changes the focal plane and depth of field of a photograph after capture. It is inherently interactive: users try many focal points and blur strengths on one image, so each edit should be fast and change only the blur. Recent generative methods, however, rerun large diffusion models for every edit. We observe that the two sub-problems differ in kind: recovering the all-in-focus image is ill-posed and needs a generative prior, whereas rendering blur is largely determined by depth and the focal plane. We therefore propose FlashReFocus, which runs diffusion once per photograph and renders every edit with a lightweight network. To address the ill-posed restoration, a one-step diffusion deblurrer with a decoder refiner recovers fine detail efficiently while balancing fidelity and perceptual quality. For precise control, the renderer is conditioned on an explicit defocus map and uses defocus-bias attention, which lets pixels at similar defocus share information without interference from pixels at other depths; in-focus content stays unchanged, and editing the map yields tilt-shift and two focal planes. To further test generalization to unseen cameras, we collect 3CReal, a three-camera benchmark of 89 pairs. FlashReFocus achieves the best perceptual fidelity for zero-shot bokeh rendering on EBB! and 3CReal, refocuses 148.3x faster than GenRefocus, and takes about half a second per further edit, 462x faster.

0.29
23

Uncertainty-Aware Cortical Surface Reconstruction and Spherical Registration for Heterogeneous Brain MRI

eess.IV cs.CV ·2026-10-12 ·Jesper Duemose Nielsen, Karthik Gopinath, Andrew Hoopes, Adrian Dalca, Axel Thielscher +2 more
Abstract

Surface-based cortical analysis is useful in many applications as it is a natural way to model the highly folded structure of the cerebral cortex, allowing quantities such as curvature and thickness to be easily calculated. Existing deep learning (DL) methods have focused on 1x1x1 mm3 T1-weighted (T1w) scans, thus replicating classical pipelines. Here we present a neural network that is trained exclusively on synthetic scans with random contrast and resolution. Consequently, it can be applied to almost any kind of magnetic resonance imaging (MRI) scan. In addition, our model provides vertex-wise uncertainty estimates of the predicted surface as well as a spherical registration to fsaverage space. Our model performs on par with other state-of-the-art DL methods on 1x1x1 mm3 T1w scans and outperforms the only other method capable of estimating cortical surfaces from low resolution, non-T1w scans. The predicted uncertainty, moreover, correlates with overall scan quality on low resolution scans and highlights areas of poor surface reconstruction on 1x1x1 mm3 T1w scans, suggesting that it can be used for quality control. Finally, the predicted spherical registrations prove comparable to other DL and classical registration methods. These qualities, when combined with the fast inference time, will provide the ability to analyze large, existing databases of clinical MRI scans, with the potential for finding disease-specific patterns that would otherwise be infeasible in a research setting.

0.29
24

Deep Learning for Forest Plantation Mapping in Godavari Districts of Andhra Pradesh, India

eess.IV cs.LG ·2026-10-14 ·Snehal More, Anuj Karpatne, Valerie A. Thomas, Randolph H. Wynne
published
Abstract

Small-area forest plantations play a vital role in the socioeconomic well-being of farmers in Southeast Asia. Most plantations are established on former agricultural land, often on land less suitable for agriculture. Plantations that are converted from natural forest have adverse impacts on biodiversity. Mapping small-area plantations is thus important to understand the dynamics of forest cover in Southeast Asia and to study the social, economic, and ecological effects of this important land cover and land use change. While the small size of forest plantations makes it difficult to detect them using moderate resolution satellite sensors, the problem is exacerbated by the high degree of mixing between plantations, surrounding vegetation, and other land covers, which often show variegated responses in satellite signals across space and time. In this paper, we study the problem of mapping small-area forest plantations in East and West Godavari districts of Andhra Pradesh, India using deep learning methods. Remotely sensed cloud-free data from the Harmonized Landsat Sentinel-2 S10 product were classified using a pixel-level neural network and training data labeled using a field-based survey in concert with expert aerial photo interpretation. We compare the performance of deep learning methods with a baseline random forest classifier in our study region of 21543 sq. km over a period of 3 years and analyze the differences in the results across land cover classes and seasons.

0.29
25

Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide Imaging

eess.IV cs.CV ·2026-10-16 ·Julia Merta, Daniel Mendelsohn, Benedikt Schoser, Joanna Polanska, Michal Marczyk
benchmarkcode/data
Abstract

Technical artifacts introduced during tissue preparation or slide scanning remain a major obstacle to developing robust computational pathology algorithms for hematoxylin and eosin (HE)-stained whole-slide images (WSIs). Despite the growing number of quality-control tools, their real-world utility remains hard to assess because of the limited number of publicly available implementations and the lack of systematic, multi-dataset comparisons. This paper presents a benchmark of artifact segmentation methods for HE-stained WSIs. After a literature review, six publicly available algorithms were selected and compared in terms of their ability to segment artifact-free tissue and selected artifact classes. Two publicly available datasets and a newly introduced dataset released to support further research were used for evaluation. Tissue samples from multiple medical centers and different organs are included, enabling evaluation across heterogeneous data sources. Segmentation performance was assessed using Dice Index, pixel-level recall, and false discovery rate for artifact-free tissue segmentation. For algorithms supporting multiclass artifact segmentation, class-wise Dice Index and inter-class misclassification were evaluated. In addition to segmentation quality, processing time was assessed. Statistical analysis revealed significant differences in segmentation performance between methods. HistoKit, which incorporates a modified version of the GrandQC, was identified as the best-performing algorithm, while HistoQC was the worst. In terms of artifact types, dark spots and out of focus regions were harder to segment than others. Finally, a simple post-processing step was introduced for HistoKit, which further improved segmentation performance. The benchmark establishes a reference for evaluating and developing artifact segmentation methods for HE-stained WSIs.

0.29
26

Reliability-Preserving Compression for Deployable Medical Image Segmentation

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-18 ·Sagar Kumar, Shailja Sharma, Tirthajit Baruah, Punit Rathore
Abstract

Post-training compression of pretrained medical segmentation models commonly uses quantization, pruning, or distillation to reduce model size and computational cost. Existing medical segmentation quantization studies mainly evaluate Dice, model size, memory, and latency, but this is incomplete for safety-critical use because compressed models should also preserve uncertainty signals that indicate unreliable predictions. We study this problem in compressed MRI/CT segmentation and formalize why Dice can remain stable while uncertainty changes. Motivated by this failure mode, we propose score-guided aggregate-validated mixed precision (SGAV-MP), a post-training compression framework that selects layer precisions under reliability constraints. SGAV-MP ranks quantization actions with a compact benefit-risk score and accepts them only after full-model reliability validation on a calibration set. Across five 2D backbones and three 3D benchmarks, SGAV-MP preserves FP32-level Dice and high uncertainty-map agreement, achieving $3.59\times$--$7.8\times$ compression in 2D and $4.73\times$--$7.82\times$ in 3D. We also report backend-supported TensorRT deployment measurements separately to distinguish runtime execution from reliability-preserving storage compression.

0.28
27

LowNet: Looped Wavelet Neural Networks with 24 Learnable Parameters for Solving Poisson Equations

cs.AI cs.CVcs.LGeess.IV+2 ·2026-10-18 ·Yuanhao Gong
Abstract

Poisson equations frequently appear in various fields, such as mathematics, physics and informatics. Solving Poisson equation, however, is challenging. Traditional methods are not data-specific, although have high certainty. They require a large number of iterations due to the CFL numerical stability. In contrast, deep learning methods are data-driven and more efficient, but require accurate training data and suffer from heavy computation. To tackle these issues, we propose a wavelet-inspired Poisson solver with 24 trainable scalars. The proposed network has several advantages. First, it is compact. It has four independent $5\times5$ kernels, each represented by six parameters, leading to 24 scalars in total. Such compact format can be deployed on most devices. Second, thanks to the loop design, it achieves higher accuracy than previous methods. A residual loop reuses the wavelet block without increasing its parameters. Numerical experiments confirm that such loop indeed improves the solving accuracy. On 10000 images, one, two, and three loops of the wavelet block lead to PSNRs of $47.27$, $74.14$, and $100.74$ dB, respectively. Third, the proposed method is computationally fast. Thanks to the wavelet transform, the proposed method has linear computation complexity, leading to high computation performance. In short, we propose a novel looped wavelet neural network with compactness, accuracy and efficiency for solving Poisson equations. Our method can be applied in various fields, such as computational fluid dynamics, image reconstruction, biomedical engineering, electromagnetic field simulation.

0.27
28

DinoMUSE: A DINOv2-guided Framework for Unsupervised Lateral Motion Estimation in Ultrasound Elastography

eess.IV cs.CV ·2026-10-16 ·Xiyao Meng, Xingyue Wei, Baihua Luo, Bo Peng, Jianwen Luo
code/data
Abstract

Quasi-static ultrasound elastography (USE) is a non-invasive imaging method for assessing soft tissue mechanical properties. Limited by low resolution, low sampling frequency and lack of phase information in the lateral direction, accurate lateral motion estimation remains a critical bottleneck in USE. Existing methods mainly rely on local image matching and physical constraints (such as tissue incompressibility assumption and effective Poisson's ratio), which lack sufficient contextual information. We present DinoMUSE, a DINO-guided mixture-of-experts (MoE) framework for unsupervised lateral motion estimation in USE. DinoMUSE incorporates high-level visual representations learned by DINOv2 into the motion estimation network to provide global contextual guidance. To facilitate effective interaction between DINOv2 features and local matching features, an MoE-based feature-fusion module adaptively transforms and integrates the two representations. Evaluations against NCC, GLUE, RAFT, and sPICTURE on simulation and in-vivo breast datasets show that DinoMUSE substantially improves lateral estimation accuracy while maintaining competitive axial performance. Specifically, DinoMUSE reduces the mean square error (MSE) of lateral displacement and strain estimation by 60% and 65%, respectively, compared with a SOTA algorithm on the simulation dataset. For in-vivo breast data, DinoMUSE achieves axial strain SNR and CNR of 5.70 and 4.82, and lateral strain SNR and CNR of 4.61 and 2.23, compared to 4.11 and 3.32, and 4.57 and 2.13 for the best competing method, alongside improved lesion visualization. These findings indicate the potential of leveraging transferable visual representations and adaptive feature fusion to improve lateral motion estimation in USE. The code is available at xxxxxxxx.

0.27
29

Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy

eess.IV eess.SPphysics.med-ph ·2026-10-16 ·Stephen A Lee, Isidora Jelenkovic, Maia V. Kokoeva, Jean Provost
unusual
Abstract · 11 pages

Clutter suppression is a critical preprocessing step in ultrasound blood flow imaging, yet conventional singular value decomposition (SVD) filtering depends on data-specific eigenvalue cutoffs that can remove slow flow along with tissue clutter. Here, we introduce adaptive eigenspectrum remapping (AER), a general framework in which clutter is suppressed by continuously remapping, rather than truncating, the eigenvalue spectrum of the spatiotemporal covariance, and we investigate zero-phase component analysis (ZCA) matrix whitening as an instance of AER for transcranial ultrasound localization microscopy (ULM). Rather than discarding eigenspaces, ZCA-based AER whitens the eigenvalue spectrum, reducing the dominance of coherent clutter, including skull reverberation, while retaining weak flow signals. We evaluate AER on both temporal and spatial covariance matrices in mouse brain datasets acquired with long temporal ensembles. Compared with SVD filtering, ZCA improves microbubble contrast and vascular image quality, increases trajectory density across low- and high-concentration regimes, and reveals more low-velocity trajectories in ULM velocity maps. Spatial AER further maintains reconstruction quality across extended ensembles and enables fuller single capillary reporter (SCaRe) reconstructions, including connected artery-to-capillary-to-vein tracks. These results support AER, here instantiated as ZCA whitening, as a data-adaptive alternative to manually thresholded SVD filtering for high-resolution microvascular imaging.

0.26
30

ProtoGTX: Prototype-Aligned Graph Transformer for Explainable Whole-Slide Image Analysis

eess.IV cs.CVq-bio.QM ·2026-10-16 ·Iori Azuma, Hiroyuki Kusuhara, Tadahaya Mizuno
code/data
Abstract · 14 pages, 3 figures, 2 tables. Code: https://github.com/mizuno-group/ProtoGTX

Deep learning has achieved strong performance in computational pathology, but explaining whole-slide image (WSI) predictions remains challenging. Existing explanation methods often highlight important regions without identifying their morphological patterns, leaving a gap between patch-level computational evidence and slide-level pathological interpretation. We propose ProtoGTX, a graph-based framework that combines spatial contextualization with a flexible morphological prototype vocabulary. ProtoGTX separates the reference prototypes used to define morphological concepts from the predictive model: the reference vocabulary can be generated from training data by unsupervised clustering or supplied externally, and remains fixed during classifier training. Patch features are first contextualized over a spatial graph, after which learnable prototypes representing morphological concepts are optimized through cross-attention. Their slide-level activation profile is aligned with the morphological composition induced by the fixed reference prototype bank. On the CPTAC and BRACS datasets, ProtoGTX outperforms the evaluated MIL, prototype-based, and graph-based baselines, with particularly pronounced improvements on BRACS. Qualitative analyses further show that spatial contextualization transforms fragmented patch-level prototype assignments into more coherent tissue regions. In BRACS, prototype maps also co-localize with pathologist annotations and regions relevant to slide-level prediction. These results demonstrate that ProtoGTX provides complementary semantic and spatial explanations while retaining a prototype vocabulary that can be defined independently of the predictive model. Code is available at https://github.com/mizuno-group/ProtoGTX.

0.25
31

Per-Bundle, Pre-Reconstruction Inversion for Temporal CT: Flux-Compensation Design and Training-Free Empirical-Bayes Estimation

eess.IV ·2026-10-13 ·Guy M Besson
Abstract · v2: title changed from v1 (was "...: Flux-Compensation Design and Multi-Patient Generalization"); corpus results recomputed with the truth-f…

In Temporal computed tomography (TCT) each detector reading sums the photons of up to three rays. Earlier work set the resulting per-bundle limits and tested a learned prior on one patient at one incident count $N_0$; this paper lifts both. N$_0$FC ($N_0$ flux compensation), a bow-tie and tube-current-modulation co-design, equalizes each bundle's detected flux. SNN2 is a per-bundle Poisson maximum-likelihood estimator. V8c is a neural-network corrector trained on 19 patients stratified by water-equivalent diameter (WED). T2bp, a training-free empirical-Bayes post-processor, combines per-bundle Poisson likelihoods with a prior built from the patient's own bundles. Results use that work's Dose Inflation Factor (DIF), charging bias as error. On 23 non-test volumes, N$_0$FC lowers the per-volume median middle-path Cramer-Rao floor, as a DIF, from 23-48 under a flat-fluence (no bow-tie) baseline to 3.3-6.3 at 35-62% of its incident photons, near the equal-attenuation value 13/3 and 1.4-1.7 times below conventional bow-ties; the bow-tie alone achieves this median, and tube-current modulation trims the tail. For bundles with $X_2<6$ (83%), SNN2 attains this floor (median mean-squared-error ratio 1.02); training-free T2bp$\circ$SNN2 lowers the ratio to 0.89 (0.74-1.26). It is best or tied on three of four N$_0$FC test cells (WED 207-342 mm) and trails T2bp$\circ$V8c by 3% on the fourth. V8c beats SNN2 in distribution under baseline acquisition, gains at most 9% under N$_0$FC (losing 14% on the largest in-distribution test patient), and fails on a patient acquired below its training count level. Acquisition co-design removes most of the attenuation-contrast penalty, and training-free estimation attains the resulting limit. The remaining three- to six-fold gap to single-source CT at equal fluence, and the high-attenuation tail, are targets for inter-bundle priors.

0.25
32

Stabilizing Illumination Conditioning in SSM-Based Low-Light Image Enhancement with Bottleneck Prompt Sidecars

eess.IV cs.CV ·2026-10-16 ·Wei Chen Ng, Qiyi Xie, Jian Ding Tan, Yan Kang Lee, Abdulrab Hakim Qaid Abdullah +1 more
Abstract

Low-light image enhancement (LLIE) requires more than brightness amplification because real low-light images often exhibit spatially varying illumination, amplified noise, color distortion, and local detail loss. Recent SSM- and Mamba-based restorers provide efficient long-range modeling, yet the route for introducing illumination priors into such backbones remains insufficiently studied. This study addresses safe illumination conditioning for SSM-based LLIE through a bottleneck-side PromptAdapter. A lightweight illumination estimator first predicts a single-channel illumination map, which is then converted into prompt tokens and injected through a residual sidecar adapter at the bottleneck, thereby avoiding direct modification of the state-space core. Under a locked three-seed evaluation protocol on LOL-v1, LOLv2-Real, and LOLv2-Synthetic, the PromptAdapter improves over the Base model by 0.94 dB, 1.24 dB, and 0.93 dB in PSNR, respectively, while also improving SSIM, LPIPS, and masked dark-region metrics. The clearest real-data evidence appears on LOLv2-Real. A Learned-Fixed control on LOL-v1 indicates that the present results support the utility of the sidecar conditioning pathway more strongly than a strict claim of illumination-conditioned superiority, and the LOLv2-Synthetic result remains stability-conditioned. These findings suggest that, in SSM-based LLIE, conditioning design can be as important as the conditioning signal itself.

0.25
33

An Anatomy-Aware Staged Pipeline for Vessel-Specific Intracranial Aneurysm Segmentation in CT and MR Angiography

eess.IV cs.CV ·2026-10-15 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published
Abstract · Submitted version (7 August 2026) of a paper accepted at SWITCH+ 2026, a MICCAI 2026 workshop (TopAneu 2026 challenge track). Table 1 entrie…

The TopAneu 2026 challenge requires intracranial aneurysms to be segmented at the voxel level and assigned to one of more than fifty vessel-specific classes, on CT and MR angiography alike. We address it with a six-stage anatomy-aware pipeline rather than a single segmentation network. A logistic-regression classifier routes each scan to a modality-specific branch; networks segment the vasculature, first as a binary mask and then over the full 36-class arterial taxonomy; a candidate localiser turns raw angiography and vessel priors into suspicious regions; a candidate-centred network segments the lesion in each crop; connected components become instances; and a per-instance classifier assigns each its anatomical location. Two principles organise the design. Whenever an upstream model output becomes a downstream training input it is generated out-of-fold, so no stage trains on unrealistically clean predictions of itself. And the anatomical decision is made once per lesion rather than once per voxel, which fits the data: of 406 connected aneurysm components in the full release, 405 carry exactly one location label. Task 1 is read off the Task 2 mask, making the two consistent by construction. We report stage-wise performance and a five-part ablation isolating what vessel priors and class-aware sampling contribute at each stage.

0.24
34

A Unified Theory of Image Scaling: Point Spread Functions, Discrete Kernels, and Scale-Spaces

eess.IV cs.CV ·2026-10-15 ·Assaf Shocher
unusual
Abstract

We derive the optically aligned system of image-scaling operators $\mathbf{K}_s$ that reproduces optical zoom (exact zoom-out, canonical zoom-in), by identifying a Huygens-like consistency principle in which each pixel acts as a secondary source. The system is determined in closed form by the camera's point spread function (PSF), itself the operator $\mathbf{K}_0$. The operators compose, $\mathbf{K}_{s'} \circ \mathbf{K}_s = \mathbf{K}_{ss'}$ (with band projection for down-up), and account for both upscaling and downscaling, which form a Moore-Penrose pseudoinverse pair, $\mathbf{K}_{1/s} = \mathbf{K}_s^\dagger$. We show that image scaling, as routinely practiced, is neither optically faithful nor internally consistent; for example, common anti-aliasing rules generally correspond to no camera, and two resizes by a factor of $1/2$ generally do not equal one resize by a factor of $1/4$. Gaussian scale-space kernels cannot be exact finite-aperture PSFs. Gaussian scale-space is an idealized special case of what emerges here: a generalized scale-space for sampled images, derived entirely from camera optics, bidirectional, and not limited to Gaussian kernels. The system goes beyond scaling and supports composable and invertible subpixel geometric transformations. We empirically validate its optical predictions with real captures and noisy optics simulations, and demonstrate its practical impact on the stability of tasks such as super-resolution and classification.

0.22
35

Background2Background: a self-supervised background removal framework for high dimensional microscopy

eess.IV cs.CVphysics.optics ·2026-10-13 ·Guangrui Ding, Haonan Lin, Rong Tang, Bethany Weinberg, Jianpeng Ao +6 more
unusual
Abstract

High-dimensional microscopy captures features across space, time, and spectrum, but complex backgrounds obscure signals. We present Background2Background (B2B), a self-supervised background removal framework leveraging the backgrounds larger correlation relative to the signal. Local pixel shuffling disrupts signal correlations while preserving background structure, transforming signals into effective noise for Noise2Noise-based background removal. Across fluorescence, stimulated Raman scattering and mid-infrared photothermal imaging, B2B achieves over 40-fold background suppression and reveals hidden signatures.

0.22
36

DoReMe: Dual optimization of Reconstruction and Motion estimation for self-navigated free-breathing abdominal MRI using Gaussian Splatting

eess.IV cs.CVphysics.med-ph ·2026-10-13 ·Majd Helo, Dominik Nickel, Thomas Kuestner
Abstract · 25 pages, 2 tables and 7 figures

Purpose: Free-breathing abdominal MRI is limited by respiratory motion, which introduces image artifacts and k-space inconsistencies. Existing reconstruction approaches often depend on pre-estimated motion fields or external respiratory surrogate signals. We propose a coupled reconstruction-motion estimation algorithm for self-navigated free-breathing acquisition, in which motion is represented by compact Gaussian primitives and jointly refined with the image estimates during iterative reconstruction. Methods: An iterative reconstruction that alternates between data consistency updates and motion modelling was proposed. Respiratory motion was represented using Gaussian primitives. A Gaussian splatting was integrated into the reconstruction algorithm. The method was evaluated on self-navigated free-breathing Cartesian gradient-echo (GRE) acquisition in four healthy volunteers, including retrospective scan shortening experiments, and was compared with regularized compressed sensing (CS) reconstruction. Results: Respiratory motion states were reconstructed in approximately 1.5 min. Compared with CS, the proposed method improved visual image quality, particularly in coronal liver views, and better preserved anatomical structures in retrospectively shortened acquisitions. These findings provide proof of concept for the proposed method. Conclusion: The proposed coupled reconstruction-motion estimation algorithm improved visual image quality compared with CS alone. Gaussian primitives provided a compact and sufficiently flexible representation of nonrigid respiratory motion with practical runtime, supporting further scanner integration and validation in larger cohorts.

0.22
37

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer

cs.CV eess.IV ·2026-10-14 ·Elmira Mirzabeigi, Zahra Khalilzad, Taylor Snowden-Richardson, Jesus Eduardo Lugo Arce, Jodie R. Gawryluk +2 more
unusual
Abstract

Reliable brain-mask transfer into native fluid-attenuated inversion recovery (FLAIR) space can fail when T1-to-FLAIR rigid registration is unstable. We developed A$^3$PreCore, a six-degree-of-freedom rigid-registration strategy that aligns the full bias-corrected T1-weighted image to native FLAIR using normalized mutual information while preserving the established T1-space anatomical mask. We also introduced extended quantitative quality control (E-QC), which characterizes mask extent, field-of-view-relative position, FLAIR intensity support, boundary support, inferior morphology, and pairwise geometric disagreement. In 78 participants with paired T1-weighted and FLAIR imaging, A$^3$PreCore was compared with fsl_anat and the Brain Extraction Tool (BET). Gross rigid-body misregistration occurred in 21/78 fsl_anat outputs (26.9%) and 0/78 A$^3$PreCore outputs (exact two-sided McNemar p=9.54 x 10^-7). Among 57 participants without gross fsl_anat misregistration, A$^3$PreCore preserved close agreement (median Dice=0.993; median paired Delta NMI=-0.00007, p=0.429). A$^3$PreCore remained broadly concordant with BET (median Dice=0.955), with less inferior and extracranial extension in representative comparisons. Method-blinded neuroscientists ranked A$^3$PreCore first in 35/40 participants (87.5%). E-QC additionally exposed severe orientation-related disagreement not evident from global descriptors or centroid displacement alone. These findings support A$^3$PreCore as a robust native-FLAIR brain-mask transfer strategy and E-QC as a complementary framework for multidimensional mask characterization and participant-specific geometric quality control.

0.22
38

A New Hope for PRNU on Modern Smartphones? Evidence That Device-Specific Fingerprints Survive Computational Photography

cs.CV eess.IV ·2026-10-18 ·Benjamin Loison, Quentin Bammey, Thibaud Ehret, Rafael Grompone von Gioi, Pablo Musé +1 more
unusual
Abstract

Photo Response Non-Uniformity (PRNU) is widely regarded as the most reliable marker for source camera identification. Recent studies, however, report high correlations between images and fingerprints from different modern smartphones, which calls into question the discriminative power of PRNU on these devices. Using 30 recent smartphones under controlled acquisition conditions (e.g., no digital zoom), we investigate whether the fingerprint itself is at fault or the way it is compared. We find that a component shared by all fingerprints of the same model inflates the standard signed peak-to-correlation energy (sPCE). To counter this, we propose $Δ$sPCE: the sPCE between a query image and a candidate camera's fingerprint, minus the mean sPCE between that image and the fingerprints of the remaining candidates, in the spirit of T-norm score normalization. $Δ$sPCE improves attribution accuracy, suggesting that the device-specific PRNU signal is still present. Although the limited dataset size and the dependence of $Δ$sPCE on the candidate camera set currently restrict operational applicability, these results suggest that PRNU-based attribution of modern smartphones remains feasible when fingerprints are compared appropriately.

0.22
39

LGGS: Longitudinal MRI Reconstruction via Guided Group Sparsity

eess.IV cs.CV ·2026-10-15 ·Nikola Janjušević, Hersh Chandarana, Yao Wang, Li Feng
Abstract · 10 pages main, 8 figures main, 5 pages supplementary, 7 figures supplementary

Serial MRI is routinely performed in current clinical practice for disease surveillance and applications such as MR-guided radiotherapy. However, long MRI scan times increase costs and limit patient access, making accelerated image reconstruction of broad clinical importance. Previous scans of the same patient contain image information highly correlated with the current exam, yet existing reconstruction methods rarely exploit this information. Major challenges in the effective use of prior scans include inter-visit misregistration, pathological changes, and image phase variation. In this work, we propose Longitudinal Guided Group Sparsity (LGGS), an interpretable deep-learning framework for longitudinally informed MRI reconstruction derived from classical group sparsity. The prior scan is incorporated into the reconstruction regularizer through learned phase-invariant circulant attention that identifies corresponding features across exams. This formulation provides robustness to local in-plane and through-plane misregistration as well as inter-visit phase variation. Across acceleration rates, LGGS achieves state-of-the-art performance on longitudinal T1-weighted multi-coil brain MRI data, outperforming the evaluated unguided and longitudinally informed reconstruction methods, with substantially fewer learned parameters. We further evaluated the contributions of multiple guide slices and phase-invariant similarity and demonstrated that accelerated prior images can also serve as effective guides with minimal degradation in reconstruction quality.

0.21
40

UniPolar: Joint Image and Polarimetric Restoration under Compound Degradations via Physical Consistency Learning

cs.CV eess.IV ·2026-10-16 ·Yang Jin, Guangyu Guo, Linghao Shen, Binglu Wang
benchmark
Abstract · 13 pages, 11 figures

Polarimetric image restoration aims to recover polarization angle images and reliable polarimetric quantities from degraded observations. Beyond visual fidelity, it also requires preserving the physical relationships underlying reliable polarimetric estimation. However, existing methods typically address either device- or environment-induced degradations in isolation, limiting their applicability to color polarization filter array (CPFA) imaging, where both often coexist. Such compound degradations jointly perturb image intensities and cross angle polarization differences. Consequently, improved image fidelity alone does not necessarily ensure accurate Stokes, DoLP, and AoLP recovery. To address this challenge, we propose UniPolar, a coupled Image Stokes framework for joint image polarimetric restoration from compound-degraded CPFA observations. Specifically, UniPolar employs two complementary streams to reconstruct four polarization-angle images and directly predict Stokes difference components. To coordinate these streams, Degradation Conditioned Cross Domain Interaction combines Dual Domain Frequency Interaction for frequency selective evidence exchange with Degradation Conditioned Modulation for condition adaptive feature correction. Furthermore, at the output level, Image Stokes Physical Consistency Learning aligns image derived and directly predicted Stokes components while regularizing angular fidelity and the physical feasibility of DoLP. On the compound-degradation benchmark, UniPolar achieves average image and DoLP PSNR of 31.522 dB and 24.097 dB, respectively, with an average AoLP error of 16.833 degree. These results underscore the importance of jointly considering visual fidelity and polarimetric reliability, offering a physically grounded perspective on learning based restoration under compound degradations.

0.21
41

Image Restoration with Impulse Noise Based on Minimax Concave Penalty: Grayscale and Color Images

eess.IV ·2026-10-18 ·Reza Parvaz
Abstract

In today's world-where social networks play a significant role-images serve as one of the most important tools for transferring concepts. Image degradation caused by noise or blurring hinders the effective transmission of the information we expect to derive from an image. Consequently, developing image restoration methods capable of revealing crucial information is of great importance. In this work, a model for impulse noise image restoring is proposed by using a Minimax Concave Penalty. The proposed model is applicable to both color and grayscale images. Then, a numerical algorithm based on the alternating direction method of multipliers is introduced, and the convergence of the method is analyzed both theoretically and numerically. In the final step, the proposed method is evaluated through simulations on several examples, and the results demonstrate its effectiveness.

0.21
42

LightHybridNet: A Lightweight Hybrid Deep Learning Framework for Efficient Multi-Label Ophthalmic Disease Classification in Imbalanced Fundus Images

eess.IV ·2026-10-14 ·Hem Raj Dadral Najam Ul Hasan, Naveed Ejaz, Muhammad Aslam Jarwar
Abstract

Eye diseases are a major global cause of blindness and vision impairment, highlighting the need for accurate and early diagnosis to prevent further deterioration. Despite advances in medical imaging, classifying retinal diseases from fundus images remains challenging due to the complexity and subtlety of visual features. This study aims to develop and validate LightHybridNet, a novel lightweight hybrid deep learning framework, to improve the classification of eye diseases from fundus images. The model incorporates architectural features, such as depthwise separable convolutions and compound scaling mechanisms, to enhance diagnostic accuracy and robustness. To validate the model, the ODIR-5K dataset, comprising 8 disease categories, was used. To enhance image quality, pre-processing approaches were applied, including histogram equalisation, colour space conversion, and contrast adjustment, resulting in high-resolution images. Furthermore, image augmentation was employed to increase the dataset size, thereby improving the model's ability to generalise during training. The hybrid architecture helps the model concentrate on relevant image regions while capturing and integrating details at different scales, significantly improving classification performance. To evaluate its effectiveness, the model was compared with transfer-learning models. The results show that LightHybridNet outperforms the baselines, achieving a weighted F1-score of 91.51%, a macro AUC of 98.26%, and a Cohen's Kappa of 90.14% on the validation set. Furthermore, model interpretability was enhanced using explainable AI methods, including Grad-CAM, to identify and emphasise features influencing the decision-making process. LightHybridNet represents a promising advancement in automated ocular disease detection, offering improved diagnostic reliability for clinical use.

0.20
43

Perceptual Characterization of Scan-induced Artifacts in Dynamic 3D Meshes

eess.IV cs.MM ·2026-10-13 ·Huong Hoang, Truong Nguyen, Pamela Cosman
Abstract

Dynamic meshes reconstructed from real-world scenes often exhibit scan-induced artifacts such as surface jitter and missing geometry, which strongly impact perceived visual quality. Objective assessment remains challenging due to the absence of artifact-free ground truth and limited perceptual understanding of artifact interactions. This paper presents a systematic and controlled perceptual study of scan-induced artifacts in dynamic meshes, focusing on surface jitter and holes. To enable systematic analysis, we introduce a physically grounded artifact synthesis framework in which holes are synthesized using a reconstruction uncertainty model derived from multi-view geometry. The study reveals asymmetric cross-artifact interactions, non-additive integration, and motion-dependent temporal masking. Based on these findings, we propose a compact, perceptually grounded no-reference quality assessment framework that encodes the observed perceptual mechanisms.

0.20
44

Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

eess.IV physics.optics ·2026-10-15 ·Hassan Yazdanian, Henrik Mäkinen
Abstract

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

0.20
45

Denoising Textures is a Different Ballgame Altogether!

eess.IV cs.CV ·2026-10-15 ·Saptarshi Mandal, Oindrila Haldar, Chirayata Bhattacharya, Chandra Sekhar Seelamantula, Zhiwei Xu +2 more
position
Abstract

The human brain effortlessly deciphers colors and textures from visual stimuli and reconstructs the world around us, yet preserving such details remains challenging in image denoising. While significant progress has been made in generic image denoising, the problem of texture denoising has remained relatively under-explored. Fine details, such as intricate patterns and repetitive structures, often suffer from over-smoothing even in deep learning based approaches for denoising. In this paper, we analyze the behavior of state-of-the-art (SOTA) denoisers on texture datasets and show that performance improvements are possible only by fine-tuning the denoisers on the texture datasets. Surprisingly, fine-tuning on texture datasets result in the models catastrophically forgetting the original dataset. These findings highlight the need for specialized treatment of textures in denoising. Since denoising quality directly impacts downstream tasks such as generative modelling, we argue that dedicated texture aware denoisers are essential for faithful texture reconstruction and synthesis.

0.18
46

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18
47

Pneumonia Detection on Chest X-Rays Derived from a U-Net Segmentation Model

eess.IV ·2026-10-15 ·Manasvini Singh
Abstract · 6 pages, 3 figures, 6 tables

Pneumonia killed more than 740,000 children under the age of five in 2019, and it can be difficult to recognize on chest radiographs (CXRs): opacities may be faint in early disease, may sit behind the equally bright heart shadow, and may resemble other lung conditions. Most deep learning systems treat pneumonia detection as a yes-or-no classification task. This paper asks whether a model trained on a harder task, segmenting pneumonia pixel by pixel, can be turned into an effective detector for the simpler task of deciding whether an image contains pneumonia at all. The hypothesis is that the detailed supervision of segmentation forces the network to learn where and what the disease looks like, producing a better detector than training for detection alone. A U-Net was trained to segment pneumonia on the RSNA Pneumonia Detection Challenge dataset of 26,684 radiographs, whose rectangular bounding boxes were converted into pixel masks. The data are heavily imbalanced: 22.5% of images are positive, and only 2.6% of pixels fall inside a box, so focal loss with α = 0.25 and γ = 2 and dropout were needed for the model to learn. On the harder segmentation task, the model reached a pixel-level F1 score of 0.45 on a held-out test set of 2,668 images. Applied to the simpler detection task, the same model reached a precision of 0.71, recall of 0.52, and F1 score of 0.60, with 91% specificity, and consistent scores on the development set. These results show that a segmentation-trained model transfers to detection while also showing where the suspected disease is. A direct comparison with a classifier trained only for detection on the same data is needed to confirm whether the segmentation-first approach is better, and is the main direction for future work.

0.18
48

Separating mixtures of single-fiber orientation distributions for increased sensitivity to crossing white matter fibers

eess.IV q-bio.QM ·2026-10-14 ·Adam M. Saunders, Gaurav Rudravaram, Michael E. Kim, Elyssa M. McMaster, Yifan Shuai +8 more
Abstract · 25 pages, 8 figures

Intro: Diffusion MRI allows for in vivo probing of brain tissue architecture via micron-level diffusion aggregated at the millimeter scale, but crossing white matter fibers decrease the sensitivity of downstream tasks such as microstructural modeling and tractography. Current fixel-based methods for identifying the number, orientation, and spread of fibers rely on finding the peaks of fiber orientation distributions from constrained spherical deconvolution. However, this method is biased by the spreads of nearby fibers and fails at angular separations lower than approximately 40-50 degrees. Methods: In this work, we perform a constrained nonlinear optimization called fiber segmentation by signal splitting and iterative least squares estimation (FISSILE), modeling each voxel as a mixture of single-fiber distributions. We use FISSILE to fit axially symmetric fibers in simulations and on three in vivo human subjects from the Human Connectome Project, an ex vivo raccoon brain, as well as the same human subject scanned twice at two different signal-to-noise ratios (SNRs). Results: On simulated data, FISSILE successfully identifies fibers at an angular separation of 40° and a volume fraction of 0.1 at an SNR as low as 30, while MRtrix3's fod2fixel is limited to 60° separation and 0.1 volume fraction at the same SNR. On acquired data, FISSILE identified 85.8% of white matter voxels on average in human brains and 79.4% in the raccoon with at least one fiber crossing, whereas fod2fixel identified 30.1% and 44.5%. The number of white matter fiber crossings was mildly sensitive to different noise levels in the human subject with two acquisitions. Conclusion: A method that models the crossing fiber phenomenon as an unmixing problem increases sensitivity to individual fibers for more precise characterization of anatomy.

0.18
49

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17
50

Learning Variable Metrics for Convergent Proximal Splitting Algorithms

eess.IV ·2026-10-15 ·Yodai Suzuki, Shunsuke Ono
Abstract

We propose learned variable metric (LVM), a framework that learns metrics of proximal splitting algorithms adapted to each problem instance, coordinate, and iteration with a convergence guarantee. Proximal splitting algorithms can solve a wide variety of convex optimization problems but often require many iterations to converge. Choosing a suitable metric is an effective remedy, and variable metric theory naturally extends convergence guarantees to metrics that vary over the iterations. Learning is a promising way to design such adaptive metrics beyond the reach of manual design, but a naive implementation leads to (i) an expensive evaluation of a network at every iteration and (ii) difficulty in satisfying the conditions that the theory imposes on the whole infinite sequence of metrics. To resolve these difficulties, we first train a neural network to generate a few representative metrics once per problem instance, and then obtain the metric of every iteration by combining them with basis functions of the normalized iteration index. We present LVM for the proximal gradient method with a quadratic term and the primal-dual hybrid gradient method, and prove their convergence under a mild spectral condition, which is ensured by a rescaling of the representative metrics. In experiments on deblurring and inpainting, LVM reduces the number of iterations to reach a target accuracy in most tested settings compared with several baselines, and the computation time at high accuracies.

0.16
51

Adv-Camou: An Emissivity-based Physical Dynamic Adversarial Patch for Infrared Attack

eess.IV ·2026-10-15 ·Zhuo Chen, Xu Zheng, Runyun He, Tuoyu Liu, Kaixuan Ding +8 more
Abstract · 11 pages, 5 figures

With the widespread application of infrared object detection technologies in military domains, intelligent infrared adversarial camouflage capabilities have become critical. Existing physical attack methods predominantly employ static thermal suppression strategies, suffering from limited environmental adaptability, insufficient attack robustness, and inadequate visual concealment. This study proposes Adv-Camou, an emissivity-based physical dynamic adversarial patch that achieves paradigm-shifting advancements from static to dynamic attacks through algorithm-material co-innovation. First, a multi-level loss function based on feature confusion mechanisms is designed to deceive detectors by attenuating target saliency and enforcing background feature alignment. Second, adaptive physical transformations and differentiable binarization optimization are integrated to address physical robustness and realizability constraints. A 6*4 array of reversible electrochromic emissivity device is developed and tested across a range of background scenarios, enabling scene-adaptive dynamic camouflage through independent unit control. Experiments demonstrate that this method achieves 95.59% attack success rate (ASR), reducing average precision (AP) by 60.51%. Physical validations show that static adversarial patches attain 76.55% average ASR under multi-view, multi-range, and multi-spectral conditions, while dynamic patches enhance ASR up to 91.55% in complex environments (wilderness/urban) through adaptive switching. The seamless digital-to-physical transfer via tunable emissivity devices transcends the limitations of traditional static camouflage by establishing a dynamic infrared regulation capability. This advancement enhances the battlefield survivability of military assets and demonstrates transformative potential for adaptive camouflage in practical combat scenarios.

0.15
52

End-to-End Learned Image Coding: From Rate-Distortion Optimization to Practical Deployment

eess.IV cs.MM ·2026-10-15 ·Ming Lu, Junqi Shi, Zhan Ma
benchmark
Abstract

End-to-end learned image coding (LIC) has achieved substantial improvements in rate--distortion (R--D) performance, yet practical deployment requires addressing a broader set of system-level constraints. This article provides a deployment-oriented review of LIC, with particular attention to the transition from high-performance neural compression models to practical codecs. We first summarize the basic end-to-end coding framework, including learned transforms, quantization, entropy modeling, and R--D optimization. We then review practical extensions that are increasingly important for deployment, including variable-rate coding and rate control, integer-precision inference and cross-platform consistency, robustness and communication resilience, lightweight and hardware-aware implementation, and standardization and interoperability. To study these issues under a common setting, we further introduce TinyLIC as an open benchmark and reproducible case study for rate--distortion--complexity analysis. Experimental results illustrate the trade-offs among compression efficiency, computational complexity, numerical consistency, and robustness. In particular, TinyLIC with approximately 10 KMACs/pixel decoding complexity substantially outperforms the H.265/HEVC image-profile anchor on Kodak, while the 50 KMACs/pixel configuration achieves performance comparable to the H.266/VVC image-profile anchor on several test sets. The review highlights practical constraints and design trade-offs that remain central to the deployment and interoperability of learned image codecs. Materials are accessible at https://njuvision.github.io/TinyLIC.

0.14
53

Low-Altitude Agentic Networks: From UAV Connectivity to Workflow-Driven Capability Orchestration

eess.IV ·2026-10-13 ·Baolin Chong, Fuhui Zhou, Qihui Wu, Ran Tu
Abstract

Low-altitude platforms are evolving from connected sensing nodes into autonomous agents capable of bounded task interpretation, skill invocation, and local decision making. Increasing the intelligence of individual unmanned aerial vehicles (UAVs), however, does not resolve the organization problem that arises when mission workflows depend on capabilities distributed across multiple platforms and provider feasibility changes with network, resource, and mobility conditions. We propose low-altitude agentic networking as a task-level networking paradigm and develop a reference architecture that separates workflow logic from executor identity. Within a validated domain-specific workflow space, each ready operation is translated into a capability requirement and dynamically bound to an agent that remains feasible under current conditions. Task contracts and structured evidence govern workflow execution, while routine provider and link changes are handled through workflow-preserving local adaptation before high-level repair is invoked. A trace-calibrated discrete-event case study identifies a bounded operating region: conventional organization remains effective for simple workflows under stable conditions, whereas agentic networking becomes beneficial when workflow dependencies are tightly coupled, capability feasibility changes during execution, and viable local recovery paths remain available.

0.12
54

CRUX: Clinical-Text Anchoring for Cross-Institutional CT-Pathology Fusion in Non-Small Cell Lung Cancer Survival Prediction

eess.IV ·2026-10-15 ·Kyungwon Kim, Dosik Hwang
Abstract · 15 pages, 5 figures, 6 tables. Preprint. Extended version of a MICCAI 2024 paper (Kim et al., 2024)

Accurate prognosis in non-small cell lung cancer (NSCLC) benefits from integrating computed tomography (CT) and histopathological whole-slide images (WSIs), which capture complementary macroscopic and microscopic disease characteristics. Fusing these modalities is difficult: their features come from different pretrained foundation-model encoders and lack spatial correspondence, and both are sensitive to institution-specific acquisition and staining, causing multimodal models to overfit site-specific artifacts and generalize poorly. We present CRUX (CRoss-modal Unification via teXt anchoring), a fusion framework that uses clinical text---encoded by a biomedical language model---as an institution-invariant semantic anchor. Because clinical variables follow standardized classification systems, their embeddings occupy a representation space that is consistent across institutions, providing a stable reference frame for aligning heterogeneous imaging features. CRUX introduces a text-mediated cross-modal bridge in which CT- and pathology-derived text-query summaries exchange information within a compact text semantic space through a learnable hub token, avoiding direct image-space cross-attention that would propagate domain-specific artifacts. We evaluate on 2,157 NSCLC patients from five hospitals, holding out one hospital (N=446) entirely for external validation. CRUX attains an external concordance index (C-index) of 0.761, the highest among all unimodal, bimodal, and trimodal configurations. Notably, direct CT-WSI fusion degrades under distribution shift, whereas text anchoring restores and improves cross-institutional generalization. These results indicate that language-model-encoded clinical text is an effective structured prior for robust, generalizable multimodal cancer prognosis.

0.12
55

Tokenized Joint Source-Network Coding for Loss-Resilient Video Streaming

eess.IV cs.MM ·2026-10-15 ·Ke Yang, Sixian Wang, Kailin Tan, Guo Lu, Jincheng Dai +2 more
Abstract

For decades, conventional video streaming systems have relied on packet-level forward error correction (FEC) codes and retransmissions to ensure reliable video delivery. However, in real-time communications, FEC is inherently inefficient under unknown and time-varying packet-loss conditions, while retransmission can incur excessive latency and fail to meet stringent playout deadlines. Emerging deep joint source-channel coding (DeepJSCC) provides an alternative by learning channel-noise-resilient representations, yet its tight coupling with the physical layer makes it difficult to integrate into today's layered network architectures and protocols. In this paper, we propose TokJSNC, a simple-but-effective tokenized joint source-network coding paradigm for packet-loss-resilient video streaming. Rather than first compressing video into a compact bitstream and then protecting it with packet-level FEC, TokJSNC directly encodes video into variable-length discrete token-stream, whose transmission rate is jointly adapted to video content complexity and network conditions. By exploiting the spatiotemporal correlations among learned video tokens, TokJSNC enables robust video reconstruction over a wide range of packet-loss rates without explicit FEC or retransmissions. Consequently, TokJSNC brings the JSCC-like graceful degradation property to the network layer while remaining compatible with existing network architectures and transport protocols. Experimental results show that TokJSNC maintains an average playback frame rate above 22 fps even at a 70% packet-loss rate, whereas the best-performing baseline drops below 12 fps. Overall, TokJSNC establishes a practical pathway for repurposing modern generative video tokenizers for loss-resilient streaming, while providing a fundamental framework for video token communications.

0.04