CS Paper Radar

Weekly top 50 · eess.IV

2026-W33 Aug 10 – Aug 16, 2026

Ranked from 3,675 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Hybrid-LUT: Channel-Aware Hybrid Lookup Table and Filtering for Efficient Image Denoising

cs.CV eess.IV ·2026-08-12 ·Zhilin Ai, Boyu Li, Sidi Yang, Wenqing Shi, Wenyong Zhou +3 more
top venuecode/data
Abstract · Accepted by ECCV2026

Lookup table (LUT)-based image denoising methods have attracted increasing attention due to their high efficiency and hardware-friendly properties. However, existing RGB-LUT approaches require three identical LUTs to process RGB channels in parallel, resulting in large on-chip SRAM consumption. A simple alternative is to apply LUT processing only to the luminance (Y) channel in the YUV color space to reduce memory usage. However, this naive strategy leads to degraded restoration quality, since ignoring the chrominance (UV) channels introduces color distortion and residual artifacts. In this work, we propose Hybrid-LUT, a YUV-based asymmetric channel-processing framework that combines LUT and filtering in a unified design. Specifically, a multi-band LUT branch with pixel-level weight fusion is applied to the Y channel to recover fine textures, while lightweight filtering is used for the UV channels to maintain color consistency. This design reduces LUT storage by two-thirds compared with RGB-LUT methods while maintaining the same runtime throughput. Extensive experiments show that Hybrid-LUT achieves state-of-the-art (SOTA) performance across multiple benchmarks with only 421 KB of storage. In particular, our method surpasses existing LUT-based denoising approaches by at least 0.63 dB CPSNR on real-world datasets, demonstrating its effectiveness for image denoising on resource-constrained edge devices. The project is available at https://github.com/Ai-ZL/Hybrid-LUT .

0.84
2

Dual-Domain Cross-Modal Decoding for Clinical Text-Guided Medical Image Segmentation

cs.CV cs.AIeess.IV ·2026-08-11 ·Md Maklachur Rahman, Tracy Hammond
top venuecode/data
Abstract · Accepted at MICCAI 2026 (Main). Final version to appear in the MICCAI 2026 proceedings

Clinical text can narrow down what to segment, but recent text-guided designs emphasize spatial alignment while overlooking frequency content that governs texture and boundaries. We propose Dual-Domain Cross-Modal Decoding (DD-CMD) for clinical text-guided pulmonary infection segmentation, integrating two complementary forms of language guidance during decoding. In the spatial domain, Text-Guided Spatial Cross-Attention (TGSA) aligns multi-scale visual tokens with text semantics and updates features through gated residual fusion. In the frequency domain, Spectral-Text Adaptive Modulation (STAM) applies a 2D DCT to compute learnable band-energy statistics and predicts text-conditioned FiLM parameters to recalibrate decoder channels for frequency-aware decoding. DD-CMD embeds TGSA and STAM into a coarse-to-fine decoder (7x7 to 56x56) and restores full-resolution masks using a lightweight two-stage refinement module. Experiments on QaTa-COV19 and MosMedData+ show that DD-CMD achieves 91.46% Dice / 84.26% mIoU and 81.95% Dice / 69.42% mIoU, respectively, with average gains of +1.96 Dice and +2.67 mIoU over the strongest prior baselines. Code: https://github.com/maklachur/DD-CMD.

0.84
3

From crown candidates to neighborhood screening: integrating optical GeoAI and spatial modeling for urban-canopy assessment in Davis, California

eess.IV cs.CVstat.AP ·2026-08-14 ·Mohammadreza Narimani, Shreyan Mitra, Parastoo Farajpoor
code/datahighly cited
Abstract · 17 pages, 10 figures + 5 supplementary figures, 7 tables. Revised preprint (expanded canopy infill; IoU 0.719). Preprint submitted to Taylor…

Timely urban-canopy information is essential for linking remote sensing with heat, mobility, and neighborhood planning. We developed an optical GeoAI workflow for Davis, California, using 2022 National Agriculture Imagery Program imagery (0.6 m RGB+NIR). DeepForest generated crown candidates; an NDVI threshold, non-maximum suppression, and box-prompted Segment Anything Model (ViT-B) produced a crown-anchored canopy surface. Analyses used the 25.92 km2 Census TIGER municipal boundary and a 100 m grid. The workflow retained 11,741 candidate crowns and mapped 7.71 km2 of canopy (29.8% of the city). On the identical extent, pixel precision was 0.804, pixel recall was 0.873, and 97.4% of candidate centers agreed with the 2022 USDA/CAL FIRE LiDAR-assisted canopy product (IoU 0.719; Dice 0.837; area recovery 108.5%). Approximately 49% of candidates occurred within 15 m of a road. Canopy was inversely associated with Landsat land-surface temperature (Spearman rho = -0.477; partial rho = -0.551 controlling for built probability), and spatial-lag modeling confirmed clear neighborhood structure. Two transparent attention surfaces combined canopy need with thermal and contextual indicators. The framework provides a reproducible, updateable screening layer that complements structural canopy products and municipal inventories while retaining assumptions, data provenance, and spatial diagnostics for planning interpretation.

0.70
4

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation

cs.HC cs.LGcs.ROeess.IV ·2026-08-11 ·Kenta Yokoe, Takuya Hara, Tadayoshi Aoyama
published
Abstract · This is the accepted version of an article published in IEEE Access 13, 182915-182923 (2025). DOI: 10.1109/ACCESS.2025.3624246. Open Access …

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

0.62
5

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

eess.IV cs.CV ·2026-08-14 ·Yuanchao Bai, Yifan Zhao, Kai Wang, Yuanbo Du, Jie Cheng +3 more
published
Abstract

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

0.60
6

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59
7

ResPCC: A Loss-Resilient Neural Point Cloud Codec over Lossy Networks

eess.IV cs.MM ·2026-08-12 ·Xueqin Niu, Mufan Liu, Yifan Wang, Le Yang, Jun Sun +1 more
top venuecode/data
Abstract

Point cloud compression (PCC) is critical for efficient storage and transmission of 3D data. While recent learning-based PCC methods achieve good rate-distortion (R-D) performance, they generally rely on ideal transmission conditions. In practice, packet loss is a common issue and can severely distort latent features, causing coordinate drift and geometric degradation. To address this challenge, we present ResPCC, the first end-to-end neural point cloud codec designed to offer intrinsic resilience against data loss. Our framework is loss-rate-aware and adapts to diverse packet loss conditions. At the encoder, we introduce a Condition-Adaptive Latent Modulation (CALM) module to adjust latent feature distributions according to the perceived loss rate, as well as a Spatial-Channel Interleaving (SCI) mechanism that transforms channel-wise data extinction into spatially scattered element-wise missing patterns. At the decoder, we develop a Mask-Aware Graph-based Latent Restoration (MGLR) module, followed by a Dictionary-based Refinement (DBR) stage to recover corrupted features and align them with canonical priors. Evaluations on ShapeNet and SemanticKITTI under 5\% to 30\% packet loss rates show that ResPCC consistently delivers superior stability and R-D performance over baselines. Our framework maintains high reconstruction fidelity under lossy conditions, providing a reliable solution for 3D data transmission over practical networks. Code is available at https://github.com/starrynight314/ResPCC.

0.54
8

Geometry-Based Compression of Plenoptic Point Clouds

eess.IV cs.CVcs.MM ·2026-08-11 ·Davi R. Freitas, Gustavo L. Sandri, Ricardo L. de Queiroz
Abstract

Plenoptic point clouds (PPC) are novel data structures that represent the light from different viewing directions in order to provide a higher degree of realism to regular point clouds. This is achieved by associating each point to multiple colors instead of a single one. Here, we present a method to efficiently compress the attributes of a PPC, consisting of a Karhunen-Loève transform over the color attributes followed by multiple attribute coders with intra prediction capability. This compression scheme can be incorporated within the MPEG's geometry-based PCC (G-PCC) standard, using any of G-PCC's existing solutions for attribute coding. Compression performance assessment using PPCs of different spatial resolutions reveals competitive results in comparison to existing methods, such as RAHT-based or video-based PCC solutions. We believe our coder to be the new state of the art.

0.50
9

Lost in k-Space: An Open-Source MR-Physics Escape Room

eess.IV physics.med-ph ·2026-08-10 ·Sabine Melanie Räuber, Marta Brigid Maggioni, Francesco Santini
publishedcode/data
Abstract · 15 pages, 3 figures

Introduction. Operating an MR scanner for technical and clinical research requires multidisciplinary competencies beyond MR physics, including safety management and teamwork. Gamification, particularly educational escape rooms, have been associated with improved motivation, engagement and knowledge retention in health professional education. Materials and Methods. We developed an MR-physics-themed educational escape room for the 41st Annual Meeting of the ESMRMB. Designed for teams of four with a time limit of 25 minutes, the room reproduced the atmosphere of an MR control room. The five puzzles covered the Larmor equation, sequence composition, MR safety and acoustical identification of MR sequences. Custom ESP32 electronics allowed the puzzles to communicate in real time with each other and with the game master Results. The room ran without technical interruptions and was played by 39 teams (approximately 160 participants); 12 solved it (escape rate 31%), with a median solution time of 21 minutes and 53 seconds. Early-career researchers acted as game masters. Discussion. The escape rate aligns with comparable activities targeting scientific audiences. Difficulty can be tuned by adjusting puzzle obscurity, component availability, required prior knowledge and mental leaps. A modified version could usefully supplement mandatory MR safety training. Code, schematics, machining files and documentation are released as open source.

0.44
10

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42
11

TractoGraphVLM: A Unified Vision-Language Framework for White Matter Tractography

eess.IV cs.CV ·2026-08-16 ·Gurucharan Marthi Krishna Kumar, Janine Dale Mendola, Amir Shmuel
publishedcode/data
Abstract · Accepted as a Spotlight at the ECCV 2026 Workshop on Artificial Intelligence for Medical 3D Vision (AI4M3D). Our codebase, including all tra…

Vision language models have transformed 2D medical imaging, yet extending them to 3D white matter tractography remains challenging due to the complex topology of fiber bundles. We introduce TractoGraphVLM, a unified framework for four tasks, bundle classification, text-to-tract retrieval, anatomical captioning, and visual question answering, built on a shared GPS architecture, training procedure, and read-out design. Fiber bundles are represented as streamline graphs whose nodes encode 3D position and tangent orientation. A General, Powerful, Scalable (GPS) graph transformer produces bundle embeddings aligned with a frozen BiomedBERT text encoder via contrastive learning, while a BioGPT decoder with visual prefix tokens generates captions and answers. A single shared encoder and decoder is trained jointly across all four tasks and evaluated from one checkpoint. Trained on HCP Young Adult subjects, TractoGraphVLM achieves 91.8% bundle classification accuracy, 84.7% retrieval R@1, BLEU-4=20.1, ROUGE-L=66.8, and 66.4% VQA accuracy on a held-out test set. The same checkpoints transfer zero-shot to HCP Aging subjects, with a modest drop on discriminative tasks and a larger drop on generative tasks, showing robustness to age and acquisition shift. Language supervision yields richer representations than label-only training, recovering structure like hemisphere and fiber family, carried by captions but never given as a label. Swapping only the visual encoder, graphs preserving fiber orientation outperform volumetric baselines, with GPS giving the best balance. Generative metrics measure consistency with a structured knowledge base rather than independent clinical text; even so, TractoGraphVLM shows that classifying, retrieving, describing, and answering questions about a white matter bundle can be served by one jointly trained model that learns transferable neuroanatomy from language alone.

0.40
12

Uncertainty-Aware Compositional Localization and Placement Assessment of Catheters and Tubes in Chest X-Rays

eess.IV cs.CVcs.LG ·2026-08-11 ·Harshil Lodhiya
Abstract · 21 pages, 8 figures Included declaration for paper is under consideration at Pattern Recognition Letters

Assessing catheter and tube placement on chest X-rays is safety-critical yet tedious and error-prone. Current deep learning methods either classify placement globally -- losing track of which device is where -- or segment all devices into a single mask, making per-device assessment impossible when catheters overlap. We introduce UCompCXR, a compositional framework that detects local catheter fragments, associates them into device instances via graph-based clustering, fuses per-fragment tip predictions through precision-weighted Gaussian estimation, and classifies placement per device. On the RANZCR CLiP dataset (30,083 images, 5-fold patient-level CV with bootstrap CIs), UCompCXR detects 26% more devices than a strong multi-task baseline sharing the same MobileNetV3 backbone, with 75% fewer false positives and well-calibrated tip uncertainty (95% coverage = 0.948). The aggregate tip error rises -- but only because the model finds devices the baseline misses entirely, especially nasogastric tubes. On matched devices, catastrophic localization failures drop substantially. At 2.27M parameters in a single forward pass, the model is deployable on resource-constrained clinical hardware.

0.40
13

ENAF: A Multi-Exit Network with an Adaptive Patch Fusion for Large Image Super Resolution

cs.CV cs.AIeess.IV ·2026-08-15 ·Duong M. Nguyen, Tuan Nghia Nguyen, Xuan Truong Nguyen
publishedcode/data
Abstract · Accepted at WACV 2025

To accelerate single image super-resolution (SISR) networks on large images (2K-8K), many recent approaches decompose an image into small patches and dynamically determine an execution path according to its difficulty (referred to as a dynamic network). To quantify the hardness of a patch, they mainly rely on a handcrafted assessment score, e.g., edge, which weakly associates a patch's texture with the computational complexity of a SISR model. To address the problem, we introduce ENAF - a dynamic network for SISR with an adaptive patch fusion. Built on top of a backbone, ENAF incorporates multiple early exits (EEs) to tackle the over-parameterized SISR model. More importantly, ENAF plugs a tiny network that estimates PSNR to associate data texture with a computation cost at an EE. Based on the scores, ENAF effectively assigns image patches to an exit, enhancing the quality-complexity trade-off. Extensive experiments on common datasets with popular SISR backbones demonstrate the effectiveness of ENAF in various settings. The source code is provided in https://github.com/nmduonggg/ENAF

0.39
14

Physics-Informed Implicit Neural Representations for Improved Myocardial Perfusion MRI Quantification

eess.IV cs.AIcs.LG ·2026-08-11 ·Christos Tsepas, Chang Yan, Maximilian Fuetterer, Sebastian Kozerke, Cian M Scannell
publishedcode/data
Abstract · Accepted at the STACOM workshop at MICCAI, Strasbourg 2026

Quantifying myocardial perfusion from cardiac magnetic resonance (CMR) can be achieved by fitting tracer-kinetic models to the dynamic contrast-enhanced MR data. However, fitting the observed data with multi-compartment exchange models, which describe the evolution of the contrast agent in the tissue, to estimate perfusion parameters is a challenging inverse problem that is sensitive to noise and acquisition variability. Previously, physics-informed neural networks (PINNs) have been proposed as an alternative to conventional non-linear least squares fitting methods with promising results for quantitative perfusion CMR. In this work, we extend the previously proposed PINN framework with spatiotemporal implicit neural representations (INRs) to represent the MR signal as a continuous spatiotemporal function and to improve the accuracy, smoothness, and physical consistency of the PINN model. In realistic simulated CMR datasets, our proposed PINN with INRs demonstrates improved robustness and parameter estimation accuracy over the previously established methods. The code is available at https://github.com/q-cardIA/pinn-inr.

0.38
15

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38
16

Test-Time Instance Selection for Improved Whole Slide Image Analysis

eess.IV cs.CVq-bio.QM ·2026-08-14 ·Quoc Anh Nguyen, Sunhong Park, Jin Tae Kwak
publishedcode/data
Abstract · Accepted at The 2nd MICCAI Workshop on Efficient Medical AI (EMA4MICCAI 2026)

Whole Slide Image (WSI) analysis has been widely studied for cancer diagnosis. Conventionally, a gigapixel WSI is divided into small patches and processed by Multiple Instance Learning (MIL) models. However, existing MIL models typically process all patches, many of which contain redundant or non-informative tissue patterns. Although recent approaches have focused on instance selection to identify discriminative patches and reduce redundancy, these selection modules still require additional training. In this work, we propose Test-Time Instance Selection (TTIS), a training-free, plug-and-play framework that selects compact yet representative patches during inference. TTIS further incorporates a multi-view ensemble strategy to integrate distinct facets of tissue morphology, enhancing robustness. Importantly, TTIS can be seamlessly integrated into existing MIL models without retraining or architectural changes, enabling flexible deployment. Extensive evaluations across multiple benchmarks demonstrate that our approach improves or matches baseline MIL performance across a range of classification and subtyping tasks. Our implementation code is available at https://github.com/QuIIL/TTIS

0.38
17

Synthesizing Post-Acetazolamide Cerebral Blood Flow Maps from Baseline MRI in Moyamoya Using 3D Generative AI

eess.IV cs.AIcs.CV ·2026-08-14 ·Julia Huang, Camila Gonzalez, Rydham Goyal, Aja Zou, Sasha Alexander +3 more
top venue
Abstract · 25 pages. Accepted at Machine Learning for Healthcare (MLHC 2026). To appear in Proceedings of Machine Learning Research (PMLR), volume 340

For patients with Moyamoya disease, impaired cerebrovascular reserve (CVR) is an important hemodynamic criterion for recommending extracranial-to-intracranial bypass surgery. Standard CVR assessment in this cohort uses paired arterial spin labeling (ASL) perfusion MRI acquired before and after acetazolamide (ACZ). When ACZ is contraindicated or avoided, the post-ACZ cerebral blood flow (CBF) map needed for hemodynamic assessment is unavailable. We propose CAE3D, a deterministic 3D conditional autoencoder that synthesizes post-ACZ CBF maps directly from pre-ACZ ASL input. We evaluated CAE3D against ten comparators, including deterministic and diffusion-style 3D baselines, a 2D contextual baseline, and frozen-encoder foundation-model adapters. CAE3D achieved the lowest held-out MAE (0.066), with SSIM 0.80 and PSNR 24.0 dB, and near-zero full-brain mean bias. Its MAE advantage was statistically significant over seven of eight trained-from-scratch baselines, excluding the 2D CAE_2D comparator; its SSIM and PSNR advantages were significant over all eight. Regional delta-CBF predictions compressed the dynamic range in high-response territories. These results establish the retrospective feasibility of post-ACZ CBF synthesis in patients who completed the standard two-scan protocol. Extension to ACZ-contraindicated patients, who were not represented in this cohort, requires external and prospective validation.

0.37
18

ParaJSCC: A Parameterized Framework for Reusable Multimodal Joint Source-Channel Coding

eess.SP cs.MMeess.IV ·2026-08-15 ·Kemi Chen, Mingkai Chen, Youjia Chen, Qian Liu, Wei Gao +1 more
top venue
Abstract

Multimodal signals, such as visual, audio, and tactile data, are increasingly maintained as persistent digital assets in immersive communication systems and digital twins. In these settings, the same multimodal content is repeatedly accessed by heterogeneous receivers with varying modality and bandwidth requirements. Existing compression and Joint Source-Channel Coding (JSCC) methods typically follow a per-request encoding paradigm, resulting in redundant computation and low efficiency during repeated access. To address this issue, we propose ParaJSCC, a multimodal JSCC framework designed for reusable representation serving. ParaJSCC converts each multimodal sample offline at the cloud/content server into a compact, quantized parameter package, which is then stored at the edge serving node for low-latency access. During serving, only the subset required by the current request is transmitted over the wireless channel, followed by lightweight decoding at the receiver. The framework employs a progressive shared-private parameterization to support modality-selective transmission and scalable reconstruction under varying bandwidth constraints. Experiments on multimodal datasets show that ParaJSCC significantly reduces online latency (e.g., from 17.18~ms to 4.34~ms for image-only requests and from 43.96~ms to 11.21~ms for full multimodal requests) and transmission rate (by 47.8\%--51.2\% for selective requests), while maintaining strong reconstruction quality under noisy channels.

0.34
19

Hardware-Aware Deployment of Joint SAR Compression and Despeckling on FPGA

eess.IV cs.LG ·2026-08-11 ·Cédric Léonard, Francescopaolo Sica, Martin Schulz
code/data
Abstract · Submitted to IEEE Transactions on Geoscience and Remote Sensing (TGRS). 11 pages, 8 figures, 4 tables

Next-generation Synthetic Aperture Radar (SAR) missions will generate data far faster than they can downlink, making onboard data reduction essential for near-real-time Earth observation. Learned Image Compression (LIC) offers better rate-distortion performance than handcrafted codecs used operationally today, and recent work shows that simultaneously despeckling and compressing SAR imagery enables better representation capacity while unlocking higher compression rates. These methods, however, have yet to be confronted with the strict power, compute, and operational constraints of spaceborne systems. In this work, we bridge this gap by deploying a joint SAR Despeckling and Data Compression (DDC) framework on an embedded ZCU102 FPGA-based platform, introducing model adaptations that respect the accelerator's fixed-point arithmetic and limited set of supported operations. We evaluate four model topologies across precision levels and across CPU, GPU, and FPGA platforms, revealing several findings with direct design implications. We find that replacing conventional GDN activation functions with plain ReLU improves quality on SAR, suggesting that design principles established for compression of natural images do not necessarily transfer to SAR imagery. In addition, we demonstrate that residual blocks offer little representational benefit for ten times the compute, and show that the FPGA is the most energy-efficient of the platforms tested. Together, these results set a functioning edge deployment workflow and an evidence-based starting point for onboard SAR compression. The code is available at https://github.com/CedricLeon/SAR_DDC_FPGA.

0.32
20

Retrieval-Augmented Vision Foundation Models for Robust Leukemia Cell Classification across Multiple Microscopy Datasets

eess.IV cs.CVcs.LG ·2026-08-11 ·Carlos Zamora, Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
published
Abstract · Accepted at SPIE Optics + Photonics 2026 for oral presentation. 23 pages, 12 figures, 9 tables

Leukemia cell image classification is challenged by real-world domain shifts from acquisition, staining, illumination, and site protocols, causing single-dataset models to generalize poorly in real clinical scenarios. This work presents a robust framework for leukemia classification across multiple heterogeneous datasets using a two-stage pipeline with a pretrained vision foundation model. Stage 1 performs binary classification (leukemia vs. non-leukemia) and is trained using 122,167 single-cell images. Stage 2 is conditionally applied to Stage 1 positives to perform subtype classification into Acute Lymphoblastic Leukemia (ALL) and Acute Myeloid Leukemia (AML), trained using 69,400 single-cell images. Labels are harmonized across five heterogeneous datasets to enable cross-dataset training, and performance is evaluated on a held-out dataset protocol to assess domain-shift generalization. Within this pipeline, three encoders are benchmarked (DinoBloom, pretrained on single-cell images; BiomedCLIP, pretrained on biomedical data; and CLIP as a general-purpose model) under linear probing, Low-Rank Adaptation (LoRA), and a Retrieval-Augmented Classification (RAC) module that retrieves the top-k most similar cell images to provide cytomorphological grounding. The objective is to quantify how much domain-specific pretraining contributes to performance under domain shift, and whether cost-effective adaptation and retrieval can be a viable alternative to expensive domain-specialized pretraining. The held-out protocol additionally serves as a diagnostic tool, revealing when classification performance is attributable to dataset-specific artifacts rather than to cytomorphological features.

0.28
21

A comparison of CNN architectures for Alzheimer's disease detection in single-view MRI scans

eess.IV cs.CVcs.LG ·2026-08-12 ·Hiram Zuniga, Ulises Orozco-Rosas, Kenia Picos
publishedbenchmark
Abstract · Accepted at SPIE Optics + Photonics 2026 for oral presentation. 14 pages, 7 figures, 8 tables

Alzheimer's disease is a leading cause of death with no cure. Therefore, early detection is critical to slow progression and preserve quality of life. Diagnosis relies on medical history, cognitive tests, physical exams, and MRI brain scans, making deep learning suitable for Alzheimer's classification. This work proposes a benchmark that evaluates ten different convolutional neural network (CNN) architectures (including ResNet, DenseNet, MobileNet, EfficientNet, and VGG family models) under the same held-out test split protocol. A two-stage transfer learning and full fine-tuning pipeline is introduced to perform training using a class-balanced subset (3,900 images) derived from the OASIS medical imaging dataset, comprising 86,437 single-view MRI brain scans labeled into four classifications of Alzheimer's disease: Non-Demented, Very Mild Dementia, Mild Dementia, and Moderate Dementia. The best results were achieved by VGG16, with a 0.9637 validation accuracy and a 0.9533 test accuracy score. A key finding documented in this work is the difficulty of classifying the transition from Non-Demented to Very Mild Demented stages, observed consistently across all ten architectures.

0.28
22

Domain-Aware Lightweight Spectral-Grouped Convolutions for Hyperspectral Fish Freshness Classification

eess.IV cs.AIcs.CVeess.SP ·2026-08-12 ·Kazi Nabiul Alam, Pooneh Bagheri Zadeh, Akbar Sheikh-Akbari
published
Abstract · Accepted at BMVC'2026

Hyperspectral imaging (HSI) offers nondestructive assessment of fish freshness by detecting biochemical alterations across spectral bands. However, conventional deep learning approaches do not fully address the particular characteristics of HSI data, such as spectral dominance over spatial textures, ordinal label structure, and a small number of training samples. We propose SGNet (Spectral-Grouped Network), a lightweight architecture that separates spectral and spatial feature extraction using grouped convolutions and a depthwise spatial pathway. A dual attention mechanism that couples channel-wise squeeze-and-excitation with spatial gating adaptively highlights informative features. SGNet achieves 97.8% classification accuracy and 0.64 days mean absolute error (MAE) with just 4.75M parameters when tested on our newly developed 16-day refrigerator-stored salmon fillet dataset. Ablation studies validate the contribution of each component, while comparisons demonstrate a five- to eighteen-fold parameter reduction relative to ResNet-50 and Vision Transformers. Our findings indicate that domain-aware design supports precise, real-time freshness prediction for industrial implementation.

0.27
23

Topology-Aware Query Selection for Surgical Instrument Instance Segmentation

cs.CV eess.IV ·2026-08-12 ·Ze Zhang, Yang Zhang
code/data
Abstract · Preprint. Main manuscript and supplementary material included. Code and reproducibility materials: https://github.com/yqjyzzz/structured-ins…

Accurate foreground masks can still form an incorrect surgical-instrument instance set: duplicate, fragmented, merged, missed, or empty-frame predictions may preserve favorable pixel overlap while violating object identity and count. Final query selection is therefore a relational, variable-cardinality problem rather than a collection of independent candidate decisions. We evaluate topology-aware query selection, which represents the nonempty candidates of a fixed Mask2Former as a complete graph, learns relational candidate and pair representations, predicts set cardinality, and solves an exact structured subset problem. The formal comparison is the complete relational path versus a node-feature-matched path; it evaluates the combined effect of pairwise geometry, message passing, and the additional relational-path capacity, not an isolated component. On the sealed 22-case source test, all three discovery seeds supported instance-set performance improvement with segmentation fidelity and predefined technical-safety preservation: instance F1 increased by 0.0504--0.0612 and positive-frame set-failure rate decreased by 0.0848--0.1060. Direct ROBUST-MIPS transfer reproduced the complete result in all three seeds. Endoscapes supported only one of three seeds and therefore did not establish stable direct transfer. Taken together, the results support a bounded conclusion: the evaluated complete path improved coherent instance-set construction from fixed Mask2Former candidates in specified native-instance contracts, while stable cross-domain transfer and component-specific effects remain unestablished.

0.26
24

MagViT: Interpretable Multi-Magnification Transformers with Patient-Level Model Selection for Breast Histopathology

eess.IV cs.CVcs.LG ·2026-08-16 ·Nabil Ashab, Soumit Kumar Kundu, Saif Mahmud Parvez, Shahadat Hossain Sohag, Bidhan Biswas +1 more
published
Abstract · 13 pages, 5 figures, Accepted for publication in the International Conference on Electrical, Computer and Communication Technologies (ECCT 2…

Breast cancer is one of the most common types of cancer among women around the world. Rapid detection and early treatment can hinder its progress to more complex stages and can impede its spread to other parts of the body. Histopathological image classification is the most common task in cancer detection due to its robustness in analyzing cellular data. Breast histopathology classification requires handling both multi-scale tissue morphology and clinically relevant generalization beyond the source domain. This paper presents MagViT, an interpretable multi-magnification transformer framework with scale-gated fusion and patient-level model selection. The model uses four BreakHis magnifications (40X, 100X, 200X, 400X) and extracts per-scale representations with a ViT backbone, and combines them via a learnable gate that masks missing scales. Patient-level five-fold cross-validation with a fixed seed has been run and compared with three architectural branches. The most accurate branch is then selected as the final model due to the strongest patient-level accuracy while retaining the simplest fusion pathway. On BreakHis, our architecture achieves a mean image accuracy of 0.9191, a mean patient accuracy of 0.9643, and a mean macro-F1 of 0.9042. External transfer experiments provide preliminary evidence of cross-dataset generalization under controlled adaptation settings on BUSI (image accuracy 0.8306, macro-F1 0.7480, patient accuracy 0.8291) and IDC (image accuracy 0.8577, macro-F1 0.8191, patient accuracy 0.8372). Grad-CAM visualization indicates that the model focuses on diagnostically significant and meaningful regions across magnifications. Relative to prior ViT-centered BreakHis work, this study emphasizes patient-level selection and cross-dataset robustness under a reproducible protocol.

0.25
25

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24
26

Boundary-Continuous Cross-Camera RGB Mapping via Hue-Split Model Trees

eess.IV cs.CV ·2026-08-12 ·Yuma Kinoshita, Hitoshi Kiya
published
Abstract · Accepted to APSIPA ASC 2026. 6 pages, 4 figures

We propose a hue-split model-tree method for boundary-continuous cross-camera RGB mapping. Cross-camera RGB mapping aims to produce consistent color representations across cameras whose recorded RGB values differ due to sensor spectral sensitivities and image-signal processing pipelines. A common chart-based remedy is to estimate a single global affine color correction matrix (CCM), but such a global model cannot capture hue-specific discrepancies between cameras. To capture that behavior, we recursively partitions the source-camera color space along a scalar hue coordinate and builds an model tree that stores an affine CCM at every node. For fitting the node CCMs, we utilize a log-domain error objective. To prevent false contours that arise from hard hue splits, we further introduce a boundary-continuous formulation in which the prediction is obtained by blending the log-domain outputs of all node CCMs along the root-to-leaf path. The path-wise blending weights are optimized under a simplex constraint using both a chart-pair fitting loss and an explicit continuity regularizer defined on deterministic boundary prototype pairs placed just on either side of each learned hue threshold. We conducted an experiment on a Canon EOS-1Ds Mark II to Canon EOS 20D mapping using the Middlebury Registered Color Checker dataset. The results show that hue splitting substantially reduces log-RMSE over a single global affine CCM and that the proposed path blending with boundary prototype regularization simultaneously improves accuracy and suppresses chromaticity gaps at the learned hue thresholds across two illuminants and multiple exposure conditions.

0.22
27

Alignment of Similarity-Transformed Images Based on Fourier--Mellin Transform Using Auxiliary Function Method

eess.IV cs.CV ·2026-08-12 ·Shinji Yamashita, Yuma Kinoshita, Hitoshi Kiya
published
Abstract · Accepted to APSIPA ASC 2026. 6 pages, 4 figures

This paper proposes an algorithm for estimating the similarity transformation, namely translation, scale, and rotation, between two images with subpixel accuracy. Image registration is a fundamental technique for aligning images acquired under different viewpoints and imaging conditions, and a representative approach based on maximizing discrete cross-correlation is the Fourier--Mellin registration. However, the Fourier--Mellin approach often fails to achieve sufficient alignment accuracy when subpixel-level estimation is required. The proposed method integrates (i) scale-and-rotation estimation from the Fourier magnitude spectrum in a log-polar representation and (ii) maximization of phase-only correlation based on the auxiliary function method. This integration enables a two-stage estimation procedure: it first estimates scale and rotation without being affected by translation, and then estimates translation with subpixel precision in the spatial domain using the corrected image pair. A simulation experiment on image pairs subjected to random similarity transformations demonstrates that the proposed method reduces estimation errors in scale, rotation, and translation compared with Fourier--Mellin-based registration methods using discrete cross-correlation.

0.22
28

Incision trajectory tracing for electrosurgical navigation by CNN-based knife contacting frames extraction method

eess.IV cs.CV ·2026-08-14 ·Yu Chun Wang, Kaixu Chen, Naoto Ienaga, Yoshihiro Kuroda
published
Abstract

Background and Objective: Image-guided surgical navigation has been actively studied because of its advantage of identifying subsurface targets and critical structures, whereas it requires incision trajectories to update the preoperative three-dimensional model dynamically during the surgery. The novelty of this study is the thermal feature distinguishment of whether the electric tools contacting the tissue by Convolutional Neural Network (CNN), and the extraction of the knife contacting frames, to form incision trajectories which can meet with the requirement during the surgery. Methods: This study firstly verified that CNN can classify the thermal images of electric knife and ultrasonic cutter operations separately, and can raise the accuracy of the incision trajectories derived from the connection of the thermal intensity centroid of the frames predicted by CNN as contacting. Results: Our results obtained by employing the electric knife not only reveal a remarkably high accuracy 97.2 % in CNNs identification, but also can achieve an error reduction as high as more than 2.5 times of the incision trajectory prediction as compared to those proceeded in the conventional method. Besides electric knife, the results obtained by employing another electric tool, ultrasonic cutter, reveal a high accuracy up to 93.7 %. Conclusion: In this study, we ensured the possibility of CNN in distinguishing electric tools contacting with the tissue, and confirmed that the proposed method has not only overcome the problem of missing trajectories which usually occurs in the convolutional long-short term memory method but also achieved a remarkable improvement of the accuracy with less limitation.

0.22
29

Personalized Digital Semantic Communication for Image Transmission with Vision-Language Models

eess.IV cs.MM ·2026-08-14 ·Nan Li, Li Zhou, Haijun Wang, Jun Xiong, Haitao Zhao +1 more
published
Abstract · Accepted by IEEE GLOBECOM 2026

Semantic communication (SC) enables bandwidth-efficient wireless image transmission, but most existing SC schemes are user-agnostic and ignore receiver-dependent semantics. To address this issue, we propose a personalized digital semantic communication (PDSC) framework that integrates a vision-language model (VLM)-based semantic encoder with a latent diffusion model (LDM)-based semantic decoder. Specifically, the semantic encoder extracts source-aware personalized semantic tokens from both the source image and the receiver's historical interactions. These tokens are vector-quantized into discrete semantic indices and further encoded into a compact fixed-length bitstream, enabling compatibility with digital transmission. At the receiver, the semantic decoder reconstructs a personalized image conditioned on the recovered semantic tokens. Furthermore, we formulate a capacity-constrained personalized semantic rate-distortion problem and introduce a semantic distortion metric that jointly characterizes source-semantic fidelity and user-preference alignment. Experiments show that PDSC achieves superior source-semantic consistency and personalization over state-of-the-art SC baselines, including CDDM and MoS, under bandwidth-limited wireless transmission.

0.22
30

Dual-Branch State-Displacement Network for Sea Surface Temperature Super-Resolution

eess.IV cs.CV ·2026-08-15 ·Wankun Chen, Feng Gao, Yanhai Gan, Chuanzheng Gong, Xun Gong +2 more
published
Abstract · Accepted for publication in IEEE JSTARS

Sea surface temperature (SST) is a critical indicator of global climate change, yet satellite-derived SST imagery often suffers from coarse spatial resolution, limiting the ability to capture fine-scale thermal structures such as ocean fronts. To address this, we propose a Dual-Branch State-Displacement Network (DBSD-Net) for SST super-resolution. DBSD-Net adopts a dual-branch architecture: a wavelet frequency branch that explicitly separates low and high-frequency components via discrete wavelet transform for targeted processing, and a VGGUNet branch that extracts multi-scale semantic features from a frozen pre-trained VGG backbone. Within the wavelet branch, we introduce a Structural State Space Module (SSSM) with a Gated Structure Refinement (GSR) unit to efficiently capture long-range dependencies and enhance structural integrity, and a Displacement Gate Module (DGM) that learns a displacement field for geometry-aware modulation of high-frequency details, thereby mitigating spatially varying degradation. Experiments on multiple public SST datasets demonstrate that DBSD-Net outperforms existing state-of-the-art methods.

0.20
31

Disentangling Co-Occurring Retinal Pathologies with Saliency-Guided Sparse Expert Routing

cs.CV cs.LGeess.IVeess.SP ·2026-08-10 ·Nagur Shareef Shaik, Jeongwoo Park, Yeong-Jin Kim, Jaeuk Jung, Hyunjung Oh +1 more
publishedbenchmark
Abstract · Accepted at 2026 IEEE International Workshop on Machine Learning for Signal Processing

Retinal fundus images frequently exhibit multiple co-occurring pathologies, yet standard deep learning classifiers apply static, identical computation to every image regardless of the underlying disease distribution. We propose a novel architecture that resolves this via sparse conditional computation, pairing a Guided Context Gating (GCG) spatial attention front-end with a sparsely-routed Mixture-of-Experts (MoE) block operating over feature tokens. Crucially, this routing yields an interpretable, data-driven decomposition. Expert allocation is significantly disease-dependent (p < 0.001), with the healthy Normal state and morphologically distinct pathologies (e.g., ERM, AMD) isolating to dedicated experts. On a five-class, patient-disjoint 5-fold cross-validation benchmark, our model achieves 0.912 +/- 0.008 macro AUC and 0.653 +/- 0.014 macro F1. Furthermore, Grad-CAM++ and post-MoE t-SNE visualizations confirm that expert routing aligns with localized lesions and geometrically maps co-occurring cases between their constituent clusters, positioning sparse MoE as an interpretable approach to multi-disease retinal screening.

0.20
32

C$^2$A: Coupling Spatial Evidence with Clinical Priors via Co-occurrence Aware Class Attention for Multi-Label Chest X-Ray Classification

cs.CV cs.LGeess.IVeess.SP ·2026-08-10 ·Akash Gogineni, Nagur Shareef Shaik, Aasrith Mandava, Adnan Masood, Dong Hye Ye
published
Abstract · Accepted at 2026 IEEE International Workshop on Machine Learning for Signal Processing

Thoracic pathologies rarely occur in isolation, yet standard multi-label classifiers rely on shared global descriptors, discarding \emph{where} findings lie and \emph{how} they co-occur. We propose \textbf{C$\mathbf{^2}$A} (Co-occurrence Aware Class Attention), a classification head that explicitly couples spatial evidence with clinical priors. First, C$^2$A casts pooling as an expectation over learned per-class spatial attention maps, yielding localized descriptors for each disease. Second, it couples these descriptors via a learnable graph warm-started from empirical label co-occurrence. A single residual message-passing step shares evidence among related findings, proving to be a bounded perturbation of the identity where co-occurrence enters each logit through an explicit bilinear interaction. On CheXpert, C$^2$A achieves a superior $0.895$ macro-mean AUROC, outperforming advanced context-gating baselines. Crucially, gains concentrate on highly co-occurrent classes with ambiguous spatial evidence (rescuing Atelectasis by $+1.5$ over GCG), demonstrating the prior's regularizing effect with a negligible overhead of one linear projection and a $C\!\times\!C$ edge matrix.

0.20
33

From Synthesis to Removal: Physics-Grounded Reflection Simulation and Diffusion-Based Video Dereflection

cs.CV cs.AIeess.IV ·2026-08-12 ·Zepeng Wang, Jiagao Hu, Fuhao Li, Yuxuan Chen, Fei Wang +1 more
benchmarkcode/data
Abstract · Project page: https://codingwzp.github.io/VideoDereflection_S2R

Videos captured through glass often contain reflections that degrade visual quality and interfere with downstream vision tasks. Although single-image reflection removal has been extensively studied, video reflection removal remains largely underexplored due to the lack of paired video data, temporally coherent removal models, and dedicated evaluation benchmarks. We present a closed-loop framework that unifies physics-grounded reflection simulation, diffusion-based video dereflection, and benchmark evaluation. Our S2R-Synthesis pipeline generates paired reflected and reflection-free videos by performing physics-grounded augmentation in the structure space and rendering realistic reflected videos with a trained video diffusion renderer; the augmentation models key glass-related effects including roughness-induced blur, thickness-induced ghosting, and reflectance variation. Based on the synthesized data, we introduce S2R-Removal, the first diffusion-based video reflection removal model, which adapts a pretrained video diffusion prior through reflection-aware latent adaptation and one-step pixel-geometric refinement, recovering the clean transmission in a single denoising step. We further build S2R-Bench, the first benchmark for video reflection removal, supporting both full-reference evaluation and real-world human perceptual assessment. Experiments on S2R-Bench and multiple public image benchmarks demonstrate state-of-the-art performance and faster inference than even non-diffusion baselines, and validate the effectiveness of S2R-Synthesis. Project page: https://codingwzp.github.io/VideoDereflection_S2R.

0.20
34

Few-Shot Ordinal Learning for Day-Wise Freshness Estimation with Hyperspectral Fish Images

cs.CV cs.AIeess.IVeess.SP ·2026-08-12 ·Kazi Nabiul Alam, Pooneh Bagheri Zadeh, Akbar Sheikh-Akbari
published
Abstract · Accepted at EUSIPCO'2026

Non-destructive food quality assessment has increasingly benefited from hyperspectral imaging (HSI), which captures spectral signatures linked to biochemical changes during storage. Estimating day-wise freshness, however, remains challenging owing to strong inter-fillet variability and scarce labelled data per product. All existing deep learning approaches for HSI-based freshness prediction operate under full supervision, requiring densely annotated training sets that are costly to obtain at the individual-product level. We introduce, to the best of our knowledge, the first few-shot learning framework for HSI-based food quality estimation. Each fillet defines a distinct episodic task, and a CORAL-style ordinal prediction head captures the ranked nature of freshness progression through cumulative threshold modelling. Biologically grounded monotonicity and embedding smoothness constraints further guide predictions toward plausible trajectories. On a 16-day salmon HSI dataset under a strict unseen-fillet protocol, our method achieves a mean absolute error of 1.58 days and 2-day accuracy of 72.3% with only three labelled days per fillet, substantially outperforming scalar regression and label-distribution baselines under an identical unseen-fillet protocol.

0.19
35

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19
36

A Subjective Study on a New Sharpness Informed Class of Metrics

eess.IV cs.CV ·2026-08-14 ·Uditangshu Aurangabadkar, Vibhoothi Vibhoothi, Darren Ramsook, Anil Kokaram
publisheddataset
Abstract · Accepted at IEEE MMSP 2026, 6 pages

Perceptual loss functions in Deep Neural Network (DNN) deblurring architectures improve the overall quality of restored images. However, few focus on explicitly targeting sharpness in the restorations. We conduct a subjective study of models trained with and without losses which explicitly target sharpness using a four-protocol approach, exploring preferred sharpness levels and effects on image quality. We introduce a novel dataset of images with uniform sharpness increments along with Difference Mean Opinion Scores (DMOS). Additionally, we propose a novel class of Sharpness Informed (SI) Image Quality Assessment (IQA) metrics which properly penalize over-sharpening. Our new SI-PSNR metric outperforms all other PSNR variants in terms of correlation statistics on IQA benchmarking datasets. We show that, on average, images restored using a sharpness-aware composite loss are preferred in 67% of binarized comparisons, as opposed to losses that do not explicitly target sharpness.

0.19
37

BreastMammo and DenseMammo: Benchmarks for Mammography Domain Generalization

eess.IV cs.LG ·2026-08-10 ·Hongyi Pan, Gorkem Durak, Halil Ertugrul Aktas, Andrea Mia Bejar, Mustafa Ege Seker +16 more
published
Abstract · This paper was accepted to the MICCAI 2026 workshop Deep-Brea3th

Breast density classification is a critical component of breast cancer risk assessment, yet AI models often struggle to generalize across clinical sites due to vendor-specific acquisition styles. In this work, we introduce two new datasets, BreastMammo and DenseMammo, to facilitate robust multi-view mammography research. We propose a domain generalization framework that utilizes a foreground-only histogram matching protocol to resolve the domain shift issue arising from disparate clinical sources. Internal evaluation using a 5-fold cross-validation protocol demonstrates the efficacy of our approach, with the Swin Transformer backbone achieving a peak AUC of 98.32% for density classification. External evaluation on the TNMammo and LUMINA datasets demonstrates that the proposed approach consistently reduces domain shift, significantly outperforming prominent domain generalization paradigms, including MixStyle and Discrete-Fourier-Transform-based frameworks.

0.18
38

A Unified DINOv2-Based Framework for LVEF Estimation, GLS Dysfunction Classification, and Early Cardiotoxicity Prediction

eess.IV cs.CV ·2026-08-14 ·Xiaotong Zhang, Mingyue Cui, Qing Cao, Jingming Xia
published
Abstract · Accepted as an oral at the EchoRisk Challenge Workshop, MICCAI 2026

Left ventricular ejection fraction (LVEF) estimation (Task 1), global longitu-dinal strain (GLS)-based dysfunction classification (Task 2), and early cardi-otoxicity prediction (Task 3) provide complementary information for cardio-oncology assessment. LVEF reflects macroscopic ventricular volume chang-es as the clinical standard, whereas GLS captures subtle myocardial defor-mation, indicating subclinical cardiotoxicity before overt LVEF decline. Fur-thermore, predicting cardiotoxicity from baseline echocardiography prior to treatment enables preventive interventions at an early stage. To address these three tasks, we employ a DINOv2-based framework with task-specific adap-tation and prediction heads. Built upon a frozen foundation encoder, the framework incorporates parameter-efficient Low-Rank Adaptation (LoRA) and temporal aggregation to learn task-specialized representations, ensuring robust generalization. Crucially, during inference, it operates in a fully cycle-detection-free and phase-free manner, requiring neither cardiac cycle seg-mentation nor explicit End-Diastolic/End-Systolic (ED/ES) annotations. Ad-ditionally, we introduce an ED/ES-guided 2D/3D hybrid multi-view regres-sion model specifically to optimize Task 1. On a patient-level split containing 1,203 training videos from 237 patients and 300 validation videos from 59 independent patients, the DINOv2-based framework achieved a mean abso-lute error (MAE) of 5.03% for Task 1, an AUC-ROC of 76.48% for Task 2, and an AUC-ROC of 70.26% for Task 3. For Task 1, the specialized ED/ES-guided model further improves performance, achieving an MAE of 4.64%. This framework demonstrates the effectiveness of foundation model repre-sentations across diverse cardio-oncology tasks and the additional benefit of physiology-guided modeling for accurate LVEF estimation.

0.18
39

Modality-Invariant Coarse-to-Fine Retinal Image Registration

eess.IV cs.CV ·2026-08-14 ·Bo Wen, Nehal Nailesh Mehta, Melanie Tran, Dirk-Uwe Bartsch, William Freeman +1 more
published
Abstract · This paper is a submission to IEEE Transactions on Image Processing (TIP-40498-2026)

Retinal image registration is essential for ophthalmic diagnosis, longitudinal disease monitoring, and multimodal retinal image analysis. Existing retinal registration methods are typically modality-dependent: they are designed or optimized either for a single imaging modality in mono-modal registration or for a fixed pair of modalities in cross-modal registration. This limits their flexibility and applicability in practical scenarios involving diverse retinal imaging modalities and different combinations of them. In this work, we propose a generalizable two-stage, modality-invariant framework for retinal image registration. First, we introduce a sparse feature-matching model driven by a universal retinal vessel segmentation to achieve robust coarse global alignment across modalities. Second, we develop a modality-invariant optical flow estimation network, termed MI-RAFT, to refine the alignment through dense local registration. Extensive experiments demonstrate that the proposed method can handle diverse combinations of commonly used retinal imaging modalities, exhibiting strong modality invariance while outperforming state-of-the-art modality-dependent registration methods.

0.17
40

CW-BASS v2: Saturation-Aware Pseudo-Label Selection for Semi-Supervised Segmentation under Foundation-Model Teachers

cs.CV cs.LGeess.IV ·2026-08-13 ·Ebenezer Tarubinga
Abstract · Submitted to IEEE TPAMI. 22 pages, 11 figures, 17 tables

Semi-supervised semantic segmentation has long turned on one question, which pseudo-labels to trust, and a generation of selection rules, dynamic thresholds, per-class curricula, soft confidence weights, answered it for the noisy, under-confident ResNet teachers of their day. Self-supervised foundation encoders change the regime: with a DINOv2 teacher, confidence saturates, so the filtering that helped a weak teacher can hurt a strong one. We propose CW-BASS v2, a saturation-aware pseudo-label selection method that reads the teacher's confidence regime rather than committing to one rule. It pairs held-out calibration, an unbiased per-class noise estimate, with a self-adaptive confidence floor that provably bounds retention away from 1, and combines them in a one-pass gate: measure the reliability of the teacher's confident set, pi_kept = Pr[correct | c >= tau], on a held-out slice, and filter strictly when it meets the confidence demanded (pi_kept >= tau), falling back to the adaptive floor otherwise. The boundary is the pre-existing operating threshold, not a value tuned to mIoU, and across six DINOv2 teachers it makes the correct strict-vs-floor call blind. CW-BASS v2 thus recovers the UniMatch V2 operating point on the saturated benchmarks by selecting strict (Pascal VOC 1/8 87.4 against its reported 87.9; Cityscapes within 0.5), and improves on it where the confident set is unreliable (pi_kept ~ 89%, ADE20K), where the floor edges ahead (+1.5 mIoU, single seed). The gate is principled because the failure it avoids is measured, not assumed: on a reliable, saturated teacher the confidence distribution's dynamic range collapses (98% of Pascal pixels >= 0.95), so an adaptive cutoff floods the retention mask and self-training decays into confirmation bias.

0.12
41

Structure-Enhanced Features and Quality-Aware Dynamic Anchor Scoring for Robust Lane Detection

cs.CV cs.AIcs.LGeess.IV+1 ·2026-08-10 ·Weize Cai, Yongqi Dong, Zhida Shao, Yichen Liu, Zixin Fu
Abstract · 17 pages, 5 figures

Lane detection requires recovering thin, elongated, and frequently occluded lane structures under challenging driving conditions. While anchor-based detectors provide efficient candidate generation, their performance is limited by two coupled issues: backbone features often lose structural continuity along partially visible lanes, and classification confidence may decouple from line-level localization quality, allowing inaccurate anchors to persist before non-maximum suppression (NMS). We propose a structure-enhanced and quality-aware framework that improves lane representation and dynamic-anchor scoring while preserving the inference pipeline of the Anchor Decomposition Network (ADNet). Specifically, a Gated Horizontal-Vertical Token (GHVT) module enhances mid- and high-level backbone features via lightweight directional token interactions with a learnable residual gate. In parallel, Line-Quality-Aware Dynamic Anchor Scoring (LQAS) calibrates existing classification logits using quality supervision, hard-negative suppression, and pairwise ranking without adding inference branches. On the VIL-100 dataset, our method improves ADNet-R34 from 89.97 to 91.28 in F1 score at the 0.5 intersection-over-union threshold (F1@50), reducing both false positives and false negatives. Additional experiments on CULane and TuSimple datasets, extensive ablations, score-distribution diagnostics, and runtime analysis confirm complementary structural and ranking improvements with minimal computational overhead.

0.10
42

Generative Semantic Segmentation via an Observable Semantic-Image Interface and Hierarchical Generator Evidence Alignment

cs.CV cs.AIcs.LGeess.IV ·2026-08-12 ·Weize Cai, Yongqi Dong, Zhida Shao, Zixin Fu
Abstract · 15 pages, 4 figures

Generative semantic segmentation exposes structured predictions as images, but direct color decoding is susceptible to color drift and boundary mixing, whereas latent-feature decoders that predict a separate output distribution may relegate the rendered image to an intermediate visualization. We present Semantic Prism, a conditional semantic-image generation-and-refinement framework with deterministic inference. A diffusion-distilled one-step generator renders a semantic RGB image; per-pixel distances from the rendered colors to a fixed class-color codebook define an explicit probabilistic interface. Hierarchical Generator Evidence Alignment spatially aligns multi-level generator features and uses a zero-initialized output projection to predict an additive residual in the interface logit space, retaining the image-defined interface as the reference for the final distribution. The interface and refined distributions further enable Contextual Interface--Hierarchy Disagreement (C-IHD), a fixed readout for ranking remaining pixel errors without an auxiliary predictor or additional forward pass. On the 500-image Cityscapes validation set, Semantic Prism achieves 72.07% mean intersection over union, 11.39 mIoU points above direct-interface decoding, with 0.41% expected calibration error. Matched-capacity ablations over three seeds support the benefit of jointly aligned multi-level evidence. A separately trained model attains 62.22% mIoU on BDD100K, while the Cityscapes-trained model reaches 46.89\% mIoU under source-frozen transfer to the Adverse Conditions Dataset with Correspondences, without target-domain adaptation. Across all three datasets, C-IHD consistently improves the area under the precision--recall curve for pixel-error ranking over maximum softmax probability on the same segmentation predictions; on ACDC, it raises AUPR from 0.6580 to 0.7557.

0.10
43

Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening

eess.IV cs.AIcs.CVcs.LG ·2026-08-14 ·Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant +1 more
Abstract · 17 pages, 11 figures, 6 tables

Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement. Fetal brain MRI provides more reliable volumetric information but is costly and less accessible for routine use. To address these limitations, we propose VIFBA, an ultrasound video-based framework for fetal brain assessment that predicts MRI-derived lateral ventricular volume, classifies VM severity, and identifies potential non-VM fetal brain abnormalities. Our contribution is three-fold. First, we introduce a joint-embedding predictive architecture (JEPA)-inspired tube latent prediction objective that leverages spatio-temporal coherence in ultrasound videos to enhance representation learning. Second, we develop a contrastive cross-modal alignment strategy that transfers structural information from MRI to ultrasound during training, while requiring ultrasound alone at inference. Third, we augment VIFBA with a training-free vision-language model and retrieval augmentation to verify uncertain predictions and identify potential non-VM fetal brain abnormalities. We validated VIFBA on a large dataset comprising 857 cases (3,196 videos) with paired fetal brain ultrasound and MRI examinations. On held-out test data, VIFBA achieved an MAE of 0.5909 mL and Pearson correlation coefficient of 0.9907 for ventricular volume regression, 0.9400 accuracy for VM severity classification, and an F1 score of 0.7764 for multi-abnormality classification, substantially outperforming single-task baselines, video-based strong competitors, and state-of-the-art foundation models. By enabling MRI-informed volumetric assessment from routine ultrasound alone, VIFBA offers a practical and potentially broadly deployable pathway toward accurate and affordable prenatal brain screening.

0.10
44

Deep learning-based computed tomography (CT) derived body composition classifier for colorectal cancer patients

eess.IV cs.LG ·2026-08-16 ·Eve Harling, Chattarin Pumtako, Bernd Porr, Donald C McMillan, Ross D Dolan
Abstract · 27 pages, 4 figures

Background: Accurate body composition analysis using Computed Tomography (CT) scans is essential for assessing skeletal muscle area (SMA) and skeletal muscle density (SMD), key markers of nutritional status in cancer patients. Conventional manual methods are labour-intensive and require specialist expertise, limiting their routine clinical use. Therefore, this study serves as a feasibility and pilot investigation to explore the potential of deep learning-based automated regression for body composition analysis within a clinical workflow. Methods: Four deep learning architectures (AlexNet, UNet, GoogLeNet, and ResNet34) were trained to predict SMA, SMD, subcutaneous fat area (SFA), and visceral fat area (VFA) from CT scans of colorectal cancer patients. Systematic hyperparameter optimization identified the most accurate models, which were subsequently implemented in a web application for clinical use. Results: GoogLeNet achieved the best performance, with a mean percentage error (PE) of 4.96% for SMA prediction, while AlexNet reached 8.12% for SMD. Independent testing demonstrated robust accuracy, correctly classifying body composition metrics in 80% of cases. The web application delivered rapid and consistent outputs, supporting integration into clinical workflows. Conclusion: Optimized deep learning models, particularly GoogLeNet and AlexNet, can automate CT-derived body composition analysis with a Mean Percentage Error (PE) of 4.96% for SMA and 8.12% for SMD. These tools have the potential to streamline clinical practice by reducing the time and expertise required for manual segmentation. Further validation in larger, more diverse datasets is warranted.

0.10
45

Bright-Channel Retinex Enhancement with a Conditional Overdispered-Noise Analysis

cs.CV eess.IV ·2026-08-10 ·Jongpil Jeong
Abstract · 5 pages, 3 figures, 2 tables

I present a training-free low-light enhancement method that combines local bright-channel illumination estimation, Retinex division, and edge-preserving denoising. For a fixed illumination estimate, a conditional Negative -Binominal psueduo-count method characterises the heteroscedastic noise amplified by division. The unconstrained reflectance ratio is the pixelwise maximum-likelihood estimate, with a boundary solution for zero-valued observations; the implemented estimate additionally applies illumination filtering and range clipping. The NB model is a diagnostic noise analysis rather than a calibrated sensor model, and the final fixed-bandwidth bilateral filter is an empirical approximation rather than the exact Bayesian solution. On the LOL-v1 dataset, the methodobtains mean PSNR/SSIM of 17.74dB/0.739, the highest values among the evaluated with conventional methods. A 400X600 image is processed at approximately 43 FPS on an Apple M2 Pro CPU.

0.07
46

Uncertainty-Aware and Explainable Ensemble Deep Learning Framework for Multi-Class Skin Lesion Classification

eess.IV cs.AIcs.CVcs.LG ·2026-08-11 ·Rofiqul Islam, Lilatul Ferdouse
Abstract · 5 pages, 3 figures, IEEE AIBThings 2026

Skin cancer diagnosis from dermoscopic images remains challenging due to high intra-class variability, inter-class similarity, class imbalance, and the limited interpretability of deep learning models. This paper proposes an uncertainty-aware and explainable deep learning framework for multi-class skin lesion classification. The framework combines a vision transformer model (MaxViT-Tiny) with CNN-based models (ConvNeXt-Tiny and EfficientNetV2-B0) through deep ensemble learning. Monte Carlo (MC) Dropout estimates predictive uncertainty and identifies unreliable predictions, while Grad-CAM++, an explainable AI (XAI) technique, provides visual explanations by highlighting lesion regions that influence model decisions. Evaluated on the HAM10000 dataset, the framework achieves 96% accuracy and 99% ROC-AUC under uncertainty-aware filtering (entropy < 1.0, confidence >= 0.7), with macro-average precision, recall, and F1-score of 94%, 95%, and 95%, respectively, and 96% weighted-average scores across all three metrics. The results demonstrate accurate, interpretable, and uncertainty-aware skin lesion classification for trustworthy computer-aided diagnosis.

0.07
47

Deep Learning based Detection of Fishing Vessels and Fishing Monitoring using Nightlight Images

cs.CV cs.AIcs.LGeess.IV+1 ·2026-08-10 ·Shantakar Mohanty, Prasun Kumar Gupta, Raian Vargas Maretto
Abstract

The demand for maritime surveillance has given rise to the need for monitoring fishing vessel activities, particularly in addressing the challenge of "dark vessels" that operate without Automatic Identification System (AIS) transmission. This study presents a novel approach for detecting small-scale fishing vessels using nighttime light (NTL) imagery from the SDGSAT-1 satellite, combined with deep learning techniques to enhance fishing monitoring awareness along the western coast of India. A dual-branch YOLO11 architecture was developed to exploit both the 10-meter panchromatic and 40-meter RGB imagery from SDGSAT-1. The custom model architecture was specifically optimized for small object detection in NTL imagery, featuring parallel convolutional backbones that process both modalities before concatenation for enhanced feature extraction. The dual-branch YOLO11 model demonstrated optimal performance with a precision of 0.99, recall of 0.93, F1-score of 0.96, and mAP@50 of 0.96, significantly outperforming single-branch implementations of YOLOv5s, YOLOv8s, and standard YOLO11s architectures. When applied to the western coast of India, the model detected 31525 vessel instances across the temporal dataset spanning 2022-23. Cross-matching analysis with AIS data revealed that only 7146 (22.7%) of detected vessels had corresponding AIS transmissions, while 24379 (77.3%) were identified as potential dark vessels. Spatio-temporal analysis showed peak fishing activity during January-April, with a primary activity corridor parallel to the coastline within 50-100 km, corresponding to productive continental shelf areas. This research contributes to maritime surveillance capabilities by highlighting the effectiveness of nighttime lights satellite imagery for fishing vessel detection and provides valuable insights into fishing patterns and potential regulatory compliance issues in Indian waters.

0.04
48

Unrolling a Graph-Laplacian Denoiser Realizes Only Compositions of Polynomial Graph Filters

eess.SP eess.IV ·2026-08-10 ·Seyed Alireza Hosseini
theory
Abstract

A recent construction of unrolled networks for graph-based image restoration forms a system matrix from a graph-Laplacian denoiser through a truncated Taylor expansion, then inverts it with a fixed number of conjugate-gradient steps, with the coefficients of both stages learned. This paper shows the resulting map is a polynomial in the denoising operator, of degree at most the product of the two truncation orders, for every setting of those coefficients and therefore at every point of training: the learned steps select an element of a Krylov subspace they cannot enlarge. At the orders used in practice the reachable set is moreover a measure-zero subset of the polynomial class of the network's own degree budget, so the composition constrains the hypothesis space rather than enlarging it. At the standard initialization the realized spectral response is obtained in closed form, exceeding the intended response throughout the interior of the spectrum and approaching a nonzero floor. A lower bound on the operator's condition number, internal to the graph construction rather than to image content, then places the order required for a prescribed accuracy well above the order used in practice. The confining class is precisely the spectral graph filters for which a direct, convex parameterization has long been available.

0.04
49

Media-over-Multipath-QUIC for Realtime Video Applications

cs.NI cs.ETcs.MMeess.IV ·2026-08-11 ·Tanya Shreedhar, Zuji Zhou, Nitinder Mohan, Fernando Kuipers
Abstract · In review

Multipath transports place a client's WiFi, cellular, and satellite networks under one connection, yet real-time video gains little from them. The scheduler that assigns packets to paths sees only bytes, so it cannot tell a keyframe that anchors a second of video from an enhancement frame whose loss costs one image. We show that the limiting factor is not a shortage of path diversity but the absence of a channel through which the application can name what the transport cannot see. Media over QUIC Transport (MoQT), already deployed on production CDNs, carries media as named Objects, and relays forward each Object's metadata without interpreting it. The knowledge the scheduler lacks therefore already flows through the subscriber's relay. We present MoMQ, a MoQT extension that turns this metadata into path decisions. Applications and relay operators install declarative rules at the edge relay that match Object metadata and express delivery preferences against labeled paths. The relay evaluates the rules mechanically, so it acts on video semantics while containing no video logic. On a live testbed spanning Starlink and WiFi, four rules cut P99.9 frame completion time from 384.7 ms under the best transport-only scheduler to 114.1 ms and reduce the required playback buffer by 61.5%. MoMQ is the only configuration that meets the 150 ms interactive latency target. Across relays in two countries and subscribers on two continents, the same rules apply unchanged and retain their advantage wherever the paths remain disjoint.

0.04
50

Decodable but Not Accessible: Auditing Distance-Based Reliability Estimation on Disentangled Skin-Lesion Representations

eess.IV cs.CV ·2026-08-10 ·Duc-Vinh Tran
Abstract

Distance-based reliability estimation assumes that a representation's geometry reflects its trustworthiness, yet this assumption is rarely tested under training interventions that reshape geometry directly. We audit this assumption under domain-adversarial representation learning using a disentanglement dose-response ladder. Three checkpoint families share the same architecture and a 16-dimensional representation, differing only in orthogonality strength (lambda = 0, 1, 5). Representation geometry changed substantially with disentanglement strength: the condition number shifted by two orders of magnitude (Kendall tau = 0.84, exact p = 2.8e-5). This change was not accompanied by improved reliability estimation: Mahalanobis-distance AUROC (ISIC-test vs. PAD-UFES) remained flat and below chance (about 0.40) at every level, with no significant association with any of five geometry metrics tested. The same failure was observed for cosine-to-centroid and pooled k-nearest-neighbor scorers, plus three non-distance-based scorers: an energy-based confidence score, Virtual-Logit Matching, and a kernel density estimator. Seven of eight scorers converged on the same result; the energy-based score showed an isolated upward trend that we report but do not treat as evidence against the overall pattern. A supervised probe with no access to the training objective recovered domain membership from the identical embeddings at 0.72-0.81 AUROC across every level, showing that the relevant information was not absent from the representation. These findings indicate that classification performance alone can overlook whether information in a learned representation is organized in a form that downstream reliability estimators can use. Information can remain decodable while becoming largely inaccessible to non-probing reliability estimators.

0.04