AI & Machine Learning 2

Speed-to-Power Dominates Energy Costs for AI Data Centers: Technoeconomic Analysis of Powering AI in the Continental United States

cs.AI eess.SY ·2026-11-12 ·Alex C. Newkirk, Daniel L. Gerber, Erica R. H. Fuchs, Alex Hubbard, M. Granger Morgan +3 more
code/datahot direction
Abstract · 80 pages incl. SI

The rapid growth of artificial intelligence is driving demand for new data centers at large scale and on short deployment timelines. To power them, firms connect to the commercial grid or contract generation directly, but interconnection and gas-turbine delays now incentivize on-site generation. We compare grid-connected and off-grid data center energy infrastructure (AC- and DC-coupled solar-plus-storage, islanded natural gas, and grid interconnection) across the continental U.S. Using an open-source technoeconomic framework built on empirically calibrated AI training loads, climate-driven cooling, stage-by-stage power conversion, and physics-based battery degradation, we model designs providing equivalent energy services. Our central contribution is a speed-adjusted cost of energy that values the compute unlocked by faster construction, making options with different deployment timelines directly comparable on one physically consistent basis. We find DC coupling reduces lifetime energy costs by 18% ($0.09/ kWh) on average versus AC counterparts by eliminating inverters and improving efficiency. Though rarely cheapest on unadjusted energy cost, DC-coupled microgrids' faster deployment makes them the lowest-cost modeled option in 85% of U.S. locations once foregone compute is valued, or 55% under accelerated natural gas timelines. For AI infrastructure, deployment speed rather than unit energy cost determines the economically preferred path to power.

0.30

Fair and Efficient Distributed EV Charging Coordination Using Threshold Cryptography and Machine Learning

cs.LG cs.CReess.SY ·2026-11-12 ·Md. Mainul Islam, Muhammad Ismail, Hasan Kurban, Abdulrahman Takiddin, Erchin Serpedin
theory
Abstract · 16 pages

Distributed coordination of electric vehicle (EV) charging with the alternating direction method of multipliers (ADMM) keeps EV constraints private but assumes that every participant follows the algorithm. This assumption fails in practice, where a biased operator or a man-in-the-middle (MITM) attacker can send inconsistent signals to different EVs, and compromised EVs can deviate from their prescribed updates. We first prove that attacks by such arbitrarily malicious, i.e., Byzantine, participants do not prevent convergence and therefore remain undetected, and derive the most damaging attack in closed form. We then propose a framework that combines a threshold-signed broadcast with upload recomputation, which detects every deviation without false alarms at linear instead of quadratic communication cost. To keep the optimization running, each affected EV recovers locally with a certified, fleet-aware machine learning price forecast, and we prove that the optimization remains convergent with a recovery cost bounded by the shape of the forecast error. Simulation results with real-world load, price, and charging data show that a biased operator raises the annual cost of disadvantaged EVs by 132.7% and lowers that of advantaged EVs by 49.3% without changing the aggregate load, whereas the defense limits all cost changes to 2.6%. An external MITM attacker raises the cost of its victims by 57.6%, the peak load by 5.8%, and the grid cost by 15.8%, whereas the defense keeps them within 1.1%, 0.2%, and 0.3% of benign operation. With up to 70% of the EVs attacked, the recovery converges in at least 97.8% of the runs.

0.20

Theory & Algorithms 2

Strategically Robust Multi-Agent Control

cs.GT math.OCeess.SY ·2026-11-12 ·Boris Velasevic, Nicolas Lanzetti, Eric Mazumdar
Abstract · 16 pages, 10 figures, 3 tables

A key source of uncertainty in multi-agent systems is the behavior of other agents. Game-theoretic control approaches ignore this uncertainty, while robust control approaches treat others as fully adversarial. In this paper, we introduce strategically robust multi-agent control to populate the spectrum between these two paradigms. Specifically, in dynamic games, we propose that players are strategically robust and seek protection against misspecified control policies of the other players. This formulation induces a novel equilibrium concept, strategically robust dynamic equilibrium, that interpolates between game-theoretic control and robust control. We study this concept across canonical open- and closed-loop settings and show that accounting for strategic robustness also has computational benefits over classic approaches in game-theoretic control. Numerical experiments on vehicle platooning, inventory management, and network control illustrate resilience to misspecification, and also exhibit a "free-lunch" phenomenon in which strategic robustness can improve performance or social welfare.

0.14

Fictitious Play When Agents Are Not Expected-Utility Maximizers: A Geometric Analysis in $2$-Action Games

cs.GT eess.SYmath.OC ·2026-11-12 ·Hao Liang, Solaleh Mohammadi, Kaiqing Zhang
Abstract

Fictitious play (FP) is one of the earliest and most fundamental learning procedures in games, where each agent independently chooses a best response to the empirical distribution of opponents' past actions by maximizing the expected payoff with respect to it. However, learning agents may not always be expected-utility maximizers: they may use nonlinear evaluation functionals to account for the uncertainty induced by the opponents, e.g., via risk measures. In this work, we study nonlinear fictitious play (NL-FP), in which each pure action is evaluated by a general, possibly nonlinear functional of the payoff distribution induced by the opponent's empirical belief. To analyze NL-FP, we first identify a single-crossing property (SCP) of evaluation functionals that preserves the classical geometry of FP in $2\times2$ games. Furthermore, we conduct a novel geometric analysis of the convergence behavior of NL-FP in $2\times2$ games, even when the SCP fails. Beyond $2\times2$ games, we show that the convergence of NL-FP in $2\times n$ ($n\ge3$) games may fail even for continuous-time NL-FP, when the two-action player uses conditional value-at-risk (CVaR) in a $2\times3$ game. In addition, we identify a finite-crossing condition that ensures convergence of the selected continuous-time dynamics and the discrete-time iterates in general $2\times n$ games, which also provides new insights into the global landscape of continuous-time classical FP in such games.

0.13

Robotics, Control & Signals 34

GridForge: A Tractable Network-Flow Method for Constructing Open, Continental-Scale Synthetic Power Grids

eess.SY ·2026-11-12 ·Jonathan M. Snodgrass, Thomas J. Overbye, Christopher L. DeMarco, Bernard C. Lesieutre
Abstract · 30 pages, 10 figures, 7 tables; supplementary material as an ancillary file. Submitted to the International Journal of Electrical Power & En…

The goal of this paper is to construct open, continental-scale synthetic transmission grids with an optimization method that stays tractable. Security restrictions keep models of the real grid out of open research and machine-learning datasets, and optimization-based construction is hard at scale: the number of candidate lines grows combinatorially, so electrically faithful methods prune the candidates in advance. This paper presents GridForge, which keeps every bus pair within physical length limits as a candidate, selects lines with Garver's length-weighted network-flow linear program instead of binary decisions, and resizes them with a sequential direct-current (DC) power flow. Two stages of 13 regional networks are evaluated. Their node-degree distributions are nearly as strongly log-linear as those of the real Eastern and Western Interconnections ($R^2$ of 0.92 to 0.98 against 0.971 and 0.981), although the areas under the fitted lines differ from the real ones by 39.9% on average. On the upper Midwest and Tennessee Valley footprints, resizing lowers the DC power-flow loss from 5.89% to 4.14% and from 14.55% to 7.05%, and the DC optimal power-flow loss from 4.03% to 2.02% and from 5.54% to 2.47%. Without relaxing any line limit, the DC optimal power flow is feasible in 78.81% and 0.82% of the scenarios. Most lines are built at 69 kV. The models span 250 to 78,484 buses, were built on single machines, and are freely redistributable.

0.62

Improved Single-Input Space Vector for DC-Biased Sinusoidal Current Control in Battery Cyclers

eess.SY ·2026-11-12 ·Manveer Aujla, Philip Lewoc, Harminderjit S. Toor, Ahmad Ali, Caniggia Viana +1 more
publishedunusual
Abstract · 8 pages, 17 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

This paper presents improvements to the single-input space vector (SISV) concept for current control in a battery cycler based on a two-phase interleaved buck converter. The cycler is controlled to output a dc-biased sinusoidal current, enabling investigation of second-harmonic ripple effects on lithium-ion cell aging. A modified SISV generation scheme is introduced to track current references containing both dc and sinusoidal components, and an impedance-angle compensation method is proposed to decouple the d and q control axes without disturbing dc tracking. A dq phase-portrait visualization method is also introduced to evaluate transient performance for both SISV and proportional-integral-resonant (PIR) control methods. Simulation and experimental results validate dc-biased sinusoidal current tracking using PIR control and SISV control with different decoupling schemes. The phase-portrait framework allows for straightforward evaluation of transient performance for both SISV and PIR control methods and supports controller tuning to obtain desired trajectories. The results demonstrate the feasibility of SISV-based current control as an alternative to PIR control for battery-cycler applications. The proposed improvements support the development of battery cyclers capable of controlling both dc and sinusoidal current components.

0.36

A Joint LLM and Optimization Agent Solution for Drone Scheduling in Victim Search Missions

eess.SY cs.AIcs.ET ·2026-11-12 ·Yinghao Zhang, Yalin Liu, Hong-Ning Dai, Yan Zhang, Qubeijian Wang +2 more
code/data
Abstract

Victim search in wilderness areas is time-critical. Drones enable rapid area search, but scheduling them is challenging because victims may continue moving, detection results are uncertain, and effective decisions must combine structured mission information with unstructured contextual clues and domain knowledge. To address this, we propose an agent-aided drone scheduling system. The system employs an agent at the ground control station (GCS) to coordinate multiple drones over successive search cycles. In each cycle, the agent applies a scheduling policy that combines a large language model (LLM) for reasoning about where to search with an optimizer for determining how to dispatch the drones under energy constraints. Simulation results show that the proposed system consistently completes the victim-search mission, whereas none of the six non-LLM baselines does so and direct LLM scheduling is considerably less reliable. The source code is publicly available at https://github.com/1643204431/llm-uav-victim-search.

0.34

A Modulation Strategy for Bidirectional Integrated Onboard and Wireless EV Charging

eess.SY ·2026-11-12 ·Manveer Aujla, Gavin Feher, Caniggia Viana
published
Abstract · 7 pages, 9 figures. Accepted version of a paper presented at the 2026 IEEE Energy Conversion Congress and Expo (ECCE), Vancouver, Canada

Integrated electric vehicle chargers reduce cost by sharing power conversion hardware between the onboard charger (OBC) and the wireless charger (WC). A previously proposed dual active bridge (DAB)-based OBC/WC shares the rectification stage between the OBC and WC; however, the modulation required to realize its wireless operation has not yet been reported. This paper details a modulation strategy that enables the operation of the integrated OBC/WC topology. Differential-mode operation is used for the OBC, and common-mode operation is used for the WC. In OBC mode, the shared full-bridge produces differential-mode voltage for wired power transfer while ideally generating zero common-mode voltage on the wireless charging path. In WC mode, the same full-bridge produces common-mode voltage for wireless power transfer while ideally generating zero differential-mode voltage on the onboard charging path. The method preserves conventional DAB phase-shift power control and enables bidirectional power transfer in wired and wireless charging modes without additional contactors. Design considerations for the OBC transformer and WC coils are derived based on the resulting square-wave voltage amplitudes. Offline PLECS simulations demonstrate power tracking and decoupled charger operation at $\pm$7.4 kW. Hardware-in-the-loop simulations using a PLECS RT Box and an external Texas Instruments microcontroller further validate the proposed modulation method.

0.34

Quantum Network Flows That Solve Linear Equations

eess.SY ·2026-11-12 ·Chengyang Jiang, Zihao Ren, Lei Wang, Guodong Shi
Abstract

We develop a distributed quantum network flow for solving linear equations from locally stored row data. Local pumping enforces each node's equation constraint, while neighboring registers interact through swaps. The node marginals obey an exact, closed flow combining consensus with local constraint enforcement. For consistent equations, all node states converge exponentially to a common state supported on the solution space; a unique solution yields full-network convergence to the product solution state. For inconsistent equations of full column rank, scaled encoding and readout recover the least-squares solution through successive large-gain and small-scale limits. For consistent systems, the marginal convergence rate is nondecreasing and concave in the swap gain, approaching a graph-independent limit for fixed local dissipators. Its leading finite-gain correction couples graph topology and row placement through the Laplacian pseudoinverse, enabling semidefinite optimization of edge rates under a fixed total swap-rate budget. For invertible systems, a dissipative HHL-type construction using the same pumping law provides a comparison of solution-state encodings, decay rates, and row-update locality under squared-row-norm pumping. Numerical examples are provided to validate the presented results.

0.31

Total Energy Shaping of Underactuated Systems via Gravity Compensation at the Desired Equilibrium

eess.SY ·2026-11-12 ·M. Reza J. Harandi, Mehrzad Namvar
Abstract

This paper investigates total energy shaping of underactuated mechanical systems with gravity compensation evaluated at the desired equilibrium instead of throughout the online closed-loop operation. Within the interconnection and damping assignment passivity-based control (IDA-PBC) framework, sufficient conditions for local asymptotic stability are established in terms of integrability of a vector field and positive definiteness of an augmented potential energy. The approach is also combined with a reformulation of potential energy matching that replaces a nonhomogeneous partial differential equation with a homogeneous one and introduces an additional design term. Analytic constructions for the TORA system and a class of two-degree-of-freedom systems illustrate how the matching and integrability requirements can be addressed. The proposed control law avoids online evaluation of the configuration-dependent gravity term; offline controller synthesis and verification can still require knowledge of the gravity model.

0.31

Velocity-Free Funnel Control of Euler-Lagrange Systems: An Artificial-Delay Approach

eess.SY ·2026-11-12 ·Chayan Kumar Paul, Pushpak Jagtap
Abstract

Classical funnel control keeps the tracking error within a prescribed, time-varying envelope by increasing the feedback gain as the error approaches the boundary. For mechanical systems, this guarantee typically relies on velocity measurements. We show that it can be retained for fully actuated Euler--Lagrange systems using only position measurements. The proposed controller replaces the velocity error with a difference quotient of the position error over a fixed delay, while preserving the classical unbounded gain. It requires no plant model, reference derivatives, observer, or filter states. The central challenge is to reconcile the averaging inherent in delayed feedback with a gain that can grow without bound near the funnel boundary. We resolve this by establishing an a priori bound on the gain along closed-loop trajectories, independent of the delay. This bound yields a computable delay threshold that guarantees tracking within the prescribed funnel and boundedness of all closed-loop signals. The threshold depends only on bounds on the inertia, forces, and reference. Simulations demonstrate tracking accuracy comparable to full-state funnel control and tolerance of delays substantially longer than certified. With quantized position measurements, the controller also requires substantially less torque than an existing derivative-free funnel controller.

0.30

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Natural Swing-Up of an Underpowered Double Pendulum

cs.RO eess.SY ·2026-11-12 ·Arne Sachtler, Manuel Keppler, Florian Loeffl, Alin Albu-Schäffer
Abstract

Robots with weak motors must ride their natural dynamics rather than fight them. We swing up a direct-drive planar two-link robot, whose motors deliver only about 6\,\% of its shoulder gravity torque, along its nonlinear normal modes, two-dimensional invariant manifolds consisting of periodic orbits. On a non-strict mode, injecting energy necessarily moves the state off the manifold, so pumping and stabilization compete for the same bounded torque. We split the input torque into a power-neutral steering component and a scalar pumping input, the only component that changes the energy. The allocation then becomes a linear program in two variables: maximize pumping subject to the torque limits and one control-Lyapunov constraint. The constraint uses the model-based rate of the error, so no stabilizing feedback gain is needed. Experiments in hardware show swing-ups along both modes and compare the allocation with summing-and-clipping and with prioritized stabilization.

0.30

Sub-Synchronous Control Interaction Risk of Large Data Center Loads: A Frequency-Scan Assessment with Cross-Model Validation

eess.SY ·2026-11-12 ·Salish Maharjan, Junyuan Zheng, Lung-An Lee, Min Lwin, Zhaoyu Wang
Abstract · 13 pages, 16 figures. Submitted for IEEE publications

Data centers are now one of the fastest-growing loads on the bulk power system, and most of their demand reaches the grid through power converters inside uninterruptible power supplies (UPS). Whether these loads can take part in sub-synchronous control interaction (SSCI), as wind and HVDC converters do, has not been studied extensively. We examine this question with impedance-based frequency scans at the point of common coupling (PCC). Using a detailed proprietary model (INS-ISU), we scan the motor, variable-frequency-drive (VFD), lighting, and UPS-fed information-technology (IT) branches of a representative facility separately. Only the UPS in double-conversion mode shows negative resistance; it covers the whole sub-synchronous band and continues up to about 170 Hz. The other branches, and the UPS in bypass mode, stay passive. We then repeat the scans on three public models from PNNL, TAMU, and NLR. None of them shows negative resistance in bypass mode, while three of the four models do in double-conversion mode. Lowering the load from rated to light load makes the negative resistance deeper, as expected for a constant-power load, so a lightly loaded facility in double-conversion mode is the worst case. Raising the UPS DC-link capacitance pushes the negative resistance into a narrow band around the fundamental. These findings give a basis for screening data centers for SSCI during interconnection studies.

0.29

Energy system device sizing under closed-loop operation with imperfect forecasts

eess.SY ·2026-11-12 ·Cara Koepele, Kevin Wallington, Georgios Mavromatidis, John Lygeros
Abstract · 8 pages, 7 figures, 2 tables. Submitted to the 2027 European Control Conference (ECC)

The value of renewable energy devices depends on their operation, which must adapt to weather and demand using limited, imperfect forecasts that update over time. Conventional energy systems planning practices assume unlimited foresight in a single-level formulation, potentially leading to long-term investment in suboptimal device sizes. Accounting for realistic operation corresponds to a bi-level problem: the upper level selects device sizes, while the lower level contains closed-loop operation under evolving forecasts. We solve this problem using backpropagation MPC (BP-MPC), a gradient-based method, with a deterministic MPC as the lower-level controller. Using forecast errors generated by a parameterized martingale model of forecast evolution, we investigate how forecast accuracy affects the benefits of operation-aware energy systems planning and the resulting device sizes. In a case study of an energy system comprising photovoltaics, a battery, a heat pump, and thermal storage with uncertain weather and energy demands, accounting for closed-loop operation yields higher average cost savings as forecast error increases. The resulting designs achieve these savings by progressively shifting investment from battery storage to solar generation and thermal storage, which buffers forecast mismatches.

0.29

Can STATCOM and UPS-Based Voltage Support Mitigate Fault-Induced Reductions in AI Data Center Grid Power Draw?

eess.SY ·2026-11-12 ·Ziang Liu, Yimeng Liu, Francis Yunhe Hou
hot direction
Abstract · 10 pages, 5 figures

Artificial intelligence data centers (AIDCs) are rapidly increasing in number and capacity. These large electronic loads are interfaced through power electronic devices and can sharply reduce grid power intake during fault-induced voltage sags. Disturbances exceeding equipment ride-through capabilities may also trigger protective disconnection, posing risks to power system security. Static synchronous compensators (STATCOMs) and appropriately controlled AIDC uninterruptible power supply (UPS) rectifiers can provide reactive power support during voltage sags. This paper compares the individual and combined effectiveness of STATCOM and UPS-based voltage support in mitigating fault-induced reductions in grid power intake through electromagnetic transient simulations of a 1 GW AIDC connected to an IEEE nine-bus system. Simulation results show that STATCOM support better preserves short-term intake in milder tested faults, whereas UPS coordination maintains rectifier operation under deeper sags by reducing active intake to reserve reactive current capacity. Combined support improves auxiliary load retention and recovery in selected cases. However, severe tested sags still cause substantial grid-demand reductions even with combined support.

0.29

Methanol substitution suppresses deflagration-excited knock and increases the efficiency of a hydrogen-fuelled CFR engine

eess.SY physics.chem-phmath-ph ·2026-11-12 ·Riming Xu, Mebin Panithasan, Xinyang Wang, Giovanni Vorraro, James W. G. Turner
unusual
Abstract · 20 pages 8 figures

Knock restricts the performance of hydrogen spark-ignition engines and is usually attributed to end-gas autoignition. To the authors' knowledge, this is the first study in which methanol is used to replace part of the hydrogen in a hydrogen engine at constant fuel energy addition, and it shows that near the knock boundary the limiting oscillation is excited by the deflagration itself, which methanol removes without derating the performance. Port-injected methanol replaced 20--50% of the hydrogen energy in a variable-compression Cooperative Fuel Research engine at 600 rpm and compression ratios of 8--12. With pure hydrogen, oscillation in the 4--15 kHz range began before 10% of the charge had burned in 97--100% of cycles, and its maximum amplitude (MAPO) followed the maximum pressure-rise rate across 2499 cycles (Spearman $ρ=0.94$). Methanol slowed the deflagration: it replaced high-flame-speed hydrogen, cooled the intake by 24--25 K and, at unchanged intake pressure, enleaned the mixture by 10--13%. At 50% methanol, the 10--90% combustion duration lengthened 2.7--3.0-fold, oscillation onset moved 4.5--8.3$^\circ$CA after CA10 and mean MAPO fell by 89--93% although the spark timing was advanced by 13--19$^\circ$CA, and IMEP and indicated thermal efficiency rose by 2.4--7.8%. Methanol was thus worth more than this advance, and at matched CA50 MAPO was still about 90% lower. The measured combustion duration of all 25 data sets scaled with the computed laminar flame speed as $S_L^{-0.58}$ ($R^2=0.99$); fuel replacement accounted for about three quarters of the reduction in $S_L$, and the end-gas autoignition integral stayed below 0.07, against 1 at autoignition. The chamber kept its cylindrical acoustic modes, whose frequencies fell by 8--9%. The trade-off is formaldehyde emissions, which rose five- to sixfold while NO$_x$ fell by 49--85%.

0.28

Robust Control Design for LTI Systems with Sampling-Time Jitter

eess.SY ·2026-11-12 ·Dieter Schwarzmann, Jan Lunze
Abstract · Submitted to ECC2027

Sampling-time jitter makes a sampled-data control loop time-varying, so standard LTI robust-control synthesis does not apply directly. This paper reformulates dynamic output feedback design under bounded, unmeasured sample-to-sample jitter as a robust-control problem. The exact zero-order-hold model is decomposed into a nominal time-invariant plant and a memoryless, time-varying uncertainty block with a norm bound representing the sampling-time jitter. As the block is memoryless, the operator small-gain condition for the time varying loop reduces to a standard robustness test with a matrix norm bound. It is shown that the same test also guarantees uniform exponential stability for every admissible jitter sequence. Embedding the decomposition into a generalized plant with performance channels serves two synthesis objectives with standard robust-control tools: Robust stability with optimized nominal performance through structured H-inf synthesis, and robust performance through mu synthesis with constant scalings. A numerical example shows that jitter can destabilize a control loop with a nominal H-inf controller, whereas both robust designs remain stable and the robust-performance design is less sensitive to jitter at the cost of nominal performance.

0.28

GRID-MRI: Resilience Assessment of Power Systems under Coordinated Cyber-Physical Attacks

eess.SY cs.CR ·2026-11-12 ·Isaac Ortega Romero, Ioannis Zografopoulos
Abstract · IEEE PESGM 2027, 5 pages

The increasing penetration of inverter-based resources and growing cyber-physical interdependencies expose electrical power systems to disturbances that challenge conventional resilience assessments. Existing approaches often evaluate resilience dimensions independently, overlooking the non-additive effects of coordinated disruptions and the influence of exogenous stressors. To address this gap, this paper proposes a Grid Multidimensional Resilience Index (GRID-MRI) that integrates endogenous disruption severity, coordination effects, and climatic and economic-regulatory conditions. The framework quantifies physical, cyber, and operational degradation, identifies interaction effects through counterfactual (i.e., what-if), simulations of individual and coordinated attacks, and incorporates exogenous stressors as scenario-dependent scaling factors. Its application to a modified IEEE 39-bus system under three escalating cyber-physical attack scenarios, informed by the December 2025 Polish cyberattack incident, reveals that coordinated attacks induce system collapse despite stable individual and additive responses. The corresponding resilience losses are 3.72 and 4.09 times their additive estimates, while GRID-MRI increases from 0.062 to 1.188 and reaches 6.081 under additional exogenous stress. These findings demonstrate the limitations of additive assessments and establish a quantitative basis for distinguishing the dominant mechanisms of multidimensional resilience degradation.

0.28

Learning monotone game-theoretic linear MPC

eess.SY math.OC ·2026-11-12 ·Alberto Bemporad, Tatiana Tatarenko
Abstract · 15 pages, 1 figure

We propose a method to learn a game-theoretic model predictive control (GT-MPC) law by imitation from input and output data of a running multi-agent system. By interpreting the recorded inputs as the first moves of the equilibria of a game played by the agents, we learn the GT-MPC weights under hard input constraints and soft output constraints, without requiring the agents to reveal their objectives. We also impose that the resulting generalized Nash equilibrium (GNE) problem is strongly monotone, which ensures the existence and uniqueness of the equilibrium and, hence, that the learned GT-MPC law is well defined and can be evaluated efficiently online by variational GNE-seeking algorithms for linear-quadratic games. Moreover, strong monotonicity implies that the equilibrium is almost everywhere differentiable with respect to the references and the weights, which enables automatic differentiation for gradient-based optimization. In addition, we promote closed-loop stability of the unconstrained equilibrium feedback by incorporating a penalty that involves a jointly learned quadratic Lyapunov function. Learning a GT-MPC formulation enables us to explain the agents' objectives, reproduce their behavior in simulation in new scenarios, optimize their set-points, design mechanisms, and enforce additional constraints. A numerical example illustrates the approach.

0.26

Structure-Preserving Learning for Nonlinear Nonholonomic Dynamics

eess.SY ·2026-11-12 ·Thomas Beckers, Anthony Bloch, Leonardo Colombo
Abstract

Learning the dynamics of mechanical systems subject to nonlinear nonholonomic constraints is challenging, as data-driven models may violate the underlying physical constraints, leading to inconsistent predictions. To address this problem, we develop a constraint-preserving learning framework based on the Lagrange-d'Alembert-Chetaev equations and tangency to the constraint submanifold, which together define an affine space of admissible accelerations. Using the kinetic-energy metric and the Moore-Penrose pseudoinverse, we construct a metric projector and the corresponding Chetaev correction. Embedding this geometric structure directly into a Gaussian process prior ensures that both prior and posterior dynamics satisfy the acceleration constraints exactly. We characterize the resulting reproducing kernel Hilbert space (RKHS), derive an adapted-coordinate representation, and establish nonexpansiveness and consistency transfer. Numerical experiments on a three-dimensional directional flocking system with up to 50 agents demonstrate exact constraint preservation and robustness to constraint-incompatible observations.

0.26

DiSKO: Distribution Steering for Nonlinear Systems using the Koopman Operator

eess.SY ·2026-11-12 ·Dimitrios Moustroufis, Panagiotis Tsiotras
Abstract

This paper studies the problem of data-driven covariance steering for stochastic, nonlinear dynamical systems. We utilize Koopman operator theory to learn, directly from data, an approximate linear representation of the nonlinear dynamics in a lifted space of observable functions of the state. By exploiting this linear model, we design controllers for the mean and covariance of the underlying nonlinear system by utilizing linear distribution steering algorithms. To account for approximation errors in the learned dynamics and the ambiguity in the disturbance distribution induced in the lifted space, we formulate the problem as a distributionally robust covariance steering problem. Furthermore, we leverage a deep neural network (DNN) to simultaneously learn the Koopman observables and the linear model parameters, thus eliminating the need for manual observables basis selection while also reducing the dimensionality of the lifted representation. Additionally, we can promote desirable model properties, such as stability, during DNN training. We demonstrate the effectiveness of the proposed framework via numerical simulations.

0.25

Mode-in-Variance Participation Factors under Stochastic Excitation

eess.SY ·2026-11-12 ·Bruno Pinheiro, Liya Huang, Georgios Tzounas
Abstract

This paper investigates how the dynamic modes of a power system contribute to the stationary variance of its variables under continuous stochastic excitation. Using a modal decomposition of the covariance matrix, the variance of each state or algebraic variable can be resolved into components associated with individual modal responses and their interactions. These components are shown to correspond to within-mode variance and cross-modal covariance, respectively, and the corresponding normalized contributions are termed mode-in-variance participation factors (PFs). The proposed PFs can be used to identify modes governing the variability of important system quantities such as frequency and voltage, quantify the effect of modal interactions, and reveal control dynamics that can be targeted to reduce their stochastic variability. These capabilities are demonstrated through case studies based on the Kundur two-area and IEEE 39-bus systems.

0.24

Incremental Model Predictive Control for Reference Tracking of Nonlinear Anesthesia Dynamics

eess.SY ·2026-11-12 ·Maxim Raymond, Kaouther Moussa, Teodoro Alamo, Mirko Fiacchini, Jimmy Lauber
benchmark
Abstract

Anesthesia dynamics are commonly described by Wiener models, consisting of linear dynamics followed by a static nonlinearity. This nonlinear output complicates the derivation of theoretical guarantees on closed-loop stability and convergence. Model Predictive Control (MPC) is particularly suitable for anesthesia control, as it explicitly accounts for constraints in the control design. In this paper, we propose an incremental MPC formulation for tracking a desired reference. The proposed approach exploits the structure of the nonlinear output equation to reformulate the control problem within a linear framework. An incremental model is then employed to avoid the explicit computation of steady states and inputs, which may be inaccurate in the presence of model uncertainties. The proposed controller is evaluated through simulations involving 1000 virtual patients and compared with a benchmark MPC formulation. Results show improved steady-state reference tracking while maintaining satisfactory disturbance rejection.

0.23

CT-RespGeomLib: Deterministic reconstruction of CT airway masks into editable,port-matched lumen geometry

eess.SY ·2026-11-12 ·Nichula Wasalathilaka, Kevin Dawson, Chinthaka Jacob, Mervyn Parakrama Ekanayake, Roshan Godaliyadda
Abstract

Patient-specific airway modelling requires geometrically consistent lumen surfaces with identifiable boundaries and support for controlled anatomical modifications. We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence. The parametric representation further enables localised modelling of airway stenosis and dilation without re-segmentation. Evaluated on 42 reference airway masks from ATM22 (15 cases) and AeroPath (27 cases), the framework produced 37 topologically accepted reconstructions, with a median port-to-loop distance of 0.123 mm across 2174 matched ports. Reconstructed and reference equivalent radii showed strong agreement ($R^2 = 0.976$), with a mean bias of -0.414 mm arising primarily from the circular, inscribed-radius representation. Controlled pathology modelling generated 40 variants across five patient-specific geometries, including 25-75% stenosis and 50% dilation at tracheal and main-bronchus locations. Prescribed radius changes were reproduced with a mean absolute ratio error of 0.0056, while the median 95th-percentile deviation outside the modified region was 0.111 mm. Downstream applicability was demonstrated through volume meshing and an OpenFOAM simulation with individually prescribed model-based resistance conditions at 62 outlets. Although additional surface preparation may be required for numerical meshing, CT-RespGeomLib provides a reproducible framework for CT-derived airway reconstruction, quantitative boundary validation and controlled geometric pathology modelling.

0.23

Survivability Guarantees for Delayed Serial Supply Chains under Demand Shocks

eess.SY ·2026-11-12 ·Lorenzo Giordano, Francesco Lo Iudice, Josep M. Olm, Marco Coraggio
theory
Abstract

When demand exceeds the maximum production capacity of a supply chain, it can be satisfied only for a finite time, determined by the inventory stored along the chain. Existing control methods ensure indefinite constraint satisfaction under bounded demand, but provide no guarantees on how long a supply chain can withstand a shock in which demand goes beyond production capacity. We address this gap for a serial supply chain with transportation delays and flow constraints. Under a specified flow policy, we derive necessary and sufficient conditions on the inventory distribution that guarantee a prescribed lower bound on the exit time from the set where demand is served. We use these conditions to compute inventory targets that minimize holding costs via a quadratic program. Then, we propose a two-mode controller that builds reserves under ordinary demand and depletes them during the shock. Simulations illustrate this approach.

0.23

FanCyqlone: A Parallelized Solver for Multi-Horizon Optimal Control

eess.SY math.OC ·2026-11-12 ·Matisse Teuwen, Pieter Pas, Mathijs Schuurmans, Panagiotis Patrinos
Abstract

Multi-horizon optimal control aims to select optimal control sequences simultaneously for several possible future scenarios, ensuring consistency at the first stage. While this enables advanced model predictive control schemes that explicitly handle prediction uncertainty, solving these problems tends to be costly. We introduce FanCyqlone, a linear solver that exploits parallelism across both time steps and scenario branches. The method builds on Cyqlone to compute the contribution of each branch and combines these results through a shared root problem. We integrate FanCyqlone into QPALM to develop FanCyQPALM, a solver for multi-horizon optimal control problems with general linear stage-wise constraints. We compare its performance with state-of-the-art solvers on spring-mass and quadruped control benchmarks.

0.23

Input-output characterization of robotic grasping: Connecting design parameters to grasp behavior through the admittance

cs.RO eess.SY ·2026-11-12 ·Julien Vanderheyden, Guillaume Drion, Pierre Sacré, Fulvio Forni
Abstract

Low-impedance grippers make the dynamics of a grasp matter. Current grasp metrics, however, are static: they describe how a held object resists constant loads, not how it responds to time-varying ones. To quantify this, we rely on small-signal analysis to characterize a grasp by its admittance, the transfer matrix relating load perturbations to object displacements around an equilibrium. This transfer matrix recovers the stiffness and stability of the grasp at zero frequency and captures its natural frequencies and peak gain under time-varying loads. We apply this characterization to a planar two-finger gripper under proportional-derivative control. We show that two grasps of the same object in the same position and with the same contact forces can differ in stiffness by two orders of magnitude. Likewise, two grasps that share the same stiffness can exhibit very different resonances. Nonlinear simulations confirm the effectiveness of our small-signal analysis in capturing the dynamic behavior of grasping.

0.23

An Integrated Architecture for Data-Efficient Real-Time Neural Imitation of Nonlinear Time-Optimal Model Predictive Control

eess.SY cs.LGcs.RO ·2026-11-12 ·Maarten De Baecke, Flavia Sofia Acerbo, Andrea Giusti, Wilm Decré
Abstract · Submitted to European Control Conference 2027 (Brussels)

Nonlinear time-optimal model predictive control (TOMPC) enables highly performant control of constrained systems, but its computational cost prohibits real-time use on fast dynamical systems. Neural network imitation of the TOMPC control law can reduce online computational costs, yet existing work mostly targets quadratic cost formulations in simulation and addresses the challenges of neural controllers in isolation. This work imitates a long-horizon nonconvex TOMPC with hard terminal constraints, whose high computational cost limits training-data generation. We present (i) \emph{self-informed sampling (SIFS)}, a data-efficient expert-sampling strategy that uses a learned time-to-go to query the expert only where the policy deviates from time-optimal behavior, (ii) a complete training and control architecture that jointly addresses dataset correlation, suboptimal expert labels, covariate shift, constraint satisfaction and model mismatch, and (iii) real-world validation on a Furuta pendulum. SIFS matches standard dataset aggregation performance in roughly one-third of the training time and with less than half the training data. The resulting controller matches the region of attraction of the expert TOMPC while raising the control frequency from 1.4~Hz to 1~kHz. On hardware, the controller swings up and stabilizes the pendulum along trajectories closely matching the expert TOMPC solution.

0.23

Control-Gibbs Distribution: Sampling for Optimal Control and Diverse Actions

eess.SY ·2026-11-12 ·Shengling Shi
Abstract

While conventional optimal control selects an optimal input sequence, probabilistic control assigns probability mass over all possible inputs and exploits a distribution of control sequences. Control distributions help enable exploration, capture diverse solutions, and solve deterministic optimal control problems. This work reviews an important probabilistic model for control distributions, the control-Gibbs distribution, i.e., the Gibbs distribution with an optimal control objective as the energy function. We point out its fundamental role in various probabilistic control frameworks, e.g., maximum entropy control, control-as-inference framework, model predictive path integral control, and energy-based models for control. This provides a model-central perspective to unify these probabilistic control frameworks. We also review the associated extensions of dynamic programming for computing closed-loop control distributions. To sample the control-Gibbs distribution, we consider projected Langevin sampling and develop non-asymptotic guarantees. The guarantees show the dual benefits of sampling the control-Gibbs distribution: obtaining diverse control solutions and solving the deterministic optimal control problem. We provide a numerical example where diverse arm trajectories are sampled from a control-Gibbs distribution.

0.22

RAZeR: Representation Aware Zonotope Reduction

eess.SY ·2026-11-12 ·Vladimir Krsmanovic, Tobias Ladner, Bernd Finkbeiner
position
Abstract

Reachability analysis is a popular technique for verifying the safety of a dynamical system under uncertainty, where the uncertainty is often represented by zonotopes. As the size of the zonotope representation typically grows as the reachability analysis progresses, it must be repeatedly reduced at the cost of additional conservatism. While various methods exist to reduce the size of the representation, combined advantages are not fully leveraged as only a single reduction method is typically used throughout the analysis. In this work, we show how dynamically choosing which method to use can yield significantly tighter results, thereby easing verification. This is realized by introducing a heuristic, derived from model predictive control, that accounts for upcoming propagation of the current zonotope. We argue that order reduction is not merely a post-processing step after propagation but also a pre-processing step that shapes how the zonotope evolves under the system dynamics. We evaluate our approach, RAZeR, on nonlinear benchmarks taken from the ARCH-COMP, where we demonstrate that RAZeR produces tighter zonotopes at a negligible performance overhead.

0.19

On Energy-Based Modelling for Fluidic Excitable Neurons

eess.SY ·2026-11-12 ·Robin Wroblowski, Brent Michiels, Benjamin Gorissen, Rodolphe Sepulchre
Abstract · 6 pages, 5 figures, submitted to European Control Conference 2027

Motivated by the potential of pneumatic excitable devices in soft robotics, this paper develops an energy-based, domain-agnostic equivalent of the Hodgkin-Huxley modelling framework using bond graph theory. The proposed model is used to guide the design of a pneumatic excitable neuron. The potential of this approach is illustrated through the design of a pneumatic half-center oscillator, an essential building block for rhythmic neuromorphic behaviours.

0.19

A Coupled Control Barrier Function Approach to Deadlock-Free Multi-Robot Conflict Resolution

cs.RO eess.SY ·2026-11-12 ·Gary Rostomyan, Ketan Savla, Petros A. Ioannou
Abstract

Many robotic applications involve scenarios where multiple robots interact and the decisions of one robot influence the behavior of others. This paper presents a quadratic programming (QP)-based feedback controller for multi-robot conflict resolution with input constraints. Safety is enforced using coupled Control Barrier Function (CBF), while a yielding matrix encodes how robots influence each other. Unlike existing methods with fixed or hard priorities, the proposed framework enables yielding preferences while guaranteeing deadlock-free operation by design. Sufficient conditions are established for the controller to be locally Lipschitz. The optimal CBF sign- indefinite slack is shown to admit a finite uniform bound, which is compensated through an enlarged CBF safety margin to obtain a forward invariant set contained within the desired safe set. The analysis also identifies an irreducible slack component due to finite maximum deceleration that cannot be eliminated by increasing the slack penalty. Finally, sufficient conditions on the yielding matrix and nominal controller are derived to exclude deadlock states. Simulations demonstrate adaptive coordination across yielding preferences and robustness to robot failures.

0.18

FlatSeek: LLM-Driven Symbolic Discovery of Flat Outputs via Backward Data Generation

eess.SY ·2026-11-12 ·Zihao Fu, Xingchen Li, Keyou You
Abstract

Differential flatness enables efficient planning and control, but discovering explicit flat outputs for general nonlinear systems remains difficult due to the lack of general methods and supervised data. We propose FlatSeek, a framework combining backward data generation with task-specific large language model (LLM) training. By reversing the defining reconstruction of flatness, we generate system-flat-output pairs with known certificates, then fine-tune an LLM to propose symbolic flat-output candidates for unseen dynamics. On literature and synthetic benchmarks, FlatSeek outperforms both the traditional symbolic methods and the untuned reference models in flat-output discovery success, and uncovers alternative symbolic flat outputs not reported in the literature.

0.18

A New Analytical Method and Interpretation of Loss-of-Load Counts

eess.SY ·2026-11-12 ·Aidan Looney, Chanan Singh, Le Xie
Abstract · 5 pages, 3 figures, 1 table, submitted to IEEE PESGM

This paper establishes the relationship between loss-of-load expectation (LOLE) and loss-of-load frequency (LOLF). We show why LOLE generally does not measure distinct-event frequency, mean event duration, or shortage magnitude. We identify conditions under which peak-based LOLE admits a frequency interpretation as the expected count of deficient daily peaks per horizon and distinguish this quantity from LOLF. We also derive an analytical formulation for frequency-and-duration indices that combines a convolution-derived generation probability-and-frequency model with chronological load changes. Under stationary generation, it uses the prescribed load profile directly, without constructing a separate load model or discretizing load magnitudes. Studies using generation and load data from the 24-bus IEEE RTS reveal different event frequencies and mean event durations at identical peak-based LOLE, motivating their separate assessment. Numerical comparisons demonstrate the accuracy advantage of the proposed analytical calculation over the conventional analytical implementations, quantifying the LOLF errors incurred by load discretization.

0.18

DER Aggregators in Wholesale Electricity Markets: A Hybrid Mean-Field Framework with Endogenous Price Feedback

eess.SY ·2026-11-12 ·Jun He, Andrew L. Liu
theory
Abstract

The rapid growth of distributed energy resources (DERs), including rooftop solar and energy storage, is transforming the grid edge, where customer-side assets increasingly interact with the broader power grid. DER aggregators, entities that coordinate the actions of many small-scale DERs, play a key role in this transformation. This paper presents a hybrid Mean-Field Control (MFC) and Mean-Field Game (MFG) framework for integrating DER aggregators into wholesale electricity markets. Unlike traditional approaches that treat market prices as exogenous, our model captures the feedback between aggregators' collective actions and electricity prices. The MFC component optimizes DER operations within each aggregator, while the MFG models strategic interactions among multiple aggregators. To account for various uncertainties, we incorporate reinforcement learning, which allows aggregators to learn optimal bidding strategies in dynamic market conditions. We prove the existence and uniqueness of a mean-field equilibrium and validate the framework through a case study of the Oahu Island power system. Results show that our approach reduces price volatility and improves market efficiency, offering a scalable and decentralized solution for DER integration in wholesale markets.

0.17

Generalized Gated Recurrent Neural Networks for Nonlinear System Identification

eess.SY ·2026-11-12 ·Stefano De Carli, Davide Previtali, Mirko Mazzoleni, Fabio Previdi
benchmark
Abstract · 6 pages, 5 figures. Submitted to IFAC for possible publication

Long Short-Term Memory (LSTM) and Gated Recurrent Unit (GRU) networks are the two most widely adopted recurrent neural networks for black-box nonlinear system identification, yet they are invariably treated as mutually exclusive structural choices. To move toward a general framework that inherits the properties of both networks, we introduce the Generalized Gated Recurrent Neural Network (GGRNN), a unified architecture that embeds the exact GRU and LSTM network dynamics through homotopies between their respective gating mechanisms. Each homotopy continuously deforms one mechanism into the other, with a vector of homotopy parameters blending the contribution of the GRU and LSTM counterparts. Since benchmark comparisons report no consistent winner between the two architectures, the gating mechanism best suited to a given system is unlikely to coincide with either endpoint. We thus let each recurrent unit learn its own position along these homotopies, obtaining gating behaviors that neither endpoint can express. We pair the GGRNN with a two-stage training methodology: in Stage 1 we co-train all shared and network-specific parameters in parallel at the GRU and LSTM endpoint architectures, while in Stage 2 we freeze the network parameters and optimize only the homotopy parameters. Experiments on the Wiener-Hammerstein and Nano-Drone benchmarks show improved simulation accuracy over the co-trained GRU and LSTM networks on most output groups, and over the reference black-box baselines in nearly all comparisons.

0.17

Admissibility-Preserving Control for Block Strict-Feedback Systems Under Time-Varying Asymmetric Actuator and State Constraints

eess.SY math.DS ·2026-11-12 ·Saurabh Kumar, Lohitvel Gopikannan, Shashi Ranjan Kumar, Abhinav Sinha
theory
Abstract

This paper addresses the tracking control of block strict-feedback nonlinear systems subject to time-varying asymmetric actuator and full state constraints. To that end, we develop a time-varying Admissibility-Preserving Control (APC) framework, in which the Admissibility-Preserving Input Realization (APIR) generates the plant input through a dynamic realization. The APIR guarantees input admissibility under the moving actuator set whenever each actuator bound contracts slower than the decay rate of the realization, and a closed-form lower bound on its gain is derived. The state constraints are handled by a logarithmic barrier coordinate at every backstepping step, with widths measured from the virtual control to the moving envelope of the corresponding state. We prove that every state lies inside its envelope, with each virtual control only required to remain inside the envelope of the next state, while the tracking error converges to zero exponentially. Simulations demonstrate the efficacy of the proposed safety-critical control scheme.

0.14