CS Paper Radar

Weekly top 100 · eess.IV

2026-W45 Nov 02 – Nov 08, 2026

Ranked from 4,954 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Noise-Regularized Training for Learned Image Compression

eess.IV cs.CV ·2026-11-06 ·Renjie Zou, Zhiwei Huang, Dong Jiang
top venuecode/data
Abstract · 22 pages, 4 figures. Accepted as a Spotlight paper at NeurIPS 2026

Learned image compression (LIC) is trained almost exclusively on clean images: the only stochastic perturbation in the loop is an additive uniform proxy injected in the latent domain to keep the entropy model differentiable. Outside compression, by contrast, a long line of work---from Tikhonov regularization and contractive autoencoders through denoising score matching and modern diffusion models---has established that Gaussian noise at the input of a network with a clean target acts as a structured probe of the data manifold rather than as data augmentation. Building on this view, we introduce noise-regularized training for LIC: at every training step we add Gaussian noise to the encoder input while keeping the distortion target, the latent uniform proxy, the hyperprior, and the entropy coding pipeline unchanged. The recipe is architecture-agnostic and adds essentially no training or inference overhead. Across backbones and operating regimes it yields consistent BD-Rate gains: -2.60% on a reproduced ELIC and -0.85% / -1.05% / -2.38% on the Base/Medium/Large scales of a variable-rate DMCI codec, with DMCI-Large reaching -22.02% against VTM-22.0. A second-order expansion of the noisy RD loss accounts for these gains: because the noise enters upstream of the analysis transform, it converts the clean RD objective into a structured $O(σ^{2})$ regularizer comprising an information-weighted encoder-Jacobian penalty (rate side) and a Frobenius contractive penalty on the end-to-end reconstruction map (distortion side). A finite-difference Lipschitz analysis shows corresponding sensitivity reductions of ~12% for the encoder and ~8% for the end-to-end codec, while an exact-JVP test further shows preferential contraction of high-information directions. Code and trained models are available at https://github.com/Googolxx/NoiseRegu-LIC.

0.57
2

Dataset Collections: Challenges of Large-Scale Data Aggregation in 3D Medical Image Datasets

eess.IV cs.CV ·2026-11-06 ·Yannick Kirchhoff, Saikat Roy, Elisa Stegmeier, Hamideh Haghiri, Constantin Ulrich +28 more
top venuetheoryhot direction
Abstract · Accepted at NeurIPS 2026 E&D Track

The development of deep learning-based medical AI depends on high-quality annotated data. Yet, dataset creation remains constrained by the need for expert radiologist annotations, limiting curated datasets to relatively small cohorts. To overcome this limitation, recent efforts increasingly aggregate disparate public datasets into large-scale dataset collections. However, combining datasets at scale often obscures data provenance, introducing substantial risks of reuse propagation, unintended leakage, bias amplification and distorted data distributions. In this work, we study these problems on a massive collection of 565k 3D radiological images across 1034 public datasets and provide practical resources to address them. Firstly, we formalize dataset collections as a distinct paradigm in medical image analysis and characterize their structural challenges, including reuse propagation, duplication, and provenance fragmentation. Secondly, we perform a large-scale empirical study of duplication on this collection and demonstrate extensive exact and near-duplicate reuse across public datasets via perceptual hashing and manual tracing, identifying a lower bound of 118k duplicate pairs. We make the perceptual hashes publicly accessible for comparison through our website, providing researchers with a standardized reference for identifying potential overlaps and shared provenance. Thirdly, since hashing alone cannot detect all duplicates, we introduce MAP (Metadata for Aggregation and Provenance), a lightweight, portable metadata profile for documenting provenance, known overlaps, and deduplication decisions in dataset collections. Our contributions help dataset collections shift from coarse aggregations to reliable and provenance-aware data scaling mechanisms in medical image analysis. A web tool supporting our work is available at https://mic-dct.dkfz.de/.

0.46
3

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

eess.IV cs.CV ·2026-11-06 ·Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia +6 more
code/data
Abstract · 52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

0.45
4

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.43
5

HIVE-Diff: High Frame Rate HDR Video Reconstruction from a Single LDR Frame and Events

eess.IV cs.CV ·2026-11-02 ·Caixin Wang, Qingrui Wang, Jie Zhang, Ralph Etienne-Cummings
publishedcode/data
Abstract · Accepted to WACV 2027 (Applications Track). 8 pages main paper + 8 pages supplementary material (included as appendix), 12 figures, 5 tables…

High frame rate HDR video is important in applications such as autonomous driving and scientific imaging, where rapid motion and extreme illumination often occur simultaneously. Conventional frame cameras face a trade-off between temporal resolution and dynamic range, while event cameras provide complementary high-speed brightness-change measurements over a wide illumination range. These properties have motivated event-based HDR reconstruction, with existing methods broadly following event-only and hybrid event-frame paradigms. Event-only HDR reconstruction, however, suffers from brightness and color drift due to the lack of absolute intensity references. Hybrid event-frame methods alleviate this ambiguity using low-dynamic-range (LDR) frames as anchors, but most perform one-to-one HDR reconstruction at available LDR timestamps. In this work, we investigate single-reference HDR temporal expansion, reconstructing N HDR frames from one LDR reference and events instead of N aligned LDR observations. We develop HIVE-Diff, an event-conditioned video diffusion framework that decomposes the task into event-guided temporal generation and HDR content completion. Because paired real HDR-event data are scarce, we train on synthetic data and adapt the model to real event domains using LDR-event sequences as proxy supervision with teacher-student distillation. Experiments on synthetic and multiple real-world datasets demonstrate strong reconstruction quality and robust real-data adaptation.

0.43
6

Benchmarking Neural Image Compression with DCT-Based Spectral Diagnostics

eess.IV cs.CV ·2026-11-03 ·Nikolay I. Kalmykov, Razan Dibo, Yujun Du, Yipeng Liu, Ivan Oseledets +1 more
benchmarkcode/data
Abstract · 17 pages, including supplementary material. Code: https://github.com/nkalmykovsk/dct_benchmark_nic

Neural image compression (NIC) models are commonly evaluated with scalar rate-distortion metrics, which do not show how a codec treats individual spatial frequencies. We propose a benchmark that probes codecs with the DCT basis matrix and single-frequency test images. We measure relative off-target energy (leakage), the fraction of reconstruction energy outside the probed frequency, together with target-frequency gain. Exact decompositions and bounds relate these measurements to reconstruction error. At operating points nearest 1 bpp, the BMSHJ, MBT, and Cheng2020 models leave 80-97% of their reconstructed high-band energy outside the target bin and have target-frequency gains of 0.02-0.23, whereas TCM and FTIC attain off-target energy in the classical-codec range. Both probe types identify behavior absent from scalar metrics: released Cheng2020-Anchor models produce extreme pre-clamp outputs on isolated single-frequency inputs. Finally, decoder-only fine-tuning with natural-image and leakage losses reduces basis off-target energy by 90-99.8% across all eight evaluated architectures while keeping the bitstream fixed, at a Kodak PSNR cost of 0.09-0.59 dB.

0.42
7

Shared-Pattern Collaborative Network for Multi-Source Remote Sensing Data Classification

eess.IV cs.CV ·2026-11-02 ·Chenfang Yang, Chuanzheng Gong, Feng Gao, Junyu Dong, Qian Du
publishedcode/data
Abstract · Accepted for publication in IEEE JSTARS 2026

Multi-source remote sensing data classification has received growing attention recently. However, existing methods still struggle to jointly model long-range contextual dependencies and shared spatial patterns across heterogeneous modalities. To address this issue, we propose a Shared-Pattern Collaborative Network (SPCNet) for HSI and SAR/LiDAR joint classification. To enhance cross-modal collaborative learning, Shared-Pattern Collaborative Block (SPCB) is designed by introducing a shared large-kernel operator and a dynamic convolution branch, enabling the network to capture common spatial structures and content-adaptive local features. Furthermore, Region-Adaptive Modality Allocator (RAMA) is developed to assign spatially varying modality weights for reliable feature fusion. Experiments on Houston2013, Augsburg, and Houston2018 datasets demonstrate that SPCNet achieves superior classification performance over several state-of-the-art methods. The code will be made publicly available at https://github.com/oucailab/SPCNet

0.41
8

TOP: Transmission-Oriented Remote Sensing Pansharpening

eess.IV cs.CV ·2026-11-04 ·Zi-Han Cao, Jing-Ze Liang, Shao-Jie Wu, Jin-Cheng Di, Liang-Jian Deng +1 more
code/dataunusual
Abstract

Pansharpening has been extensively studied as a fundamental image fusion task in remote sensing. However, most existing methods focus on improving fusion quality under the implicit assumption that high-resolution observations have already been fully downlinked to the ground. As a result, existing models are highly vulnerable to perturbations introduced by lossy compression used for downlink transmission. To address this limitation, we present, to the best of our knowledge, the first transmission oriented pansharpening (TOP) framework, which unifies compact latent coding, onboard pansharpening, and efficient downlink transmission within a single satellite-toground pipeline. TOP encodes remote-sensing observations into a compact binary latent space, where a lightweight onboard fusion module can efficiently predict the fused binary latent code. Since only the compact fused code is downlinked, the transmission payload is substantially reduced. Overall, TOP enables low-payload downlink and lightweight onboard processing while maintaining high fusion quality under severe bandwidth constraints. Experiments across multispectral and hyperspectral settings show that TOP consistently achieves superior fusion quality at higher compression ratios than representative pansharpening methods paired with standard lossy codecs. For example, on GaoFen-2, TOP attains a fusion PSNR of 31.4 dB at a downlink compression ratio of 50x. This design also points toward transmissionoriented processing for other remote-sensing tasks. The code will be made available at https://github.com/JingZe-Liang/TOP.git.

0.38
9

Dual Flow: Joint Image-Measurement Flow for Inverse Problems

eess.IV cs.CV ·2026-11-04 ·Sevket Ege Yesilyurt, Figen S. Oktem
code/data
Abstract · 17 pages, 8 figures. Our code is available at https://github.com/METU-SPACE-Lab/Dual-Flow

Existing generative model-based approaches to linear inverse problems typically use the acquired noisy measurement to condition or guide sampling in the image domain. In this work, we introduce Dual Flow, a novel joint flow model for solving linear inverse problems by jointly estimating the clean image and its corresponding noise-free measurement from the observation. Specifically, Dual Flow formulates image reconstruction and measurement denoising as a coupled estimation problem, using coupled flows in the image and measurement domains. The acquired noisy measurement $\mathbf{y}_0$ is used only to initialize the measurement state; thereafter, the image and measurement states are jointly updated based on their current values. By construction, the final image and measurement estimates are guaranteed to satisfy the underlying forward model. We derive the sampling updates for the joint flow and show that they are governed by the conditional mean of the clean image given the current joint state. We further derive a closed-form expression for a sufficient statistic of the joint state and show that the required conditional mean can be obtained by solving an image-domain Gaussian denoising problem involving operator-dependent, correlated noise. We train a velocity-prediction network using this formulation to estimate the conditional mean from the derived sufficient statistic. Dual Flow requires no hyperparameter tuning beyond selecting the number of inference steps and achieves substantially shorter reconstruction times than competing methods. Extensive experiments across various linear inverse problems and image datasets demonstrate state-of-the-art performance in both distortion metrics and perceptual quality. Additional analyses assess robustness to model mismatch, as well as the ability to generate diverse plausible reconstructions and characterize reconstruction uncertainty.

0.36
10

Evaluating the Impact of Nonlinear Registration on Longitudinal PET Analysis in a Rodent Stroke Model

eess.IV cs.CV ·2026-11-02 ·Haytham Ziani, El Mostafa Kalmoun, Zohaib Atif, Hyuk-Sang Kwon
top venue
Abstract · Accepted for presentation at the 2nd International Conference on Artificial Intelligence, Security and Networking (CAISN 2026)

Longitudinal rodent positron emission tomography (PET) studies of stroke and neuromodulation rely on accurate registration to a common atlas space to detect group-level effects. Prior work applying ultra-high frequency low-intensity magnetic stimulation (UHF-LiMS) to a rat model of chronic capsule infarct used affine normalization to a Sprague Dawley MRI template without evaluating that choice. We compare a two-stage (affine and nonlinear) pipeline against an affine- only one for rat PET-to-atlas alignment on the same dataset. Across 32 longitudinal [18F]-FDG PET scans (8 rats, 4 timepoints), the nonlinear stage gave a higher Dice similarity coefficient on every scan, and the gain was significant at the rat level. Jacobian determinants showed no folding on the sampling grid. Group-level linear mixed-effects maps of change from baseline (AFNI 3dLME), computed identically under both pipelines, differ in the size, number and location of their suprathreshold clusters. In this dataset, the registration pipeline is therefore a variable that can change the interpretation of downstream group-level analyses.

0.36
11

AdaptivePnP: Fast Auto-Tuned Plug-and-Play for Deconvolution

eess.IV cs.CV ·2026-11-06 ·Haley Duba-Sullivan, Emma J. Reid, Charles A. Bouman, Gregery T. Buzzard
code/data
Abstract · Submitted to IEEE Transactions on Computational Imaging

Plug-and-play (PnP) methods reconstruct images by alternating a data-fitting step with an image denoiser. Their performance depends on two parameters: the step size $γ$ and the measurement noise level $σ$. In practice, $γ$ is often tuned by grid search over validation images and must be retuned whenever the problem setting changes, and $σ$ is assumed known or estimated separately. We propose AdaptivePnP, a PnP framework that jointly estimates $σ$ and $γ$ at every iteration from the data-fitting residual. To do so, we apply the PnP virtual model to the data-fitting proximal map and show that the residual is zero-mean Gaussian with covariance parameterized by $γ$ and $σ$. However, when one parameter is much larger than the other, the residual carries little information about the smaller one and using the maximum likelihood (ML) estimator can degrade the PnP iterations. We therefore introduce the identifiable maximum likelihood (IML) estimator, which restricts the ML estimator to an identifiable window in which the normalized Cramér--Rao bound of every parameter is bounded by a user-specified tolerance. For the virtual model, this window is an interval of ratios $ρ= γ/σ$, so computing the IML estimate reduces to a one-dimensional search over $ρ$. We apply AdaptivePnP to two standard PnP methods, yielding algorithms that require neither a tuned $γ$ nor a known $σ$. On image deblurring and super-resolution, AdaptivePnP matches or outperforms PnP baselines tuned with the true $σ$. Code is available at https://github.com/hdubasullivan/AdaptivePnP.

0.36
12

A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema

eess.IV cs.CV ·2026-11-02 ·Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani, Alireza Dehghani, Michael J. Allingham +1 more
code/data
Abstract · 18 pages, 8 figures, 6 tables, Submitted to IEEE Journal of Biomedical and Health Informatics

Diabetic macular edema (DME) is a leading cause of severe vision loss among working-age adults. Although intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections currently serve as the first-line therapy for DME, a notable subset of patients fails to respond despite the substantial cost and clinical burden, suggesting they may benefit more from alternative interventions. Automated, noninvasive pre-treatment response assessment could therefore spare non-responders from the current trial-and-error treatment paradigm. In this study, we propose a novel conditional adversarial diffusion framework that synthesizes post-treatment optical coherence tomography (OCT) images from baseline scans, enabling the derivation of each patient's initial response to anti-VEGF therapy. The model was developed with subject-level 5-fold cross-validation on a US cohort (n = 127) and externally validated on an independent Iranian cohort (n = 44). Benchmarked against fourteen baseline and state-of-the-art translation models, the proposed model achieved the best treatment-response prediction performance among the methods evaluated for that task on both cohorts, with balanced accuracies of 85.7% and 93.0% on the US cohort and 85.2% and 95.3% on the external Iranian cohort at the 10% and 20% central subfield thickness reduction thresholds, respectively. Ultimately, this framework offers a decision-support tool to help ophthalmologists anticipate initial anti-VEGF outcomes in DME prior to treatment initiation, toward personalized therapy selection. The source code will be made publicly available upon acceptance.

0.36
13

Progressive Multi-Scale Super-Resolution via Cascaded Bicubic Anchors and Inter-Scale Mutual Refinement

cs.CV cs.LGeess.IV ·2026-11-02 ·Chun-An Lin, Yu-Chia Chang, Chi-Mao Fan, Yen-Chieh Ouyang, Tsung-Jung Liu
code/data
Abstract · 14 pages, 7 figures, 7 tables. Submitted to an IEEE journal. Code and pretrained models will be released at https://github.com/julian135707/…

Super-resolution networks are trained for one magnification factor, so several output resolutions require several models. We propose PMS-SR, a progressive single-input multiple-output network that produces x2, x4, and x8 results in one forward pass, with a Transformer backbone on the low-resolution grid. In Stage 1, each scale is predicted as a residual over the detached bicubic upsampling of the previous scale's prediction. With Dirac and zero initialization, training starts exactly from the bicubic cascade, and each head adds only the band the previous scale lacks. In Stage 2, inter-scale mutual refinement couples the scales in both directions through space-to-depth feedback, deformable alignment, and per-pixel fusion, so x8 features refine the x2 output. Trained on DF2K, the 7.95M-parameter model achieves a higher PSNR than every compared multi-scale method at x4 and x8 on all five standard benchmarks. At x8, it outperforms the x8-specific DRN-L on all of them, leads all compared methods on Urban100, and is within 0.13 dB of the best result elsewhere. Against three single-scale SwinIR-M models, PMS-SR uses 22% of the parameters, runs 2.9x faster on BSD100 inputs, and its outputs agree 6.7-12.4 dB more closely. Code and pretrained models will be released at https://github.com/julian135707/PMS-SR upon acceptance.

0.33
14

Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRI

eess.IV cs.AI ·2026-11-02 ·Necati Sefercioglu, Mehmet Ozan Unal, Metin Ertas, Altan Cakir, Isa Yildirim
Abstract · 5 pages, 3 figures, 4 tables. Submitted to ISBI 2027

A brain MRI scan can carry an unknown mix of artifacts, so restoration has to be blind, yet most deep-learning methods are built to correct one known artifact. We present Dx-Rx, an agent in which a multimodal large language model (MLLM) measures suspected artifacts before it repairs them. To our knowledge, it is the first agent to restore whole 3-D MRI volumes, whereas earlier MRI agents restore 2-D slices. In a loop, it looks at slices of the 3-D volume, calls five diagnostic tools (noise, spike, ghosting, bias field, motion) and four restoration tools in any order it chooses, checks each repair, can return to any earlier version to change the order, and ends with a radiology-style report of its diagnostic reasons, the repairs it applied and their results. We simulated up to five artifacts on 148 whole 3-D T1-weighted volumes, at levels calibrated to radiologists' grades of real scans. An MLLM that only looked at the image, as earlier MRI agents do, removed at most 19.7 % of the artifact error. With the best of five MLLMs, Dx-Rx removed a mean 64.5 %, nearly matching the 64.6 % of the same tools given the ground-truth artifacts, which are never known for a clinical scan. With all five models, it made no volume worse and was on par with or better than an expert rule-based pipeline built from the same tools (62.3 %). Code and demo are public at https://itu-biai.github.io/measure-before-you-repair.

0.33
15

Subliminal Learning in Vision-Language Models

cs.CV cs.AIcs.CLcs.LG+1 ·2026-11-04 ·Arman Hatami, Romina Aalishah, Ilya E. Monosov
published
Abstract · Accepted to WACV 2027

Subliminal learning is a phenomenon in large language models (LLMs) where a teacher passes a hidden preference to a student through training data unrelated to that preference. We study whether subliminal learning also occurs in vision-language models (VLMs). We finetune a teacher VLM to prefer a specific animal or facial attribute and use a control teacher from the same base model. Both teachers generate numbers for an unrelated visual task involving geometric shapes. Two students initialized from the same base VLM are finetuned on the same images, using numbers generated by either the biased or control teacher. Across VLMs ranging from 2B to 7B parameters, we find that both animal and facial preferences can transfer through this unrelated task. Students trained on biased-teacher outputs select the target more often than control students, with a difference of up to $\sim$10 percentage points in the animal preference task. Transfer can become stronger with more training data and varies with the target preference, model, and how the numbers are generated. Beyond preferences, we show that the biased student's explanations use more of the same words and phrases as the biased teacher's explanations than those of the control student, even when all three models select the same image. These results matter for training VLMs and show that training on unrelated data may change both a VLM's image preferences and how it explains its choices, and that transfer can become stronger with more training samples.

0.32
16

Deep Plug-and-Play Proximal Distance Algorithm for Robust Principal Component Analysis

eess.IV eess.SP ·2026-11-03 ·Guanhua Liu, Mingjie Shao, Wenxuan Sun, Zhi Liu, Yanlong Zhao
published
Abstract

Robust Principal Component Analysis (RPCA) is essential in signal processing, with applications in hyperspectral imaging, face recognition, and video background modeling. Traditional RPCA methods often suffer from insufficient utilization of data priors and struggle to capture complex image structures. Conversely, advanced deep denoisers like DnCNN, FFDNet, and DRUNet excel at leveraging image data priors but lack physical model constraints and demonstrate poor robustness against structured noise in RPCA tasks. This paper proposes a novel Plug-and-Play (PnP) method for multi-channel RPCA, integrating both the physical generative model and cutting-edge deep priors. Extensive experiments on RGB and hyperspectral datasets show that PnP-PDA achieves better quantitative performance than conventional RPCA methods and state-of-the-art methods, including deep denoisers and tensor RPCA approaches, while preserving visual details.

0.31
17

Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment

eess.IV cs.CV ·2026-11-05 ·Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal, Metin Ertas, Isa Yildirim
hot direction
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

No-reference image quality assessment (IQA) of low-dose CT predicts the score that radiologists would assign to a slice without a full-dose reference, as needed to compare dose protocols and denoisers. Trained CT IQA networks agree well with radiologists but output only a score, whereas multimodal large language models (MLLMs) can explain a score but perform poorly on CT when only prompted. We propose a measurement-aware MLLM, built on Qwen3.8-27B, that rates a slice from its image together with six image-domain measurements of noise, sharpness, high-frequency content and streaks, given to the language model as percentiles in text. On the LDCT-IQA 2023 test set, it reaches an Overall score of 2.735, on par with the retrained challenge winner (2.735) and MedSigLIP-FiLM (2.713), and substantially above its base MLLM used as a zero-shot agent. Shuffling the measurements at test time reduces the score by 0.048, mostly through noise, but the same measurements also lead the model to assign higher scores to over-smoothed denoised images.

0.31
18

Air-Scan-Based Point-Spread-Function Estimation for Megavoltage CT with Flat-Panel Detectors

eess.IV ·2026-11-02 ·Seemeen Karimi, Joseph Bendahan, K. Aditya Mohan
publishedunusual
Abstract · This has been presented at a conference, proceedings are pending

Accurate spatial-resolution characterization of flat-panel detectors at megavoltage energies is difficult due to long-tailed cross-talk. Conventional measurements at high energy using line-pair gauges or knife-edge phantoms require expensive, carefully fabricated objects and precise alignment, and despite these, scatter from the phantom, detector, and imaging room can further confound the measurement. We present a method for estimating the detector point spread function (PSF) from the mean noise power spectrum (NPS) calculated from repeated radiographs in air. The approach is mathematically equivalent to an autocovariance-based method but is more practical for long-tailed PSFs. We validate the method using simulated air data and Monte Carlo N-particle (MCNP6) calculations of energy deposition in a flat-panel detector. We show that deconvolving the experimental PSF increases the accuracy of transmission radiographs of step wedges. The method requires no phantom or alignments and is straightforward to reproduce.

0.31
19

Covariate-Conditioned One-Step Diffusion for Multi-Horizon 3D Brain MRI Prediction in Aging and Neurodegeneration

eess.IV cs.AIcs.CVcs.LG ·2026-11-05 ·Natenaile Asmamaw Shiferaw, Ali Farki, Deepika Koundal, Jussi Tohka
code/data
Abstract · 5 pages, 2 figures, 4 tables. Submitted to IEEE ISBI 2027

Predicting longitudinal brain changes from magnetic resonance imaging (MRI) can help characterize structural progression associated with aging and neurodegeneration. However, diffusion-based forecasting typically requires iterative denoising, limiting inference efficiency. We propose a covariate-conditioned one-step diffusion framework for multi-horizon prediction of 3D gray-matter density (GMD) maps. Rather than directly generating future anatomy, the model predicts longitudinal GMD changes through residual prediction in a single denoising step. The predicted changes are added to the baseline GMD map to reconstruct future anatomy. The model is conditioned on baseline anatomy, age, diagnosis, APOE4 allele count, and continuous follow-up time. Training combines mean squared error with a Pearson correlation loss to improve the spatial agreement between predicted and observed GMD changes. A unified model supports prediction horizons from 2 to 10 years. On the held-out ADNI test set, our method achieves a $Δ$-Pearson of 0.478, mean squared error (MSE) of $5.176 \times 10^{-3}$, and structural similarity index measure (SSIM) of 0.979, with $Δ$-Pearson reaching 0.582 at 10 years. Without retraining, external evaluation on AIBL yields a $Δ$-Pearson of 0.450, MSE of $4.016 \times 10^{-3}$, and SSIM of 0.985. Ablation studies further demonstrate the benefits of residual prediction, covariate conditioning, and correlation-based supervision. Code: https://github.com/natenaile/OneStepBrainMRI.

0.31
20

Quantifying System-Level Performance Bottlenecks in Hyperspectral Target Detection

eess.IV ·2026-11-06 ·Chase Cañas, John P. Kerekes
unusual
Abstract · 10 pages, 9 Figures, 4 Tables

Discerning core performance bottlenecks in hyperspectral target detection is highly challenging given the complex interplay between sub-systems of the imaging chain (scene, atmosphere, sensor and processing). Prior sensitivity and limitation studies offer narrow insights applicable to specific system configurations. To address the need for broader generalization, an analysis framework was constructed to quantify limitations from large ensembles of model scenarios. Key components of the framework include the use of canonical scene representations and the log-weighted area under the ROC curve (wAUC), a metric well-suited for rare target detection. By analyzing thousands of scenarios, parametric thresholds were quantified where detection performance degrades, corresponding to "knees" in performance curves. A knee significance score (KSS) is introduced to assess the relative importance of these thresholds. The framework an airborne VNIR sensor implanted in 28,000 scenarios using seven system parameters spanning the scene, atmosphere and sensor. Results suggest that aerosol visibility in the 2-6 km range is the dominant limiter in detection, followed by subpixel target percentages of 15-35%, and background clutter modeled using a t-distribution with 3-5 degrees of freedom.

0.30
21

Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time Regularisation

eess.IV ·2026-11-08 ·Andrew J. Reader, Gary J. R. Cook, Paul K. Marsden, Sarah-May Gould, Alexander Hammers +1 more
Abstract · 10 pages, 11 figures

Kinematic PET is introduced as an imaging task focused on visualisation of early radiotracer delivery and rapid multi-organ motion without gating. The proposed kinematic video reconstruction method uses 33-ms frames (~30 frames per second), initialised with 3D expectation maximisation (EM) time of flight (TOF) list-mode reconstruction, followed by cycles of a 2-stage update. These 2 stages are i) a hierarchical EM (HEM) update using multiple temporal pooling levels, and ii) a validation-adaptive space-time (VAST) regularisation update. HEM combines frame-specific EM corrections with corrections estimated from higher-count temporal blocks, slowing noise amplification for the ultrashort frames. VAST mixes each 3D target patch in a frame with source patches sampled nearby in space and time. It selects the candidate that best matches the mean of the corresponding patches in the two adjacent frames, with the unchanged patch also eligible. Optional temporal block sum correction uses the initial EM temporal sum as a reference to reduce loss of spatial detail. HEM+VAST was evaluated with a dynamic digital phantom, and demonstrated on human FDG data acquired on a Siemens Biograph Vision Quadra (28 - 58 s post-injection). At a background spatial coefficient of variation of 10%, the temporal full width at half maximum of the fastest phantom bolus was 151 ms with HEM+VAST, compared with 86 ms for the ground truth. The video frame rate FDG images reveal vascular and organ detail, radiotracer bolus passage and respiration-related multi-organ motion. Kinematic PET could complement conventional dynamic PET by supporting the development of image-derived physiological biomarkers and motion estimation for quantitative reconstruction. Future work should compare HEM+VAST with prior 4D PET reconstruction methods at the same 33-ms frame duration and matched noise levels.

0.29
22

Cross-Layer Refinement and Frequency-aware Fusion Network for Multi-Source Remote Sensing Image Classification

eess.IV cs.CV ·2026-11-02 ·Wenhan Xiao, Chuanzheng Gong, Feng Gao, Junyu Dong, Qian Du
code/data
Abstract · Under review at IEEE GRSL

Multi-source remote sensing image classification benefits from complementary spectral and structural information. However, identifying discriminative cross-modal features remains challenging. This letter proposes a Cross-Layer Refinement and Frequency-aware Fusion Network (CRFNet) within a lightweight dual-branch architecture. Specifically, a Cross-Layer Refinement Attention (CLRA) module propagates selected attention relationships across successive layers and employs top relation selection to progressively strengthen discriminative spatial dependencies while suppressing irrelevant responses. Furthermore, a Frequency-aware Complementary Fusion (FCF) module combines frequency-wise interactions with cross-modal channel attention in the Fourier domain. The resulting representations are then converted into spatial-domain gates to selectively modulate complementary features. Experiments on the Houston 2013 and Augsburg datasets demonstrate that the proposed CRFNet consistently outperforms several state-of-the-art methods. The codes are publicly available at https://github.com/oucailab/CRFNet

0.29
23

Task-Aware Bitrate Thresholds for Codec-Robust Ultrasound Segmentation

eess.IV ·2026-11-04 ·Alireza Siyavashi, Arman Shirzad, Christian Herglotz
published
Abstract · It is already accepted at IEEE Visual Communications and Image Processing Conference

Remote robot surgery and tele-ultrasound increasingly rely on real-time streaming under strict bandwidth constraints, making lossy compression unavoidable. Since the receiving end of these clinical pipelines is increasingly a machine rather than a human observer, codec selection must be guided by downstream task accuracy rather than perceptual fidelity. We evaluate three widely deployed codecs, H.264/AVC, HEVC, and AV1, on prostate ultrasound segmentation, reporting task-aware compression performance with region overlap (Dice) and boundary accuracy (HD95) as the quality metrics. To compare codecs fairly, we match their operating points at a common perceptual-quality (SSIM) level. We establish, per codec, the lowest bitrate that preserves acceptable segmentation accuracy, reporting the 5th-percentile Dice alongside the mean to expose worst-case degradation. All three codecs preserve segmentation quality (mean Dice $\geq$ 0.84) down to approximately 0.07-0.20 bits per voxel (bpv). Below this point, AV1's accuracy declines gradually, while H.264's drops sharply. As a result, H.264 needs 82% more bitrate than AV1 to reach the same region-overlap accuracy (Dice), and 104.7% more to reach the same boundary accuracy (HD95).

0.29
24

Edge-Assisted Crowdsensing for Explainable Cyclist Safety Perception

cs.CV eess.IV ·2026-11-05 ·Hongsen Cao, Chia-Yen Chiang, Mona Jaber, Meihui Wang, Yasmin Fathy
hot direction
Abstract

Cyclist fatality rates remain high despite policy support for active travel, and autonomous vehicles add complexity to mixed traffic. Neither crash statistics nor multi-model detection pipelines scale to continuous monitoring of perceived safety along a route. We present an edge-assisted crowdsensing system: handlebar cameras supply street-level frames, a vision-language model (VLM) turns each frame into structured traffic attributes through a single prompt, and an explainable boosting machine (EBM) combines them with OpenStreetMap road infrastructure and on-bike kinematics to predict a crowdsourced 1-9 safety score. Extraction belongs at the network edge: the fastest self-hosted model needs 2.49 s per frame and scoring takes 0.4 ms on a CPU. On 1,362 annotated frames from two London routes, the EBM regressor reaches 72.2 percent binary accuracy and a mean absolute error of 1.011 under five-fold cross-validation. It is within one accuracy point of black-box ensembles. Its per-feature shape functions give exact attribution: physical lane separation is worth +0.97 rating points, a painted lane +0.70 and a construction site -0.65. Planners can therefore price an infrastructure change in rating points, and the results enter cost-benefit analysis directly. We also report inter-annotator agreement (alpha = 0.4695), an attribute audit, and a sensitivity analysis linking attribute error to accuracy. With re-encoding, a 20 s sampling interval serves 1,000 riders at 54 Mbit/s at a cost of 1.4 accuracy points, making continuous monitoring practical.

0.28
25

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.28
26

DUNEDepth: Bronchoscopic Depth and Pose Estimation via Hybrid Adaptation of a 3D-Vision Foundation Model

eess.IV cs.CV ·2026-11-02 ·Qi Chang, Austin Kao, Ange Lou, William E. Higgins
published
Abstract · 10 pages, 4 figures, 3 tables. Accepted to MICAD 2026 (International Conference on Medical Imaging and Computer-Aided Diagnosis), Edinburgh,…

State-of-the-art bronchoscopy guidance systems and computer-aided diagnosis methods have emerged as important tools for early lung cancer detection. Effective use of these tools depends on being able to accurately link a patient's bronchoscopic airway exam video to their pre-operative 3D chest CT scan. Unfortunately, the derivation of such links, which include bronchoscope depth and camera motion, from the exam video remains an open problem. Building on recently proposed 3D-vision foundation models, we propose DUNEDepth, a hybrid architecture that combines a shared DUNE ViT encoder, a twin MASt3R cross-attention decoder structure, and a prediction head that includes elements of the MASt3R and Reloc3r models. To fine-tune the architecture to our application, we utilize an integrated hybrid synthetic-supervised/self-supervised training strategy that draws on both bronchoscopic video and CT-derived virtual bronchoscopic views. Experiments drawing on bronchoscopic video sequences demonstrate that DUNEDepth more accurately derives depth information and camera motion trajectories than previously proposed self-supervised methods.

0.27
27

Semantic Extraction Framework for Goal-Oriented V2X Communication Supporting Safe Intersection Passage

eess.IV cs.CV ·2026-11-06 ·Haoran Yang, Shan Lu, Takaya Yamazato
hot direction
Abstract · Accept by 2026 Asia-Pacific Conference on Communications

This paper proposes a transmitter-side semantic extraction framework for goal-oriented Vehicle-to-Everything (V2X) communication supporting safe intersection passage. Instead of transmitting raw sensory data, roadside infrastructure extracts task-relevant semantic information from video and traffic-signal sequences and organizes them into compact semantic packets for low-latency driving-decision assistance. The intersection-passing problem is formulated as a set of traffic tasks under Japanese traffic regulations, and the proposed pipeline generates perception and intent semantics through object detection, object tracking, region-of-interest (ROI)-based semantic extraction, and recommended-action generation. The framework is implemented and evaluated on a self-constructed, CARLA-based single-vehicle dataset collected under clear weather conditions. Experimental results show high recommended-action accuracy within the tested task set, while the mean processing latency remains below the frame interval of the 15~fps input video.

0.27
28

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.27
29

Spectral-spatial vision test-time training for hyperspectral image classification

eess.IV cs.CV ·2026-11-02 ·Xiang Zhao
Abstract · 25 pages,9 figures,10 tables

Hyperspectral image (HSI) classification requires the representation of contiguous spectral signatures and spatial context under limited labeled supervision. Vision test-time training (TTT) offers an alternative to fixed-weight token mixing by performing self-supervised inner-model updates on the input sequence, but its application to center-pixel HSI classification remains insufficiently characterized. We present ViTTT-HSI, a spectral-spatial adaptation of the vision test-time training (ViT3) architecture. A spectral-aware embedding stem extracts ordered-band information using spectral convolution and forms spatial tokens without reducing their spatial resolution. Two ViT3-based TTT encoder blocks perform patch-conditioned token mixing, followed by the fusion of center-pixel and neighborhood-average features for classification. We evaluate the framework on Indian Pines, Pavia University, Salinas, and Houston 2013 using ten random seeds and dataset-specific training fractions of 1% or 5%. The mean overall accuracies are 97.6390%, 98.8753%, 99.3292%, and 98.4283%, respectively. Ablations reveal a substantial contribution from the TTT inner update on Indian Pines and a smaller positive contribution on Pavia University, while the relative benefits of the spectral stem and feature fusion depend on the dataset. The results demonstrate the feasibility of using patch-conditioned vision TTT for spectral--spatial HSI classification and highlight the role of the inner adaptation mechanism.

0.26
30

Simulation-Driven Approach for Occlusion-Based Non-Line-Of-Sight Detection Using a Low-Cost Flash LiDAR

eess.IV ·2026-11-02 ·Peizhao Qiu, Emmanuel A Olowe, Zhenya Zang, Istvan Gyongy, Danial Chitnis
hot direction
Abstract

Non-line-of-sight (NLOS) imaging aims to sense objects outside the direct line of sight. While most previous work focuses on the canonical around-the-corner configuration, this work considers a more challenging occlusion-based NLOS setting in which targets are hidden by scene geometry. To avoid the challenge of collecting large real-world datasets, we have developed a photon-based Monte Carlo simulator to generate diverse synthetic training data and validate against experimental data. We trained an AI model to identify multi-bounce photon patterns associated with hidden targets. The model achieves an Average Precision (AP) of 0.91 on synthetic test data and, when transferred directly to 180 real measurements acquired with a TMF8829 SPAD flash LiDAR, achieves 86.67% accuracy and an AP of 0.95. These results show that simulated transient data can support hidden-target detection with a low-cost commercial sensor and provide an initial step toward more general occlusion-based NLOS sensing and, ultimately, hidden-scene reconstruction.

0.26
31

A Frame-Level View and Image-Quality Annotation Tool for Fetal Echocardiography: Comparison with Spreadsheet Annotation

cs.HC eess.IV ·2026-11-04 ·Mohamed Azzam, Ziyang Xu, Quinlan Couch, Zoe Keese, Andrea Cadlo +11 more
Abstract

Objective: To develop the Cardiologist Annotation Tool (CAT) for frame-level cardiac view and image-quality annotation in fetal echocardiography and compare it with spreadsheet-based annotation. Methods: CAT provides cine playback, frame navigation, and keyboard-based labeling without manual frame-range entry. Experts annotated 25 studies using both methods, and spreadsheet annotations were audited for predefined data-entry errors. In a randomized crossover study, six medical students annotated two normal studies, one with each method, against an expert reference. Results: Among 1,746 spreadsheet-annotated files, 6.2% contained major or critical data-entry errors, more frequently in congenital heart disease than normal studies (10.9% vs 3.4%). CAT yielded more annotated view segments per clip (3.6 vs 1.5). Rates of labeled and correctly labeled frames per minute were 1.77 and 1.68 times those with spreadsheets, respectively (both P = 0.031), with gains in all six students. No detectable difference in view-label accuracy was observed. Conclusion: CAT eliminates manual frame-range entry and enables finer-grained, structured annotation of fetal echocardiography, providing a practical approach to preparing datasets for AI research.

0.26
32

From Discrete Snapshots to Geometric Entity: Motion-Native Channel Tracking for THz Near-Field XL-MIMO

eess.SP eess.ASeess.IVeess.SY ·2026-11-07 ·Yuheng Fan, Chuang Yang, Mugen Peng
Abstract

Channel tracking in mobile terahertz (THz) near-field extremely large-scale multiple-input multiple-output (XL-MIMO) systems is challenging because spherical-wave propagation couples angle and range, leading to rapid and nonlinear channel evolution under sparse pilot observations. Existing approaches typically estimate pilot-local channel or position snapshots before applying temporal tracking or smoothing, making them vulnerable to information loss during snapshot formation. To break this bottleneck, we propose a paradigm shift from tracking discrete snapshots to estimating a holistic geometric entity, namely, one shared continuous UE trajectory over the tracking window. Specifically, we parameterize the trajectory using a low-dimensional cubic B-spline representation and directly couple the per-pilot profile likelihoods through this shared trajectory before any pilot-local position estimate is finalized, thereby inducing continuous near-field channel evolution. We further characterize the efficient geometric information supplied by each pilot observation and its aggregation in the shared spline-coefficient space. Based on this formulation, we develop a regularized maximum a posteriori estimator and a quadratic-penalty lifted solver that separates parallel pilot-local geometric updates from a structured global spline update. The resulting global system is banded and, for a fixed spline degree, admits linear-complexity factorization, enabling an efficient structured implementation. Simulations demonstrate consistently improved tracking accuracy over representative temporally refined baselines in the tested medium-to-high-SNR regime, together with a favorable accuracy--runtime trade-off. These results highlight the benefit of coupling sparse pilot observations through a shared continuous trajectory rather than temporally processing independently estimated snapshots.

0.26
33

RapidMitDet: Boosting Computational Efficiency for Mitosis Detection via Magnification Alignment

eess.IV ·2026-11-05 ·Longfei Wang, Jiatai Lin, Junyu Guo, Chaoqun Chen, Danyi Li +10 more
code/data
Abstract

Automated mitosis detection is a critical research focus, enabling pathologists to rapidly assess mitotic indices for tumor malignancy evaluation. However, most of the existing detection approaches suffer from significant computational inefficiency due to the giga-pixel image resolution of Whole-Slide Images (WSIs), which greatly hinders their clinical applicability. In this study, we propose RapidMitDet, a computational efficient mitosis detection approach. Our method employs a coarse-to-fine framework, first identifying mitotic candidates at lower magnification and then confirming them at higher magnification. In the coarse-detection stage, we introduce magnification-aligned knowledge distillation to reduce the information gap between magnification levels while minimizing the performance degradation in the lower magnification detection model. In the subsequent fine-classification stage, we propose adaptive triplet learning (ATL) to optimize infomative sample selection, thereby enhancing discrimination between mitotic and non-mitotic instances. Experimental results show that RapidMitDet achieves the optimal accuracy-efficiency balance at 20x magnification, improving computational speed by up to 5.62 times over the latest state-of-the-art (SOTA) methods. Due to its lightweight model design, RapidMitDet can also deliver efficient detection at higher magnification (40x) while achieving even higher detection performance. In WSI-level evaluations, our method shows strong agreement with pathologists' diagnoses (ICCs: 0.879 (40x), 0.822 (20x)) while maintaining superior efficiency, highlighting its potential for clinical application. Code is available at https://github.com/logincat/RapidMitDet

0.25
34

Toward Artifact-Free Dermoscopy: Characterization of ISIC 2019 Image Defects for Deep Learning Applications

eess.IV ·2026-11-02 ·Victoria Wegley, Joshua Hoog, Tristan Crawford, Keith Miller, William Fons +8 more
Abstract · 9 pages, pre journal publication

The International Skin Imaging Collaboration (ISIC) archive offers the largest publicly available collection of dermoscopic images for skin lesion analysis. However, the ISIC 2019 dataset suffers from several acquisition artifacts such as hair occlusions, vignetting, surgical ink markings, and ruler scales, all of which compromise its utility in deep learning workflows by introducing non-biological visual structures. To address these limitations, we present a rigorously annotated version of ISIC 2019 that includes binary masks for key artifact types. Ink marks and vignetting were annotated through systematic manual review and iterative refinement using professional image editing software. For hair and ruler artifacts, we implemented a semi-automatic pipeline based on our previously developed deep learning architecture, ChimeraNet. Automated predictions were then manually corrected as needed for precision. The resulting dataset supports both the development of our own melanoma detection model and broader community research requiring artifact-mitigated dermoscopic images.

0.25
35

Polarization Aware Deep Learning Framework for SAR Despeckling

eess.IV cs.CV ·2026-11-06 ·Gianpaolo Passarello, Sergio Vitale, Hossein Aghababei, Giampaolo Ferraioli, Vito Pascazio
Abstract

Speckle is an inherent characteristic of synthetic aperture radar (SAR) imagery that complicates image interpretation and the extraction of reliable information. Although deep-learning-based despeckling methods have demonstrated promising performance, their applicability across different polarimetric configurations is often limited by the need for specialized architectures or separate training procedures. This paper presents a unified deep-learning framework for despeckling single-, dual-, and full-polarization SAR data using a single trained convolutional neural network. The proposed approach adopts a common nine-channel representation of the polarimetric covariance matrix and a polarization-aware masking strategy to accommodate different configurations without modifying the network architecture. Qualitative and quantitative comparison on three different scenes from different sensors demonstrate competitive performance across the considered experiments and support the feasibility of a unified, polarization-flexible approach to SAR despeckling across different polarimetric configurations.

0.25
36

Label-Preserving Fourier Domain Adaptation with Generative-AI and Real Style Donors for 3D Mitral Valve Segmentation

eess.IV cs.CV ·2026-11-03 ·Javeria Javed, Ahmed Salim, Muhammad Mahboob Ur Rahman
Abstract · 7 pages, 1 figure, 3 tables, submitted to IEEE for possible publication

Accurate segmentation of the mitral valve from three-dimensional transesophageal echocardiography (3D TEE) is severely restricted by the scarcity of publicly available expert- annotated volumetric datasets. To address this critical limitation, we investigated Fourier Domain Adaptation (FDA), utilizing general-purpose generative-AI images (from platforms like Chat- GPT, Google Gemini, and Microsoft MAI) as annotation-free style donors for 3D mitral valve segmentation. We employed a DeepMitral residual U-Net model on the public MVSeg2023 dataset, comparing six conditions over three runs: real-only training, traditional augmentation, FDA with each generative source, and a non-AI FDA control using real-image style donors, plus an optimization-matched real-only control and a \b{eta} sensitivity analysis. Case-level paired testing showed that FDA with these generative sources led to significant reductions in boundary- and surface-related errors across all three donor conditions relative to the primary real-only baseline. However, the impact on the core segmentation metric, Generalized Dice Score (GDS), proved generator-dependent. ChatGPT-FDA showed a significant GDS advantage over the optimization-matched control but not over the primary baseline, and Gemini-FDA showed no significant GDS difference. Notably, only MAI-FDA provided a statistically robust and significant increase in GDS compared to the primary baseline. The \b{eta} sensitivity was not robust across training runs. These findings confirm that FDA remains an important augmentation mechanism. While generative-AI images offer a practical means of acquiring style diversity without new annotations, the non-AI control performed comparably to ChatGPT-FDA, so we do not conclude that this approach is superior to training with real-image donors.

0.24
37

Scaling global tractography with ExaTract: from large cohorts to ultra-high-resolution datasets

eess.IV cs.DCmath.NA ·2026-11-02 ·Simon Legeay, Felix Matuschke, Bastien Herlin, Jan André Reuter, Christophe Destrieux +3 more
code/data
Abstract

Global tractography offers a theoretical framework for reconstructing white matter connectivity from diffusion MRI by jointly inferring all streamlines and their consistency with the diffusion signal and underlying anatomical priors. However, its sequential nature and log-linear complexity make it computationally prohibitive at the scales demanded by neuroimaging, from large population cohorts such as the Human Connectome Project (HCP) to ex vivo ultra-high-field acquisitions at mesoscopic resolution. In this work, we present ExaTract, a parallelized spin-glass tractography framework designed for high-performance computing (HPC) architectures. Implemented as an open-source MPI+Kokkos application, ExaTract partitions the tractography domain into spatially overlapping regions processed across distributed memory nodes, with regular synchronization of boundary modifications to preserve global convergence guarantees. We validate ExaTract on both in vivo and ex vivo diffusion MRI data: the complete HCP dataset demonstrates population-scale throughput, while the high-resolution Chenonceau dataset provides the first mesoscopic structural connectome derived from global tractography.

0.24
38

ELiCv2: Learned LiDAR Geometry Compression under Real-Time Embedded Constraints

eess.IV ·2026-11-03 ·Soowoong Kim, Junsik Kim, Gun Bang, Jinsoo Choi
Abstract

Improving learned LiDAR compression increasingly relies on heavier inference, making it harder to meet the constraints of real-time embedded systems. We present ELiCv2, which removes two sources of redundant computation in progressive coding. Its discrete entropy interface selects a precomputed integer CDF instead of materializing one from a per-voxel distribution, while its occupancy-driven kernel-map builder derives finer-level sparse-convolution kernel-maps directly from the decoded hierarchy, eliminating coordinate-based neighbor search. ELiCv2 reinvests the recovered computation budget in lightweight ego-motion-aware temporal conditioning that gathers local occupancy context from the aligned previous reconstruction. On four LiDAR datasets and an NVIDIA Jetson Thor, ELiCv2 achieves a mean BD-rate reduction of 30.97% over G-PCC with channel width C=32 while sustaining the 20Hz nuScenes capture rate. Increasing the channel width to C=64 improves the mean reduction to 35.22%.

0.24
39

Finite Element Elastographic Analysis of Kidney MRI for Computational Assessment of Chronic Kidney Disease

eess.IV ·2026-11-04 ·A. Bhattacharjee, M. M. Rahman, A. Srivastava, E. H. Bhuiyan
unusual
Abstract · Original research article

Background and Objective: Bridging kidney MRI with patient-specific computational biomechanics may enable accurate, noninvasive assessment of chronic kidney disease. To develop a finite element method (FEM)-based computational elastography framework for estimating renal biomechanical properties from conventional kidney MRI and to evaluate its ability to differentiate chronic kidney disease (CKD) from healthy controls. Methods: Kidney segmentation masks from healthy control and CKD subjects were converted into triangulated surface meshes, and watertight surfaces were tetrahedralized to create volumetric FEM meshes. Kidney tissue was modeled as a nearly incompressible Kelvin-Voigt viscoelastic material. Harmonic wave propagation simulations were performed using FEM, followed by Helmholtz-based elastographic inversion to estimate complex shear modulus distributions. Derived biomechanical parameters were used for CKD classification using machine learning models. Results: FEM-derived stiffness estimates showed consistency with stiffness ranges previously reported in human renal MRE studies and also showed measurable differences between healthy and CKD groups. Machine learning models trained on FEM-derived features achieved classification performance up to 86.26% cross-validation accuracy with an AUC of 0.92. Conclusion: FEM-derived elastographic parameters showed potential for distinguishing CKD from healthy tissue and may provide an alternative for renal biomechanical assessment without dedicated MRE acquisition.

0.23
40

Extended Field-of-View Passive mmWave Imaging Using Implicit Neural Representations

eess.IV ·2026-11-02 ·Sanjaya Herath, Matthew R. Ziemann, Christopher A. Metzler
unusual
Abstract

We introduce a self-supervised learning-based framework for expanding the field-of-view (FoV) of passive real-aperture millimeter wave (mmWave) imaging systems. Our framework exploits aliasing artifacts/grating lobes---which are an inherent part of mmWave image formation---to expand FoV. Specifically, we recognize that removing aliasing artifacts can be cast as an underdetermined deconvolution problem and that in solving this problem, one can expand the system's FoV. We solve this deconvolution problem and expand the system's FoV by enforcing temporal regularity with time-varying Implicit Neural Representations (INRs). We demonstrate the effectiveness of our approach through extensive simulations and real-world experiments with Phase Sensitive Innovation's (PSI) state-of-the-art electro-optical modulation based passive mmWave imaging system.

0.23
41

Destructive augmentations for prostate lesion segmentation on heterogeneous biparametric MRI data

eess.IV ·2026-11-04 ·Thibault Heintz, Rachit Saluja, Seungbin Park, Daniel Margolis, Timothy McClure +2 more
benchmark
Abstract

Training prostate lesion segmentation models on biparametric MRI (bpMRI) is limited by small datasets with heterogeneous imaging acquisition protocols and annotations. In this work, we train a segmentation model on a combined cohort of 1,579 lesion-containing training cases from five datasets, representing, to our knowledge, the largest collection of prostate lesion annotations used for this task. Additionally, we investigate two complementary improvements to the widely used nnU-Net framework. First, we introduce a random wavelet augmentation and show that random sym4 (Symlet) wavelets outperform random convolution augmentation in terms of average Dice score, with only a modest reduction in F1 score due to lower precision. Second, we evaluate instance-level losses and show that Connected-Component-based Dice (CC-Dice)-CE loss complements BackSplit, yielding better performance than BackSplit alone. Together, these improvements achieve the best overall performance, reaching a Dice score of 0.614 on the public Prostate158 test set and establishing a new state-of-the-art on this benchmark. We publicly release our training code and model weights.

0.23
42

CNVAE: Anatomically Correct Segmentation via Conditional Generative Modeling

eess.IV ·2026-11-04 ·Freddy Jiang, Loic Le Folgoc, Elsa Angelini
Abstract

Supervised deep learning segmentation models, although unparalleled in performance, are not immune to anatomical mistakes. We develop a segmentation-by-generation paradigm extending the Nouveau VAE (NVAE) generative framework for anatomically correct cardiac segmentation. In particular, we propose a novel conditional NVAE model (CNVAE) for conditional shape generation, and explore its capabilities for image segmentation in two scenarios: (1) direct image-to-mask CNVAE for one-step segmentation; (2) mask-to-mask CNVAE for refinement of segmentation masks produced by third-party segmentation models. Both models are lightweight and return consistently anatomically valid segmentation masks (> 98% success rate, an improvement of 15% above state-of-the-art segmentation models) on the cardiac segmentation/editing tasks of interest, without loss of accuracy in segmented contours.

0.23
43

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.23
44

Super-resolved digital terrain models for GEDI geolocation correction: agreement with airborne LiDAR DTM-based corrections at the beam level, not the footprint level

eess.IV cs.CVphysics.geo-ph ·2026-11-06 ·Natsuki Yuda, Shinichiro Shirota
Abstract · Appendices will be added in a future version

The Global Ecosystem Dynamics Investigation (GEDI) mission measures three-dimensional forest structure with a LiDAR aboard the International Space Station. GEDI observations have geolocation errors of about 10 m, which cause misalignment with other remote sensing data and reduce the accuracy of downstream tasks. Matching GEDI ground elevations against high-resolution digital terrain models (DTMs) from airborne LiDAR is one way to correct these errors, but such DTMs exist in few regions. To widen this method's applicability, we super-resolved a more widely available low-resolution DTM and used it for the matching. Our question is whether a super-resolved DTM yields the same correction as a 1 m-resolution airborne LiDAR DTM and, if not, why. In steep forests of western Japan, we super-resolved an existing 10 m-resolution DTM to 1 m. Improving its accuracy required fusion with a global 30 m-resolution DTM from a different source. Using the resulting DTM, we corrected GEDI observation positions first by a single shift per ground track, then per observation. For most tracks, the shifts nearly matched those from the airborne LiDAR DTM, likely because DTM errors canceled out across many observations. Per-observation corrections, however, did not match. At a single observation, the error does not cancel out and is too large for the correction. This error likely originates mainly from the input DTM. Therefore, even without a 1 m-resolution DTM, a roughly 10 m-resolution DTM, fused with a global DTM and super-resolved to 1 m, should yield track-wise corrections nearly matching those from a 1 m-resolution DTM.

0.22
45

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.22
46

Arctic-SAR: A Cross-Sensor RADARSAT Constellation Mission and Sentinel-1 Dataset and Fusion Benchmark for Multi-Task Sea Ice Mapping

eess.IV ·2026-11-04 ·Niloofar Azad, Kyle Gao, Javier Noa Turnes, Youssef Nafea, Linlin Xu +1 more
benchmark
Abstract

Current sea ice mapping benchmarks are mostly built around single-sensor SAR products, limiting the evaluation of cross-sensor variability and the effectiveness of combining observations from different SAR platforms. Models trained on such datasets may also be sensitive to sensor-specific artifacts, radiometric characteristics, and acquisition conditions, which can reduce robustness and limit generalization. To address these limitations, this study introduces Arctic-SAR, a cross-sensor SAR dataset for Arctic sea ice mapping, constructed by matching RADARSAT Constellation Mission (RCM) dual-polarization imagery with Sentinel-1 scenes from the AI4Arctic Sea Ice Dataset. The dataset consists of 221 co-registered scenes and supports multi-task prediction of sea ice concentration (SIC), stage of development (SOD), and floe size (FLOE). In addition to the dataset, we establish a benchmark for cross-sensor SAR sea ice mapping by quantifying the contribution of RCM imagery and evaluating single-sensor baselines alongside representative input-, feature-, and decision-level fusion strategies within a consistent multi-task U-Net framework. Across three independent runs, the test results show that the effectiveness of cross-sensor fusion is strongly dependent on the fusion strategy and prediction task. Decision-level fusion achieves the highest mean combined score of $77.28\pm0.29\%$, essentially matching the Sentinel-1-only baseline at $77.26\pm0.13\%$, while achieving the highest SIC \(R^2\) score. These findings show that Sentinel-1 and RCM provide task- and class-dependent information, but that simple joint cross-sensor fusion does not consistently improve generalization over a strong single-sensor baseline. Arctic-SAR therefore provides a benchmark for cross-sensor SAR fusion research in automated Arctic sea ice mapping.

0.22
47

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.22
48

Frequency-consistent synthesis and selective transfer for medical image analysis

eess.IV cs.CV ·2026-11-06 ·Zhuhui Wang, Jianwei Zuo, Xin Peng, Kai Zhong, Xuliang Deng +1 more
Abstract · 40 pages, 5 figures

Complementary imaging is not always available, and realistic synthesis does not necessarily improve downstream analysis. Here we introduce a training framework linking medical image synthesis to task learning through adaptive frequency consistency and selective feature transfer. Image-specific frequency constraints encourage consistency of structure and detail. Features are transferred only when a teacher using synthetic images achieves a lower task-error score than the student by a task-specific margin on a labelled training sample. Evaluations across five datasets show improved translation fidelity with three adversarial and diffusion-based translators trained without paired supervision, alongside gains in brain-tumour segmentation on tumour-containing slices and lesion centre-point detection. All 105 reported paired comparisons yielded point estimates favouring the proposed methods, including 36 external translation comparisons on post?treatment MRI without retraining. These findings support synthetic modalities as task-oriented complements to acquired scans when complementary imaging is unavailable.

0.21
49

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.21
50

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.19
51

eSharp: Diffusion-based Sharp Monocular Metric Event-to-Depth Estimation

cs.CV eess.IV ·2026-11-05 ·Qiushi Dai, Aniket Dashpute, Yuhao Liu, Rishubh Parihar, Guha Balakrishnan +1 more
Abstract

Depth perception is fundamental for autonomous navigation, industrial inspection, and mixed-reality systems. It often operates under strict constraints on power and form factor. In such cases, monocular depth estimation (MDE) is often used. Even as recent advances continue to improve monocular depth quality, conventional frame-based MDE systems remain challenged by fast motion and high-dynamic-range scenes. This work introduces eSharp, an MDE framework that addresses these problems using an event camera. eSharp repurposes pretrained diffusion priors for event-only MDE and produces accurate metric depth with unparalleled sharpness on real data. Real-world event datasets provide only sparse LiDAR depth maps for ground-truth supervision, making dense prediction challenging. We address this limitation through cross-modal distillation, using LiDAR-calibrated dense pseudo-labels generated from a spatially co-registered frame camera to train eSharp. Experiments show that eSharp outperforms prior event-to-depth baselines in both metric-depth accuracy and spatial fidelity, establishing diffusion models as a promising foundation for event-driven 3D perception.

0.18
52

SideAge-RiskNet: Predicted Mammographic-Age Features for Future Breast Cancer Risk and Laterality Prediction

eess.IV ·2026-11-04 ·Haoyan Ding, Encheng Su, Chaowei Wu, Lixia Wang, Qian Wang +4 more
Abstract · 5 pages, 2 figures

Whether breast-specific mammographic aging provides information beyond chronological age for future cancer prediction remains unclear. We propose SideAge-RiskNet, a framework integrating predicted mammographic-age features with breast-specific representations for multi-year breast cancer risk and conditional laterality prediction. A side-aware DenseNet121 trained on never-cancer reference examinations estimates left and right breast ages. Age-adjusted residuals and bilateral age descriptors are subsequently fused with corresponding image representations, while clinical variables contribute through an image--clinical risk branch. The framework jointly predicts cumulative cancer risk over 1--5 years and the subsequently affected breast among unilateral cancer cases. Across 4,480 EMBED and 248 external examinations, pre-cancer scans demonstrated pronounced bilateral age asymmetry. SideAge-RiskNet established state-of-the-art performance in 1--5-year risk assessment over Mirai and AsymMirai with mean risk AUROCs of 81.73% on EMBED and 72.83% on CSMC. Furthermore, it enabled conditional cancer laterality prediction, achieving AUROCs of 73.26% and 82.53%, respectively. This demonstrates the critical utility of bilateral aging phenotypes in localized breast cancer risk surveillance.

0.18
53

Token Importance-Aware Semantic Communication Enabled Robust Video Transmission

eess.IV cs.AIcs.MM ·2026-11-03 ·Xiwen Zhang, Yubo Peng, Luping Xiang, Kun Yang
Abstract

Video applications are increasingly prevalent, yet their high data volume and temporal dependency make robust wireless transmission challenging under limited communication resources. To address this issue, we propose a token importance-aware semantic communication (Ti-SemCom) framework for bandwidth-efficient video transmission. Specifically, object and motion information is jointly extracted to identify communication-relevant regions, which are hierarchically associated with semantic tokens according to their importance. The transmitted tokens are then dynamically selected based on both token importance and the available bandwidth, prioritizing more informative video content under resource constraints. At the receiver, untransmitted regions reuse recently reconstructed references to further reduce redundant transmission. Experiments on the CAVIAR dataset show that Ti-SemCom can achieve an 88.3\% reduction in communication cost while maintaining competitive reconstruction quality.

0.16
54

OraRefer: Segmentation-Guided Multi-Photograph Fusion for Oral Cancer Screening with Guaranteed Patient-Level Sensitivity

cs.CV eess.IV ·2026-11-05 ·Rupam Mukherjee, Mehakdeep Singh, Shirin Dasgupta, Subhamoy Mandal
Abstract

Oral cancer and the oral potentially malignant disorders (OPMD) that can precede it are visible on the oral mucosa, which makes smartphone photographs a promising tool for screening. Deep learning models for this task classify individual photographs. However, screening refers patients, not photographs: a patient is usually photographed several times, and the referral decision must miss no more than a set share of patients with disease. We propose OraRefer, a patient-level screening model that reads each photograph with a segmentation-guided foundation model that conditions its class decision on the predicted lesion, combines all photographs of a patient with risk factors, and refers through a threshold with a finite-sample sensitivity guarantee. The model localizes the mouth itself, so inference needs no annotation. On 3000 photographs of 714 patients, patient-level fusion reaches an AUROC of 0.919 and outperforms attention-based multiple-instance learning. At a 90% sensitivity target, OraRefer detects 95% of patients with OPMD or cancer and misses 3 of 61 patients with cancer, at a specificity of 0.610. Because the threshold is calibrated without retraining, each clinic can set its own guaranteed operating point on a local calibration sample.

0.14
55

Interpretable Multimodal MRI-Clinical Fusion for Functional Outcome Prediction After Acute Ischemic Stroke

cs.LG cs.AIcs.CVeess.IV ·2026-11-05 ·Sina Raeisadigh, Henning Müller, Abderrahmane Hedjoudje
Abstract · 5 pages, 2 figures, 1 table

This study evaluates the added prognostic value of day-1 multimodal MRI for predicting three-month functional outcome after acute ischemic stroke (AIS). Sixty-six AIS patients with ADC, DWI, FLAIR, and clinical data were analyzed. Three-dimensional pretrained ResNet embeddings were extracted from each MRI modality, reduced using fold-isolated principal component analysis, and combined with structured clinical variables and ADC-derived lesion biomarkers. Linear support vector machines were evaluated using eight-fold stratified group cross-validation across MRI modality combinations. Clinical-only modeling achieved strong performance (AUC = $0.899 \pm 0.151$), while MRI-only models showed limited discrimination (AUC $\approx$ $0.67$-$0.73$). Among multimodal configurations, FLAIR-clinical fusion achieved the highest mean cross-validated performance (AUC = $0.948 \pm 0.061$), followed by ADC-clinical fusion (AUC = $0.941 \pm 0.094$). Full ADC-DWI-FLAIR fusion did not consistently outperform single-modality clinical fusion. Feature-importance analysis identified age, NIHSS subscores, ADC lesion burden, and learned FLAIR representations as key contributors, while qualitative FLAIR activation maps showed responses over lesion-like regions. These findings suggest that compact day-1 FLAIR and ADC representations provide complementary prognostic information beyond clinical variables and support interpretable, data-efficient outcome prediction in AIS.

0.14
56

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.14
57

DINOFAS: Bonafide-Centric Representation Learning for Face Anti-Spoofing

cs.CV cs.AIeess.IV ·2026-11-02 ·Shakeel Muhammad Ibrahim, Muhammad Sohail Ibrahim, Muhammad Shahid Jabbar, Shujaat Khan
Abstract · 11 pages, 5 figures

Face anti-spoofing (FAS) models often learn attack- and dataset-specific cues that degrade performance under unseen acquisition conditions and presentation attacks. We present DINOFAS, a DINOv3-based framework that formulates FAS as bonafide-centric representation learning. The proposed framework combines parameter-efficient DINOv3 adaptation using low-rank adaptation (LoRA), an attention style-content disentanglement (ASCD) module for reducing domain-specific appearance variations, and a dual-branch architecture that separates prototype-based liveness learning from attack-semantic supervision. The model is jointly optimized using a bonafide-centric prototype objective, an attack-semantic classification loss applied to detached features, and orthogonality regularization. DINOFAS achieves an average HTER of 9.09\% under the standard OCIM leave-one-domain-out protocol, where training is performed on three source datasets and evaluation is conducted on the held-out unseen domain. We further evaluate synthetic-to-real generalization by training exclusively on SynthASpoof and testing on four unseen real-world datasets, where DINOFAS achieves the lowest average HTER of 21.41\% and the highest average AUC of 86.14\% among the compared methods. Evaluations on OULU-NPU and SiW-Mv2 additionally demonstrate robustness to variations in acquisition conditions, devices, and unseen presentation attacks.

0.13
58

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.12
59

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.11